Tender For Name Of Work :-A/R & maintenance of Public Health Services At Iit Delhi. Sub-Head:-Waterproofing Of Ugr Near Vaishali Appartments At Iit Delhi.
Tender Value
45.40 Lakhs
Estimated cost
Bid Submission
27 Jul 2026
2 days left
EMD
90820
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Name Of Work :-A/R & maintenance of Public Health Services At Iit Delhi. Sub-Head:-Waterproofing Of Ugr Near Vaishali Appartments At Iit Delhi.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of wall tiles including base plaster of any mix and thickness including the disposal of malba/debris for all lead and lifts, all complete as per the direction of the Engineer-In-Charge. |
| 2 | Removing the sticky mortar layer by grinding the top surface of the RCC wall/floor without damaging the existing surface by using a Hand/machine Grinder, including using water jet, and the disposal of debris for all lead and lifts, all complete as per the direction of the Engineer-In-Charge. |
| 3 | Fibre Reinforced Patch Repair MortarSupply and apply a pre-batched one component polymer modified cementitious,Fiber Reinforced, dual shrinkage compensated, patch repair mortar with thickness upto 40mm.Product: SikaMonoTop®-122 FBulk Density: apox 1.3 Kg./l at 27 °C.System requirements: compressive strength >= 50 N/mm2 (28 days) according to ASTM C 109; Tensile strength in flexure >= 9N/ mm2 (28 days) according to EN196-1.Tensile Adhesion strength >= 12N/ mm2 (28 days) according to ASTM C 882, Pot Life : 40 Min. |
| 4 | Drilling and fixing injection packers in RC members including, Drilling Holes: Drilling 14 mm dia., D/2 mm deep holes in structural members at the intervals of D mm c/c horizontally and D mm c/c vertically in staggered manner at an angle of 45 degree or as per recommendation of engineer in charge.(D is the section thickness) Cleaning of holes: Clean the holes by air blower prior to fixing nozzles.Fixing of Packers: Insert 12 mm dia., 50~75 mm long NRV packers in cleaned holes with structural grade epoxy adhesive like Sikadur-31 or equivalent.Cutting of Packers: Cut the packers by cut of wheel after completion of grouting without damaging structural elements. |
| 5 | Epoxy Injection for Wet / Underwater Supply and apply a solvent-free, 2 component moisture insensitive, high early strength liquid, based on epoxy resin suitable for underwater condtions. Product: Sikadur®-53 (UF)Density : 1.1 Kg./lProduct requirements: compressive strength>=40 N/mm2 (1 days) and >= 50 N/mm2 (7 days) according to ASTM D 579; Tensile Adhesion strength > 8 N/mm2 (14 days) according to ASTM C 882; tensile strength >=30 as per ISO527. |
| 6 | Pipe Pentetrations, fittings Supply and apply solvent free, moisture insensitive epoxy resin based patch repair putty on vertical surfaces. The putty shall be applied to a thickness of minimum 20mm on pipe penetration joint to concreteProduct: Sikagard®-694 F (I)Yield: 0.6 ltr/kg.Product requirements: suitable for submerged condition; compressive strength of 40 N/mm2 (1 day) according to IS 9162-1979. |
| 7 | Epoxy Modified Cementitious Thin Mortar for Moisture Barrier. Supply and apply 3 Componend Epoxy modified Cementitous, thixotropic, fine textured mortar for levelling and finishing concrete, mortar or stone Surface. Product : Sikagard 720 Epocem INMixed density : 2.01 Kg./LSystem requirements: compressive strength >= 40 N/mm2 (14 days) according to ASTM C 579Tensile Adhesion Strength : > 4Mpa in 7days (EN 1542) Consumption : 2Kg./SQM/mm layer thicknessPot Life : 30 Min at 27 Degree C |
| 8 | Biogenic Corrosion Protection Coating on Xolutec TechnologySupply and apply 2-component highly chemical resistant, crack-bridging, biogenic sulfuric acid corrosion resistant, Xolutec - Technology based, Membrane Coating along with Xolutec Based w componend primer. The coating shall have very low VOC, Moisture Tolerant, CE Certified as per EN 1504-2 and Proven for long-term resistance to biogenic sulfuric acid corrosion resistance from Fraunhofer Institute. Primer : Sikagard® P 770Coating: Sikagard® M 790 The primer shall have below properties: Density : 1.2 g/cm3 (EN ISO 2811-1); Viscosity : 650 mPas (EN ISO 3219); Glass transition temperature : 55 Degree C at 28 days (EN 12614).The coating shall have below properties : Density : 1.2 g/cm3 (EN ISO 2811-1); Mixed Viscosity 2800 mPas (EN ISO 3219); Adhesion to wet concrete after 28 days > 2.2 Mpa (EN 13578); Adhesion after freeze-thaw cycles > 2 Mpa EN 13687-1; CO2 permeability SD > 200m (EN 1062-6); Water vapor permeability > 120m (EN ISO 7783); Capillary water absorption : 0.0005 Kg./m2·h0,5, (EN 1062-3); Tensile strength : > 20 Mpa (EN ISO 527-1/-2); Abrasion resistance - Taber test: <200 mg loss (EN ISO 5470 -1); Shore D Hardness : 80 (EN ISO 868/07); Static crack bridging : A3 (+ 23 ºC) (EN 1062-7); Dynamic crack bridging : B3.1 (23° C) (EN 1062-7); Elongation > 20% (DIN 53504) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysJul 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender