Tender For Supply Of Materials/Medicines For Patients Of The Neurosurgery Department And Others In The Hospital, Under The Mukhyamantri Nishulk Nirogi Rajasthan Yojana, M-Aay, And Rghs Schemes, Short-Term Rate Contract For 2 Year
Tender Overview
Project Description
Tender for Supply Of Materials/Medicines For Patients Of The Neurosurgery Department And Others In The Hospital, Under The Mukhyamantri Nishulk Nirogi Rajasthan Yojana, M-Aay, And Rghs Schemes, Short-Term Rate Contract For 2 Year , Item Wise Boq Boq_Ver3.0 Item Wise Normal Inr Only Inr Select, Excess (+), Less (-) Tender Inviting Authority: Member Secretary, Rmrs, Pbm Hospital,Bikaner Name Of Work: Supply Of Materials/Medicines For Patients Of The Neurosurgery Department And Others In The Hospital, Under The Mukhyamantri Nishulk Nirogi Rajasthan Yojana, M-Aay, And Rghs Schemes, Short-Term Rate Contract For 2 Year Contract No: Soenib 13 ( 2026-27) Bidder Name : Price Schedule (This Boq Template Must Not Be Modified/Replaced By The Bidder And The Same Should Be Uploaded After Filling The Relevent Columns, Else The Bidder Is Liable To Be Rejected For This Tender. Bidders Are Allowed To Enter The Bidder Name And Values Only ) Number # Text # Text # Number # Text # Number Number Text Text # Number # Text# Text # Number # Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number # Number # Text Text Number # Number # Date Number # Number # Text # S.No. Item Name / Quantity Item Code / Make Quantity Unit Estimated Rate Make Packing Addition / Deduction Addition / Deduction Values Currency Convertion Against Each Item Quoted Currency In Inr / Other Currency Each Rate Without Tax Rs. P Excise Duty Gst In Figures To Be Entered By The Bidder Rs. Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 Iiird Party I.E Dgs&D / Rites Etc Inspection Charges @0.34%+Service Tax Less For Cenvat Credit,If Any Respect Of Supplies Under Full Excise Duty Category Total Amount Without Gst Total Amount With Gst Total Amount In Words , Cervical C1-C2 Lateral Mass Screw With Plate/ Rod (Titanium)- 1 Set (2 Screw Titanium) Lateral Mass & Occipitocervical Module- Three-In-One Set Of Options That Provide Adjustability, Flexibility & Adaptability To Accommodate For Anatomical Challenge Within Occipitocervical Spine System Implant Should Give Surgeon Choice Of Adjustable Oc Plate, Midline Plate, Rod Screws & Screw Connector. System Should Have Polyaxial Lateral Mass Screw In 3.5Mm & 4.0Mm Diameter & Length Should 10Mm To 36Mm With 2Mm Increment. System Should Have Reverse- Angle Design & 45 Degree Angulation With Smooth Tulip Head System Should Adjustable Occipital Plate Between The Two Rods System Should Have Cortical Bone Screw In Sizes 4Mm, 4.5Mm & 5Mm Dia & Length 6Mm To 12Mm With 2Mm Increment System Should Have Laterial Offset Connector Accommodate Medical - Laterial Flexibility In Challenging Rod/Screw Alignment Situation. System Should Have Hooks In The Set System Should Have Transverse Connector System Should Be Available For Demonstration As Per The Requirement. Isi/Iso/Gmp/ Who/ Usfda , Occipital Plate (Titanium) With Screw (Titanium) And Connector- 1 Set Lateral Mass & Occipitocervical Module- Three-In-One Set Of Options That Provide Adjustability, Flexibility & Adaptability To Accommodate For Anatomical Challenge Within Occipitocervical Spine System Implant Should Give Surgeon Choice Of Adjustable Oc Plate, Midline Plate, Rod Screws & Screw Connector. System Should Have Polyaxial Lateral Mass Screw In 3.5Mm & 4.0Mm Diameter & Length Should 10Mm To 36Mm With 2Mm Increment. System Should Have Reverse- Angle Design & 45 Degree Angulation With Smooth Tulip Head System Should Adjustable Occipital Plate Between The Two Rods System Should Have Cortical Bone Screw In Sizes 4Mm, 4.5Mm & 5Mm Dia & Length 6Mm To 12Mm With 2Mm Increment System Should Have Laterial Offset Connector Accommodate Medical - Laterial Flexibility In Challenging Rod/Screw Alignment Situation. System Should Have Hooks In The Set System Should Have Transverse Connector System Should Be Available For Demonstration As Per The Requirement. Isi/Iso/Gmp/ Who/ Usfda Approved. , Sub Axial Cervical Lateral Mass Screw (Titanium)- 1 Screw Rate Isi/Iso/Gmp/ Who/ Usfda Approved. , Titanium Rod ( 01 Set- 02 Rods) Isi/Iso/Gmp/ Who/ Usfda Approved. , Titanium Cervico - Dorsal Tapered Rod ( 01 Set- 02 Rods) Isi/Iso/Gmp/ Who/ Usfda Approved. , C1 C2 Spacer (Titanium3,5 Mm X 8Mm Height)-1 Isi/Iso/Gmp/ Who/ Usfda Approved. , Lateral Off Set Connector-1 Isi/Iso/Gmp/ Who/ Usfda Approved. , Dominos (Compatible To Connect 3.5/5.5Mm Rods)-1 Isi/Iso/Gmp/ Who/ Usfda Approved. , Titanium Standalone Cage With Inbuilt Screws-1 Anterior Cervical Interbody Fusion Device With Screw (Stand Alone Cage) The Implants Should Be Made From Titanium/Radiolucent Peek The Implants Should Be Stand Alone Interbody Fusion Device For C-Spine Soacer Component Must Be Made Of Peek/Titanium. The Implants Must Be In Parallel Lordotic & Convex Implants Sets With Height Varyring From 5 Mm-9Mm Implants Must Have On One Step Locking Screw & Screw Angulation Must 40° & 5° Increase & Decrease Should Have Option For 2 Screws Isi/Iso/Gmp/ Who/ Usfda Approved. , Cervical Mesh Cage (Titanium) -1 Cervical Round/Over Mesh Cage- Diameter- 10Mm-166 Length-10Mm-100Mm Isi/Iso/Gmp/ Who/ Usfda Approved. , Cervical Interbody Cage (Titanium-1) Anterior Cervical Interbody Cage- Cage Should Be Peek/Titanium Material. Should Have Radiopaque Marker Which Add In Proper Positioning Of Implants Heights 5Mm - 10Mm. Implants Must Have 6º Lordotic Curve. Isi/Iso/Gmp/ Who/ Usfda Approved. , Cervical Plate (Titanium) With Screws-1 Anterior Cervical Locking Plate- -It Should Be Made Commercial Pure Medical Grade Titanium -Profile Of The Plate Must 1.8Mm -2.5Mm -Width Of The Plate 16Mm-17.5Mm Wide. -Screw Must Be Available From 12Mm To 16Mm Length, Self Tapping & Self Drilling & Variable Angel & Fixed Angel Screw Option -Cranial Screw Angulation Must Be 6 Degree. Isi/Iso/Gmp/ Who/ Usfda Approved. , Cervical Expandable Cage (Titanium) -1 Expandable Corpectomy Cage- Expandable Vertebral Body Replacement Cage For Cervical & Upper Thoracic Spine System Should Offer A Variety Of Center Piece Diameter System Should Be Available For Demonstration As Per Need. System Should Have Kyphotic/ Lordotic End Cap Option Of 4, 8 And 15° System Should Have Cage Diameter Form 12Mm, 14Mm, 16Mm With Hight Ranging 18Mm To 60Mm System Should Have Incremental Expansion With Self Locking Feature System Should Have A Self Locking Mechanism System Should Have Ergonomically Designed Instruments Isi/Iso/Gmp/ Who/ Usfda Approved. , Standalone Cervical Expandable Cage ( Titanium ) (With Inbuilt Screw ,Plate And Expandable Cage ) Isi/Iso/Gmp/ Who/ Usfda Approved. , Odontoid Screw-1 Odontoid Screw- Screw Should Be Made Up Of Titanium Alloy Screw Should Be Cannulated & Self Drilling Screw Should Consist Of 10-12Mm Short Thread Screw Should Be 4Mm Diameter & Length Of 36Mm-50Mm The Whole System Should Be Compatible To Screw Insertion Isi/Iso/Gmp/ Who/ Usfda Approved. , Monoaxial Screw (Titanium)-01 Screw Isi/Iso/Gmp/ Who/ Usfda Approved. , Pedicle Screw (Titanium)-Polyaxial Scerw-01 Screw Polyaxial/Monoaxial Pedicle Screw System The System Must Have In Medical Grade Titanium Alloy. The System Should Be The Pedicle Screw System For Posterior Stabilization Of The T/L Spine System Should Be Low Profile. System Should Be Available In Length Of 35Mm-50Mm & Diameter Should 4.5Mm-75Mm With. The System Must Have Polyaxial Pedicle Screw & Reduction Screw & Transverse Bars With Various Length. System Must Have The Option Of The Rod 5.5/6Mm Pediatrics Pedicle Screw (Titanium)- Polyaxial Screw - Should Be In Different Diameter (4/4.5/5/5.5 Mm) Diameter. It Should Have Small Head/Tulip. Isi/Iso/Gmp/ Who/ Usfda Approved. , Pediatrics Pedical Screw (Titanium) Polyaxial Screw-1 Screw- (4/4.5/5/5.5Mm Diameter; Small Head/Tulip) Polyaxial/Monoaxial Pedicle Screw System The System Must Have In Medical Grade Titanium Alloy. The System Should Be The Pedicle Screw System For Posterior Stabilization Of The T/L Spine System Should Be Low Profile. System Should Be Available In Length Of 35Mm-50Mm & Diameter Should 4.5Mm-75Mm With. The System Must Have Polyaxial Pedicle Screw & Reduction Screw & Transverse Bars With Various Length. System Must Have The Option Of The Rod 5.5/6Mm Pediatrics Pedicle Screw (Titanium)- Polyaxial Screw - Should Be In Different Diameter (4/4.5/5/5.5 Mm) Diameter. It Should Have Small Head/Tulip. Isi/Iso/Gmp/ Who/ Usfda Approved. , Reduction Screw (Titanium )- 1 Screw Isi/Iso/Gmp/ Who/ Usfda Approved. , Rod-1 Isi/Iso/Gmp/ Who/ Usfda Approved. , Transforaminal Lumbar Interbody Fusion (Tlif) / Posterior Lumber Interbody Fusion (Plif) Cage- 01 Cage Plif/Tlif Cage -The Implant Must Be Radiolucent Made Up Of Peek- Material With Sharp Serrated Edge -The Implants Should Have Range Of Height 8Mm-15Mm In 1Mm Incremental To According Patient Anatomy -The Implants Have Marker To Indicate Cage Position On X-Ray The Implants Must Have A Bone Graft Window. - The Implants Available In 22Mm, 26Mm & 32Mm Length Isi/Iso/Gmp/ Who/ Usfda Approved. , Ha Coated Titanium Polyaxial Pedicle Screw-01 Screw Isi/Iso/Gmp/ Who/ Usfda Approved. , Canulated Titanium Pedicle Screw (For Osteoporotic Bone ) -1 Isi/Iso/Gmp/ Who/ Usfda Approved. , Kyphoplasty / Vertibroplasty Bone Cement -(For Cannulated Screw Osteoporotic Bone)-1 Isi/Iso/Gmp/ Who/ Usfda Approved. , Titanium Polyaxial Iliac Screw-01 Screw Isi/Iso/Gmp/ Who/ Usfda Approved. , Transverse Connector-1 Isi/Iso/Gmp/ Who/ Usfda Approved. , Percutaneus Rods (Titanium) (Pre Screw) -Provided With Set Percutaneous Pedicle Screw Fixation System The System Should Have Single & Multiple Level Capability. The System Should Have Polyaxial/ Monoaxial Screw With Top Loading Locking Mechanism. Implants Should Be Cannulated Poly Axial With 4.5, 5.5 & 6.5Mm Dia Screw For Percutaneous Thoraculumber Fixation With Break Off Set Screw. System Should Have Rod Option For Precut & Prebend & Straight Of Different Sizes. System Should Have Free Hand Rod Inserter Instruments. System Should Have For Measuring & Rod Confirmation Tool Which Help To Surgeon To Check The Insertion Of The Rod On To The Screw Percutaneously. System Should Provide Method Of Compression & Distraction. System Should Have Cannulated Instruments For Ease Of Working On Guide Wire The System Should Have Reverse Threaded Technology To Reduce Pullout Strength. Implants Should Be Top Loading, Top Tightening & Most Importantly Reverse Thread Technology With Break Off Plugs. System Should Compatible With 5.5Mm Diameter Rod. System Should Be Available For Demonstration As Per The Requirement. Isi/Iso/Gmp/ Who/ Usfda Approved. , Percutaneus Screw (Titanium) (Pre Screw) -Provided With Set Percutaneous Pedicle Screw Fixation System The System Should Have Single & Multiple Level Capability. The System Should Have Polyaxial/ Monoaxial Screw With Top Loading Locking Mechanism. Implants Should Be Cannulated Poly Axial With 4.5, 5.5 & 6.5Mm Dia Screw For Percutaneous Thoraculumber Fixation With Break Off Set Screw. System Should Have Rod Option For Precut & Prebend & Straight Of Different Sizes. System Should Have Free Hand Rod Inserter Instruments. System Should Have For Measuring & Rod Confirmation Tool Which Help To Surgeon To Check The Insertion Of The Rod On To The Screw Percutaneously. System Should Provide Method Of Compression & Distraction. System Should Have Cannulated Instruments For Ease Of Working On Guide Wire The System Should Have Reverse Threaded Technology To Reduce Pullout Strength. Implants Should Be Top Loading, Top Tightening & Most Importantly Reverse Thread Technology With Break Off Plugs. System Should Compatible With 5.5Mm Diameter Rod. System Should Be Available For Demonstration As Per The Requirement. Isi/Iso/Gmp/ Who/ Usfda Approved. , Single Baloon Kyphoplasty With Cement-1 Kyphoplasty & Vertebroplasty Kit- System Should Be Available For Demonstration As Per The Requirement The Kit Should Be Available In Pre Sterile Packing. Should Have Working Cannula With Inner Diameter 3.2Mm Or Less Outer Diameter 4.2Mm Or More With Calibration Along With Cannulated Obdurator. Should Have Calibrated Drill With Cm/Mm Marking On Proximal End. Should Have Inflation Syringe To Inflate The Balloon Showing Pressure In Psi & Atm. Inflation Time & Volume Of Cavity Created In Vertebral Body. The Inflatable Balloon Tamps Sizes- 10/3, 15/3, 20/3. (Either Size) Should Be Capable To Bear Pressure Of 350-400 Psi. The Bone Filler Device Should Be Calibrated & Should Contain Minimum 2Cc Of Volume. Anterior Radiopaque Marker On Balloon Tamp Should Be Mark The Anterior Edge Of The Balloon. System Component Should Be Available In Individually As Well As In Kit From Including The Following Instruments- 1. 2 Unit Of 11 Gauge Bone Access Needle. 2. 1 Introducer Kit Including Introducer With Extra Cannula. 3.Drill With Drill Tip. 4. At Least 4 Guide Pins. 5. Two Balloon Tamp 6. 2 Digital Balloon Inflator. 7. Six Bone Filler Device. Isi/Iso/Gmp/ Who/ Usfda Approved. , Double Baloon Kyphoplasty With Cement-1 Kyphoplasty & Vertebroplasty Kit- System Should Be Available For Demonstration As Per The Requirement The Kit Should Be Available In Pre Sterile Packing. Should Have Working Cannula With Inner Diameter 3.2Mm Or Less Outer Diameter 4.2Mm Or More With Calibration Along With Cannulated Obdurator. Should Have Calibrated Drill With Cm/Mm Marking On Proximal End. Should Have Inflation Syringe To Inflate The Balloon Showing Pressure In Psi & Atm. Inflation Time & Volume Of Cavity Created In Vertebral Body. The Inflatable Balloon Tamps Sizes- 10/3, 15/3, 20/3. (Either Size) Should Be Capable To Bear Pressure Of 350-400 Psi. The Bone Filler Device Should Be Calibrated & Should Contain Minimum 2Cc Of Volume. Anterior Radiopaque Marker On Balloon Tamp Should Be Mark The Anterior Edge Of The Balloon. System Component Should Be Available In Individually As Well As In Kit From Including The Following Instruments- 1. 2 Unit Of 11 Gauge Bone Access Needle. 2. 1 Introducer Kit Including Introducer With Extra Cannula. 3.Drill With Drill Tip. 4. At Least 4 Guide Pins. 5. Two Balloon Tamp 6. 2 Digital Balloon Inflator. 7. Six Bone Filler Device. Isi/Iso/Gmp/ Who/ Usfda Approved. , Vertebroplasty Set With Cement-1 Kyphoplasty & Vertebroplasty Kit- System Should Be Available For Demonstration As Per The Requirement The Kit Should Be Available In Pre Sterile Packing. Should Have Working Cannula With Inner Diameter 3.2Mm Or Less Outer Diameter 4.2Mm Or More With Calibration Along With Cannulated Obdurator. Should Have Calibrated Drill With Cm/Mm Marking On Proximal End. Should Have Inflation Syringe To Inflate The Balloon Showing Pressure In Psi & Atm. Inflation Time & Volume Of Cavity Created In Vertebral Body. The Inflatable Balloon Tamps Sizes- 10/3, 15/3, 20/3. (Either Size) Should Be Capable To Bear Pressure Of 350-400 Psi. The Bone Filler Device Should Be Calibrated & Should Contain Minimum 2Cc Of Volume. Anterior Radiopaque Marker On Balloon Tamp Should Be Mark The Anterior Edge Of The Balloon. System Component Should Be Available In Individually As Well As In Kit From Including The Following Instruments- 1. 2 Unit Of 11 Gauge Bone Access Needle. 2. 1 Introducer Kit Including Introducer With Extra Cannula. 3.Drill With Drill Tip. 4. At Least 4 Guide Pins. 5. Two Balloon Tamp 6. 2 Digital Balloon Inflator. 7. Six Bone Filler Device. Isi/Iso/Gmp/ Who/ Usfda Approved. , Craneoplasty (Titanium) Plate With Screw With 4 Mini Plate And Screw-01 Set Cranioplasty Mesh (Titanium) With Mini-Plate And Screw Made Of Medical-Grade Titanium; Excellent Biocompatibility, Corrosion Resistance Mesh Pattern / Pore Size: Perforated Or Expanded Mesh; Pore Size: 1.5-3.0 Mm Sizes: 50 X 50 Mm; 100 X 100 Mm; 150 X 150 Mm Mechanical Properties: High Tensile Strength; Good Malleability, Easily Contoured Intra-Operatively; Maintains Shape After Fixation; Resistant To Fatigue And Deformation Mri & Imaging Compatibility: Mri Conditional / Mri Safe Compatible Up To 3 Tesla Minimal Artifact On: Ct/Mri Fixation Compatibility: Compatible With Titanium Screws (1.5-2.0 Mm)&Cranial Fixation Systems; Can Be Cut With Standard Mesh Scissors Isi/Iso/Gmp/ Who/ Usfda Approved. , Cranioplasty Mesh Titanium With Mini Plate And Screw -01 Set Cranioplasty Mesh (Titanium) With Mini-Plate And Screw Made Of Medical-Grade Titanium; Excellent Biocompatibility, Corrosion Resistance Mesh Pattern / Pore Size: Perforated Or Expanded Mesh; Pore Size: 1.5-3.0 Mm Sizes: 50 X 50 Mm; 100 X 100 Mm; 150 X 150 Mm Mechanical Properties: High Tensile Strength; Good Malleability, Easily Contoured Intra-Operatively; Maintains Shape After Fixation; Resistant To Fatigue And Deformation Mri & Imaging Compatibility: Mri Conditional / Mri Safe Compatible Up To 3 Tesla Minimal Artifact On: Ct/Mri Fixation Compatibility: Compatible With Titanium Screws (1.5-2.0 Mm)&Cranial Fixation Systems; Can Be Cut With Standard Mesh Scissors Isi/Iso/Gmp/ Who/ Usfda Approved. , Aneurysm Clip ( Pre Clip) Should Provide Complete Set Including All Sizes And Shapes Of Permanent And Temporary Clips Size 5,7,9,10,Mm Straight, And Bayonet 90 Degree,Fenestrated U Shaped Aneurysm Clip Straight, Curved, Angled, Bayonet, Fenestrated, T-Bar, Tandem, Temporary, Permanent Titanium Alloy;Mr Compatibilityup To 3 Tesla Spring-Loaded Titanium Clips Available In Straight, Curved, Angled, And Fenestrated Configurations, With Blade Lengths Ranging From 5-12 Mm Minimal Scissoring Of Blades High Fatigue Resistance Biocompatibility And Corrosion Resistance Minimal Ct/Mri Artifact Isi/Iso/Gmp/ Who/ Usfda Approved. , Hudson Brace With Burr And Perforator (Stainless Steel ,, 4 Peraforator+ 4 Burr Different Sizes) Isi/Iso/Gmp/ Who/ Usfda Approved. , Gigli Saw Wire - High Quality Steel .Sharp .04 Mm Thick Isi/Iso/Gmp/ Who/ Usfda Approved. , Demartels Gigli Saw Wire Guide Isi/Iso/Gmp/ Who/ Usfda Approved. , Monopolar Cautery Point Isi/Iso/Gmp/ Who/ Usfda Approved. , Bipolar Cautery Cord Isi/Iso/Gmp/ Who/ Usfda Approved. , Cast Padding Roll (Soft Roll) Isi/Iso/Gmp/ Who/ Usfda Approved. , Formalin Tablet Isi/Iso/Gmp/ Who/ Usfda Approved. , Vp Shunt- -Medium Isi/Iso/Gmp/ Who/ Usfda Approved. , Vp Shunt- Low Isi/Iso/Gmp/ Who/ Usfda Approved. , Vp Shunt- High Isi/Iso/Gmp/ Who/ Usfda Approved. , Omaya Reservoir With Ventricular End Isi/Iso/Gmp/ Who/ Usfda Approved. , External Ventricular Drainage Set (Evd) Isi/Iso/Gmp/ Who/ Usfda Approved. , Thecoperitoneal Shunt Isi/Iso/Gmp/ Who/ Usfda Approved. , Craniotomy Drape Isi/Iso/Gmp/ Who/ Usfda Approved. , Laminectomy Drape Isi/Iso/Gmp/ Who/ Usfda Approved. , Vp Shunt Drape Isi/Iso/Gmp/ Who/ Usfda Approved. , Neuro Surgical Pattis Isi/Iso/Gmp/ Who/ Usfda Approved. , Merocele Nasal Packing Isi/Iso/Gmp/ Who/ Usfda Approved. , Hemopatch Isi/Iso/Gmp/ Who/ Usfda Approved. , G-Patch Isi/Iso/Gmp/ Who/ Usfda Approved. , Autoclave Label (Signoflam) Isi/Iso/Gmp/ Who/ Usfda Approved. , Shunt Tunneler Pediatric Isi/Iso/Gmp/ Who/ Usfda Approved. , Shunt Tunneler Adult Isi/Iso/Gmp/ Who/ Usfda Approved. , Ventricular Puncture Needle Isi/Iso/Gmp/ Who/ Usfda Approved. , Philadelphia Collar-Small Isi/Iso/Gmp/ Who/ Usfda Approved. , Philadelphia Collar- Medium Isi/Iso/Gmp/ Who/ Usfda Approved. , Philadelphia Collar- Large Isi/Iso/Gmp/ Who/ Usfda Approved. , Taylors Brace (Dl Belt)- Small Isi/Iso/Gmp/ Who/ Usfda Approved. , Taylors Brace (Dl Belt)- Medium Isi/Iso/Gmp/ Who/ Usfda Approved. , Taylors Brace (Dl Belt)- Large Isi/Iso/Gmp/ Who/ Usfda Approved. , Lumbosacral (Ls Belt)-Small Isi/Iso/Gmp/ Who/ Usfda Approved. , Lumbosacral (Ls Belt)-Medium Isi/Iso/Gmp/ Who/ Usfda Approved. , Lumbosacral (Ls Belt)- Large Isi/Iso/Gmp/ Who/ Usfda Approved. , Soft Cervical Collar-Small Isi/Iso/Gmp/ Who/ Usfda Approved. , Soft Cervical Collar-Medium Isi/Iso/Gmp/ Who/ Usfda Approved. , Soft Cervical Collar-Large Isi/Iso/Gmp/ Who/ Usfda Approved. , Endoscopic Esophageal Sems Nitinol Material; Looped Stent Flare Ends With Retrieval Loop On Prosimal End; Upto 75% Reconstrainable; 4 Ro Positioning Markers Usfda Approved. , Endoscopic Esophageal Sems Single Stranded Nitinol Material; High Tensile Suture Release; Proosimal And Distal Release Options; Post Deployment Endoscopic And Ro Markers; Scope Caliberation On Stent Catheter Usfda Approved. , Endoscopic Removable Esophageal Stent For Benign Indications Polyester Braided Encapsulated With Sillicon; Sizes 9,12 Or 15 Cm; 3 Ro And 3 Endoxcopic Markers Usfda Approved. , Endoxcopic Pyloricsems 10Fr. Through The Scope Or Over The Wire Delivery System; Nitinol Material; Looped Ends Of Stent, 3 Ro Positioning Markers; 70% Reconstrainablility Usfda Approved. , Endoxcopic Colonic Sems 10Fr. Through The Scope Or Over The Wire Delivery System; Nitinol Material; Looped Ends Of Stent, 3 Ro Positioning Markers; 70% Reconstrainablility Usfda Approved. , Endoxcopic Biliary Sems Platinol Material; Upto 87% Reconstrainable; 3 Ro Markers; Clear Distal Tip; Yellow Endoscopic Transition Zone; Close Cell Geometry With Looped Ends Of Stent Usfda Approved. , Endoxcopic Biliary Sems Platinol Material; Upto 87% Reconstrainable; 3 Ro Markers; Clear Distal Tip; Yellow Endoscopic Transition Zone; Close Cell Geometry With Looped Ends Of Stent; Fully Covered Option Indicated For Benign Indications Also Usfda Approved. , Endoscopic Removable Biliary Stent For Benign Indications Thin Wall Design; 7Fr & 10Fr With 5, 7, 10, 12, 15 Cm Lengths; Radio Opaque Bio Compatible Material; Barbed Ends For Anchoring Usfda Approved. , Endoscopic Removable Biliary Stent For Benign Indications Thin Wall Design; 7Fr & 10Fr With 5, 7, 10, 15 Cm Lengths; Radio Opaque Bio Compatible Material; Pig Tail Ends For Anchoring Usfda Approved. , Endoscopic Sphinctrotome Triple Lumen; 20Mm Cut Wire; 5.5Fr Tip Size; Off Centric Monofilament Cut Wire Usfda Approved. , Endoscopic Needle Knife Triple Lumen; Off Centric Monofilament Cut Wire With Exposure 1Mm To 6Mm, Tip Taper From 7Fr-5Fr Usfda Approved. , Endoscopic Stone Retrieval Basket Pre Cursor Alloy Material; Silver Tip Technology To Avoid Basket Impaction; Can Be Used For Performing Mechanical Lithotripsy Using A Lithotriptor Usfda Approved. , Endoscopic Stone Retrieval Balloon Priple Lumen; Injection Above/Below; Two Distinct Diameters 9-12Mm, 12-15Mm, 15-18Mm; Square Shoulder Balloon; Proximal Ro Markers Usfda Approved. , Endoscopic Dilatation Balloon Indicated For Esophageal, Pyloric, Colonic And Biliary Use (Sphinctroplasty); Pebax Non Compliant Material; 3 Distinct Diameters At 3 Distinct Pressures; Rounded Shoulders; Clear Material For Visualization Size12-15Mm,15-18 Mm, 18-20Mm Usfda Approved. , Endoscopic Biliary Dilatation Balloon Hydrophilic Dilatation Baloon; 4Fr. Tip; Langths 2 And 4 Cm; 4, 6, 8, 10Mm Diameter Sizes; 2 Ro Positioning Markers Usfda Approved. , Endoscopic Ultrasound Needle Cobalt Dhromium Material For 22 & 25 Ga And Nitinal Material For 19 Flesible; Customized Needle Sheath; Echogenic Pattern Till Needle Tip; Sharp Tip Grind Usfda Approved. , Guide Wire 0.035 Tip (J-Trip & Straight Trip) Wire With 260 Cm, 420 Cm And 450Cm Working Length With Tip Of 0.025 Exchange Guidewire Hydrophilic Tip ; Kink Resistant Nitinol Standard And Stiff Shaft;; 10 Cm Hydrophillic Tip Usfda Approved. , Endoscopic Biopsy Forceys Usfda Approved. , Mechanical Lithotryptor Usfda Approved. , Multiband Ligatornon Latex Material, Clear Ligating Barrel With Rear Mounted Bands; Single Strand Deployment; Square Band Design For High Retention Usfda Approved. , Hemoclip Applicator Usfda Approved. , Loop Grasper Usfda Approved.. , Hemo Spray Usfda Approved. , Co2 Insufflater Usfda Approved. , Water Jet Irrigalien Set Usfda Approved. , Dormia Basket Usfda Approved.. , Tapezoid Stone Crushing Basket Usfda Approved. , Oasis System For Endoscopic Billiary Stent Insetion Usfda Approved. Total In Figures 0.0 0.0 98.0 0.0 0.0 0.0 0.0 0.0 Inr Zero Only 4.0 Construction Of Chamber For 100Mm Sluice Plates Item5 10.0 Nos Quoted Rate In Figures Select % 0.0 0.0 Zero Only Quoted Rate In Words
BOQ
| Sl. No. | Item Description |
| 1 | Item Wise BoQ BoQ_Ver3.0 Item Wise Normal INR Only INR Select, Excess (+), Less (-) Tender Inviting Authority: Member Secretary, RMRS, PBM Hospital,Bikaner Name of Work: Supply of materials/medicines for patients of the Neurosurgery Department and others in the hospital, under the Mukhyamantri Nishulk Nirogi Rajasthan Yojana, M-AAY, and RGHS schemes, Short-term Rate Contract for 2 Year Contract No: SOENIB 13 ( 2026-27) Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # S.No. Item Name / Quantity Item Code / Make Quantity Unit Estimated Rate Make Packing Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Each Rate Without Tax Rs. P Excise Duty GST in Figures to be entered by the Bidder Rs. Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without GST TOTAL AMOUNT With GST TOTAL AMOUNT In Words |
| 2 | Cervical C1-C2 lateral mass Screw with plate/ rod (Titanium)- 1 set (2 Screw titanium)Lateral mass & occipitocervical module-Three-in-one Set of options that provide adjustability, flexibility & adaptability to accommodate for anatomical challenge within occipitocervical spineSystem implant should give surgeon choice of adjustable OC plate, midline plate, rod screws & screw connector.System should have polyaxial lateral mass screw in 3.5mm & 4.0mm Diameter & length should 10mm to 36mm with 2mm increment. System should have reverse- angle design & 45 degree angulation with smooth tulip head system should adjustable occipital plate between the two rods System should have cortical bone Screw in sizes 4mm, 4.5mm & 5mm dia & length 6mm to 12mm with 2mm increment System should have laterial offset connector accommodate medical - laterial flexibility in challenging rod/screw alignment situation.system should have hooks in the set system should have transverse connector System should be available for demonstration as per the requirement. ISI/ISO/GMP/ WHO/ USFDA |
| 3 | Occipital Plate (Titanium) with screw (Titanium) and connector- 1 setLateral mass & occipitocervical module-Three-in-one Set of options that provide adjustability, flexibility & adaptability to accommodate for anatomical challenge within occipitocervical spineSystem implant should give surgeon choice of adjustable OC plate, midline plate, rod screws & screw connector.System should have polyaxial lateral mass screw in 3.5mm & 4.0mm Diameter & length should 10mm to 36mm with 2mm increment. System should have reverse- angle design & 45 degree angulation with smooth tulip head system should adjustable occipital plate between the two rods System should have cortical bone Screw in sizes 4mm, 4.5mm & 5mm dia & length 6mm to 12mm with 2mm increment System should have laterial offset connector accommodate medical - laterial flexibility in challenging rod/screw alignment situation.system should have hooks in the set system should have transverse connector System should be available for demonstration as per the requirement. ISI/ISO/GMP/ WHO/ USFDA approved. |
| 4 | Sub axial Cervical lateral mass screw (Titanium)- 1 Screw rate ISI/ISO/GMP/ WHO/ USFDA approved. |
| 5 | Titanium Rod ( 01 set- 02 rods) ISI/ISO/GMP/ WHO/ USFDA approved. |
| 6 | Titanium cervico - dorsal tapered rod ( 01 set- 02 rods) ISI/ISO/GMP/ WHO/ USFDA approved. |
| 7 | C1 C2 Spacer (Titanium3,5 mm X 8mm Height)-1 ISI/ISO/GMP/ WHO/ USFDA approved. |
| 8 | Lateral off set Connector-1 ISI/ISO/GMP/ WHO/ USFDA approved. |
| 9 | Domino's (compatible to connect 3.5/5.5mm rods)-1 ISI/ISO/GMP/ WHO/ USFDA approved. |
| 10 | Titanium Standalone cage with inbuilt screws-1Anterior cervical interbody fusion device with screw (Stand alone cage)The implants should be made from Titanium/radiolucent PEEKThe implants should be stand alone interbody fusion device for C-spineSoacer component must be made of PEEK/TITANIUM.The implants must be in parallel lordotic & convex implants sets with height varyring from 5 mm-9mmImplants must have on one step locking screw & screw angulation must 40° & 5° increase & decrease Should have option for 2 Screws ISI/ISO/GMP/ WHO/ USFDA approved. |
| 11 | Cervical Mesh cage (Titanium) -1Cervical Round/Over Mesh cage-Diameter- 10mm-166Length-10mm-100mm ISI/ISO/GMP/ WHO/ USFDA approved. |
| 12 | Cervical Interbody cage (Titanium-1)Anterior Cervical interbody cage-Cage should be PEEK/TITANIUM material.Should have Radiopaque marker which add in proper positioning of implants heights 5mm -10mm.Implants must have 6º lordotic curve. ISI/ISO/GMP/ WHO/ USFDA approved. |
| 13 | Cervical Plate (Titanium) with Screws-1 Anterior cervical locking plate--It should be made commercial pure medical grade Titanium-Profile of the plate must 1.8mm -2.5mm-Width of the plate 16mm-17.5mm wide.-Screw must be available from 12mm to 16mm length, self tapping & self drilling & variable angel & fixed angel screw option-cranial screw angulation must be 6 degree. ISI/ISO/GMP/ WHO/ USFDA approved. |
| 14 | Cervical expandable cage (Titanium) -1Expandable Corpectomy cage-Expandable Vertebral body Replacement cage for cervical & upper thoracic spine System should offer a variety of center piece DiameterSystem should be available for demonstration as per need.System should have kyphotic/ lordotic End Cap option of 4\\", 8\\" and 15°System should have cage diameter form 12mm, 14mm, 16mm with hight ranging 18mm to60mm System should have incremental expansion with self locking featureSystem should have a self locking mechanismSystem should have ergonomically designed instruments ISI/ISO/GMP/ WHO/ USFDA approved. |
| 15 | Standalone Cervical expandable cage ( Titanium ) (with inbuilt screw ,plate and expandable cage ) ISI/ISO/GMP/ WHO/ USFDA approved. |
| 16 | Odontoid Screw-1Odontoid screw-Screw should be made up of Titanium AlloyScrew should be cannulated & self drillingScrew should consist of 10-12mm short threadScrew should be 4mm Diameter & length of 36mm-50mmThe whole system should be compatible to screw insertion ISI/ISO/GMP/ WHO/ USFDA approved. |
| 17 | Monoaxial Screw (Titanium)-01 screw ISI/ISO/GMP/ WHO/ USFDA approved. |
| 18 | Pedicle Screw (Titanium)-polyaxial Scerw-01 screwPolyaxial/Monoaxial pedicle screw systemThe system must have in medical grade Titanium alloy.The system should be The pedicle screw system for posterior stabilization of the T/L spine System should be low profile.System should be available in length of 35mm-50mm & Diameter should 4.5mm-75mm with.The system must have Polyaxial pedicle screw & reduction screw & transverse bars with various length.System must have the option of the rod 5.5/6mmPediatrics Pedicle Screw (Titanium)- Polyaxial Screw - should be in different diameter (4/4.5/5/5.5 mm) Diameter. It should have Small Head/Tulip. ISI/ISO/GMP/ WHO/ USFDA approved. |
| 19 | Pediatrics Pedical screw (Titanium) Polyaxial screw-1 Screw- (4/4.5/5/5.5mm diameter; small Head/tulip)Polyaxial/Monoaxial pedicle screw systemThe system must have in medical grade Titanium alloy.The system should be The pedicle screw system for posterior stabilization of the T/L spine System should be low profile.System should be available in length of 35mm-50mm & Diameter should 4.5mm-75mm with.The system must have Polyaxial pedicle screw & reduction screw & transverse bars with various length.System must have the option of the rod 5.5/6mmPediatrics Pedicle Screw (Titanium)- Polyaxial Screw - should be in different diameter (4/4.5/5/5.5 mm) Diameter. It should have Small Head/Tulip. ISI/ISO/GMP/ WHO/ USFDA approved. |
| 20 | Reduction Screw (Titanium )- 1 Screw ISI/ISO/GMP/ WHO/ USFDA approved. |
| 21 | Rod-1 ISI/ISO/GMP/ WHO/ USFDA approved. |
| 22 | Transforaminal Lumbar Interbody Fusion (TLIF) / Posterior Lumber interbody Fusion (PLIF) cage- 01 cagePLIF/TLIF Cage-The implant must be radiolucent made up of PEEK- material with sharp serrated edge-The implants should have range of height 8mm-15mm in 1mm incremental to according patient anatomy -The implants have marker to indicate cage position on x-rayThe Implants must have a bone graft window.- The implants available in 22mm, 26mm & 32mm length ISI/ISO/GMP/ WHO/ USFDA approved. |
| 23 | HA Coated titanium polyaxial pedicle screw-01 screw ISI/ISO/GMP/ WHO/ USFDA approved. |
| 24 | Canulated titanium pedicle screw (for Osteoporotic bone ) -1 ISI/ISO/GMP/ WHO/ USFDA approved. |
| 25 | kyphoplasty / vertibroplasty bone cement -(for cannulated Screw osteoporotic bone)-1 ISI/ISO/GMP/ WHO/ USFDA approved. |
| 26 | Titanium polyaxial iliac screw-01 screw ISI/ISO/GMP/ WHO/ USFDA approved. |
| 27 | Transverse connector-1 ISI/ISO/GMP/ WHO/ USFDA approved. |
| 28 | Percutaneus Rods (Titanium) (pre screw) -Provided with setPercutaneous pedicle screw fixation systemThe system should have single & multiple level capability.The system should have Polyaxial/ Monoaxial screw with top loading locking mechanism. Implants should be cannulated poly axial with 4.5, 5.5 & 6.5mm dia screw for percutaneousthoraculumber fixation with break off set screw.System should have rod option for precut & prebend & straight of different sizes.System should have free hand rod inserter instruments.System should have for measuring & rod confirmation tool which help to surgeon to check the insertion of the rod on to the screw percutaneously.System should provide method of compression & distraction.System should have cannulated instruments for ease of working on guide wire The system should have reverse threaded technology to reduce pullout strength.Implants should be top loading, top tightening & most importantly reverse thread technology with break off plugs.System should compatible with 5.5mm diameter rod.System should be available for demonstration as per the requirement. ISI/ISO/GMP/ WHO/ USFDA approved. |
| 29 | Percutaneus Screw (Titanium) (pre screw) -Provided with set Percutaneous pedicle screw fixation system The system should have single & multiple level capability.The system should have Polyaxial/ Monoaxial screw with top loading locking mechanism. Implants should be cannulated poly axial with 4.5, 5.5 & 6.5mm dia screw for percutaneousthoraculumber fixation with break off set screw.System should have rod option for precut & prebend & straight of different sizes.System should have free hand rod inserter instruments.System should have for measuring & rod confirmation tool which help to surgeon to check the insertion of the rod on to the screw percutaneously.System should provide method of compression & distraction.System should have cannulated instruments for ease of working on guide wire The system should have reverse threaded technology to reduce pullout strength.Implants should be top loading, top tightening & most importantly reverse thread technology with break off plugs.System should compatible with 5.5mm diameter rod.System should be available for demonstration as per the requirement. ISI/ISO/GMP/ WHO/ USFDA approved. |
| 30 | Single Baloon Kyphoplasty With Cement-1Kyphoplasty & Vertebroplasty kit-System should be available for demonstration as per the requirementThe Kit should be available in pre sterile packing.Should have working cannula with inner diameter 3.2mm or less outer diameter 4.2mm or more with calibration along with cannulated obdurator.Should have calibrated drill with cm/mm marking on proximal end.Should have inflation syringe to inflate the balloon showing pressure in PSI & ATM.Inflation time & volume of cavity created in vertebral body.The inflatable balloon tamps sizes- 10/3, 15/3, 20/3. (Either size) should be capable to bear pressure of 350-400 PSI.The bone filler device should be calibrated & should contain minimum 2cc of volume.Anterior Radiopaque marker on balloon tamp should be Mark the anterior edge of the balloon.System component should be available in individually as well as in kit from including the following instruments-1. 2 unit of 11 gauge bone access needle.2. 1 introducer kit including introducer with extra cannula.3.Drill with drill tip.4. At least 4 guide pins.5. Two balloon tamp6. 2 digital balloon inflator.7. Six bone filler device. ISI/ISO/GMP/ WHO/ USFDA approved. |
| 31 | Double Baloon Kyphoplasty With Cement-1Kyphoplasty & Vertebroplasty kit-System should be available for demonstration as per the requirementThe Kit should be available in pre sterile packing.Should have working cannula with inner diameter 3.2mm or less outer diameter 4.2mm or more with calibration along with cannulated obdurator.Should have calibrated drill with cm/mm marking on proximal end.Should have inflation syringe to inflate the balloon showing pressure in PSI & ATM.Inflation time & volume of cavity created in vertebral body.The inflatable balloon tamps sizes- 10/3, 15/3, 20/3. (Either size) should be capable to bear pressure of 350-400 PSI.The bone filler device should be calibrated & should contain minimum 2cc of volume.Anterior Radiopaque marker on balloon tamp should be Mark the anterior edge of the balloon.System component should be available in individually as well as in kit from including the following instruments-1. 2 unit of 11 gauge bone access needle.2. 1 introducer kit including introducer with extra cannula.3.Drill with drill tip.4. At least 4 guide pins.5. Two balloon tamp6. 2 digital balloon inflator.7. Six bone filler device. ISI/ISO/GMP/ WHO/ USFDA approved. |
| 32 | Vertebroplasty Set With cement-1Kyphoplasty & Vertebroplasty kit-System should be available for demonstration as per the requirementThe Kit should be available in pre sterile packing.Should have working cannula with inner diameter 3.2mm or less outer diameter 4.2mm or more with calibration along with cannulated obdurator.Should have calibrated drill with cm/mm marking on proximal end.Should have inflation syringe to inflate the balloon showing pressure in PSI & ATM.Inflation time & volume of cavity created in vertebral body.The inflatable balloon tamps sizes- 10/3, 15/3, 20/3. (Either size) should be capable to bear pressure of 350-400 PSI.The bone filler device should be calibrated & should contain minimum 2cc of volume.Anterior Radiopaque marker on balloon tamp should be Mark the anterior edge of the balloon.System component should be available in individually as well as in kit from including the following instruments-1. 2 unit of 11 gauge bone access needle.2. 1 introducer kit including introducer with extra cannula.3.Drill with drill tip.4. At least 4 guide pins.5. Two balloon tamp6. 2 digital balloon inflator.7. Six bone filler device. ISI/ISO/GMP/ WHO/ USFDA approved. |
| 33 | Craneoplasty (Titanium) plate with screw with 4 mini plate and screw-01 setCranioplasty Mesh (Titanium) with Mini-plate and ScrewMade of Medical-grade Titanium; Excellent Biocompatibility, Corrosion resistanceMesh Pattern / Pore Size: Perforated or expanded mesh; Pore size: 1.5-3.0 mmSizes: 50 x 50 mm; 100 x 100 mm; 150 x 150 mmMechanical Properties: High tensile strength; Good malleability, Easily contoured intra-operatively; Maintains shape after fixation; Resistant to fatigue and deformationMRI & Imaging Compatibility: MRI Conditional / MRI Safe Compatible up to 3 TeslaMinimal artifact on: CT/MRIFixation Compatibility: Compatible with Titanium screws (1.5-2.0 mm)&Cranial fixation systems; Can be cut with standard mesh scissors ISI/ISO/GMP/ WHO/ USFDA approved. |
| 34 | Cranioplasty mesh Titanium with mini plate and screw -01 set Cranioplasty Mesh (Titanium) with Mini-plate and ScrewMade of Medical-grade Titanium; Excellent Biocompatibility, Corrosion resistanceMesh Pattern / Pore Size: Perforated or expanded mesh; Pore size: 1.5-3.0 mmSizes: 50 x 50 mm; 100 x 100 mm; 150 x 150 mmMechanical Properties: High tensile strength; Good malleability, Easily contoured intra-operatively; Maintains shape after fixation; Resistant to fatigue and deformationMRI & Imaging Compatibility: MRI Conditional / MRI Safe Compatible up to 3 TeslaMinimal artifact on: CT/MRIFixation Compatibility: Compatible with Titanium screws (1.5-2.0 mm)&Cranial fixation systems; Can be cut with standard mesh scissors ISI/ISO/GMP/ WHO/ USFDA approved. |
| 35 | Aneurysm Clip ( pre clip) should provide complete set including all sizes and shapes of permanent and Temporary Clips size 5,7,9,10,mm Straight, and Bayonet 90 degree,fenestrated 'U' shapedAneurysm clipStraight, curved, angled, bayonet, fenestrated, T-bar, tandem, temporary, permanentTitanium alloy;MR compatibilityup to 3 TeslaSpring-loaded titanium clips available in straight, curved, angled, and fenestrated configurations, with blade lengths ranging from 5-12 mmMinimal scissoring of bladesHigh fatigue resistanceBiocompatibility and corrosion resistanceMinimal CT/MRI artifact ISI/ISO/GMP/ WHO/ USFDA approved. |
| 36 | Hudson brace with burr and Perforator (Stainless steel ,, 4 peraforator+ 4 burr different sizes) ISI/ISO/GMP/ WHO/ USFDA approved. |
| 37 | Gigli saw wire - High quality steel .sharp .04 mm thick ISI/ISO/GMP/ WHO/ USFDA approved. |
| 38 | Demartel's gigli saw wire guide ISI/ISO/GMP/ WHO/ USFDA approved. |
| 39 | Monopolar cautery point ISI/ISO/GMP/ WHO/ USFDA approved. |
| 40 | Bipolar cautery cord ISI/ISO/GMP/ WHO/ USFDA approved. |
| 41 | cast padding roll (soft roll) ISI/ISO/GMP/ WHO/ USFDA approved. |
| 42 | Formalin tablet ISI/ISO/GMP/ WHO/ USFDA approved. |
| 43 | VP shunt- -Medium ISI/ISO/GMP/ WHO/ USFDA approved. |
| 44 | VP shunt- Low ISI/ISO/GMP/ WHO/ USFDA approved. |
| 45 | VP shunt- High ISI/ISO/GMP/ WHO/ USFDA approved. |
| 46 | Omaya reservoir with ventricular end ISI/ISO/GMP/ WHO/ USFDA approved. |
| 47 | External ventricular Drainage set (EVD) ISI/ISO/GMP/ WHO/ USFDA approved. |
| 48 | Thecoperitoneal shunt ISI/ISO/GMP/ WHO/ USFDA approved. |
| 49 | Craniotomy drape ISI/ISO/GMP/ WHO/ USFDA approved. |
| 50 | Laminectomy drape ISI/ISO/GMP/ WHO/ USFDA approved. |
| 51 | Vp shunt Drape ISI/ISO/GMP/ WHO/ USFDA approved. |
| 52 | Neuro surgical patti's ISI/ISO/GMP/ WHO/ USFDA approved. |
| 53 | Merocele nasal packing ISI/ISO/GMP/ WHO/ USFDA approved. |
| 54 | Hemopatch ISI/ISO/GMP/ WHO/ USFDA approved. |
| 55 | G-patch ISI/ISO/GMP/ WHO/ USFDA approved. |
| 56 | Autoclave Label (signoflam) ISI/ISO/GMP/ WHO/ USFDA approved. |
| 57 | Shunt Tunneler Pediatric ISI/ISO/GMP/ WHO/ USFDA approved. |
| 58 | Shunt Tunneler Adult ISI/ISO/GMP/ WHO/ USFDA approved. |
| 59 | Ventricular Puncture needle ISI/ISO/GMP/ WHO/ USFDA approved. |
| 60 | Philadelphia collar-Small ISI/ISO/GMP/ WHO/ USFDA approved. |
| 61 | Philadelphia collar- medium ISI/ISO/GMP/ WHO/ USFDA approved. |
| 62 | Philadelphia collar- Large ISI/ISO/GMP/ WHO/ USFDA approved. |
| 63 | Taylor's Brace (DL belt)- small ISI/ISO/GMP/ WHO/ USFDA approved. |
| 64 | Taylor's Brace (DL belt)- medium ISI/ISO/GMP/ WHO/ USFDA approved. |
| 65 | Taylor's Brace (DL belt)- Large ISI/ISO/GMP/ WHO/ USFDA approved. |
| 66 | Lumbosacral (ls belt)-small ISI/ISO/GMP/ WHO/ USFDA approved. |
| 67 | Lumbosacral (ls belt)-medium ISI/ISO/GMP/ WHO/ USFDA approved. |
| 68 | Lumbosacral (ls belt)- large ISI/ISO/GMP/ WHO/ USFDA approved. |
| 69 | Soft cervical collar-small ISI/ISO/GMP/ WHO/ USFDA approved. |
| 70 | Soft cervical collar-medium ISI/ISO/GMP/ WHO/ USFDA approved. |
| 71 | Soft cervical collar-large ISI/ISO/GMP/ WHO/ USFDA approved. |
| 72 | Endoscopic Esophageal SEMSNitinol material; looped stent flare ends with retrieval loop on prosimal end; upto 75% reconstrainable; 4 RO positioning markers USFDA approved. |
| 73 | Endoscopic Esophageal SEMSSingle stranded Nitinol material; high tensile suture release; proosimal and distal release options; post deployment endoscopic and RO markers; scope caliberation on stent catheter USFDA approved. |
| 74 | Endoscopic Removable Esophageal Stent for benign indicationspolyester braided encapsulated with sillicon; sizes 9,12 or 15 cm; 3 RO and 3 endoxcopic markers USFDA approved. |
| 75 | Endoxcopic PyloricSEMS10Fr. Through the scope or over the wire delivery system; nitinol material; looped ends of stent, 3 RO positioning markers; 70% reconstrainablility USFDA approved. |
| 76 | Endoxcopic Colonic SEMS10Fr. Through the scope or over the wire delivery system; nitinol material; looped ends of stent, 3 RO positioning markers; 70% reconstrainablility USFDA approved. |
| 77 | Endoxcopic Biliary SEMSPlatinol Material; upto 87% reconstrainable; 3 RO markers; clear distal tip; yellow endoscopic transition zone; close cell geometry with looped ends of stent USFDA approved. |
| 78 | Endoxcopic Biliary SEMSPlatinol Material; upto 87% reconstrainable; 3 RO markers; clear distal tip; yellow endoscopic transition zone; close cell geometry with looped ends of stent; Fully covered option indicated for benign indications also USFDA approved. |
| 79 | Endoscopic Removable biliary Stent for benign indicationsThin Wall design; 7Fr & 10Fr with 5, 7, 10, 12, 15 cm lengths; radio opaque bio compatible material; barbed ends for anchoring USFDA approved. |
| 80 | Endoscopic Removable biliary Stent for benign indicationsThin Wall design; 7Fr & 10Fr with 5, 7, 10, 15 cm lengths; radio opaque bio compatible material; pig tail ends for anchoring USFDA approved. |
| 81 | Endoscopic SphinctrotomeTriple Lumen; 20mm cut wire; 5.5Fr tip size; off centric monofilament cut wire USFDA approved. |
| 82 | Endoscopic Needle knifeTriple Lumen; off centric monofilament cut wire with Exposure 1mm to 6mm, Tip Taper from 7Fr-5Fr USFDA approved. |
| 83 | Endoscopic Stone Retrieval Basket Pre cursor alloy material; Silver tip technology to avoid basket impaction; can be used for performing mechanical lithotripsy using a lithotriptor USFDA approved. |
| 84 | Endoscopic Stone Retrieval BalloonPriple lumen; Injection above/below; two distinct diameters 9-12mm, 12-15mm, 15-18mm; Square shoulder Balloon; Proximal Ro Markers USFDA approved. |
| 85 | Endoscopic Dilatation BalloonIndicated for esophageal, pyloric, colonic and biliary use (sphinctroplasty); PEBAX non compliant Material; 3 distinct diameters at 3 distinct pressures; rounded shoulders; clear material for visualization size12-15mm,15-18 mm, 18-20mm USFDA approved. |
| 86 | Endoscopic Biliary Dilatation BalloonHydrophilic dilatation baloon; 4Fr. Tip; langths 2 and 4 cm; 4, 6, 8, 10mm diameter sizes; 2 RO positioning markers USFDA approved. |
| 87 | Endoscopic Ultrasound NeedleCobalt Dhromium Material for 22 & 25 Ga and nitinal material for 19 Flesible; customized needle sheath; echogenic pattern till needle tip; sharp tip grind USFDA approved. |
| 88 | Guide wire0.035 tip (J-trip & straight trip) wire with 260 cm, 420 cm and 450cm working length with tip of 0.025 exchange guidewire hydrophilic tip ; kink resistant Nitinol standard and stiff shaft;; 10 cm hydrophillic tip USFDA approved. |
| 89 | Endoscopic Biopsy forceys USFDA approved. |
| 90 | Mechanical lithotryptor USFDA approved. |
| 91 | Multiband LigatorNon Latex Material, Clear Ligating Barrel With Rear Mounted Bands; Single Strand Deployment; Square Band Design For High Retention USFDA approved. |
| 92 | Hemoclip ApplicatorUSFDA approved. |
| 93 | Loop Grasper USFDA approved.. |
| 94 | Hemo Spray USFDA approved. |
| 95 | Co2 insufflater USFDA approved. |
| 96 | Water Jet irrigalien set USFDA approved. |
| 97 | Dormia basket USFDA approved.. |
| 98 | Tapezoid stone crushing basketUSFDA approved. |
| 99 | OASIS system for endoscopic billiary stent insetion USFDA approved. Total in Figures 0.0 0.0 98.0 0.0 0.0 0.0 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select % 0.0 0.0 Zero Only Quoted Rate in Words Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender