Tender For Repair Maintenance Of Summer Appliances Under Ge Dronachal
Tender Overview
Project Description
Tender For Repair Maintenance Of Summer Appliances Under Ge Dronachal=== 1 M & L For Sub Main Wiring Along With Earth Wire Drown Through Pvc Case & Caping For Split Type A/Cs With Frlsh Pvc Insulated, Unsheathed Multi Stranded Copper Single Core Cable Of Size 2 X 2.5 Sqmm And 1 X 2.5 Sqmm For Earth Wire Including Taking Down Old Wiring All As Directed. 2 M & L For Sub Main Wiring Along With Earth Wire Drown Through Pvc Case & Caping For Split Type A/Cs With Frls Pvc Insulated, Unsheathed Multi Stranded Copper Single Core Cable Of Size 2 X 4.0 Sqmm And 1 X 4.0 Sqmm For Earth Wire Including Taking Down Old Wiring All As Directed. 3 Supply & Fixing In Repairs Single Pole And Neutral Enclosure With A Two Pin And Socket Complete With One Single Pole Mcb 240 Volts, 20 Amps 4 M & L For Servicing Of Window Type Ac Of Capacity 1.5/2 Tr Of Any Make Including Cleaning Of Filter On Front Side By Removing Dust, Cleaning The Condenser Including Fins, Blower Fan Motor And Checking And Testing Of All Parts For Its Serviceability, Oiling/Greasing To Condenser Cum Blower Fan Motors, Replacing Worn Out Rubber, Bushes/Rubber Packing, Rectification Of Unusual Noise, Checking Of Refrigerant Standing Pressure, Replacement Of Minor Parts Such As Nut/Bolt Washers Etc And Reassembling Of Complete Ac Including Testing For Smooth Functioning Complete All As Directed By Engineer-In-Charge. 5 S&F In Repairs Aluminium Fan Blade Suitable For Condenser Of Window Type Ac Of Any Capacity. 6 S&F In Repairs Pvc Fan Blower Of Cooling Side Of Window Type Ac Of Any Capacity. 7 S & F In Repairs Wiring Kit Of Window Type Ac Complete With Lugs, Thimble And Selector Switch, Complete All As Directed. 8 S&F For Motor For Window Type Ac Of 1.5/2 Tr Capacity, Complete All As Directed By Engineer-In-Charge. 9 M & L For Servicing Of Split Type Ac Of Capacity 1.5/2 Tr Of Any By Opening The Condenser Unit Fixed On Roof Top And Cooling Unit Fixed Inside The Building, And Cleaning The Complete Condenser Unit And Cooling Unit Including Fins, Blower Fan Motor And Checking And Testing Of All Parts For Its Serviceability, Oiling/Greasing To Condenser Cum Blower Fan Motors, Remore Replacing Worn Out Rubber, Bushes/Rubber Packing, Rectification Of Unusal Noise, Checking Of Refrigerant Standing Pressure, Replacement Of Minor Parts Such As Nut/Bolt Washers Etc And Reassembling Of Complete Ac Including Testing For Smooth Functioning Complete All As Directed By Engineer-In-Charge.Note: Spare Parts Will Paid In Relevant Item Here In After:- 10 Supply Only Of Air Filter Of Size 10 Micron Split Type Ac 1.5/2 Tr 11 Supply Only Blade For Condensing Fan Motor Split Type Ac 12 Supply Only Running Capacitor 50 Mfd For 2 Tr Ac 13 Supply Only Running Capacitor 45 Mfd For 1.5 Tr Ac 14 Supply Only Condenser Coil Copper Of Ac Capacity 1.5 Tr 15 Supply Only Condenser Coil Copper Of Ac Capacity 2 Tr 16 Supply Only Suction Valve Brass Type 5/8\Of Ac Capacity 1.5 Tr 17 Supply Only Suction Valve Brass Type 5/8\Of Ac Capacity 2 Tr 18 Supply Only Coil Sensor And Room Sensor For Ac Capacity Of 1.5/2 Tr 19 Supply Only Swing Motor For Air Adjust Of Suitable Size Make:Oem 20 Supply Only Relay For Overload Of Suitable Size For Ac Capacity 1.5/2 Tr Make:Oem 21 Supply Fixing And Testing New Sealed Compressor Suitable For 1.5 Ton Split Type Air Conditioner Having Operating Voltage 200 To 240 Volts/50 Hz, Duly Filled Compressor Oil And M&L For Charging Of R-22/R-134A Gas In Adequate Quantity So That During Testing Effective Cooling Can Be Achieved Complete In All Respect All As Specified And Directed. 22 Supply Fixing And Testing New Sealed Compressor Suitable For 2.0 Ton Split Type Air Conditioner Having Operating Voltage 200 To 240 Volts/50 Hz, Duly Filled Compressor Oil And M&L For Charging Of R-22/R-134A Gas In Adequate Quantity So That During Testing Effective Cooling Can Be Achieved Complete In All Respect All As Specified And Directed. 23 Supply Fixing And Testing New Sealed Compressor Suitable For 1.5 Ton Window Type Air Conditioner Having Operating Voltage 200 To 240 Volts/50 Hz, Duly Filled Compressor Oil And M&L For Charging Of R-22/R-134A Gas In Adequate Quantity So That During Testing Effective Cooling Can Be Achieved Complete In All Respect All As Specified And Directed. 24 S & F Of Oem Compatible Indoor Unit Pcb Complete For Inverter Type Split Ac Up To 2.0 Tr Including Dismantling, Reconnecting, Testing And Commissioning Complete All As Directed By Engr In Charge. 25 S & F Of Oem Compatible Outdoor Unit Pcb Complete For Inverter Type Split Ac Up To 2.0 Tr Including Dismantling, Reconnecting, Testing And Commissioning Complete All As Directed By Engr In Charge. 26 M&L For Removing The Cooling Fan Motor Of Capacity 1/30 Or 1/35 Hp From Split Type Ac 1.5 Tr,And S&F The Same Complete All As Directed By Engr-In-Charge. 27 M&L For Removing The Cooling Fan Motor Of Capacity 1/30 Or 1/35 Hp From Split Type Ac 2 Tr,And S&F The Same Complete All As Directed By Engr-In-Charge. 28 S&F Of Blower Motor Of Capacity 1/30 Or 1/20 Hp Split Type Ac 1.5/2Tr. Complete All As Directed. 29 Supply And Filling Of Refrigerant Gas R-134A In Air Conditioner/ Refrigerator/ Deepfreezer/Water Cooler At Different Site As Required Including Brazing And Removal Of Leakage In Equipment 30 Supply And Filling Of Refrigerant Gas R-22 In Air Conditioner/ Refrigerator/ Deepfreezer/Water Cooler At Different Site As Required Including Brazing And Removal Of Leakage In Equipment 31 M & L For Wall Mounted Stablizer Of Capacity 4 Kva Including Fuze Assy, Terminal Panels, Indicators, Time Delay Relay And 3 Core Pvc Lead And Re-Assembling And Fixing In Position Complete All As Directed By Engr In Charge.
BOQ
| Sl. No. | Item Description |
| 1 | M & L for sub main wiring along with earth wire drown through PVC case & caping for split type A/Cs with FRLSH PVC insulated, unsheathed multi stranded copper single core cable of size 2 x 2.5 sqmm and 1 x 2.5 sqmm for earth wire including taking down old wiring all as directed. |
| 2 | M & L for sub main wiring along with earth wire drown through PVC case & caping for split type A/Cs with FRLS PVC insulated, unsheathed multi stranded copper single core cable of size 2 x 4.0 sqmm and 1 x 4.0 sqmm for earth wire including taking down old wiring all as directed. |
| 3 | Supply & fixing in repairs single pole and neutral enclosure with a two pin and socket complete with one single pole MCB 240 volts, 20 Amps |
| 4 | M & L for servicing of window type AC of capacity 1.5/2 TR of any make including cleaning of filter on front side by removing dust, cleaning the condenser including fins, blower fan motor and checking and testing of all parts for its serviceability, oiling/greasing to condenser cum blower fan motors, replacing worn out rubber, bushes/rubber packing, rectification of unusual noise, checking of refrigerant standing pressure, replacement of minor parts such as nut/bolt washers etc and reassembling of complete AC including testing for smooth functioning Complete all as directed by Engineer-in-Charge. |
| 5 | S&F in repairs aluminium fan blade suitable for condenser of window type AC of any capacity. |
| 6 | S&F in repairs PVC fan blower of cooling side of window type AC of any capacity. |
| 7 | S & F in repairs wiring kit of window type AC complete with lugs, thimble and selector switch, complete all as directed. |
| 8 | S&F for motor for window type AC of 1.5/2 TR capacity, Complete all as directed by Engineer-in-Charge. |
| 9 | M & L for servicing of split type AC of capacity 1.5/2 TR of any by opening the condenser unit fixed on roof top and cooling unit fixed inside the building, and cleaning the complete condenser unit and cooling unit including fins, blower fan motor and checking and testing of all parts for its serviceability, oiling/greasing to condenser cum blower fan motors, remore replacing worn out rubber, bushes/rubber packing, rectification of unusal noise, checking of refrigerant standing pressure, replacement of minor parts such as nut/bolt washers etc and reassembling of complete AC including testing for smooth functioning complete all as directed by Engineer-in-Charge.Note: Spare parts will paid in relevant item here in after:- |
| 10 | Supply only of air filter of size 10 micron Split type AC 1.5/2 TR |
| 11 | Supply only Blade for condensing fan motor Split type AC |
| 12 | Supply only running Capacitor 50 Mfd for 2 TR ac |
| 13 | Supply only running Capacitor 45 Mfd for 1.5 TR ac |
| 14 | Supply only condenser coil copper of ac capacity 1.5 TR |
| 15 | Supply only condenser coil copper of ac capacity 2 TR |
| 16 | Supply only suction valve brass type 5/8\\"of ac capacity 1.5 TR |
| 17 | Supply only suction valve brass type 5/8\\"of ac capacity 2 TR |
| 18 | Supply only coil sensor and room sensor for ac capacity of 1.5/2 TR |
| 19 | Supply only swing motor for air adjust of suitable size Make:OEM |
| 20 | Supply only relay for overload of suitable size for ac capacity 1.5/2 TR Make:OEM |
| 21 | Supply fixing and testing new sealed compressor suitable for 1.5 Ton split type air conditioner having operating voltage 200 to 240 volts/50 HZ, duly filled compressor oil and M&L for charging of R-22/R-134A gas in adequate quantity so that during testing effective cooling can be achieved complete in all respect all as specified and directed. |
| 22 | Supply fixing and testing new sealed compressor suitable for 2.0 Ton split type air conditioner having operating voltage 200 to 240 volts/50 HZ, duly filled compressor oil and M&L for charging of R-22/R-134A gas in adequate quantity so that during testing effective cooling can be achieved complete in all respect all as specified and directed. |
| 23 | Supply fixing and testing new sealed compressor suitable for 1.5 Ton window type air conditioner having operating voltage 200 to 240 volts/50 HZ, duly filled compressor oil and M&L for charging of R-22/R-134A gas in adequate quantity so that during testing effective cooling can be achieved complete in all respect all as specified and directed. |
| 24 | S & F of OEM compatible Indoor unit PCB complete for inverter type split AC up to 2.0 TR including dismantling, reconnecting, testing and commissioning complete all as directed by Engr in Charge. |
| 25 | S & F of OEM compatible Outdoor unit PCB complete for inverter type split AC up to 2.0 TR including dismantling, reconnecting, testing and commissioning complete all as directed by Engr in Charge. |
| 26 | M&L for removing the cooling fan motor of capacity 1/30 or 1/35 HP from split type AC 1.5 TR,and S&F the same complete all as directed by Engr-in-Charge. |
| 27 | M&L for removing the cooling fan motor of capacity 1/30 or 1/35 HP from split type AC 2 TR,and S&F the same complete all as directed by Engr-in-Charge. |
| 28 | S&F of blower motor of capacity 1/30 or 1/20 HP split type AC 1.5/2TR. Complete all as directed. |
| 29 | Supply and filling of Refrigerant gas R-134A in Air conditioner/ refrigerator/ deepfreezer/water cooler at different site as required including brazing and removal of leakage in equipment |
| 30 | Supply and filling of Refrigerant gas R-22 in Air conditioner/ refrigerator/ deepfreezer/water cooler at different site as required including brazing and removal of leakage in equipment |
| 31 | M & L for wall mounted Stablizer of capacity 4 KVA including Fuze assy, terminal panels, indicators, time delay relay and 3 core PVC lead and re-assembling and fixing in position complete all as directed by Engr in Charge. |
| 32 | M & L for wall mounted Stablizer of capacity 5 KVA including Fuze assy, terminal panels, indicators, time delay relay and 3 core PVC lead and re-assembling and fixing in position complete all as directed by Engr in Charge. Please Enable Macros to View BoQ information |
| 33 | M & L for wall mounted Stablizer of capacity 5 KVA including Fuze assy, terminal panels, indicators, time delay relay and 3 core PVC lead and re-assembling and fixing in position complete all as directed by Engr in Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender