Tender For Special Repair To Building No P-253 (Pm Shed) In Depot Area Of 221 Company Army Corps (Sup) Type G At Bb Cantt, Srinagar.
Tender Value
43.68 Lakhs
Estimated cost
Bid Submission
07 Aug 2026
16 days left
EMD
87370
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
srinagar → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair To Building No P-253 (Pm Shed) In Depot Area Of 221 Company Army Corps (Sup) Type G At Bb Cantt, Srinagar.
BOQ
| Sl. No. | Item Description |
| 1 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including Plain or corrugated steel sheeting, any gauge, thickness, and fixing of wind ties all over the roof sheet including dismantling of Nainital or similar pattern roof coverings, complete all as specified and directed.Note:- wind ties to be paid separately. |
| 2 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including Plain or corrugated steel sheeting, any gauge, thickness, including dismantling of Nainital or similar pattern roof coverings, complete all as specified and directed. |
| 3 | Dismantling wooden boardings any description ,fixed in any description with nails and screws all as specified and directed. |
| 4 | S&F 40mm Second class soft wood planed on one side, with butt joints and fixed with nails and anti-wood rot paint with primer of approved colour, complete all as specified and directed. |
| 5 | S&F 12-15mm Clean sawn wooden boards butt joints with nails in any situation (except flooring and skirting) with anti-wood rot paint with primer, complete all as specified and directed. |
| 6 | Dismantling timber scantling 40 sq cm & over in section , any position in unframed work, complete all as specified and directed. |
| 7 | S&F 2nd class softwood wood clean sawn timber fixed in scantling, complete all as specified and directed |
| 8 | M&L for preparation of new painted wooden surfaces of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed. |
| 9 | M&L preparation of old wooden surfaces of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint, complete all as specified and directed. |
| 10 | S&F 3mm Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5sq. m in each pane includdinghHacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads, complete all as specified and directed. |
| 11 | Taking down cement plaster on brick or stone walls incl.raking out joints hacking for key scrubbing down with water etc., complete all as specified and directed. |
| 12 | M & L for 15mm thick rendering on fair faces of brick work, concrete and other surface in CM 1:4 to be finished even and smooth with out uing extra cement, complete all as specified and directed. |
| 13 | M & L for 15mm thick rendering on brick work, concrete and other surface in CM 1:6 to be finished even and smooth without using extra cement, complete all as specified and directed. |
| 14 | M&L for rendering 5mm thick in cement mortar (1:3) & finishing the surface even & smooth without using extra cement as in ceiling, soffits of slab, complete all as specified and directed. |
| 15 | M & L for raised pointing to random or polygonal rubble, uncrushed or brought upto course in lime mortar or Cement mortar CM 1:3, complete all as specified and directed. |
| 16 | M&L for plain cement concrete 1:2:4, type B2 using 40mm graded crushed stone aggregate as in surface channels and drains, complete all as specified and directed. |
| 17 | M&L for preparation of new plastered surfaces of walls and applying three or more coats of White wash, complete all as specified and directed. |
| 18 | M&L for preparation of new plastered surfaces of ceiling and applying three or more coats of White wash, complete all as specified and directed. |
| 19 | M&L for preparation of old plastered surfaces of walls and applying three or more coats of White wash, complete all as specified and directed. |
| 20 | Demolition of cement concrete (un reinforced) in ground floor and paving n.exe 15 cm thickness (below or above ground level), complete all as specified and directed. |
| 21 | M & L for plain cement concrete 1:2:4 Type B-2 (using 20mm graded crushed stone aggregate) 75mm thick, as on floor, foot path etc., complete all as specified and as directed. |
| 22 | M&L for prepolished chequered cement concrete tiles 30cm X30cmX25mm thich set, joined and pointed in neat cement slurry in floors with grey cement and with grey cement and pigment laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:4 , complete all as specified and directed |
| 23 | Dismantling Stone slabs and tiles laid bedded and pointed in any mortar of any description or thickness in floors, aprons etc., complete all as specified and directed. |
| 24 | M&L Machine cut Kota Stone Mirror polished slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab laid over and including 20mm thick screed bed or bedding layer in cement mortar 1:3, complete all as specified and directed. |
| 25 | M & L Machine cut Kota Stone Mirror polished 18-20 mm thick in riser of steps, dado and pillar laid over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab laid over and including 10mm thick screed bed or bedding layer in cement mortar 1:3, complete all as specified and directed. |
| 26 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed. |
| 27 | M & L for brick work with sub class 'B' bricks straight or curved on plan to any radius built in CM 1 : 6 in brick walls, complete all as specified and directed. |
| 28 | Taking down chowkats or frames exc 1.5 Sqm but n. exc 4.00 Sqm each( without taking off shutters from the frames), complete all as specified and directed. |
| 29 | Taking down chowkat or frames with shutter (without taking off shutters from the frames) not exc 1.5 sqm each including cutting holes for taking out hold fasts or dismantling brick work/stone work (holes cut and any other damage to jambs walls for taking out hold fast shall be finished identical to existing finish without any extra cost to the govt), complete all as specified and directed. |
| 30 | S & F 30 mm thick 2nd class soft wood (kail) glazed and skeleton shutters, open rebated and prepared to receive glass, gauze et (without sash bars), edges of framing plain,, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, size of members of shutters as specified in SSR Part-I section -8 , clause 8.24 (b), complete all as specified and as directed . |
| 31 | S&F 3mm Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane, complete all as specified and directed. |
| 32 | M & L for 2nd class soft wood, plain straight, solid chawkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints, supplied and fixed. |
| 33 | S & F 2nd class hard wood 35mm thick plain framed panlled shutters (any numbers of panels) of 2nd class hard wood with panels of timber flat on both sides or of veenerred particles boards medium density, wood particle board with commercial face veereers, complete all as specified and directed. |
| 34 | M&L for Cutting holes in brick walls / stone wall built in cement mortar for inserting holdfasts depth of embeded portion of hold fast exc half brick but n exc one brick thick.and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required, complete all as specified and directed. |
| 35 | M&L for 25 x 3 mm thick mild steel flat iron for hold fast, complete all as specified and directed. |
| 36 | S & F aluminium alloy anodised sliding door bolt of size 300 mm with hasp, staple and fixing clips of sheet, cast or extruded sections and fixing, complete all as specified and directed. |
| 37 | S & F aluminium anodised barrel tower bolts of size 150 mm extruded section and fixed, complete all as specified and directed. |
| 38 | S & F 100mm long butt hings cold rolled mild steel & fixed to chowkats, complete all as specified and directed. |
| 39 | S&F framed work such as grills, gratings,, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed. |
| 40 | S&F rolled mild steel Gde-410W(Gde E-250) quality B in stairs (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, etc., complete all as specified and directed. |
| 41 | S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concreteand screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat ironfillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165, complete all as specified and directed. |
| 42 | M&L for preparation of new steel surfaces of any description,n exc 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 43 | M&L for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 44 | Dismantling structural steel work including doors, gates but excluding framed truss etc., complete all as specified and directed. |
| 45 | Excavating in post holes each n.exc 0.5 cum getting out and removing surplus soil to a distance n.exc 50 m and making good surface, complete all as specified and directed. |
| 46 | M & L for plain cement concrete 1:2:4 type B-2 (using 40 mm graded crushed stone aggregate) as in foundation of post/strut, filling and mass concrete etc., complete all as specified and directed |
| 47 | M & L for plain cement concrete (1:2:4) type B0 (using12.5mm graded crushed stone aggregate) 25mm thick, as in sub-base and finished surface even and smooth without using extra cement, complete all as specified and directed. |
| 48 | M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application, complete all as specified and directed. |
| 49 | PVC(SWR)single socketed in any length with rubber ring joint fixed with wall of 110mm as in rain water pipe incl Dimantling pipes of any desc.fixed to wall or laid under floor, complete all as specified and directed. |
| 50 | S&F 20mm thick boarding clean sawn as in eaves board fixed with nails incl Dismantling wooden boarding, any description , fixed in any position with nails complete all as specified and as directed. |
| 51 | M&L for rendering 10mm thick on fair faces of brickwork or concrete surfaces CM (1:4) including water proofing compound, complete all as specified and directed.Note:- WPC will be paid separately under respective item of this BOQ. |
| 52 | Supply Integral waterproofing compound , complete all as specified and directed. |
| 53 | M&L for taking down carefully existing old burnt out / unserviceable aluminium / copper point wiring system any type/ size and any description complete for light, fan,bell,socket, power points etc complete including removing the all type of fittings & fixture alongwith it connected fixing acessories such as all switches, sockets, ceiling roses, holder,regulators,bell etc complete and removing of all the old materials from the site for to taking as a schedule of credit complete all as specified and directed. |
| 54 | M&L for making single phasing point wiring system used as copper conductor wire for phase and neutral wiring system the wire made out of PVC insulated FRLS of 1100 volt grade with having multistranded copper conductor wire of size 1.5 Sq.mm (Nominal area) ISI marked drawn through wiring system concealed or on surface wall with the help of heavy duty ISI mark PVC conduit pipe ISI mark in any lengthy wiring system and along with its all connected fittings accessories including providing of pressed steel terminal sunken boxes or heavy duty PVC box and duly fixed it concealed in wall and alongwith providing of back and face top covered plate frame or electro plated plastic laminated sheet for housing / mounting of any type/size switches sockets, regulators etc and including using /drawing of one run of single wire 1.5 sqmm PVC insulated FRLS wire 1100 volt grade ISI marked with multistranded copper conductor wire used as a continuous earth wire for point wiring complete system and including making the good to all disturbed surfaces of wall/ceiling area of new wiring system and to match to it as per the existing surface of wall/ceiling etc complete all as specified and directed for the following:- |
| 55 | One light point / fan/bell/exhaust fan point wiring system controlled by one way switch, complete all as specified and directed. |
| 56 | One 5 Amp socket outlet point wiring system fixed on same board & controlled by one way switch, complete all as specified and directed. |
| 57 | One 5 Amp socket outlet point wiring system fixed on independent board & controlled by one way switch, complete all as specified and directed. |
| 58 | Description all as per serial item No 54 here-in-before, but using PVC insulated FRLS wire 1100 volt grade with multistranded copper conductor wire of size 2.5 Sq. mm (Nominal area) ISI Marked for power socket point on indenpent board point wiring system and also providing of 2.5 sqmm PVC insulated FRLS wire 1100 volt grade ISI Marked with multistranded copper conductor wire used as a continuous earth wire for power point wiring system, complete all as specified and directed. |
| 59 | Supply, laying and testing of LT cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volt grade cross sectional area of size 35 sqmm 3.5 core including laid in trenches or fixing on poles or passing through pipes complete including taking out of old unserviceable cable any type any size complete all as specified and directed. |
| 60 | Supply, laying and testing of LT cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volt grade cross sectional area of size 10 sqmm 4 core including laid in trenches or fixing on poles or passing through pipes complete including taking out of old unserviceable cable any type any size complete all as specified and directed. |
| 61 | Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for laying of cables, pipes etc. and getting out all excavated material in any type of soil, complete all as specified and directed. |
| 62 | Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and as directed. |
| 63 | Removing of excavated surplus soil to a distance not exc 50 m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed. |
| 64 | M&L of locally available river sand in trenches 15 cm below cable and 8cm above / around UG cable for cable protection, in duct under and above the cables including punning around cable complete all as specified and directed.Note: - Punned thickness shall only be measured and paid. |
| 65 | M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable, complete all as specified and directed. |
| 66 | Supply & fixing of switch piano, flush type single pole, one way 5/6 Amps 220 Volts AC, complete all as specified and directed. |
| 67 | Supply and fixing of socket outlet of 5/6 Amps 220 Volts AC, 2 in 1 3 pin, complete all as specified and directed. |
| 68 | Supply & fixing of switch piano, flush type single pole, one way 15/16 Amps 220 Volts AC, complete all as specified and directed. |
| 69 | Supply and fixing of socket outlet 3 pin, 16 Amp, flush type, complete all as specified and directed. |
| 70 | Supply and fixing ceiling rose three terminals type made out of polycarbonate , isolated body, complete all as specified and directed. |
| 71 | Supply and fixing of LED tube light fitting of 1x 20W/22W 220V AC decorative box type with driver, holder including LED tube light with having energy efficient type use in both warm/white type colour complete including providing of suitable type flate fexible cable for electric connection from ceiling rose to fitting comlplete and including taking down of old fitting, complete all as specified and directed. |
| 72 | Supply and fixing of LED street light fitting of rated capacity 35Watt 230 volt AC with having LED driver,lamp bracket with impact and corrosion resistant with lense embeded including thermal management in multiple optices complete with IP 65/66 protectiuon suitable for out door type made out of high pressure die cast hosing with heat resistant glass complete including providing of suitable size of dia GI pipe light grade bracket and it to match/setting the new fitting fixture hole attechment system of suitable bracket length upto 1.2 mtr long and make to shape / bend of 120 degree angle including duly fixed alongwith existing pole /bldg wall/ roof with the help of 02 Nos of MS fixing clamp alongwith nut bolt and including providing of suitable type of flate fexible two/three core cable and makong electric connection and including taking down of old fitting, complete all as specified and directed. |
| 73 | Supply and fixing of sheet metal enclosure box duly powder coated & framing work with locking system and having double door fixing arrengment system suitable of size/type for vertical type distribution board vertical loadline type of rating TPN 4 way type 415 volt 3 phase AC supply holding system with IP protection rating with ISI marked and having fitted neutral and earth link bus bar and mounting base chanels and blanking plates suitable for holding of main MCCB as incommer and out going MCB complete system alongwith providing and mounting in side of DB box of 01 No of MCCB TPN 125 Amps with breaking rupting capacity 16 KA and having adjustable setting type and also providing of 8 Nos of MCB SP 63 Amps 10KA 'C' curve type and 1 No isolator 3 phase 63 Amps of the same manufacture make as per of distribution board make complete set and including dully fixed surface on wall or concealed in wall and making all necessary electrical and also refixing the electric meter and its wiring connection including taking down of existing meter and DBs complete all as specified and directed. |
| 74 | S & F sheet metal enclosure box duly powder coated & framing work with locking system and having double door fixing arrangment system suitable of rating of size/type of distribution board SPN 8 way type 220 volt AC supply system with IP-43 protection system and having mounting chanel with having suitable rating of copper bus bar and suitable size of common neutral and earth link and also making all necessary electrical connection and duly fixed surface on wall or conceled in wall with the help of cutting chases to wall for fixing of DB and making good the disturbed wall surface, complete all as specified and directed. |
| 75 | S & F sheet metal enclosure box duly powder coated & framing work with locking system and having double door fixing arrangment system suitable of rating of size/type of distribution board SPN 4 way type 220 volt AC supply system with IP-43 protection system and having mounting chanel with having suitable rating of copper bus bar and suitable size of common neutral and earth link and also making all necessary electrical connection and duly fixed surface on wall or conceled in wall with the help of cutting chases to wall for fixing of DB and making good the disturbed wall surface complete all as specified and as directed. |
| 76 | S&F in replacment of Isolator TP 63 Amps, 16 KA, 3 pole 415V 50Hz, complete all as specified and directed. |
| 77 | S&F MCB SPN 40 to 63 Amp, 240 Volts, with breaking capacity 10 kA rupturing capacity, 'C' series 50 HZ AC supply and also making suitable size/type of electric wiring connection, complete all as specified and directed. |
| 78 | S&F MCB SP 06 to 32 Amp, 240 Volt, 10 kA rupturing capacity 'C' series 50 HZ AC supply and also making suitable size/type of electric wiring connection, complete all as specified and directed. |
| 79 | Supply and fixing of Sub main wiring system with two runs PVC insulated FRLS wire,1100 volt grade with multistranded copper conductor wire of size 3 Run of 6 Sqmm and 1 Run of 6 Sqmm (Nominal area) (ISI Marked) any type any length drawn through in heavy duty ISI mark PVC Casing capping / PVC conduit of suitable size along with its all fittings and connected accessories and duly fixed concealed on wall or surface on wall including taking down old unservicable sub main wiring system complete and making good all disturbed surfaces match to the existing surface complete all as specified and directed . Note: 4 runs of 6 sqmm cable and one run of conduit/ casing capping shall be measured and paid as one unit. |
| 80 | M&L for earthing work complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level and connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers of galvanised steel and to be protected by GI pipe 15 mm bore light grade & connected to earth test point/main switch board or main control board and also providing charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil all as shown in Electrical Plate No 3 of SSR part -I. and also making arrangment of 20 mm dia bore galvanised iron pipe (medium grade) for water and making funnel, wire mesh,and also including provision of concrete pit cover framing work in PCC (1:2:4) type B-1 using 20mm graded of stone aggregate with XPM (weight not less than 4 Kg/Sqm) and outer frame work of angle iron 25x25x6mm with top concrete pit cover and handle for lifting of cover complete work all as specified and directed. |
| 81 | Supply and fixing of rigid non metalic PVC conduit of size 20/25 mm bore heavy duty with all fitting laid in trenches/wall including providing clamping arrengment for holding of pipe on wall in proper size of clamps,nut bolt, and washer etc complete all as specified and directed. |
| 82 | Notes :-An amount of Rs 2,39,592.00 on account of Credit Schedule for Schedule 'A' Part-II shall be deducted from total quoted amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysAug 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender