Defence Statutory Bodies & Commissions/Committees Closing in 12 days TDR #56564505

Tender For Provision Of Diesel Generator Of Capacity 125 Kva With Reqd Electricity Fitting Ancillaries And Connection And Constr Of Combined Toilet And Bathroom Block With Soakage Pit At Tangtse Age Br-Iii Under Ge 860 Ews

Issued by Statutory Bodies & Commissions/Committees · leh, Ladakh
Tender Value
47.80 Lakhs
Estimated cost
Bid Submission
07 Aug 2026
12 days left
EMD
96000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
leh → Ladakh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Provision Of Diesel Generator Of Capacity 125 Kva With Reqd Electricity Fitting Ancillaries And Connection And Constr Of Combined Toilet And Bathroom Block With Soakage Pit At Tangtse Age Br-Iii Under Ge 860 Ews

BOQ

Name of Work:- PROVN OF DIESEL GENR OF CAPACITY 125 KVA WITH REQD ELECTRICITY FITTING ANCILLARIES AND CONNECTION AND CONSTR OF COMBINED TOILET AND BATHROOM BLOCK WITH SOAKAGE PIT AT TANGTSE AGE BR-III UNDER GE 860 EWS
Sl. No. Item Description
1Surface dressing n. exc 15 cm deep in hard/dense soil complete all as specified and directed.
2Excavating in trenches n. exc 1.5 m wide and n. exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out in hard/dense soil complete all as specified and directed.
3M&L for PCC 1:4:8 type D-2 ( Nominalmix) using 40 mm graded stone aggregate as in foundation filling and similar work complete all as specified and directed.
4Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete etc complete all as specified and directed.
5Formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished square, rectangular or polygonal surfaces of concrete for rough finished surfaces etc complete all as specified and directed.
6Formwork to sides and soffits of floor or roof beams, beam haunch ings, girders, bressummers, lintels, cantilevers, helves including sup- ports, overhangs, etc. also splays between floors and beams, etc. vertical or batter for rough finished flat surfaces of concrete complete all as specified and directed.
7Formwork to soffits of suspedded slabs such as roof slabs, floor slabs landings and similar work ,vertical or to batter for rough finished flat surfaces of concrete complete all as specified and directed.
8M&L for rough finished formwork to edges of concrete flats, treads, break in floors, window cills, concrete railings, floor and roof n.exc 20 cm wide and side of RCC/ PCC band in walls, horizantal or sloping or similar work exc 10 cm but n. exc 20 cm wide rough finished surface of concrete complete all as specified and directed.
9M&L TMT bars 10mm dia and over in reinforcement cut to length bent to shape required incl hooking ends and binding with MS wire (annealed) not less than 0.9mm dia complete all as specified and directed.
10TMT bars for reinforcement 5mm to 10mm dia as in stirrups/spacers/binders etc. cut to length bent to shape required including bending cranking and hooking ends and binding with including MS wire not less than 0.9mm(annealed) dia complete all as specified and directed.
11M & L RCC M-25 (Design Mix) (20mm graded aggregate) in foundations, including rafts,footings, foundation beams, plinth beams, bases of columns and similar work complete all as specified and as directed.
12M & L RCC M-25 (Design Mix) (20mm graded aggregate) in columns, pillars, piers, post and struts etc complete all as specified and as directed.
13M & L RCC M-25 (Design Mix) (20mm graded aggregate) in Beams, cantilevers,and lintels and chajja etc complete all as specified and as directed.
14M & L RCC M-25 (Design Mix) (20mm graded aggregate) in Slab supported in walls beams and columns in roof ,Landing, balconies, deck slabs and in shelves and similar work complete all as specified and as directed.
15Returning filling in incl spreading leveling, watering, and well, ramming in layer n.exc 25 cm in layers in hard/dense soil complete all as specified and directed.
16Removing excavated material (soil) to a distance n. exc 50 m and depositing where directed at a level n. exc 1.50 m above the starting point complete all as specified and directed.
17Providing precast cement concrete solid building blocks or slabs 10cm thick (with plain or interlocking joints as directed) setting in mortar, complete, in walls all as specified and directed.
18M&L for Pre-cast cement concrete block masonry Type C-1 (1:3:6) 20 mm graded aggregate with solid blocks, exc. 10 cm in width and setting in mortar 1:6 complete all as specified and directed.
19M&L for rendering 5mm thick in cement mortar 1:3 on ceiling surface, finished even and smooth without using extra cement complete.
20M&L for Rendering 10mm thick in cement mortar 1:6 on PCC block walling or concrete surfaces, finished even and smooth without using extra cement complete.
21Rendering 15mm thick in CM (1:4) using water proofing compound as per manufacturer's instruction in two layers, finished even and smooth surface without using extra cement - External Plaster (WPC measured and paid separately) complete all as specified and directed.
22M&L for Glazed ceramic coloured tiles in vertical surface 450x350x7mm thick , set and jointed in neat cement slurry and pointed in coloured cement to match tiles over 10mm thick backing coat in cm 1:4 complete all as specified and directed.
23M&L for broken stone or boulder hard core of gauge not exc 63 mm deposited spread and levelled in layers not exc.150mm thick watered and rammed to a true surfaces complete all as specified and directed.
24M&L for Cement Concrete type C-2, 1:3:6 (40 mm graded aggregate) - 100mm thick as Sub base complete all as specified and directed.
25M&L for 15 mm Screed bed or bedding layer of cement mortar 1:6 laying floor finishes
26M&L for coloured Non Skid Ceramic joint free tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm , in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed 15mm thick in CM 1:6 complete all as specified and directed.
27M&L for preparation of new plaster surfaces, and applying two coat of white wash on walls complete all as specified and directed.
28M&L for preparation of new plaster surfaces, and applying two coat of white wash on ceiling complete all as specified and directed.
29M&L for preparation of new plaster surfaces and applying two coat of cement base paint over a coat of primer complete all as specified and directed.(External Surface)
30Supply only Integral water proofing compound for external plaster complete all as specified and directed.
31S&F of 2nd class hard wood, Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
32S&F plain 2nd class hardwood 35mm thick framed, panelled shutter (one panel) without interlocking rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed.
33S&F 100mm Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed
34S&F 200mm Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed
35S&F 150mm Aluminium handles, cast type, anodised complete all as specified and directed
36S&F 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed
37S&F 250mm long, Aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
38M&L for preparation of new or previously untreated wooden surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed.
39S&F of 4mm thick sheet glass, ordinary quality and glazing with oil putty and glazing pins in square n exc 0.5 sq. m in each pane complete all as specified and directed.
40S&F 3 layer PP-R Polypropyene ransom copolymer outer dia of pipe 16 mm concealed pipes SDR 7.4 (PN-16) UV stabilzed and anti microbial fusionwelded having thermal stavility for hot & cold water supply including all PPR plain & brass threaded polypropylene random fittings fixed complete to wall s, ceilins or in floors etc.
41S&F 3 layer PP-R Polypropyene ransom copolymer outer dia of pipe 20 mm concealed pipes SDR 7.4 (PN-16) UV stabilzed and anti microbial fusionwelded having thermal stavility for hot & cold water supply including all PPR plain & brass threaded polypropylene random fittings fixed complete to wall s, ceilins or in floors etc.
42S&F gun-metal stop cock 20 mm bore, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
43S&F 15 mm bore stop valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
44S&F 15 mm bore bib tap brass chromium plated fancy type with crutch or butterfly handle screwed down, screwed for iron pipe complete all as specified and directed.
45S&F 15mm bore pillar taps CP brass chromium plated fancy type screwed down high pressure with chromium plated screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
46S&F vitreous china wash hand basin including brackets, white size 550 x 400 mm incl cutting for and pinning in ends of brackets including waste fittings, brass chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other and fixed complete all as specified and directed.
47S&F in repairs vitreous china water closet (squatt pan) orrisa pattern 580x440 mm size pan white with front or back inlet with integral 'foot rests including provn of lime concrete bedding including connections to 'flushing cistern/pipe including 100mm PVC 'P' trap complete all as specified and directed.
48S&F 10 Litre capacity PVC low level flushing cistern with ball valve and handle/push button 32mm dia PVC flush pipe including taking down unserviceable cistern complete all as specified and directed.
49S&F for Vitreous China bowl type urinals, size of 465x355x265mm white(minimum) with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (excluding of fixing supply pipe, flushing cistern, flush pipe, trap and waste pipe) complete all as specified and directed.
50S&F urinal spreader of PTMT of any colour for fixing with 15mmdia pipe complete all as specified and directed.
51S&F 32mm Dia PVC waste pipe with fly nut, copling for sinks/urinals or wash basins etc. complete all as specified and directed.
52S&F 15 mm bore LDPE pipe 45cm long with brass nuts and washers on both ends complete all as specified and directed.
53S&F 600mmX450mm bevelled edge Mirror 5 mm thick of selected quality glass, mounted on 6mm thick AC building board or comercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washer complete all as specified and directed.
54S&F 20mm dia brass chromium plated tubular towel rails, D type, 60cm long between flanges, complete all as specified and directed.
55S&F for 1000 ltrs capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed by Engr-in-Charge.
56S&F sheet glass shelf assembly consisting of 5.50mm thick sheet glass self 12cm wide with chromium plated brackets guard and railing 60 cm long complete all as specified and as directed.
57S&F 75mm dia bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to floors complete all as specified and as directed.
58S&F in repairs grating doom 75mm dia of PTMT (Minimum weight 25gms) complete all as specified and as directed.
59M& L for cement concrete 75mm thick type D - 2 using 40mm graded stone aggregate as in sub base to receive floor finish etc complete all as specified and as directed.
60Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed.
61Construcion of Soakage well exe, in hard/dense soil, foundation in PCC 1:3:6, well of honey combed and solid in M-25 concrete, including intercepting chamber, screen chamber stone masonry in CM, RCC cover slab in M-30/RR Masonry/Filling with brick bats complete of size 3.00mtr dia and 3.0mtr deep n etc.,complete all as specified and directed.
62Construcion of Septic tank exe, in hard/dense soil, foundation in PCC 1:3:6, well of honey combed and solid in M-25 concrete, including intercepting chamber, screen chamber PCC Block masonry in CM, RCC cover slab in M-30/RR Masonry/Filling with brick bats complete of size 4.0 mtr x 2.0 mtr x 2.0 mtr deep n etc.,complete all as specified and directed.
63M&L for Reinforced concrete pipes, class NP2 of dia 200 mm , laid and jointed complete with collars in trenches complete all as specified.
64M&L Concrete bed in cement concrete 1:4:8 type D-2(using 40mm graded crushed stone aggregate) to drain pipes incl packing under and haunching against the sides of pipes after they are laid and tested in complete all as specified and as directed.
65M&L for Providing precast reinforced cement concrete type B1 1:2:4 (using 20mm graded crushed stone aggregate) as in landings, cover slabs (for manholes etc.) mangers, shelves and similar articles set in CM 1:6 complete all as specified and as directed.
66M&L for Plain cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in coping, benching bed plates and the line including necessary form work and finishing all exposed surface of concrete as per clause 4.11.16.2(a) of SSR Part-I(1991) complete all as specified and as directed.
67Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in soft / loose soil.
68Excavating in post holes soft and dense soil each n.exc 0.5 cum getting out returning filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25 cm watering and removing surplus soil to a distance n.exc 50 m and making good surface complete.
69M & L for cement conc 1:3:6 type C-2 (40 mm graded aggregate) as in post/strut fdn concrete and wall fdn complete.
70M&L for Hard core of broken stone of gauge exc 63mm but n.exc 100mm, deposited, spread and levelled in layers n. exc 15cm thick, watered and rammed to a true surface all as specified and directed.
71M & L for 50mm thick PCC 1:2:4 type B-1 using 20mm graded aggregate as in subbase over rammed earth all as specified.
72M&L Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240
73S&F rolled MS section as in Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc fixed with angle cleats or other connecting plates confirming to Fe 410-W quality B complete all as specified and as directed.
74S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment confirming to Fe-290 Gde E-165
75Mild steel screw bolts ( machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers hexagonal or squareand one nut, exc 22.5 CM and n.exc 30 CM long Dia of neck 16 to 20mm
76M&L applying two coats of synthetic enamel paints on new steel surfaces over a coat of red oxide primer including surface preparation
77M&L for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping crews as specified
78M&L for Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering ridges /cladding to wall, fixed with self tapping crews as specified
79Material and labour for point wiring with 1.5 Sqmm copper conductor (Multi-standard) PVC insulated and unsheathed electric cable 1100 volts in and including PVC casing and capping of 25 mm and above (as per conductor run )with all fittings/ accessories and including PVC insulated and unsheathed electric cable 1100 volts1.5 Sqmm ( multi-stranded) copper conductor single core( Green colour) cable as continuous earth wire connected to common earth dolly including 50 mm deep box made of 2nd class hard board of required size and shape etc covered with 3 mm thick plastic laminated sheet ( Make Hylum) for one light point,bell,exhaust point, bulk head, independent controlled by one, one way switch complete all as specified and as directed by the Engineer-in-Charge.
80Description all as per item No.79.00 here-in-before but for one 3 pin socket outlet 5/6 Amps on independent board with 1.5 Sq.mm. FRLS PVC wire and one run of 1.00 Sq.mm. copper cable for earth continuity.
81Supply and fix of Switch piano flush type single pole, one way 5 Amp , all as specified.
82Supply and fixing switch socket combination 2 in 1, 5 Amp, flush type complete all as specified and as directed by Engr-in-charge.
83Supply and fixing ceiling rose, surface bakelite, 65 x 50 mm, three terminals complete all specified and as directed by the Engineer-in-Charge.
84Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder includingLED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all specified and as directed by the Engineer-in-Charge.
85Supply and fixing sheet Metal enclosure single shutter type for DB’s 240 Volts Single Pole and Neutral 4 way with 200 Amps rated bus bar complete including wooden board of required size duly painted with matching colour paint all as specified and as directed by the Engr-in-charge.
86Supply and fixing MCB single pole and neutral 32 to 40 Amps , 240 volt, 10 KA, complete all as specified and as directed by the Engineer-in-Charge.
87Supply and fixing MCB single pole 5 to 30 Amps, 240 volts, 10 KA complete all as specified and as directed by the Engineer-in-Charge. .
88Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm.
89Supply and fixing new energy saving LED Bulk head fitting 10 watt made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP 66 protection and impact resistance of IK07 as reqd to be mounting bracket in wall/floor to suit the opening of the fitting with FI clamp, nut, bolt and washers of suitable size including making connection complete all as specified and as directed by Eng-In-Charge
90Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanized iron earth wire 4.0 mm dia by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 3 of SSR 1991 Part-I and connecting to CBDB’s as specified or indicated including testing on completion .
91Supply and laying XLPE insulated, armoured, heavy duty electric cable, with stranded aluminum conductor 1100 V grade nominal cross sectional area 10 Sqmm, 2 core laid in trenches, ducts, drawn through pipes across the road/path/along poles/wall/floors/equipment etc including jointing and testing complete all as specified and directed by the Engr-in-Charge
92Material and labour for un-reinforced pre-cast concrete cable covers, class LV type-1, flat size 250mm x 150mm x 40mm thick complete all as specified and directed by Engr-in-Charge.
93M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 15cm after laying, streching & testing of cable in trenches complete all as specified and directed by Engr-in-Charge. Note :- Only punned thickness i.e 18cm shall be measured and paid.
94Supply, installation, testing and commissioning of Diesel engine driven Generating set, self excited, self regulated, brushless AC generator of Capacity 125 KVA / 320 KW, 415 Volts, 3 Phase, 0.8 power factor, 50 Hz, 1500 RPM at NTP with silencer pipe , acoustic enclosure with sound proof canopy and sound level should be 75 DB (A) at a distance 1 Mtrs as per ISO 8528 Part-1, protected with asbetos rope independently supported from engine to outside power house up to 1 mtr, AVM pads, PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) foundation for DG set as per manufacturer design, battery start with suitable cable for connection up to panel board . The DG Set will be capable of operating in Temp range of (-) 35 degree centigrade to (+) 35 degree centigrade at an altitude of 4250 mts above MSL complete with and including the following:- ALTERNATOR : Alternator rating 125 KVA(320 KW), 3 phase, 50 cycles, 415 volt, 4 wire supply, 0.8 power factor, running @ 1500 RPM self excited, self regulated, mounted on a strong fabricated steel frame, suitable for mounting on a permanent foundation 4 wire, 415 Volts,50 cycles, 1500 RPM, self excited, self regulated, mounted on a strong fabricated steel frame suitable for mounting on a permanent foundation to be coupled with above engine. The alternator shall be conforming to BS 2613/5000 and shall be in position to generate supply with frequency regulation within ± 3% tolerance. The alternator will be suitable for tropical climate.
95DIESEL ENGINE : Vertical diesel engine of suitable capacity, naturally Coolent Cooled/water cooled, closed circuit as per BS-649 or IS-1002 direct injuction type turbo charged Make : Cummins India Ltd/Kirloskar/Greaves/Ashok Layland/Ruston/ Mahindra Powerol/ Caterpillar Electric starting system having rated speed 1500 RPM. The DG set Shall be capable for running 24 hrs continuously with 10% over loading for one hour in every 12 hours as per BS-5514/BS-649. Engine shall be multi cylinder, multi stroke, direct injection, cold starting and equipped with all standard fitting as per manufacture's recommendations and mounted on common base frame with following fittings.(a) Fly wheel with housing (i) Common base frame of sturdy design suitable for anti vibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturer's instructions.(b) Cooling system Naturally water cooled type (Use DAFC 50%)(c) FUEL SYSTEM : Fuel injection system with fuel injector, fuel injector pump/governer electronic type fuel filter and fuel hose. (d) LUB OIL SYSTEM : Lub oil pump,Electric motor driven and lub oil filter. (e) AIR INTAKE SYSTEM : Air intake manifold and air cleaner dry type. (f) GOVERNER : Electronic Governer. (g) ELECTRIC STARTING SYSTEM : Electric Self starter , 24 volts DC battery (12 volt, 180 AH battery 2 No, Maint free charging alternator with regulator battery as per manufacturer's design, copper leads with lugs of adequate size complete with initial charging fly wheel ring and start and stop push button.
96(h) Safe Controls for Engine low lub oil pressure ,high water temp, over speeding of engine and battery charging voltage display. (j) GENERATOR MONITORING PANEL : Comprising of following :-(k) Microprocessor based genset controller for metering, monitoring, governing and protection. (i) Engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) (ii) Alternator protection parameters like under voltage, over current, under frequency, over frequency (alarm & shut down) (l) ACCESSORIES: AVM Pads built or separately mounted to manufacturer base frames. (m) COUPLING ARRANGEMENTS: Fixed coupling, flywheel to suit fixed coupling and fly wheel housing. (n) EXHAUST SYSTEM : Silencer complete with exhaust pipe of suitable size upto and out side the building all covered with asbetos rope of suitable size all as directed.(O) FUEL TANK: Daily service fuel tank of capacity suitable for 8 hours continuous operation made out of 3 mm thick (heat retardant) sheet top and bottom with caliberated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity and connected pipe line should be installed with in built tank inside the acoustic enclosures inclusive of the cost of DG set and is as per manufacturer design.
97(P) ACOUSTIC ENCLOSURE : Enclosure is free standing floor mounted factory built and modular in construction to facilitate easy assembly at work site and will be drop over housing type. It will consist of acoustically treated panel housed in sheet steel will provide easy access for maintenance, repairs and operation. The enclosure is custom built to suit conditions, with the following features:- (i) Custom built product for various Equipments, which ensure the optimum performance. (ii) Rugged in construction maintenance free and modular designs which facilitate easy at site. (iii) 16 SWG (1.6 mm) thick CRCA sheets to be used for enclosure panel to ensure longer life against weathering action. High quality acoustic insulation materials to be used for maximum sound absorption. Acoustic layers are supported by perforated sheets. (iv) Sheet metal components of the enclosure should undergo various stages of surface treatment prior to painting which leads to be better life of the enclosure against weathering action. (v) Special paint treatment with pure polyester powder / epoxy to be provided for better weather resistance. (vi) Well designed ventilation system to be provided to pump up the heat in the chamber efficiently.
98(vii) For effective acoustic / weather sealing a special type weather sealing gaskets, new frame rubber gaskets to used. (viii) Working space is to be provided around the equipment for easy maintenance / repairs. (ix) Necessary cut out provision for entry and exist of fuel lines cable to be incorporated in the enclosure as per the requirement. (x) A see through transparent window (glass or acrylic) in front of engine panel to provided for monitoring the operation. (xi) Ducting if required, bellows, mechanical hardware like locks, hinges fasteners etc to be provided. (xii) Deliverables. 75 dBA @ 1 mtr at full load under free field conditions. The temp inside the enclosure will be within as per manufacturer’s recommendations above ambient temp. (xiii) The enclosure should be provided with bulk head light fitting for inside illumination. (xiv) The battery should be placed inside the enclosure beside the DG Set on a suitable insulated platform. (xv) The DG Set should be provided with external Emergency stop push button. (xvi) The acoustic enclosure parts shall be of powder coated after pretreatment process. The powder coating shade should be as per manufacture's design. The base frame should be painted with epoxy based black shade. Make for ACCOUSTIC PANEL:-As per OEM design, Make of DG Set: - CUMMINS /KIRLOSKAR/Mahindra Please Enable Macros to View BoQ information
99(vii) For effective acoustic / weather sealing a special type weather sealing gaskets, new frame rubber gaskets to used. (viii) Working space is to be provided around the equipment for easy maintenance / repairs. (ix) Necessary cut out provision for entry and exist of fuel lines cable to be incorporated in the enclosure as per the requirement. (x) A see through transparent window (glass or acrylic) in front of engine panel to provided for monitoring the operation. (xi) Ducting if required, bellows, mechanical hardware like locks, hinges fasteners etc to be provided. (xii) Deliverables. 75 dBA @ 1 mtr at full load under free field conditions. The temp inside the enclosure will be within as per manufacturer’s recommendations above ambient temp. (xiii) The enclosure should be provided with bulk head light fitting for inside illumination. (xiv) The battery should be placed inside the enclosure beside the DG Set on a suitable insulated platform. (xv) The DG Set should be provided with external Emergency stop push button. (xvi) The acoustic enclosure parts shall be of powder coated after pretreatment process. The powder coating shade should be as per manufacture's design. The base frame should be painted with epoxy based black shade. Make for ACCOUSTIC PANEL:-As per OEM design, Make of DG Set: - CUMMINS /KIRLOSKAR/Mahindra Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56564505
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 47.80 Lakhs
LAST DATE 07-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Provision Of Diesel Generator Of Capacity 125 Kva With Reqd Electricity Fitting Ancillaries And Connection And Constr Of Combined Toilet And Bathroom Block With Soakage Pit At Tangtse Age Br-Iii Under Ge 860 Ews
Basic Detail
Tender No 8170/2026-27/E8
Bidding Type Tender
Location
City leh
State Ladakh
Key Dates
Publish Date 17 Jul 2026
Submission Date 07 Aug 2026
Open Date 10 Aug 2026
Finance
Tender Value 47.80 Lakhs
Tender Fee 500
EMD 96000
Exemption Available
Document List
Tender2.pdf
Tender3.pdf
Tendernotice_1.pdf
BOQ_872814.xls
c482eb91-3a7a-404d-8fbc-ebf522b14d59.html
Tender1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Aug 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
pdf

Tender2.pdf

pdf

Tender3.pdf

pdf

Tendernotice_1.pdf

xls

BOQ_872814.xls

html

c482eb91-3a7a-404d-8fbc-ebf522b14d59.html

pdf

Tender1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders