Tender For Addition Alteration To Building T-68 And 69 Hrdc At Btr, Acc&S Ahilyanagar Under Ge (N) Ahilyanagar.
Tender Value
42.68 Lakhs
Estimated cost
Bid Submission
07 Aug 2026
17 days left
EMD
86000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ahmednagar → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Addition Alteration To Building T-68 And 69 Hrdc At Btr, Acc&S Ahilyanagar Under Ge (N) Ahilyanagar.
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of cement concrete (un-reinforced) in ground floor & paving n.exc. 15cm thick below or above ground level. |
| 2 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified. |
| 3 | M&L for providing 75mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate as in sub base complete all as directed. |
| 4 | M&L for joint free / rectified anti skid ceramic coloured tiles 8-10 mm thick as approved by GE (square/rectangular) area of each tile 600x600mm, as in floor etc laid over and including screed bed 15 mm thick in cement and sand mortar (1:6 ) set and jointed with white or coloured cement to match the shade of tile etc complete all as specified and as directed |
| 5 | .-ditto- all as per ser item No 04 above but as in dado/ skirting on vertical surfaces over and including 10 mm thick backing coat in CM (1:4) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile etc complete all as specified and directed. |
| 6 | M&L for coloured glazed ceramic tiles digitally printed 300x450mm, 7-8 mm thick as approved by GE as in dado/skirting or on vertical surfaces, over and including 10 mm thick backing coat in CM (1:4) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile etc complete all as specified and directed. |
| 7 | M&L for joint free /rectified anti skid ceramic coloured tiles 7-8mm thick matching to dado tiles area of each tile 400x400mm, including backing coat 15 mm thick in cement mortar 1:6 set and jointed with white or coloured cement to match complete all as specified and as directed. |
| 8 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons laid, bedded and pointed in any mortar etc. |
| 9 | M&L for 15mm thick Granite (of any type) tiles machine cut, single piece jambs and double piece cills overall lenght of window riser of steps, skirting, dado and pillar laid over cement mortar backing coat jointed with grey cement slurry mixed with pigment to match the shade of the slab including pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing,moulding complete and including rendering/ backing coat coat of 15 mm thick in CM 1:3 etc complete all as specified and as directed. |
| 10 | M&L for 18-20mm thick machine cut kota stone slab in flooring,steps over 20 mm thick screed base in cement and sand (1:6) mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed by Engineer-in-Charge. |
| 11 | M&L for Kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar including 15 mm thick backing coat in cement and sand mortar (1:4) etc complete all as specified and directed by Engineer-in-Charge |
| 12 | M&L for 30-40mm thick rough dressed Shahabad stone as in floor/plinth etc over and incl 15mm thick screed bed in CM 1:6 complete all as specified and directed |
| 13 | Fixing only 30-40mm thick rough dressed Shahabad stone as in floor/ plinth etc over and incl 15mm thick screed bed in CM 1:6 including dismantling complete all as specified and directed |
| 14 | M&L for 60 mm thick, PCC pavers interlocking tiles of glossy finish, with grey cement and no pigment ,any shape & size conforming to IS 15658 of 2006. M-35 grade made up with 12.5mm graded mechanically crushed stone aggregates, factory made over and incl 30mm thick sand cushioning and joints filled with fine sand incl leveled with plate vibrator & sweeping etc complete all as specified and directed. |
| 15 | Demolition of brickwork or stone bouilder masonary built in cement mortar or lime mortar complete all as specified |
| 16 | M&L for brickwork with fly ash bricks straight or curved on plan exc 6m mean radius,built in CM 1: 6 complete all as specified |
| 17 | M&L for brickwork with fly ash bricks straight or curved on plan exc 6m mean radius, built in CM 1: 6 complete all as specified |
| 18 | Taking down cement mortar plaster on brick or stone walls, raking out joints, hacking for key complete all as directed |
| 19 | M&L for rendering, 15 mm thick on brick/Stone Masonry/ concrete surfaces in cement mortar 1:6 surfaces finished even and smooth without using extra cement including sagol finished complete all as specified. |
| 20 | M&L for rendering, 15 mm thick on stone/brick / concrete surfaces in cement mortar 1:4 finished even and fair without using extra cement complete all as specified and directed. |
| 21 | M & L for preparation of newly plastered surface of wall and apply two coats of OBD over a coat of primer any height including scaffholding etc complete all as directed. |
| 22 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new/old surfaces. |
| 23 | M & L for preparing old plastered surfaces of walls and apply two coat of OBD, finished with roller finish on plastered surfaces of wall any height including scaffholding etc complete all as specified and directed |
| 24 | M&L for 2 mm thick wall care putty etc complete all as specified and directed |
| 25 | S&F fix in repairs wash hand basin with pedestal vitreous China white , flat back or angle type of size 550 X 400 mm incl waste chain and plug and porcelain stopper, waste pipe, a pair of brackets, or erecting stand and PVC connection etc complete all as specified and directed by Engineer-in-Charge. |
| 26 | S&F in repairs vitreous China white squatting pan, Orissa pattern of size 580 X 440 mm width with integral foot rest set in cement concrete including flush pipe and connecting to trap / flushing cistern etc complete all as specified and directed by Engineer-in-Charge. |
| 27 | Supply only 10 ltr capacity PVC valve less, symphonic action type, flushing cistern, low level, all accessories etc complete all as specified and directed by Engineer-in-Charge. |
| 28 | Taking up or down 15 mm bore steel tubing and connections |
| 29 | Ditto all as per ser item No 28 above but 20 mm bore tubing. |
| 30 | Supplying and laying 16 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all fittings complete all as specified. |
| 31 | Ditto all as per ser item No 30 above but 20 mm bore tubing |
| 32 | S & F in repairs PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified. |
| 33 | S&F in repairs fancy type stop cock/ anglecock/ two way cock cast copper alloy, Chromium plated fancy type screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fix of size 15 mm bore etc complete all as specified and directed by Engineer-in-Charge |
| 34 | S&F in repairs bib tap 15 mm dia, fancy type CP cast copper alloy with crutch or butterfly handle screwed down for iron pipe or for brass ferrule etc complete all as specified and directed by Engineer-in-Charge. |
| 35 | Supply only 15 mm dia pillar tap, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe all as directed. |
| 36 | Supply only PVC flexible 32 mm Waste pipe for WHB, Sink etc complete all as specified. |
| 37 | S&F in repair PVC (SWR) 110mm bore (dia) soil, waste and vent Pipe, (ISI Marked), in any length with rubber ring Joints fixed to wall with necessary stay clamps/ laid in trenches/floor etc complete all as specifed and directed. |
| 38 | .-Ditto- all as per ser item no 37 above but as in trenches or floor |
| 39 | S&F in repair PVC (SWR) 75mm bore (dia) soil, waste and vent Pipe, (ISI Marked), in any length with rubber ring Joints fixed to wall with necessary stay clamps/ laid in trenches/floor etc complete all as specifed and directed. |
| 40 | .-Ditto- all as per ser item no 39 above but as in trenches or floor |
| 41 | S&F PVC (SWR) 110 mm bore (dia), Bends any type, etc. and Jointing with Solvent Cement, complete all as specified and as directed |
| 42 | S&F PVC (SWR) 75mm bore (dia), Bends any type, etc. and Jointing with Solvent Cement, complete all as specified and as directed |
| 43 | S&F PVC (SWR) vent cowl110mm bore |
| 44 | S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 1000 litres capacity, triple layered, hoisted and fixed in position including 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed to iron pipe, tank nipple and connected complete all as directed. |
| 45 | Cutting chases in brick/ block wall, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth |
| 46 | Taking down chowkhats or frames not exc.1.5 Sqm each with shutters (without taking off shutters from the frames) etc complete all as specified and directed by Engineer-in-Charge |
| 47 | Taking down chowkhats or frames exc. 1.5 sq. m and n exc 4.00 Sqm each with shutters (without taking off shutters from the frames) etc complete all as specified and directed by Engineer-in-Charge |
| 48 | Taking down shutters of any description exc 1 Sqm but n exc 2 Sqm each etc complete all as specified and directed by Engineer-in-Charge |
| 49 | S & F pressed steel door frame of size 100 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete all as specified, |
| 50 | M&L for 35 mm thick Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated |
| 51 | S&F Solid PVC Door frame size 50mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing |
| 52 | S&F factory made solid PVC moulded Door shutter with particle board core, 28 to 30mm thick (stiles) with 2,4 or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back space, supplying and fixing in frame at site as per specification & drawing. |
| 53 | S&F powder coated aluminium anodised aluminium frame, shutters for door,windows, ventilators with one or more rebates including joining cleat for fixing etc, rubber / neoprene beading and locking arrangement etc complete all as specified and directed by Engr-in-Charge |
| 54 | S&F anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified |
| 55 | S&F butt hinges medium weight cold rolled mild steel 100mm long. |
| 56 | S&F aluminium anodised barrel tower bolts of extruded section 150mm long. |
| 57 | S&F aluminium anodised handle of extruded section 150mm long. |
| 58 | S&F aluminium alloy, anodised, sliding door bolt with hasp, staple and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy 300mm long. |
| 59 | S & F in repair Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40 mm and fixed in any position any type of opening with and including wooden beads complete all as directed by Engr-in-Charge. |
| 60 | S & F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40 mm and fixed in any position any type of opening with and including wooden beads complete all as directed by Engr-in-Charge. |
| 61 | S&F 150mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring. |
| 62 | Hacking out old broken glass ( any thickness size ,quality or description ) from wooden/Steel frames glazed with putty or fixed with beads. |
| 63 | M & L for 3 mm thick sheet frosted/pin headed glass ordinary quality and glazing with oil putty or wooden beads in squares n.exc 0.50 sqm in each pane. |
| 64 | M & L for 4 mm thick plain sheet frosted/pin headed glass ordinary quality and glazing with oil putty or wooden beads, rubber bedding in squares n.exc 0.50 sqm in each pane. |
| 65 | M & L for preparation of new wooden surface and applying two coats of synthetic enamel paint over a coat of pink primer complete all as directed. |
| 66 | M & L for preparation of old wooden surface and applying one coat of synthetic enamel paint. |
| 67 | M & L for preparation of new steel surface and applying two coats of synthetic enamel paint over a coat of red oxide. |
| 68 | M & L for preparation of old steel surface and applying one coat of synthetic enamel paint. |
| 69 | S & F in repairs 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers. |
| 70 | S&F curtain rod 20mm dia, having corrugated PVC extrusion on eletric resistance welded MS pipe with fancy type 02 nos Knobs and 02 Nos brackets per each door/ windows etc complete all as specified and directed |
| 71 | S&F PVC (SWR) Nahani /Floor trap, 75 mm dia of out let, plain with grating including jointing to waste pipe with solvent cement. |
| 72 | Dismantling of unframed work fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section |
| 73 | M&L for Framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors ladders framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 74 | Dismantling of framed timber scantling 40 Sq, Cm and over in section, in any position |
| 75 | M&L for pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour 0.50mm thick (total coated thickness), 550 Mpa minimum, yield strength. It shall be coated with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having overall width and laid width as specified and shall be fixed using hot dip galvanized, self drilling and self tapping screws neoprene and EPDM washers. Penetrations and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners. including dismantling existing sheets etc complete all as directed |
| 76 | M&L for pre- painted galvalume aluminum zinc coating GI based plain steel sheet of any colour 0.50mm thick (total coated thickness), 550 Mpa minimum, yield strength. It shall be coated with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having overall width and laid width as specified and shall be fixed using hot dip galvanized, self drilling and self tapping screws neoprene and EPDM washers. Penetrations and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners. including dismantling existing sheets etc complete all as directed |
| 77 | S&F in repairs for false ceiling with Vinyl faced Arm-Gyp-FB, ceiling 600 x 600 x 9mm thick with washable metalized polyester foil backing with Vinyl covered edges, supporting sections shall be of suitable size from same makes embossed on sections and level adjuster duly suspended by 2 mm dia GI wire fixed to roof at 600mm centre to centre as per manufacturer's instructions / specification and all as directed including taking down/ out existing. |
| 78 | S&F of Steel work in tubular trusses, Perlin, rafhter, including special shaped washer etc. complete conforming to I. S.1161-1979 grade St.-240 |
| 79 | S&F of steel work in post, Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. as per Fe 410 -W (Gde- E- 250) quality- A |
| 80 | S&F structural rolled mild steel Fe 410-00 (Gde E-250) Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment |
| 81 | M&L Providing cement concrete Type C1 1:3:6 20mm graded aggregate) in kerbs or mud stops, rounded or chamfered on edges. |
| 82 | Taking down carefully copper/aluminum point wiring (light/ fan/ bell/ socket, power point etc) complete, including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors etc complete all as specified and directed Engineer-in-Charge |
| 83 | M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable drawn in and incl PVC Casing and capping ISI Marked with its accessories PVC boxes (upto 12 module ) for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable as earth continuity conductor to common earth & connecting to earth dolly for the following, all as specified and directed. Note :1. Proper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black)2. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, ceiling lights, bulkhead lights, bldg security light etc |
| 84 | One light point/fan point/bell point controlled by switch 5 Amp single pole one way |
| 85 | One 3 pin 5 Amp socket outlet on same board controlled by one, one way 5 Amp switch |
| 86 | One socket outlet 5/3 pin 5 Amp controlled by one switch on independent board |
| 87 | .-ditto- all as per ser Item No 83 (here-in-before) but with 2.5 Sqmm Copper conductor cable for Phase , Neutral and Earth for one 3 pin, 15 Amp socket outlet on independent board |
| 88 | S&F Modular Switch, 6 Amp, one way, one Module. etc complete all as specified and directed by Engineer-in-Charge |
| 89 | S&F Modular Switch, 16 Amp, one way, one Module. etc complete all as specified and directed by Engineer-in-Charge |
| 90 | S&F Modular Socket Outlet 6 Amp, 3 pin, combined two module etc complete all as specified and directed by Engineer-in-Charge. |
| 91 | S&F Modular Socket Outlet 6 Amp / 16 Amp - 6 pin combined two module etc complete all as specified and directed by Engineer-in-Charge |
| 92 | S&F Modular Fan Regulator Fan step regulator, 120 Watt - two module etc complete all as specified and directed by Engineer-in-Charge |
| 93 | M&L ceiling rose 3 terminal / PVC / polycarbonate, isolated body etc complete all as specified and directed by Engineer-in-Charge |
| 94 | S & F reolacement Double door Sheet metal enclosures factory made DBs SPN, 8 way ,240 volts ,protection class IP-42, suitable for fixing of MCBs,, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 200 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed.Note:- MCBs will be measured and paid separately. |
| 95 | Supply & fix MCB , SP, AC, 240 Volts of 06 to 40 Amp capacity 10 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge |
| 96 | Supply & fix MCBs, SPN, AC, 240 volts of 40 Amps capacity 10 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge |
| 97 | S&F Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack LED Tube light fitiing 20 Watt with LED light source 6500 K with uniform light output, with all accessories including its connection with 2 core seathed copper conductor cable of size 0.5 Sqmm with etc complete all as specified and directed by Engineer-in-Charge. |
| 98 | Supply & fix energy saving and environmental friendly long life LED street light 35 Watt (Bldg security light) made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08 fixed on wall with GI pipe of suitable dia and all fixing accessories including connecting up with & including twin core twisted flexible copper conductor cable of suitable size of 230V , 50 HZ etc complete all as specified and directed by Engineer-in-Charge. |
| 99 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230 V 50 HZ RPM 1200 copper winding of sweep 200 mm |
| 100 | Taking out/down and opening of existing ceiling fans 1200 mm sweep/exhaust fan of any size/electric meter from any position, of any make etc & refixing at the desired location after reassembling and after servicing/overhauling by thouroghly cleaning the shaft,rotor,stator and applying lubricant/grease to bearings and one coat of super enamelled varnish over winding to improve the insulation resistance including repair /replacement of spare parts/ material /items, making connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.50 Sqmm upto 0.50 Mtr length including using material/parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional complete all as specified and as directed. |
| 101 | Supply and fix in replacement capacitor 2.5/3 mfd 250 V AC etc,complete all as specified and directed by Eng-In-charge |
| 102 | Supply and fix in replacement ceiling fan canopy set of two of suitable size of ceiling fan etc etc, complete all as specified and directed by Eng-In-charge. |
| 103 | Supply and fix in replacement Ball bearing No6201&6202 etc etc, complete all as specified and directed by Eng-In-charge |
| 104 | Supply and fix in replacement of down rod of suitable length made out of 15 mm bore medium grade GI pipe with & including clamp nuts bolts, split, pins, washer, threading etc making connection to make it functional etc, complete all as specified and directed by Eng-In-charge |
| 105 | S&F sub main wiring with 4 Sqmm single core, 2 Run PVC insulated,unsheathed, FRLSH stranded copper conductor cable with 4 Sqmm,one Run PVC insulated, unsheathed, FRLSH stranded copper conductor cable as earth wire drawn through and including Concealed in wall with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Engineer-in-Charge.Note : 3 runs of 4 Sqmm conductor and one run of PVC conduit min 25 mm dia shall be measured as one unit RM length. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysAug 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender