Tender For Construction of Sari Bhawan At Kugti In Tehsil Bharmour Distt. Chamba H.P (Sh:- Providing electrical installation Therein).
Tender Value
1.68 Lakhs
Estimated cost
Bid Submission
27 Jul 2026
6 days left
EMD
3400
Bank guarantee accepted
Document Fee
350
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chamba → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction of Sari Bhawan At Kugti In Tehsil Bharmour Distt. Chamba H.P (Sh:- Providing electrical installation Therein).
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cablein surface/recessed steel conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. Group C. |
| 2 | Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.2x2.5 Sq. mm. |
| 3 | Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.2x4.0 Sq. mm. |
| 4 | Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.2x6.0 Sq. mm. |
| 5 | Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.2x10 Sq. mm. |
| 6 | Wiring for circuit / sub-main with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. (4X4+2X4)HRFRLS/PVC insulated single core copper conductor cable for earthing as required.Make:- KEI/Anchar/ Polycab |
| 7 | Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required.PVC insulated HRFR LS Copper conductor 1.5 Sq. mm.Make:- KEI/Anchar/ Polycab3x2.5 Sq. mm. |
| 8 | Supplying and fixing metal box of 150mmx75mmx60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in FRLS on including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps paino type switch, connection painting etc. as required (For light plugs to be used in non residentail building). |
| 9 | Supplying and fixing metal box of 180mmx100mmx60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in FRLS on including providing and fixing 6 pin 15/16 amps socket outlet and 15/16 amps paino type switch, connection painting etc. as required (For light plugs to be used in non residentail building). |
| 10 | Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- Make:-Usha/Bajaj/CromptonExhaust Fan, Light duty, (Domestic) 300 mm sweep. |
| 11 | Providing and fixing decorative extruded tube ficture having high quality design suitable for LED tube up to 20 watt (2000 lumens) 6500K and it should be compatible with specifications i.e. power factor> 0.9 harmonic distortion < 10% and efficacy > 100 lumens per watt CRI >80, suitable for input voltage AC 220-240V. 50/60 Hz including one no tube rod 20 watt complete with all accessories, connections, testing and commissioning etc. as required.LED Tube Fixture 20 watt. Cat. No. BCLAB 20WLEDP .Cat No. LL20-111-111-XXX-65NE3 |
| 12 | Providing and Fixing of IP20 LED fixture of 12 watt +/- 1 W LED Surface Mounted Downlighter Square Shape with minimum system lumen efficacy of 100 lm/W with Polycarbonate housing,pressure die cast heat sink and P.F.>0.95 with THD<10% ,CRI 80.The LED shall be tested with LM80-08 standard with Useful life of 50000 Hrs at L70 . The LEDs used in the luminaire shall have CCT of ANSI Bin 5700 K with CRI of minimum 80.The Input voltage range shall be 150V to 270V, 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects. LED Surface mounting Square downlighter-12 watt |
| 13 | Supplying and fixing bakelite batten/ angle holder including connection etc. as required. |
| 14 | Supplying & fixing following type of Surface mounted luminaires, white power coated CRCA housing diffusser to avoid glaire,it should be compatible with specification i.e. Power Factor > 0.9, Harmonic Distortion < 20% and efficacy > 100 Lumens per watt, CRI rating> 70 suitable for input voltage: AC 220-240 V, 50 Hz, complete with all accessories, connections, testing and commissioning etc. as required.LED Batten Light 10W. |
| 15 | Supplying and fixing of fancy wall bracket suitable for input voltage:AC 220-240V,50/60Hz, complete with all accessories ,lamp holder, LED lamp including making connectons,testing etc. as required: of Approved .Fancy Wall light fixture Metal body,suitable for 7 W retrofit LED lamp. |
| 16 | Providing and fixing IP65 Bulk head led fixture 10 watt +/- 1 wall Mounted with minimum system lumen efficacy of 100 lm/W with pressure die Cast Aluminum housing Polycarbonate Opal Diffuser and P.F>0.95 with THD<10% CRI 80. The LED Shall be tested with LM80-08 standard LED Bulk head Light 10Watt. |
| 17 | Supplying and fixing LED retrofit lamp suitable for B-22 holder base fittings with polycarbonate diffuser and aluminium heat sink as required complete in all respects.9Watt LED, B-22 |
| 18 | Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-Make:- L&T/ Legrand/ SchneiderDouble door-4 way |
| 19 | Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-Make:- L&T/ Legrand/ SchneiderDouble door-12 way |
| 20 | Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of Single pole in the existing MCB DB complete with connections etc. as required:- Cat-A.Make:- L&T/ Legrand/ Schneider |
| 21 | Providing and errection of LED 45 watt Street light luminaries, powder coated pressure die-cast aluminium SMDLED Street light with heat resistant toughened glass including connections, testing and commisioning etc. as required.Make:Jquar/Panasonic/ WiproStreet Light 45W |
| 22 | Supplying and fixing Following. rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amps |
| 23 | Supplying and fixing Following. rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps |
| 24 | Supplying and fixing followinng rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amps |
| 25 | Supplying and fixing followinng rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps |
| 26 | Earthing with G.I. earth plate 600 mmx600 mmx 6 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt ) as required. |
| 27 | Supplying and laying 6 SWG G.I. wire at 0.50 mtr. below ground level for earth electrode conductor, including soldering etc. as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysJul 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender