Tender for Renovation Of Room No 513 In Msg For Science Block In Ncess C Us

BOQ

Name of Work:- Renovation of Room No 513 in MSG for Science Block in NCESS C us
Sl. No. Item Description
1Part A (Civil Works)
2Painting
3Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
4Interior wall Surface Water proofing of Dr. Fixit Dampguard is a two-component coating composed of epoxy resin, curing agent, inert pigments & properly selected fine fillers, additives in water as a medium. It has an advantage of dilution with water for application over cementitious surfaces. It is used as internal coating for the damp-proofing treatments of internal wall. It has excellent water resistance, adhesion, hardness & toughness and sets faster similar to solvent based epoxy formulations. Clean the existing painted surface by scraping, removing dust, and washing it thoroughly with water, Fill the cracks & grooves with Dr. Fixit Dampguard and cement modified putty & allow it to dry for at least 24 hours.Apply the first brush coat of mixed quantity (1:1:1 - base :hardener : water) of Dr. Fixit Dampguard. Allow drying for 6 to 8 hrs.Apply second brush coat of mixed Dr. Fixit Dampguard. Allow it to cure completely for 24 hours . Coverage Dr. Fixit Dampguard as a coating: 6 to 8 m2 per kg per coat.
5Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
6Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :
7Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm
8Flooring Tiles
9Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
10For thickness of tiles above 25 mm and up to 40 mm
11Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge
12In cement mortar
13Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
14Nominal concrete 1:4:8 or leaner mix (including equivalent design mix)
15Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
16Repair to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, allcomplete as per the direction of Engineer-In-Charge.
17Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/oralkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.
18In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand)
19Acid and alkali resistant tile
20In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand)
21Acid and alkali resistant tile
22Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.
23Size of Tile 600x600 mm
24Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
251:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
26Plumbing / False ceiling
27Dismantling of sanitary fixtures comprising kitchen sink/wash basin/flush tank of any size, type and material, including all fittings, brackets, traps, waste and flush pipes, cutting and disconnecting water supply and drainage connections, plugging/sealing exposed lines, stacking serviceable materials and disposal of unserviceable materials within 50 m lead, complete as directed by the Engineer-in-Charge.
28Dismantling W.C. Pan of all sizes including disposal of dismantled materials including malba all complete as per directions of Engineer-in-Charge.
29White Vitreous China Flat back wash basin size 450x 300 mm with single 15 mm C.P. brass pillar tap
30Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
31Flexible pipe
3232 mm dia
33Providing and fixing CP Brass 32 mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
34Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
3515 mm nominal bore
36Providing and fixing C.P. brass soap dish with holder, complete with all fittings and fixtures, including cutting and making good the walls, complete in all respects as directed by Engineer-in-Charge.
37Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVCplain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
3815 mm nominal dia Pipes
3920 mm nominal dia Pipes
40Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge External work
4140 mm nominal dia Pipes
42Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
43Cement mortar 1:4 (1 cement : 4 coarse sand)
4412 mm cement plaster of mix :
451:4 (1 cement: 4 fine sand)
46Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-incharge.
47Taking out doors, windows and clerestory window shutters (steel or wood)including stacking within 50 metres lead :
48Of area 3 sq. metres and below
49Providing labour for disassembling and shifting of existing modular work stations (2 Nos., each of 4.0 m length) and modular conference table set comprising two rectangular tables of size 2.70 m × 0.60 m × 0.75 m each and one half-circular table of size 1.40 m × 0.70 m × 0.75 m, including careful disassembly of modular components without damage, removal of nuts, bolts, screws, brackets and other accessories, handling, stacking and shifting to the designated location within the premises, complete with all labour, tools and tackles required for satisfactory completion of the work,(if required assemble) as directed by the Engineer-in-Charge.
50Fitter (grade 1)
51Beldar
52Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for serviceslike diffusers, grills, light fittings, fixtures, smoke detectors etc.
53Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawingsand as directed by Engineer-in-charge.
54GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.
55Windows and Door Repair
56Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
57For fixed portion
58Powder coated aluminium (minimum thickness of powder coating 50 micron)
59For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
60Powder coated aluminium (minimum thickness of powder coating 50 micron)
61Supplying and fixing I- max hinges
62Supplying and fixing Aluminium handle with locking arrangements suitable for aluminium windows
63Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete.
64Powder coated minimum thickness 50-micron aluminium
65Providing and fixing aluminium casement stays, ISI marked, anodised(anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc.complete.
66Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
67With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
68Providing and fixing 4 mm thick Aluminium Composite Panel (ACP), double-side coated and factory finished on both faces, in panelling to aluminium doors, windows, shutters, partitions and similar works, fixed with suitable aluminium sections, approved fasteners, fixtures, sealants and accessories, complete in all respects as per architectural drawings and the directions of the Engineer-in-Charge.
69Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete
70Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
71Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality withnecessary screws etc. complete.
72Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in-charge.
73Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
74125mm
75Providing and fixing powder coated aluminium framed openable magnetic mosquito 304 grade ss mesh shutter with fiberglass insect screen, complete with magnetic locking arrangement, hinges, handle, spline gasket and all necessary fittings and fixtures, complete as directed by Engineer-in-Charge
76Supply and fixing of Sun control flim on windows shutter glass and fixied glass Hi-COOL SRC-05 preparing the surface smooth including necessary pasting arrangements etc.,all complete as per instruction of Engineer in charge. Note : Wastage is not considered for paymentMake : Hi-cool , 3M
77Melamine polishing on wood work (one or more coat).
78Sub Total (Civil)
79Total Amount for Non-DSR Items
80Total Amount for DSR Items
81Modified cost on DSR item after using Correction factor on DSR 2023 on account of GST@ 0.973
82add 36% towards cost index
83Grand total (Part-A)
84Part-B (Electrical)
85Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C
86Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
87Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
88Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 4 sq. mm
89Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.6 x 4 sq. mm
90Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 6 sq. mm
91Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.5 x 6 sq. mm
92Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
93Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire
94Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire
95Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 X 10 sq. mm + 2 X 6 sq. mm earth wire
96Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm)
97Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.3 Module (100mmX75mm)
98Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.8 Module (125mmX125mm)
99Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 A switch
100Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 A socket outlet
101Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.telephone socket
102Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.data socket outlet
103Supply,Installation, testing and commissioning following sizes of 250 mm plastic body exhaust fan in the existing opening including making good the damages, connections, etc. as required.
104Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way (4 + 24), Double door
105Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way , Double door
106Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
107Supplying and fixing rating, 240/415 V, following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.63A ,TP
108Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A
109Supplying and fixing following rating, four pole, MCCB,25KA, 415 volts in the existing MCB DB complete with connections, testing and commissioning etc as required.100 A,25KA,4P MCCB
110Supplying and drawing following pair 0.5 mm dia FRLS/HFFR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.1 Pair
111Supplying and drawing following pair 0.5 mm dia FRLS/HFFR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair
112Supply,installation , testing & commissioning of UTP CAT 6 LAN cable in existing surface/recessed steel/PVC conduit/under floor trunking/ cable management system as required.1 run of Cable
113Supply,installation , testing & commissioning of UTP CAT 6 LAN cable in existing surface/recessed steel/PVC conduit/under floor trunking/ cable management system as required.2 run of Cable
114Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required.
115Supplying and fixing DP sheet steel enclosure on surface/ recess along with 63A/40A, 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required.
116Supplying and fixing TP sheet steel enclosure on surface/ recess along with 63 A ,415 V \\"C\\" curve TPN MCB complete with connections, testing and commissioning etc. as required.
117SITC of Indoor 2feet x2feet square type 30/36W LED lighting luminaire of cool day light output and the following specifications: Lumen output: Not less than 3300lm; Efficiency: 100 lumen/watt; Make: Philips / Wipro , Bajaj or Crompton ,Havells
118supply, Installation, Testing and Commissioning of pre-wired,4feet ,24W LED tube light fitting complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. as required.
119Supplying of XLPE insulated, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade conforming to IS: 7098 ( Part-I) with up-to-date amendments of following sizes as required.3.5 x 70 Sq.mm
120Supplying of XLPE insulated, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade conforming to IS: 7098 ( Part-I) with up-to-date amendments of following sizes as required.3.5 x 95 Sq.mm
121Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
122Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 35 sq. mm and upto 95 sq. mm
123Supplying and making end termination with brass compression gland and aluminium lugs for following sizes of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 70 sq. mm (38mm)
124Supplying and making end termination with brass compression gland and aluminium lugs for following sizes of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 95 sq. mm (45mm)
125Supply ,Installation, testing & commissioning of cubicle type Panel suitable for 415V,3 phase, 4 wire 50 Hz AC supply system having required front surface area Approx and 300mm depth fabricated in compartmentalised design from CRCA Sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning and finishing complete with 7 tank /abrasive blasting process for powder coating in approved shade, having 160amps capacity TPN Aluminium bus bar of high conductivity, DMC/SMC bus bar supports, with short circuit withstand capacity of 31MVA for 1 sec., bottom base channel of section not less than 75mm X75mm X 5mm thick with following fabrication shall be done in transportable section.Entire panel shall have a common GI earth bar of size 32mm X 5mm at the rear with 2 nos. earth stud, solid connections for main bus bar to switch gears with required size of copper bus bars and control wiring with 1.5 sq.mm. FRLS PVC Insulated copper conductor single core cable, cable alleys, cable gland plates in half, MV danger notice board i/c providing following switch gears complete as required .
126Incomer:
127a)160 Amps, 4P, 25 KA MCCB (Ics = 100% Icu) with thermal magnetic release for over current, short circuit Release, extended rotary handle etc 1 No.
128Bus Bar
129160 amps 4 strip Copper Bars of suitable size with a current density not more than 1.2A / Sqmm. The bus bars shall be sleeved with colour coded heat shrinkable PVC sleeves. The bus bars shall be supported at suitable intervals with SMC / FRP supports as per relevant standards.
130Outgoings:
1312NoS 100A FP 25kA ,2Nos 125A FP 25kA thermo-magnetic release type MCCB complete with operating handle, spreader links, phase barriers etc.
1323Nos 63A FP 16 kA thermo-magnetic release type MCCB complete with operating handle, spreader links, phase barriers etc.
133Indication lamps ,Metering modules -1set each
134Dismantling of all old wirings,DB,switch boards,etc and handed over the same in the department store including transportation etc as required
135Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
136Sub Total (Electrical)
137Total amount Non DSR
138Total amount DSR
139CI 32.04 %
140Grand TOTAL (Electrical -B)
141Grand Total (A+B) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56563083
AUTHORITY Government Departments
TENDER VALUE 15.39 Lakhs
LAST DATE 10-08-2026
Authority
Authority Name National Centre For Earth Science Studies
Work Description Tender for Renovation Of Room No 513 In Msg For Science Block In Ncess C Us
Basic Detail
Tender No EAM/CW/12/2026/NCESS
Bidding Type Tender
Location
City Thiruvananthapuram
State Kerala
Key Dates
Publish Date 20 Jul 2026
Submission Date 10 Aug 2026
Open Date 12 Aug 2026
Finance
Tender Value 15.39 Lakhs
Tender Fee Ref. Documents
EMD 30797
Exemption Not Available
Document List
BOQ_964915.xls
f43f44ab-520e-4970-b027-5c227f39882a.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Aug 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_964915.xls

html

f43f44ab-520e-4970-b027-5c227f39882a.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders