Housing Urban and Rular Development Government Departments Closing in 3 days TDR #56562599

Tender For The Supply And Installation Of Air-Conditioning Units In The Courtrooms And Retiring Rooms Of The HonBle District Judge And Additional District Judge Under The Jurisdiction Of The District Court, Chitrakoot.

Issued by Government Departments · Chitrakoot, Uttar Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
25 Jul 2026
3 days left
EMD
4.20 Lakhs
Bank guarantee accepted
Document Fee
2354
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chitrakoot → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For The Supply And Installation Of Air-Conditioning Units In The Courtrooms And Retiring Rooms Of The HonBle District Judge And Additional District Judge Under The Jurisdiction Of The District Court, Chitrakoot.

BOQ

Name of Work:- tuin U;k;ky; fp+=dwV ds varxZr ekuuh; tuin U;k;k/khk ,oa vij tuin U;k;k/khk ds U;k;ky; d{kksa ,oa foJke d{kksa esa okrkuqdqyu l;a=ks dh vkiwfrZ ,oa LFkkiuk dk dk;ZA
Sl. No. Item Description
1Part-A ( Shedule Item ) (Control Panel, Cable etc) Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis indoor/outdoor type Electrical control panel with TPN ACB(65 KA,4Pole Elect draw out , Micor processer Release IPR2 ) and TPN MCCB's (Four Pole 36 KA with thermal magnatic release) Switches and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, istrument fuses, current transormer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/ DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches entry boxes shall be complete with suitable cable end boxes reverse. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above Will be provided with Amp Metre, current transfonners and selector switches etc and insurtrment fuse. The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6 mm/2mm. Cubicle type switch board shall be of cat B Only. Incomer (Mains):- 250 Amp /415Volt MCCB-1 Nos.Outgoing:- 63 Amp/415 Volt MCCB-4 No. 160 Amp/415 Volt MCCB-1 No
2Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis indoor/outdoor type Electrical control panel with TPN ACB(65 KA,4Pole Elect draw out , Micor processer Release IPR2 ) and TPN MCCB's (Four Pole 36 KA with thermal magnatic release) Switches and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, istrument fuses, current transormer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/ DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches entry boxes shall be complete with suitable cable end boxes reverse. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above Will be provided with Amp Metre, current transfonners and selector switches etc and insurtrment fuse. The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6 mm/2mm. Cubicle type switch board shall be of cat B Only. Incomer (Mains):- 160 Amp /415Volt MCCB-1 Nos.Outgoing:- 63 Amp/415 Volt MCCB-4 No.
3Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.
41. 300 Sq. mm 3½ core.
52.120 Sq. mm 3½ core.
6Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
71. 3½ X 300 sq. mm (82mm)
82. 3½ X 120 sq. mm (82mm)
9Supplying and fixing of following ways,horizatal three pole and neutral type, sheet stee 415 volts, MCB distribution board on surface/recess complete with tinned, copper bus bar, common neutral link, earth bar, din bar interconection ,power painted including earthing etc as required (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way(4 + 12), Double door
10Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing andcommissioning etc. as required. For 4 way Double Door
11Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. SPMCB
12Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
13Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (2 X 6 sq. mm + 1 X 6 sq. mm earth wire)
14Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (4 X 16sq. mm + 2 X 6 sq. mm earth wire)
15Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
16Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
17Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders,fastner etc as required.225 mm width X 50 mm depth X 1.6 mm thickness
18Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 100 mm dia
19Part-B ( Non Shedule Item )Providing and fixing following rating and breaking capacity and pole MCB with thermomagnetic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel, making connections, etc. As required.63 Amp. FP MCB
20Supply and fixing of fire extinguisher, ABC Type 4.00 Kg. Capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket light, along with supply of all materials and labour for proper completion of work.
21Supply and fixing of fire extinguisher, CO2 Type 4.5 Kg. Capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket light, along with supply of all materials and labour for proper completion of work.
22Fabrication of cage of iron Jali with outer M.S. Stand for Sub-Panel with door including all material & Labour complete in all respect. For sub panel size 6x4x7 feet
23Charges of Road/floor restoration after road cutting including cost of labour T&P material complete. RCC Road
24Supply and Laying of 1800 mm x 900 mm x 12mm. Thick chequred rubber matting of tested quality.
25Supply and fixingof shock treatment chart (Prescribed under I. E. rules) duly frame with glass & supported from back with hard board or soft board with supply of all material Labour T & P for copper compression of work.
26Supply and fixing of danger board fabricated from 10 gauge M.S. Sheet as per IE rule.
27Part-C ( AC & Stablizer Item )SITC of Air cooled Hi wall Inverter split type AC Complete with indoor unit, outdoor unit, concealed copper refigerant piping with insulation inverter type-cooling only 2.0 Tr 5 star BEE rating. The system shall be able to operate up to 52 degree C (Outdoor ambient temperature)
28SITC of Air cooled Hi wall Inverter split type AC Complete with indoor unit, outdoor unit, concealed copper refigerant piping with insulation inverter type-cooling only 1.5 Tr 5 star BEE rating. The system shall be able to operate up to 52 degree C (Outdoor ambient temperature)
29Part-D (Non Shedule Item )SITC of suction/discharge both copper pipe line in split A.C. unit 1.8/ 2.0 ton capacity including brazing, nitrile, rubber insulation 9 mm thick class 'O' etc. complete 3/8\\" (9.50 mm.) and 5/8\\" (15.90 mm)
30SITC of suction/discharge both pipe line in split A.C. unit 1.5 ton capacity including brazing, nitrile, rubber insulation 6 mm thick class 'O' etc. complete 1/4\\" (6.40 mm.) and 1/2\\" (12.70 mm)
31Supply and laying of heavy duty PVC plastic braided 20 mm. OD flexible pipe for condensed water with clipping accessories complete.
32S/l of Inter Connecting Electrical Cable for A.C (2.5 Sq. mm 3 Core.)
33S/l of Inter Connecting Electrical Cable for A.C (2.5 Sq. mm 4 Core.)
34Fabrication of M.S. Stand for Outer unit of A.C. with fixing on wall with all material & Labour complete in all respect. Size 3.75x1.75 feet with 4 Nos. hanging angle.
35Supply, fabrication and installation of MS Cage for protection of outdoor unit from animal theft LxWxH 1300 mmx600mmx1200mm complete in all respect.
3616 A 3 pin Plugtop with Indicator (Heavy Duty)
37SITC of 5 KVA automatic voltage stablizer (130-280V) copper winding.
38SITC of 4 KVA automatic voltage stablizer (130-280V) copper winding. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56562599
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 25-07-2026
Authority
Authority Name Public Works Department
Work Description Tender For The Supply And Installation Of Air-Conditioning Units In The Courtrooms And Retiring Rooms Of The HonBle District Judge And Additional District Judge Under The Jurisdiction Of The District Court, Chitrakoot.
Basic Detail
Tender No 1100C/4C-EMC/2026-27 Dt. 23.06.2026
Bidding Type Tender
Location
City Chitrakoot
State Uttar Pradesh
Key Dates
Publish Date 17 Jul 2026
Submission Date 25 Jul 2026
Open Date 25 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee 2354
EMD 4.20 Lakhs
Exemption Not Available
Document List
T2.pdf
Tendernotice_1 (29).pdf
8d9152dd-bc6c-47a8-a284-3af0e70248d7.html
BOQ_2195968.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Jul 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
pdf

T2.pdf

pdf

Tendernotice_1 (29).pdf

html

8d9152dd-bc6c-47a8-a284-3af0e70248d7.html

xls

BOQ_2195968.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders