| Sl. No. | Item Description |
| 1 | Part-A ( Shedule Item ) (Control Panel, Cable etc) Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis indoor/outdoor type Electrical control panel with TPN ACB(65 KA,4Pole Elect draw out , Micor processer Release IPR2 ) and TPN MCCB's (Four Pole 36 KA with thermal magnatic release) Switches and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, istrument fuses, current transormer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/ DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches entry boxes shall be complete with suitable cable end boxes reverse. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above Will be provided with Amp Metre, current transfonners and selector switches etc and insurtrment fuse. The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6 mm/2mm. Cubicle type switch board shall be of cat B Only. Outdoor type PanelIncomer :- 1250Amp./415 Volt ACB-1 No..Outgoing:-1000 Amp /415Volt ACB-01 Nos.Outgoing:-630 Amp /415Volt ACB-01 Nos.Outgoing:-400 Amp /415Volt MCCB-01 Nos.Outgoing:-250 Amp /415Volt MCCB-01 Nos. |
| 2 | Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis indoor/outdoor type Electrical control panel with TPN ACB(65 KA,4Pole Elect draw out , Micor processer Release IPR2 ) and TPN MCCB's (Four Pole 36 KA with thermal magnatic release) Switches and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, istrument fuses, current transormer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/ DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches entry boxes shall be complete with suitable cable end boxes reverse. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above Will be provided with Amp Metre, current transfonners and selector switches etc and insurtrment fuse. The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6 mm/2mm. Cubicle type switch board shall be of cat B Only. Outdoor type PanelIncomer (Mains):- 630 Amp. ACB manually operated drwout type ACB with microprocessor based O/L, S/& E/F Protection-1 Set.Outgoing:- 250 Amp /415Volt MCCB-2 Nos. 125 Amp/415 Volt MCCB-2 No. 100 Amp/415 Volt MCCB-2 Nos. |
| 3 | Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis indoor/outdoor type Electrical control panel with TPN ACB(65 KA,4Pole Elect draw out , Micor processer Release IPR2 ) and TPN MCCB's (Four Pole 36 KA with thermal magnatic release) Switches and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, istrument fuses, current transormer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/ DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches entry boxes shall be complete with suitable cable end boxes reverse. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above Will be provided with Amp Metre, current transfonners and selector switches etc and insurtrment fuse. The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6 mm/2mm. Cubicle type switch board shall be of cat B Only. Outdoor type PanelIncomer :- 250 Amp./415 Volt MCCB-1 No..Outgoing:- 63 Amp /415Volt MCCB-07 Nos., |
| 4 | Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis indoor/outdoor type Electrical control panel with TPN ACB(65 KA,4Pole Elect draw out , Micor processer Release IPR2 ) and TPN MCCB's (Four Pole 36 KA with thermal magnatic release) Switches and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, istrument fuses, current transormer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/ DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches entry boxes shall be complete with suitable cable end boxes reverse. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above Will be provided with Amp Metre, current transfonners and selector switches etc and insurtrment fuse. The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6 mm/2mm. Cubicle type switch board shall be of cat B Only. Outdoor type PanelIncomer :- 125 Amp./415 Volt MCCB-1 No..Outgoing:- 63 Amp /415Volt MCCB-03 Nos. |
| 5 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 6 | 1. 400 Sq. mm 3½ core. |
| 7 | 2. 300 Sq. mm 3½ core. |
| 8 | 3. 150 Sq. mm 3½ core. |
| 9 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 10 | 1. 3½ X 400 sq. mm (82mm) |
| 11 | 2. 3½ X 300 sq. mm (70mm) |
| 12 | 3. 3½ X 150 sq. mm (50mm) |
| 13 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way(4 + 12), Double door |
| 14 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator). 4 Way (4+12), double door |
| 15 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing andcommissioning etc. as required. |
| 16 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. For 4 way, Double door TPN MCBDB |
| 17 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. SPMCB |
| 18 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 19 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (2 X 6 sq. mm + 1 X 6 sq. mm earth wire) |
| 20 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (4 X 16sq. mm + 2 X 6 sq. mm earth wire) |
| 21 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 22 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 23 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 24 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 25 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastner etc as required.450 mm width X 50 mm depth X 2.0 mm thickness |
| 26 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastner etc as required.225 mm width X 50 mm depth X 1.6 mm thickness |
| 27 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 100 mm dia |
| 28 | Part-B ( Non Shedule Item ) (Control Panel, Cable etc) S/f Miniature Circuti Breaker (MCB) ‘C’ Curve(In accordance with IS/IEC 60898-1) 240 V, 50 Hz,10 kA Suitable for lighting and other domestic loads63 Amp. FP MCB |
| 29 | Supply and fixing of fire extinguisher, ABC Type 4.00 Kg. Capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket light, along with supply of all materials and labour for proper completion of work. |
| 30 | Supply and fixing of fire extinguisher, CO2 Type 4.5 Kg. Capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket light, along with supply of all materials and labour for proper completion of work. |
| 31 | Supply and Laying of 1800 mm x 900 mm x 12mm. Thick chequred rubber matting of tested quality. |
| 32 | Supply and fixingof shock treatment chart (Prescribed under I. E. rules) duly frame with glass & supported from back with hard board or soft board with supply of all material Labour T & P for copper compression of work. |
| 33 | Supply and fixing of danger board fabricated from 10 gauge M.S. Sheet as per IE rule. |
| 34 | Charges of Road/floor restoration after road cutting including cost of labour T&P material complete. RCC Road |
| 35 | Fabrication of cage of iron Jali with outer M.S. Stand for Sub-Panel with door including all material & Labour complete in all respect for main panel size 8x7x8 feet |
| 36 | Fabrication of cage of iron Jali with outer M.S. Stand for Sub-Panel with door including all material & Labour complete in all respect. For sub panel size 6x4x7 feet |
| 37 | Part-C (Supply & Installation of A.C.)SITC of Air cooled Hi wall Inverter split type AC Complete with indoor unit, outdoor unit, concealed copper refigerant piping with insulation inverter type-cooling only 2.0 Tr 5 star BEE rating. The system shall be able to operate up to 52 degree C (Outdoor ambient temperature) |
| 38 | SITC of Air cooled Hi wall Inverter split type AC Complete with indoor unit, outdoor unit, concealed copper refigerant piping with insulation inverter type-cooling only 1.5 Tr 5 star BEE rating. The system shall be able to operate up to 52 degree C (Outdoor ambient temperature) |
| 39 | Part-D (Non Shedule Item )SITC of 5 KVA automatic voltage stablizer (130-280V) copper winding. |
| 40 | SITC of 4 KVA automatic voltage stablizer (130-280V) copper winding. |
| 41 | SITC of suction/discharge both copper pipe line in split A.C. unit 1.8/ 2.0 ton capacity including brazing, nitrile, rubber insulation 9 mm thick class 'O' etc. complete 3/8\\" (9.50 mm.) and 5/8\\" (15.90 mm) |
| 42 | SITC of suction/discharge both pipe line in split A.C. unit 1.5 ton capacity including brazing, nitrile, rubber insulation 6 mm thick class 'O' etc. complete 1/4\\" (6.40 mm.) and 1/2\\" (12.70 mm) |
| 43 | Supply and laying of heavy duty PVC plastic braided 20 mm. OD flexible pipe for condensed water with clipping accessories complete. |
| 44 | S/l of Inter Connecting Electrical Cable for A.C (2.5 Sq. mm 3 Core.) |
| 45 | S/l of Inter Connecting Electrical Cable for A.C (2.5 Sq. mm 4 Core.) |
| 46 | Fabrication of M.S. Stand for Outer unit of A.C. with fixing on wall with all material & Labour complete in all respect. Size 3.75x1.75 feet with 4 Nos. hanging angle. |
| 47 | Supply, fabrication and installation of MS Cage for protection of outdoor unit from animal theft LxWxH 1300 mmx600mmx1200mm complete in all respect. |
| 48 | 25 A 3 pin Plugtop with Indicator (Heavy Duty) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender