Project Description
Tender for Mh- 4217 Tyadb (Trans Yamuna Area Development Board)Sub Work:- Construction Of Damaged Service Road On Left Side Of Trunk Drain No.-1 In Rohtash Nagar, Ac-64.
BOQ
| Sl. No. | Item Description |
| 1 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (including equivalent design mix). |
| 2 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 3 | Providing and laying in position cement concrete of specified grade excludingthe cost of centering and shuttering - 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 4 | Providing and laying factory made Precast concrete solid blocks of 200 mm thickness of grade M10 made of C&D waste from approved manufacturer in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand). |
| 5 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete:40 mm thick with 20 mm nominal size stone aggregate. |
| 6 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) with Neat cement punning. |
| 7 | Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required in gratings, frames, gurard bar, ladder, railings, brackets, gates and similar works. |
| 8 | Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate /retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. Note : Excess/less constructed then specified in this item is payable/recoverable seperately M-10 grade plain cement concrete ( cement content considered @ 220 kg /cum). |
| 9 | Providing and laying RMC of M-30 grade By using minimum 350kg of cement(43 grade, OPC) per cum of concrete in roads / streets manufactured in automatic RMC plant using coarse sand and graded stone aggregate of 20mm nominal size in appropriate proportion as per approved design criteria including transportation to site in transit mixer, including cost of admixture in recommended proportion as per IS9103 to accelerate/ retard setting of concrete to improve workability with out impairing strength and durability as per specification including spreading and compacting mechanically by using needle and surface vibratos, leveling to required slope & camber, finishing by floating & brooming with wire brushes etc. and curing including making provision for contraction / expansion, construction of cross / longitudinal joints of size 10mm wide 50mm deep by groove cutting machine, providing and filling joints with approved joint filler and sealants, etc. complete, as per direction of Engineer in-charge. (Cost of joint filler & sealants shall be paid for separately under relevant items). Note:- Cement content considered in M-30 is @ 350 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately M-30 RMC by using minimum cement @350 kg/cum. Cement concrete manufactured in automatic batching plant (RMC plant) including transportation to site in transit mixer. |
| 10 | Providing and fixing red sand slab 40mm thick over drain. |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :Foundations, footings, bases of columns, etc. for mass concrete |
| 12 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 13 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 14 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality HD-20 Circular shape 560 mm internal diameter. |
| 15 | Raising Manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required(Raising depth of Manhole to be paid separately ) Circular manhole 140cm width circular cover 600mm dia of grade EHD 35 |
| 16 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. Note - item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more |
| 17 | Supplying,Installation,Testing & Commissioning 6.00 mtr. height Hot Dip Galvanized G.I. Octagonal/Hexagonal Poles B, having thickness of Galvanization not less than 65microns, made up from minimum 3mm thickness Sheet, Bottom dia-130mm, Top Dia-70mm with 4 nos. foundation Bolt i.e of size 20mm x 600mm with anchor plate and having base plate of suitable size & thickness of base plate should not be less than 12mm with foundation accessories i.e. 20 mm. dia . bolt x 600 mm. length of 4 Nos. with anchor plate suitable for 6.00 mtr Octagonal/Hexagonal Poles and with Single Over head G.I. Bracket of 1 Mtr length complete in all respect as per specification & direction of Engineer-in-charge. (Make:- Bajaj/Volmont/ Lysaght/ Paruthi/ Crompton/ B.P.P/ Consoul or as approved by Engineer-in-charge) |
| 18 | Supplying, Installation, Testing and commissioning of 90 watt energy saving & environment friendlylong life L.E.D. street light with pressure die cast aluminnium housing reflector and enclosed with toughened glass complete with all accessories, (Model ENDURAOMNIPLUSSL 90W LED 757SASYTOPC) (Make:- Bajaj/ Halonix/ Havells/ Crompton/ Phillips or as approved by Engineer-in-charge). |
| 19 | Providing & laying the R.C.C. foundation with erection of 6.00 mtr. G.I. Hexagonal/ Octagonal Pole as per manufacturer recommendation by providing and laying in position 1:3:6 reinforced cement concrete foundation i/c excavation of earth, providing cutting, bending and placing in position, reinforcement TMT bars reinforcement ring of cold twisted bar with spacing as required with positioning of 4 Nos. foundation bolts suitable for 6.00 mtr pole with top thread and providing DWC, HPDE pipe for cable entry and exit as reqd. with materials, labour and foundation pedestal as per approved drawing complete as per specification & direction of Engineer-in-charge. |
| 20 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required 20(a) 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 21 | Supplying & Laying of one number PVC insulated armoured and PVC sheathed (General purpose) multi core cable with standard Aluminum conductor suitable for working voltage upto 1.1KV confirming to IS 7098/Part/1988 with amendment uptodate as required of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. 4x25 sqmm (Make- Havells / Polycab/ National/ Glouster/ Grandlay or as approved by Engineer-in-charge.) |
| 22 | Earthing with G.I. earth pipe 4.5 mtr long, 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. |
| 23 | Supplying and laying 6 SWG G.I. wire at 0.50metre below ground level for conductor earth electrode, including connection/termination with G.I. thimble etc. as required. |
| 24 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 24(a) Single pole |
| 25 | Supplying,Installation,testing and commissioning of street light Panel for automatic operation of street lights with Astronomical time switch of following configuration to be mounted in ferder pillar/Lighting DBs at sun set &sun rise or twilight(AutoON,Auto OFF,Auto mode)with manual override facility with 12/24 hours display format with suitable battery and indication for relay status i/c programming at site complete as required. 3 output (1 output per phase ) and suitable for three phase supply power connections by fixing the 125A TPN MCB-1 indicating LED fittings with 6 amp SP MCBs with Auto/Manual selector Switches etc as required. |
| 26 | Supplying, Installation, Testing & Commissioning of 1.5 sqmm ISI marked, FRLS PVC insulated, single core copper conductor cable on existing street light poles for supplying current to LED strip lights. (Make- Havells / Polycab/ National/ Glouster/ Grandlay or as approved by Engineer-in-charge.) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayJul 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender