| Sl. No. | Item Description |
| 1 | Providing EI |
| 2 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 3 | OD367018/2025-2026:Dismantling existing ordinary type tube /choke from fittings and Supply,Conveyance,installation, testing and commissioning of 1x18W/20W LED pre-wired G13 base with extruded heat sink LED Tube poly carbonate body (cool white at 6500 K temprature ) 1200 mm, T8 I, 18 /20w with nominal system level lumen pakage of 2100 Lumen having effiency of minimum 110umen/watt, Inbuilt Driver with THD <10%, power factor >0.95, RoHS compliant,, suitable for use 140~280V AC 50 HZ AC supply. The light shall be made by Polycarbonate housing (IP20 protection) with minimum 2.53 KV surge protection. . The light should have minimum 70% of light at 40000 Hr life time as per LM 79 NABL Accradation certification. LED used in this light should be from manufacturer of Lumileds/Osram/Cree/Nichia make. . |
| 4 | OD367019/2025-2026: Dismantling existing ordinary type tube fitting from RB/Chain / Stiff and Supply,Conveyance,installation, testing and commissioning of 2x18/20W LED pre-wired G13 base extruded aluminium heat sink type Box type Double tube light fitting made of CRCA sheet of minimum 0.5mm thickness with powder coated whole body complete with all accessories like wiring, end cap, side holer , knockout etc including single piece LED tube light having specification: double side pin type single piece indoor LED Tube poly carbonate body and extruded aluminum type (cool white at 6500 K temprature ) 1200 mm, T8 I, 18/20 w with nominal system level lumen pakage of 2100 Lumen having effiency of minimum 110 lumen/watt, Inbuilt Driver with THD <10%, power factor >0.95, RoHS compliant, suitable for use 140~280V AC 50 HZ AC supply. The light shall be made by Polycarbonate housing (IP20 protection) with minimum2.5 3 KV surge protection. . The light should have minimum 70% of light at 40000 Hr life time as per LM 79 NABL Accradation certification. LED used in this light should be from manufacturer of Lumileds/Osram/Cree/Nichia make. Fittings fixed directly on wall or ceiling with existing round block or existing Stiff and giving connection with existing length of 16/0.20mm 3 core copper conductor flex wire and giving connections as required. |
| 5 | OD367020/2025-2026:Dismantling existing ordinary type tube fitting from RB/Chain / Stiff and Supply,Conveyance,installation, testing and commissioning of 1x18/20W LED pre-wired G13 base Box type single tube light fitting made of CRCA sheet of minimum 0.5mm thickness with powder coated whole body complete with all accessories like wiring, end cap, side holer , knockout etc including single piece LED tube light having specification: double side pin type single piece indoor LED Tube poly carbonate body (cool white at 6500 K temprature ) 1200 mm, T8 I, 18 w with nominal system level lumen pakage of min 2100 Lumen having effiency of minimum 110lumen/watt, Inbuilt Driver with THD <10%, power factor >0.95, RoHS compliant, Surge 2.5/3 KV, suitable for use 140~280V AC 50 HZ AC supply. The light shall be made by Polycarbonate housing (IP20 protection) with minimum 3 KV surge protection. . The light should have minimum 70% of light at 40000 Hr life time as per LM 79 NABL Accradation certification. LED used in this light should be from manufacturer of Lumileds/Osram/Cree/Nichia make. Fittings fixed directly on wall or ceiling with existing round block or existing Stiff and giving connection with existing length of 16/0.20mm 3 core copper conductor flex wire and giving connections as required. |
| 6 | OD86446/2026-2027:Dismantling existing T5 type single/double tube fittings from RB/Stiff /Chain, remove existing choke and FL tube, cleaning the fitting and shade neatly with cotton waste and spirit, Supply and providing of 1x13W LED Tube light in the existing Single/double tube light fittings having specification: double side pin type single piece indoor LED Tube polycarbonate body (cool white at 6500 K temperature ) 1200 mm, T5, 13 w with nominal system-level lumen efficiency of minimum 120 lumen/watt, Inbuilt Driver(2W) with THD <15%, power factor >0.95, RoHS compliant, suitable for use 140~280V AC 50 HZ AC supply. The light shall be made by Polycarbonate housing (IP20 protection) with extruded Aluminium Chanel. The luminaries/lamp Should have a minimum 70% of light at 40000 Hr lifetime as per LM 79 NABL Accreditation certification, including rewiring the fittings suitable for a single LED batten and fix the entire fittings as the same position as required. |
| 7 | OD85659/2026-2027:Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required: |
| 8 | OD338602/2025-2026:Supply and fixing of 7W/9W LED Bulb |
| 9 | OD85673/2026-2027:Supply Conveyance, installation, testing and commissioning of 10W LED bulk head fittings suitable for surface and wall mounting output greater than 100 lumen/W 6500 Kwith power factor greater than 0.95 at full load, poly carbonate body & poly carbonate diffuser cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. including fixing as required DEWTON LYRA or its equivalent |
| 10 | 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 11 | 90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 12 | 90.15.4.1:Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 13 | OD85930/2026-2027:Supply and fixing Conveyance, installation, testing and commissioning of 1200 lumen round/ square surface mount fitting made of diecast aluminium, having efficacy not less than 100l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/NicheaS directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required |
| 14 | OD338837/2025-2026: Supply and fixing 1800 lumen round/ square surface mount fitting made of diecast aluminium, having efficacy not less than 100l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea complete with all accessories directly on wall or ceiling and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required. |
| 15 | OD338669/2025-2026:Supply Conveyance, installation , testing and commissioning of exhaust fans of size 300/305 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C single phase A/C existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan. |
| 16 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 17 | OD86594/2026-2027:Supply Conveyance, installation, testing and commissioning of 100W LED high bay luminaire output greater than 150 lumen/W 5700 K with IP 65 protection LED Chip make Lumiled, Osram or Bridgelux with power factor greater than 0.95 at full load, internal surge protection up to 4 KV,and corrosion proof LM6 grade pressure die cast aluminium body & poly carbonate diffuser cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be separately accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 18 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 19 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 20 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 21 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 22 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 23 | 1.28.1:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module |
| 24 | 1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 25 | 1.28.3:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module |
| 26 | 1.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module |
| 27 | 1.28.5:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module |
| 28 | 1.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module |
| 29 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 30 | OD338596/2025-2026:Supply and fixing 2.5 mfd. Ceiling Fan Capacitor, ISI marked etc as required |
| 31 | 90.3.18.2:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps |
| 32 | OD367134/2025-2026:Charges Painting of stiff (fan/tube) in installed position with one or more coats of Brush paintingwith synthetic enamel paint of approved brand and Colour as required. |
| 33 | OD367135/2025-2026:Urgent maintenance of Electrical installation including attending petty repairs , cleaning, of light fittings ,ceiling fan and exhaust fan ,checking all electrical connection in the DB and switch board. |
| 34 | OD367204/2025-2026:Charges for maintenance of existing Plate Earthing including accessories, and removing masonry enclosure and cleaning the earth chamber and replacing damaged nut and bolt if required and checking all connection , re legging and checking earth reading with megger etc. |
| 35 | OD85677/2026-2027:Supply and fixing ofSelf-adhesive vinyl sticker for lettering and figures of sizes and colour selected by the Engineer in charge for the identification mark to fan, AC, SB, DB, panel board , fire etc as required |
| 36 | OD367221/2025-2026:Charges for Painting of Exhaust fan in installed position with one or more coats of painting with synthetic enamel paint of approved brand and colour including checking bearing greasing and inter connections etc and tightening the connections etc as required |
| 37 | OD86636/2026-2027:Providing and fixing scaffolding system up to 10 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, , M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- The Height of the scaffolding shall be measured for payment purpose. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender