Tender For special Repair To Bldg No Top/21/85 Officer Mess At Unit Loc In Bomdila And Bldg Nos Tw-82 And Tw-87 Of Sikh Li, Provn Of Lt Panel, Ug Cable At Sikh Li And Street Light At Pathway From Qg To Sp Ukdd Of Maratha Li Of Age B/R And E/M Under G
Tender Overview
Project Description
Tender for special Repair To Bldg No Top/21/85 Officer Mess At Unit Loc In Bomdila And Bldg Nos Tw-82 And Tw-87 Of Sikh Li, Provn Of Lt Panel, Ug Cable At Sikh Li And Street Light At Pathway From Qg To Sp Ukdd Of Maratha Li Of Age B/R And E/M Under Ge Tenga
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of plain or corrugated steel sheeting any gauge, thickness as in roof covering complete all as specified and directed |
| 2 | S & F 0.50 mm thick Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 3 | S & F 0.50 mm thick Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as inroof covering/cladding to wall, fixed with self tapping screws as specified. |
| 4 | Supply and fix, 0.63 mm thick corrugated galvanised mild steel sheeting (minimum 275gm/sqm galvanising) with two corrugations side lap, fixed with L type or J type or cranked hooks , bolts and washer in roof, complete, all as specified and directed. |
| 5 | Supply and fix plain galvanised mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashing of 0.80mm thickness (minimum 275gm/sqm galvanising) complete all as specified and directed. |
| 6 | Taking down chowkats or frames with shutter (without taking off shutter from the frame) exc 1.50 Sqm but n exc 4.0 Sqm each including iron mongeries complete all as specified and directed. |
| 7 | Supply and fix 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed |
| 8 | S& F 2nd class hardwood 30mm thick Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed |
| 9 | Taking down chowkats or frames with shutter (without taking off shutter from the frame) n.exc 1.50 Sqm each including iron mongeries complete all as specified and directed. |
| 10 | S&F 2nd class hard wood 30mm thick Glazed and skeleton shutters, divided into squared, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (a); supplied and fitted to chowkats complete all as specified and directed |
| 11 | S&F 35mm thick factory made plain, framed, panelled shutter with lock rail and 12 mm thick veneered particle board with commercial vineering on both faces. The size of rail and stile as per IS-1003 (Pt-I) Kiln seasoned and chemicallhy pressure treated.(Factory made) complete all as specified and directed. |
| 12 | Supply & fix Aluminium anodised barrel tower bolt 150 mm long of extruded section etc complete all as specified and directed. |
| 13 | Supply and fix MS butt hinges medium weight, cold rolled 125mm size complete all as specified and directed. |
| 14 | Supply and fix MS butt hinges medium weight, cold rolled 100mm size complete all as specified and directed. |
| 15 | Supply & fix Extruded Aluminium anodised alloy handles fabricated type 150mm long complete all as specified and directed. |
| 16 | Supply & fix Extruded Aluminium anodised alloy handles fabricated type 100 mm long complete all as specified and directed. |
| 17 | Supply & fix aluminium alloy, anodised, sliding door bolts 250mm size with hasp, staple (bolt type) and fixing clips of sheets , cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed etc complete all as specified and directed. |
| 18 | Supply & fix sheet glass 4mm thick ordinary quality and glazing with oil putty in squares n.exc 0.50 Sqm in each pane, complete all as specified and directed. |
| 19 | S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 20 | S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples. |
| 21 | Dismantling wall and ceiling boards of any description including cover fillets complete all as specified and directed. |
| 22 | M & L for providing 4mm thick \\"E\\" Board in ceiling with galvanised iron snap frame of 'T' section 24 x 38 x 0.70 mm wall/ceiling angle 25x25x0.35mm thick and hanging with 4mm GI wire all fixed arrangement will be done as per manufacturer instruction incl two coat of oil bound distemper anirected.d one coat of white wash complete all as specified and directed by engr in charge. |
| 23 | S&F aluminium anodised power coated partition fixed/sliding type with frame of size-side and top rail 85 x 44.45 x 1.8mm, bottom and middle rail of size 150 x 44.45 x 1.8mm thick incl screwing of frame glass necessary joints, cleats, glazing clips rubber packing , snap beading , fixed to wall with necessary screws and plug complete all as specified and directed. (rates for 5mm thick tinted glass / aluminium composit panel reqt to be fitted in shutters is incl in the item). |
| 24 | S&F chromium plated curtain rod of medium weight and fixed brackets and decorative end supports etc complete all as specified and directed. |
| 25 | Demolition of cement Concrete(Unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all specified and directed by engr in charge |
| 26 | M&L for 25mm thick PCC type B-0, 1:2:4 (12.5mm graded aggregate) s in sub-base, sub-floors, pavings etc. complete all as specified and directed. |
| 27 | M&L for Non - skid coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed of CM 1:4 complete all as specified and directed |
| 28 | M&L for Non - skid coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering with CM 1:4 on fair faces of brick work or concrete surfaces as in skirting all as specified. |
| 29 | M&L for machine cut kota stone slab (Single Piece in tread) as in flooring 20 to25 mm thick in floor including screed bed 15mm thick or bedding layer for laying floor finishes CM 1:4 etc set and jointed in neat cement slurry and jointed with grey cement slurry mixed pigment to match shade of slab incl rubbing and polishing complete all as specified . |
| 30 | M&L for machine cut kota stone slab (Single Piece) as in flooring 20 to25 mm thick riser of steps , skirting, dado and pillar laid over and including 10mm thick rendering in CM 1:4 complete all as specified and directed |
| 31 | Dismantling floor, hearth or wall tiling including cement mortar bedding( but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 32 | M&L Glazed coloured ceramic tiles in vertical surfaces 350 x 250 x 7mm thick set joint in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer in cement mortar 1:3 10mm thick for laying dado/skirting tiles etc complete all as specified and directed. |
| 33 | Demolition of Brickwork or stone/ boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles |
| 34 | M&L PCC 1:3:6 type C1 as in block masonry with solid blocks exc 10 cm in width and set in CM 1:6. complete all specified and directed. |
| 35 | M&L rendering 10 mm thick on fair faces of brick work/ surfaces in cement mortar (1:6) finished even and fair without using extra cement complete all as specified and directed. |
| 36 | M&L application of distemper oil emusion two coats over 1.5 mm thick wall care putty including preparation of new surfaces complete all as specified and directed. |
| 37 | Dismantling Timber scantling with framed work in fillets, rails, posts, rafters, purlins, etc. under 40 sq cm in section , in any position all as specified and directed. |
| 38 | M& L for cleansawn Second class hard-wood scantlings with framed work complete all as specified and directed. |
| 39 | Supply and fixed 6 mm thick plywood , graded BWR, type BB fixed with nails to timber frame work fixed to ceiling surface etc complete all as specified and directed. |
| 40 | Supply and fixed 4 mm thick plywood , graded BWR, type BB fixed with nails to timber frame work fixed to ceiling surface etc complete all as specified and directed. |
| 41 | Material and labour for new plywood and wood based material surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 42 | Material and labour for preparation of old steel surfaces of any description not otherwise described over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed. |
| 43 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for including removing rubbish off the premises complete all as specified and directed. |
| 44 | M&L for 75mm thick PCC type C-2, 1:3:6 (using 40mm graded stone agg) as in plinth protection complete all as specified and directed. |
| 45 | Taking down cement plaster on brick, concrete block wall or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc. |
| 46 | M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces with CM 1:4 complete all as specified. |
| 47 | M&L for preparing plastered or unplasterd newly surface of any description with three coat of white wash on walls surfaces. |
| 48 | M&L for preparing plastered or unplasterd old surface of any description with two coat of white wash on walls surfaces. |
| 49 | M&L for preparing and applying two coat of synthetic enamel over a priming coat on new zinc (or galvanised ) surfaces to receive painting, by coating with mordant solution including washing and cleaning etc. of any description, not otherwise described, over 10 cm width or girth complete all as specified and directed. |
| 50 | M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggragate as in subbase 40 mm thick complete all specified and directed by engr in charge. |
| 51 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 with WPC 3% by weight of cement finished even and smooth without using extra cement completed all as specified and directedNote:-WPC will be measured and paid separately |
| 52 | Supply only integrated water proofing compound |
| 53 | M&L for preparation of Newly plastered surfaces of walls and applying two coats of oil bound distemper,over a coat of primer complete all as specified |
| 54 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm on walls and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces |
| 55 | Material & labour for 2nd class hard wood plain fillets, square, rectangular or triangular in section, wrought, secured with nails having sectional area exc. 3 sqcm and n.exc 6 sqcm, complete all as specified and directed |
| 56 | Dismantling Timber scantling 40 sq cm and over in section , in any position all as specified and directed. |
| 57 | M&F for providing PCC Type B1 1:2:4 using 20mm stone aggregate, cement concrete as roof kerbs or mud stops rounded or chamfered on edges as in coping complete all as specified and directed |
| 58 | Material and labour for providing cement concrete 1:4:8 type D2 75 mm thick (using 40mm graded aggregate ) as in sub base all as specified. |
| 59 | Supply, installing, testing and commissioning, factory made and tested ,CPRI type tested LT feeder pillar , outdoor type floor mounted , suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and LT panel shall bemounted on angular frame work of 50x50x5mm thick angle iron base frame, minimum 60 cm hight and fixed with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement and consisting of the following all as specified including taking out old feeder pillar and taking out LT cable from loop for connecting in new panel and necessary excavation etc and consisting of the following |
| 60 | (a) Aluminium bus bar four Nos 300 Amps each ,fixed on epoxy insulated with panel fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 04 Nos Incoming:-(b) MCCB, 04 Pole, 125 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%) Outgoing:- (c) MCCB, 03 Pole, 63 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 04 No (Ics=Icu=100%) (d) MCB SPN 32 AMP - 03 Nos (e) MCB TPN 32 AMP - 03 Nos |
| 61 | (f) Digital type volt meter 0-500 volt with selector switch with HRC fuses/ MCBs - 1Set. (g) Digital type ammeter meter 400 Amp with selector switch with HRC fuses/ MCBs - 1Set. (h) LED phase indication lamps R,Y,B LED type with 3 Nos of 2A HRC Fuses – 1 set:- (i) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's/SDFU. (j) Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 mm thick in foundation, brick work in CM 1:6 with sub class B old sized bricks, renderung 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 50cm above the nearest ground level. Note :- Panel drawings & make of MCCB will be submitted by contractor for approval from Accepting Officer before ordering the panel |
| 62 | Supply & Lay XLPE insulated screened PVC bedded,galvanized steel strip or wire armored, electric power cables (heavy duty) 1100V grade with stranded aluminium conductor of size 70 Sq mm 3½ core complete all as specified and directed |
| 63 | Supply & Lay XLPE insulated screened PVC bedded,galvanized steel strip or wire armored, electric power cables (heavy duty) 1100V grade with stranded aluminium conductor of size 25 Sq mm 4 core complete all as specified and directed |
| 64 | Supply & Lay XLPE insulated screened PVC bedded,galvanized steel strip or wire armored, electric power cables (heavy duty) 1100V grade with stranded aluminium conductor of size 16 Sq mm 2 core complete all as specified and directed |
| 65 | Supply & Lay XLPE insulated screened PVC bedded,galvanized steel strip or wire armored, electric power cables (heavy duty) 1100V grade with stranded aluminium conductor of size 10 Sq mm 2 core complete all as specified and directed |
| 66 | S&F in distribution board vertical type TPN 415 Volt for fixing 4 pole MCCB, double door IP 43 protection, 4 way with copper bus bars, neutral links , earth link, earthing studs, blanking plates, interconnection between incomer MCCB and bus bar duly prewired fixed flush to wall / other surface complete all as specified and as directed. |
| 67 | S & F in MCCB, 04 Pole, capacity 63/100 Amps with ultimate breaking capacity 16 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%) in the existing panel with suitable connecting copper terminals at site complete all specified and directed. |
| 68 | S&F MCB SPN having braking capacity 10KA, 32 Amps, 240 V complete all as specified and directed. |
| 69 | S&F MCB SP having braking capacity 10KA, 6 to 32 Amps, 240 V complete all as specified and directed. |
| 70 | Excavation in trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out complete all as specified and as directed. |
| 71 | Returning filling in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and as directed. |
| 72 | Removing excavated soils to a distance n.exc. 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed. |
| 73 | M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particals in trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. Note:- The total thickness of sand shall be measured 18 cm after punning. |
| 74 | Supply and laying un-reinforced precast.concrete cable protection cover of class LV, type-1, flat size 250mm x 150mm x 40 mm, local made super quality complete all as specified and directed. |
| 75 | M & L for road cutting incl necessary excavation 45 cm wide and 90 cm in depth as in trenches in any type of soils/rock for laying LT UG cable through pipe after laying /through the cable trenches will be filling top with M&L PCC 1:3:6 type C-1 using 20 mm grdaeds stone aggregates from top over 15 cm thick hard good of broken boulders , 63 mm gauge over 15 cm bolders 100 mm dia over filled and rammed earth to make good the disburbed surface etc complete all as specified and directed. |
| 76 | Supply and laying galvanised tube light grade ISI marked of size 50 mm dia incl all fittings in trenches/fixed on pole/wall/floor or laid in position complete all as specified and directed. |
| 77 | Supply and laying galvanised tube light grade ISI marked of size 40 mm dia incl all fittings in trenches/fixed on pole/wall/floor or laid in position complete all as specified and directed. |
| 78 | M&L for earthing complete with galvanised steel earth plate electrode 60x60cmx6 mm thick burried directly in ground ( earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 3 of SSR Part-I 2009 connected all as specified or indicated and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil, funnel, PCC chamber ( 1 : 3 : 6) type C1, RCC pit cover , charcol, salt including provision of earth lead protected by 50 mm dia light grade GI pipe and 25 mm dia medium grade GI Pipe for watering complete all as specified and directed. |
| 79 | M&L Steel tubular swaged poles(Swanneck type) complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 metres long) complete all as specified and directed. |
| 80 | M & L for PCC 1:4:8 type D2(using 40 mm stone agg) as in foundation,filling and mass concrete complete all as specified and directed. |
| 81 | M & L for PCC 1:3:6 type C-2 ( using 40 mm stone agg) as in foundation ,filling and mass concrete complete all as specified and directed. |
| 82 | M&L for PCC (1:2:4) type B-1 using 20mm grade stone aggregate as coping for new pole including necessary form work and finishing fair and even using extra cement |
| 83 | S & F PVC water proof junction box of size 205 x 255 x 112mm duly powder coated in side & out side complete incl MCBs SP of 6 Amp with Aluminium bus bar of rated 63 Amp. Fixed on porcelain support with hinged cover & locking arrangment for single phase and neutral and 2x2.50 Sq mm copper conductor PVC wire for making connection from connection box to street light fitting connector fixed to electric pole by means of clamps of MS flat iron of size 25 x6 mm with bolts, nuts all as specified and directed. |
| 84 | M&L for replacement of new generation energy saving and environmental friendly long life LED street light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 35 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including taking down of old unserviceable street light any type/any capacity as specified and directed. |
| 85 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, two single core cable flat or circular of size 4 Sqmm complete |
| 86 | Material & Labour for Point/fan wiring with 1.5 sq mm (nominal area), PVC insulated unsheathed (FRLSH), 1100 volts grade, multi-stranded copper conductor, in and including PVC casing capping of adequate size with all fittings and accessories including PVC boxes for housing the switches ( Make of box Prestoplast,Prestoteak), including PVC insulated and unsheathed (FRLSH)single core multi-stranded copper conductor cable of size 1.5 sq mm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed. |
| 87 | All as per item No. 84 here in before One 3 pin socket outlet, 6 Amps on the same board with other switches, with cables 1.5sq. mm size |
| 88 | All as per item No. 84 here in before but for one 3 pin socket outlet 6 Amps three pin controlled by one switch on independent board complete all as specified directed. |
| 89 | All as per item No. 84 here in before but for one 5 pin socket outlet 16 Amp and 6 Amp Multipurpose independent using 2.5 Sqmm copper conductor cable (multi-strand) PVC insulated and unsheathed cable and 2.5 sqmm copper (multistrand) PVC insulated and unsheathed earth wire complete all as specified. |
| 90 | M&L for in replacement of Point wiring with 2.5 sq mm (nominal area), PVC insulated unsheathed (FRLSH), 1100 volts grade, multi-stranded copper conductor, in and including PVC pipe of adequate size with all fittings and accessories) including PVC insulated and unsheathed (FRLSH)single core multi-stranded copper conductor cable of size 2.5 sq mm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed. |
| 91 | S&F Socket outlet 2 in 1, 3 pin, 5 amp flush type |
| 92 | S&F Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type |
| 93 | Supply & fixing switch piano flush type (ISI marked), single pole, one way 15 Amp, 240 Volts complete all as specified & directed. |
| 94 | Supply & fixing switch piano flush type (ISI marked), single pole, one way 5 Amp, 240 Volts complete all as specified & directed. |
| 95 | Supply and fixing ceiling rose, surface bakelite, 65mm x 50mm , two to three terminals complete all as specified & directed. |
| 96 | S&F in replacement of LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified & directed. |
| 97 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & directed. |
| 98 | Supply and fixing LED light fitting 1 x 20 Watt 220 volt AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of size from ceiling rose complete all as directed. |
| 99 | S&F LED bulkhead fitting 10 watt (Endura Ruby) with all accessories and including connenting up with three core twisted with flexible copper conductor cable with suitable size of 230 volts , 50 hz complete all as spicified and directed. |
| 100 | Supply and fixing LED light fitting 1 x 20 Watt 220 volt AC decorative box type with driver, three core flexible copper conductor cable of size from ceiling rose complete all as directed. |
| 101 | S&F of new generation energy saving and environmental friendly long life LED building security light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 35 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including twisted 3 core copper cable of size 1.5 Sqmm dia for connecting phase, neutral and earth from ceiling rose to light length as required at site,GI bracket 32 mm dia pipe and 02 numbersclmaps, all fixing arrangements such as fastners, bilts, nuts washers etc all as specified and directed. |
| 102 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 30mm sweep with, blades, and frame and louvers |
| 103 | Supply and fix electric water heater(Geyser), storage type steel body with copper inner tank and heating element up to 2 KW capacity 25 litre, BEE 5 star rated adjustable temprature setting 0-90 degree C complete with accessories such as safety wall, thermostate, NRV indication lamps, inlet outlet connections,air vent connections, connection pieces including all fixing arrangements such as fastners, bilts, nuts washers etc including making good disturbed wall surfaces matching with the existing surface and finishing complete all as specified and directed by Engr in charge |
| 104 | S&F Stop valves, cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe of size 15 mm. |
| 105 | S&F 15mm Bib tap cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified & as directed by engr-in-charge. |
| 106 | M & L for PVC connections 15mm size with PTMT nuts of length 450mm for hot and cold water connection complete |
| 107 | S & F incl leakage testing galvanised steel water tubing medium grade 15 mm dia bore with all fittings such as bends, elbow, socket, reducer etc, laid under floor / trenches all as specified & directed. |
| 108 | S&F wire for circuit/sub main wiring with 1100 volts grade double core PVC insulated and unsheathed cable with multistranded copper conductor 6 Sqmm, on surface or recessed or drawn in PVC casing capping/PVC Pipe along with 6 Sqmm single core copper conductor multi stranded cable as earth continuity conductor complete all as specified and as directed.(Note: One RM PVC casing capping/PVC conduit ,one run of 6 sqmm earth wire and 2 Run of 6 sqmm cable shall be measured as one run.) |
| 109 | Supply and fix sheet metal enclosures for DBs Double Door when MCBs to be used 230 volts 8 way 200 Amp rated busbar single pole and neutral fixed on wall duly grouted in solid block wall or on wooden board. |
| 110 | Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15 mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge. |
| 111 | Taking down point wiring carefully copper/ aluminum (light,fan, socket or power) complete (fittings such as switches ceiling rose, pendents, regulators, sockets etc) |
| 112 | Taking down main switches, DBs alongwith existing board and removing the same from the site and making good the disturb surfaces / Portion of the wall etc all specified and directed by EIC. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender