Defence Government Departments Closing in 5 days TDR #56556670

Tender For Carrying Out Preventive Maintainence Of 33 Kv/11 Kv Sub Station At Humhama C Us Under Ftr Hq Bsf Kashmir

Issued by Government Departments · Budgam, Jammu and Kashmir
Tender Value
4.98 Lakhs
Estimated cost
Bid Submission
28 Jul 2026
5 days left
EMD
9979
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Budgam → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Carrying Out Preventive Maintainence Of 33 Kv/11 Kv Sub Station At Humhama C Us Under Ftr Hq Bsf Kashmir

BOQ

Name of Work:- Carrying out preventive maintainence of 33 KV/11 KV Sub Station at Humhama c us under FTR HQ BSF Kashmir
Sl. No. Item Description
1Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3X1.5 Sqmm
2Providing and fixing 3 phase LED Digital Ammeter accuracy class 0.5,CT/PT site programmable make L&T/Havells or equivalent.
3Providing and fixing 3 phase LED Digital Voltmeter accuracy class 0.5,CT/PT site programmable make L&T/Havells or equivalent.
4Providing and fixing CT coil (Current transformer) 800/5 Amp make L&T/Havells or equivalent.
5SITC of potential transformer (PT),Nominal System Voltage: (11 kV/110V,Highest System Voltage: 12 kV System Frequency: 50Hz,Lightning Impulse Withstand Voltage: 75 kVp,Rated Voltage Factor:1.2 Continuous, 1.5 for 30 seconds Insulation Class: Class A or Class E (Standard epoxy resin / oil),ACC class:0.5,Burden:100 VA,Type: Phase to earth,Type of Installation: indoor (oil-immersed or resin-cast) or Indoor (resin-cast/dry type)Core Material: High-grade, non-aging cold rolled grain oriented (CRGO) silicon steelTerminal Material: Tinned electrolytic copper (Primary), nickel-plated brass (Secondary)Creepage Distance: Min 25mm/kV (for outdoor porcelain housings)Electric Field,Siemens/L&T/ABB/Schneider Electric
6SITC of Bush type insulator ,rating:11 KV,Shape-Cylindrical,Materials: Usually premium porcelain (ceramic) for weather/heat resistance or epoxy resin for higher mechanical strength and compact size of VCB panels electric filed
7Providing and Fixing of control Plastic Corded Electric Led Panel Indicator Light (Set Of Red, Green, Blue, Yellow),TypeCluster LED (Light Emitting Diode) or Filament,Operating Voltage30V DC, 110V DC, or 230V AC/DC (auxiliary supply)
8Dehydration of transformer oil in the existing transformer at site and , moisture removal from transformer oil,and maintain the viscosity of oil scope .Necessary pump and barrel driving execution of work shall be part of contractor if oil drain out necessary. Transformer oil dehydration is based on use of synthetic adsorbents ,additionally allows moisture to diffuse out of the paper into the oil. and submit thetest report of transformers after conducting of its dielectric strength, viscosity, thermal conductivity, chemical stability ,BDV value etc as requied.
9Supplying and topup of Transformer Oil as per IS 335 of density 0.8279 gm/cubic cm at 27°C up to the permissible quantity .and oil shall have the property of high dielectric strength,low thermal conductivity, and high chemical stability,high BDV value and must keep these properties when held at high temperatures for extended periods as per IE rules. Typical specifications are: flash point 140 °C or greater, pour point −40 °C or lower, dielectric breakdown voltage 28 kV (RMS) or greater.ISO viscosity-10,Colour-Water white,Appearance-Clear & ,Kinematic viscosity @ 400C etc as requied.Make-HP,Transol,Servo.
10Setting right and realignment of 03 Nos 33/11 KV G.O Sets/ Isolators including replacment of damaged of damaged grooves and operating handles with insulating sleeves inspecting, cleaning, and lubricating all moving parts and ensuring proper mechanical alignment and function. Key maintenance steps include lubricating bearings, tightening hardware, and verifying padlocking to prevent accidental operation.
11Providing, Fixing, testing and commissioning of 36 V Tripping and closing Coils with complete assembly suitable for main incommer of Electric Field Make.Electric Field,Siemens/ABB/Schneider Electric/Genesis
12Providing, Fixing, testing and commissioning of 36 V master realy with complete assembly suitable for VCB, For Ht Breaker,Voltage.Electric Field,Siemens/ABB/Schneider Electric/Genesis
13Providing, fixing, testing and commissioning of O/C & E/F Relay,Over current protection,1A/5A,50 hzElectric Field,Siemens/ABB/Schneider Electric/Genesis
14Protecting 11 kV panels from rats requires Cable Entry Points: Seal all cable trenches, gland plates, and entry points with Todol Duo-fill Foam Sealant or heavy-duty fire-retardant silicone.Ventilation Louvers: Cover existing ventilation slots and louvers with fine, rigid stainless steel wire mesh (minimum 16-gauge). Ensure the mesh is secured tightly so rats cannot squeeze through or pry at the edges.
15SITC of current transformer (CT) of 11 KV VCB ,CT Ratio 400-200 A/5-5 A,Rated Voltage 11 kV,Accuracy Class 0.5/5P10,Winding Material Copper,Rated Burden 15VA, Insulation Level,12/28/75 kVP,Secondary Current 5 Amp.etc complete as required (Set of three)
16Servicing of 11 KV VCB (Vacuum Circuit Breaker) panel and outdoor isolator switch involves a comprehensive process of cleaning, lubrication, testing, and replacement of parts to ensure safety and optimal performance. Key tasks include cleaning with a contact cleaner, re-greasing mechanical parts, checking contact condition and alignment, testing tripping and closing mechanisms, tightening hardware, and verifying wiring integrity. The service often includes professional overhauling, which can help minimize downtime and extend the panel's life.
17Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56556670
AUTHORITY Government Departments
TENDER VALUE 4.98 Lakhs
LAST DATE 28-07-2026
Authority
Authority Name Border Security Force
Work Description Tender for Carrying Out Preventive Maintainence Of 33 Kv/11 Kv Sub Station At Humhama C Us Under Ftr Hq Bsf Kashmir
Basic Detail
Tender No 263/AC(E)/FTR-KMR/2026-27
Bidding Type Tender
Location
City Budgam
State Jammu and Kashmir
Key Dates
Publish Date 20 Jul 2026
Submission Date 28 Jul 2026
Open Date 29 Jul 2026
Finance
Tender Value 4.98 Lakhs
Tender Fee Ref. Documents
EMD 9979
Exemption Available
Document List
8c224efc-c4ec-4860-82b8-145aa0580fe6.html
BOQ_964846.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Jul 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

8c224efc-c4ec-4860-82b8-145aa0580fe6.html

xls

BOQ_964846.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders