Tender For Arm Of Logistics Support Group Buildings At Nsg C Manesar For The Year 2026-27 (Sh: Civil & Elect Maintenance).

Issued by Government Departments · Gurgaon, Haryana
Tender Value
26.74 Lakhs
Estimated cost
Bid Submission
27 Jul 2026
1 days left
EMD
53482
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gurgaon → Haryana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Arm Of Logistics Support Group Buildings At Nsg C Manesar For The Year 2026-27 (Sh: Civil & Elect Maintenance).

BOQ

Name of Work:- ARM of Logistics Support Group Buildings at NSG C Manesar for the year 2026-27 (SH: Civil & Elect Maintenance).
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
2All kinds of soil.
3Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:
4All kinds of soil
5Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
6Providing and laying in position excluding cement concrete of level: specified grade the cost of centering and shuttering - All work up to plinth
71:1.5:3 (1 Cement: 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
81:5:10 (1 cement : 5 coarse sand (zone-Ill) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
9Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
10Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement:
111:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
12Centering and shuttering including strutting, propping etc. and removal of form for
13Shelves (Cast in situ)
14Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
15Thermo-Mechanically Treated bars of grade Fe-500D or more.
16Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
17Cement mortar 1:6(1 cement : 6 coarse sand)
18Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
19Cement mortar 1:4(1 cement :4 coarse sand)
20Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand).
21Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.
22Granite stone slab of colour black, Cherry/Ruby red
23Area of slab upto 0.50 sqnn
24Area of slab over 0.50 sqm
25Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.
26Granite Stone of approved shade
27Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :
28250x16 mm
29Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
30150x10 mm
31100x10 mm
32Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
33100 mm
34Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
35Providing and fixing to existing door frames.
3630 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/ Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table 3 of IS: 14856, complete as per direction of Engineer-in-charge.
37Providing and laying Vitrified tiles in floor in diferent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
38Glazed Vitrified tiles Matt/Antiskid finish of size
39Size of Tile 600 x 600 mm
40Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
41110 mm diameter
42Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion.
43Coupler
44110 mm
45Single tee with door
46110x110x110 mm
47Single tee without door
48110x110x110 mm
49Bend 87.5°
50110 mm bend
5112 mm cement plaster of mix:
521:6 (1 cement: 6 coarse sand)
5315 mm cement plaster on rough side of single or half brick wall of mix:
541:6(1 cement: 6 coarse sand)
55Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:
56New work (Two or more coats applied @ 1.43 Itr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
57Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:
58One or more coats on old work
59Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and of required shade and colour complete to give and even shade.
60Old work (one or more coats)
61Finishing walls with Acrylic Smooth exterior paint of required shade:
62Old work (Two or more coat applied @ 1.67 Itr/ 10 sqm) on existing cement paint surface
63Old work (One or more coat applied @0.90 Itr/10 sqm).
64Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
65With cement mortar 1:4 (1cement: 4 coarse sand)
66Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:
67Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm)
68Dismantling W.C. Pan of all sizes including disposal of dismantled materials including malba all complete as per directions of Engineer-in-Charge.
69Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
70Nominal concrete 1:4:8 or leaner mix (including equivalent design mix)
71Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
72In cement mortar
73Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
74Of area 3 sq. metres and below
75Demolishing mud phaska in terracing and disposal of material within 50 metres lead.
76Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead :
77100 mm dia pipe
78Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
79Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
80W.C. pan with ISI marked white solid plastic seat and lid
81Providing and fixing white vitreous china water closet squatting pan (Indian type) :
82Orissa pattern W.C. pan of size 580x440 mm
83Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.
8410 litre capacity - White
85Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
86Flexible pipe
8732 mm dia
88Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
89Rectangular shape 1500x450 mm
90Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
91600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
92Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
9320 mm nominal dia Pipes
9425 mm nominal dia Pipes
95Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work - Exposed on wall
9620 mm dia nominal bore
9725 mm dia nominal bore
98Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
9925 mm nominal bore
10020 mm nominal bore
10132 mm nominal bore.
102Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
10320 mm nominal bore
10425 mm nominal bore
105Providing and fixing uplasticised PVC connection pipe with brass unions :
10645 cm length
10715 mm nominal bore
108Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :
109100 mm diameter
110Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
11115 mm nominal bore
112Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
11315 mm nominal bore
114Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
11515 mm nominal bore
116Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
11715 mm nominal bore
118Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge.
119Providing and fixing PTMT bib cock of approved quality and colour.
12015 mm nominal bore, 122 mm long, weighing not less than 99 gms
121Providing and fixing PTMT grating of approved quality and colour.
122Circular type
123100 mm nominal dia
124125 mm nominal dia with 25 mm waste hole
125Making hole up to 20x20 cm and embedding pipes up to 150 mm diameter in masonry and filling with cement concrete 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) including disposal of malba.
126Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
127150 mm diameter
128Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :
129150 mm diameter S.W. pipe
130Extra for depth for manholes :
131Size 90x80 cm
132With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
133Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality
134Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) :
135Rectangular manhole 90x80 cm with rectangular cover 600 x 450 mm of grade LD - 2.5
136Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
137For fixed portion
138Powder coated aluminium (minimum thickness of powder coating 50 micron)
139For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
140Powder coated aluminium (minimum thickness of powder coating 50 micron)
141Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
142With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
143Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
144Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”:
145With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
146Providing and fixing Ist quality ceramic glazed wall tiles(not less than 600x300mm) conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
147Correction factor @ 0.973 = 1924759.69 x 0.973= 1872791.17 - 1927759.69 = (-) 51,968.51
148Cost Index @ 4.03% = 1872791.17 x 4.03% = 75,473.48
149Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, and C.I. trap for standard urinal with vent arm with operating and other couplings in C.P.brass: 50 mm dia other couplings in C.P. brass, including cutting and making good the walls and floors wherever required.
150Providing and fixing white vitreous china table top/counter top wash basin In White Matt of Size not less than: 500x400x140 mm, of approved make with CP pillar cock and 32mm CP Brass Waste of standard pattern including making all connection , Shape - Rectangular as per direction of engineer in charge all complete
151Providing and fixing CP Health Faucet with 8mm Dia, 1.0 Meter Long Spirochrome flex tube & Wall Hook of approved make and all complete, as per direction of engineer in charge
152Credit for dismantled material received from site of work which will be handed over to contractor as per direction of Engineer-in-charge.Dismantled CI pipe
153Credit for dismantled material received from site of work which will be handed over to contractor as per direction of Engineer-in-charge.Dismantled old steel
154Electrical
155Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc as required.
156Group B
157Group C
158Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required.
159Wiring for light/ power plug with 4X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 2 Nos 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required.
160Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
1612 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
162Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
163Group B
164Group C
165Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
1663 x 1.5 sq. mm
1673 x 4 sq. mm
168Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
16920 mm
17025 mm
171Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
172Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.
1731 or 2 Module (75mmX75mm)
1743 Module (100mmX75mm)
175Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
176Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
177Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
178Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
179Upto 450 mm sweep
180Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
181Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
1828 way, Double door
183Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
184Single pole
185Single pole and neutral
186Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
187Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR /HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
1881200mm, service value ≥ 5.1 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
189LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS/HFFR , PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm
19018-22watt
191LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation ColorMatching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS/HFFR ,
192PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 36 watt
193LED Down lighter (SMD Type) (System lumen Unit Rate efficacy ≥ 105 < 120 lm/Watt). Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round / square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) Powder coated die cast /Extruded aluminium Body including trim .
19418watt
195Providing and fixing a metallic louvred shutter suitable for following sizes exhaust fan, the louvres should be able to open when the fan is on and close when the fan is turned off, on the existing opening on the wall, etc., as required.
196300 mm
197450 mm
198Supplying and fixing Plug top following rating including connection etc. as required.
19916 A 3/6 Pin Plug top
2006 A 3/6 Pin Plug Top
201Supply, installation, testing, and commissioning of LED bulkhead fittings with IP 66 ingress protection, with a minimum system lumen output of 1000 lumens and a minimum system luminous efficacy of 100 lm/W, made of aluminium housing having a colour temperature of 5500K–6500 K, average life L70B50: 50000 hours, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, diffuser, electronic driver, etc. as required directly on the wall, including connections, etc. as required
202Supplying, installation, testing, and commissioning of 10 to 11 Watt, 0.6 Metre (nominal size) LED Bollard Light fitting complete with LED module, electronic driver, diffuser, and all other accessories, minimum system luminous efficacy of 80 lm/W, the bollard housing should be made up of metallic pipe duly powder coated with the mounting flange at the bottom,
203including providing 3 nos M10 foundation bolts, two numbers 32 mm. dia PVC pipe for cable entry (from the bottom of the foundation to the top of the foundation for cable entry), and providing the foundation of Cement concrete 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size ) of size 0.3-metre dia and 750 mm height (250mm above ground and 500 mm below ground) including excavation as required and complete with connections, lugs, terminals, connectors for the connection of cable and wires in the fitting etc., complete as required. (Make Havells /Philips /Wipro as per sample approved by Engineer -in - Charge)
204Supplying and laying of one number PVC/XLPE insulated and PVC sheathed/XLPE aluminium armoured conductor power cable 1.1 KV grade of following size in the existing RCC/ HUME/ STONEWARE/ METAL/ DWC pipe as required.
2052 X 16 Sq.mm
2063.5 X 35 Sq.mm
2073.5 X 120 Sq.mm
208Supplying and laying of one number PVC/XLPE insulated and PVC sheathed/XLPE aluminium armoured conductor power cable 1.1 KV grade of following size in Masonry Open Duct Loose/loop/in panel etc. complete etc as required.
2092 X 16 Sq.mm
2103.5 X 35 Sq.mm
2113.5 X 120 Sq.mm
212Supply, installation, testing and commissioning of 45 watts LED-based post top luminaires, IP 65, with Die-cast aluminium spigot housing and complete with diffuser, LED module, electronic driver and all other accessories, having minimum system luminous efficacy of 95 lm/W, on existing street light pole/gate including connection etc. as required. Make :CORAL (Opal) or RUBY (Clear) of Havells similar in Philips / Havells/ Wipro/ Bajaj
213Supply and drawing of 3 x 1.5 sq mm PVC insulated, FRLS PVC sheathed copper conductor multi core flexible cable into the existing street light pole, making connections at one end with the street light fitting fixed to the top of the pole and the other end with the control gearbox, including drawing out the burnt-out wires from the pole if required, etc. as required.
214Providingand installation of GI pipes class B marked with IS: 1239 in 3 m length, complete in all respects to the satisfaction of Engineer-in- Charge. (Make : ISI marked B class Jindal Hisar / Tata / Prakash Surya / Swastik / Zenith maked G.I. pipe)
21565mm Dia
216Providing, fixing and making suitable arrangement on existing pole for fixing of post top LED light with GI accessories such as Reducer,GI Nipple of suitable length etc as required including dismentling of existing arrangement.( All Material should be ISI Marked)
217Providing and making steel pole collar with cement concrete (1 cement : 3 coarse sand : 6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curingetc as required. (volume of pole/ pipe not to be deducted).
218Dismantling of the existing switch accessories like switches, sockets, and MCBs, etc., as required.
219Dismantling of the existing ceiling rose, holder, and wall bracket and depositing the same with the listing of materials in the store.
220Dismantling of existing fluorescent fitting from ceiling/ wall including making good the damage to match the adjacent surface, etc., as required.
221Dismantling of the existing ceiling fan/ exhaust fan of any size installed in the building and depositing it in the MMC store.
222Dismantling of the existing recessed vertical type or horizontal type TPN MCB distribution board of any size along with MCBs and other accessories, including making good the damage to match the adjacent surface, etc., as required.
223Dismantling of the existing recessed SPN MCB distribution board of any size along with MCBs and other accessories, including making good the damage to match the adjacent surface, etc., as required.
224Dismantling of the existing recessed switch board of light points/power points, power/light plug points/socket outlet metal boxes of any size, along with phenolic laminated sheet, switches, sockets, etc., making good the damage to match the adjacent surface, etc., as required.
225Dismantling wires from the following sizes, existing circuit/submain/power wiring conduits, complete as required. The length of the conduit from which the wires are removed will be measured for payment purposes, irrespective of the number of wires in it.Above 25 mm conduits.
226Dismantling wires from the following sizes, existing circuit/submain/power wiring conduits, complete as required. The length of the conduit from which the wires are removed will be measured for payment purposes, irrespective of the number of wires in it.Up to 25 mm conduit.
227Less credit for the unserviciable items dismantled items during execution of the work.
228Assorted MCB TP AND TP&N & OTHER SWITCHGEAR
229Assorted PIANO Type Switches
230Assorted PIANO Type Sockets
231Assorted Bell push/PIANO Type
232Assorted Call bell buzzer single phase
233Assorted Brass batten/ angle holder/Brass Bracket
234Assorted Fan regulator/resistance type
235Assorted Telephone Socket outlet
236Assorted T.V. Socket outlet
237Assorted Capacitor, 3.15/2.50/2.25 mfd
238Assorted 1200/1400 mm sweep ceiling Fan with blades
239Assorted Fresh Air FAN 200/250
240Assorted Exhaust fan 300/380/450
241Assorted Wall Bracket Fittings
242Assorted fluorescent Light Fittings
243Assorted Bulk Head Fittings
244less credit for the dismantled Copper wire wires from light points/ circuit/ submain/power circuit wiring,.
245less credit for the dismantled aluminium wire wires from light points/ circuit/ submain/power circuit wiring,.
246Assorted metal switch box.
247Assorted MCB DB SPN with out MCBs
248Assorted MCB DB TPN with out MCBs
249Assorted MCB SP
250Assorted MCB DP
251Assorted MCB TP AND TP&N Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56556088
AUTHORITY Government Departments
TENDER VALUE 26.74 Lakhs
LAST DATE 27-07-2026
Authority
Authority Name National Security Guard
Work Description Tender for Arm Of Logistics Support Group Buildings At Nsg C Manesar For The Year 2026-27 (Sh: Civil & Elect Maintenance).
Basic Detail
Tender No 26/CS/2026-27/NSG
Bidding Type Tender
Location
City Gurgaon
State Haryana
Key Dates
Publish Date 20 Jul 2026
Submission Date 27 Jul 2026
Open Date 28 Jul 2026
Finance
Tender Value 26.74 Lakhs
Tender Fee Ref. Documents
EMD 53482
Exemption Not Available
Document List
BOQ_964829.xls
e9cad006-32c7-4794-ba34-94c28122b5c2.html
Tendernotice_1.pdf
Tendernotice_2 (1).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Jul 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_964829.xls

html

e9cad006-32c7-4794-ba34-94c28122b5c2.html

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2 (1).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders