Tender For Arm Of 13 Srg Buildings At Nsg C Manesar For The Year 2026-27 (Sh: Civil & Electrical Maintenance).
Tender Value
25.93 Lakhs
Estimated cost
Bid Submission
27 Jul 2026
2 days left
EMD
51866
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gurgaon → Haryana
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Arm Of 13 Srg Buildings At Nsg C Manesar For The Year 2026-27 (Sh: Civil & Electrical Maintenance).
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 2 | For thickness of tiles 10mm to 25 mm |
| 3 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead |
| 4 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge. |
| 5 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer in - charge. |
| 6 | Nominal concrete 1 :4:8 or leaner mix (including equivalent design mix) |
| 7 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 8 | Of area 3 sq. metres and below |
| 9 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 10 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 11 | (i)Single socketed pipes. ..110 mm diameter |
| 12 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion. (For Drainage / Sewer Line )...... |
| 13 | Bend 87.5° |
| 14 | 110 mm bend |
| 15 | Providing and laying in position excluding cement concrete of level: specified grade the cost of centering and shuttering - All work up to plinth |
| 16 | 1:5:10 (1 cement : 5 coarse sand (zone-Ill) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 17 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 18 | 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 19 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 20 | 15 mm nominal bore |
| 21 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 22 | 15 mm nominal bore |
| 23 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : |
| 24 | 150 mm diameter |
| 25 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 26 | 15 mm nominal bore |
| 27 | Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge. |
| 28 | Providing and fixing PTMT grating of approved quality and colour. |
| 29 | Circular type |
| 30 | 125 mm nominal dia with 25 mm waste hole |
| 31 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 32 | 45 cm length |
| 33 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 34 | Semi rigid pipe |
| 35 | 40 mm dia |
| 36 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 37 | White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps |
| 38 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 39 | W.C. pan with ISI marked white solid plastic seat and lid |
| 40 | Providing and fixing CP Health Faucet (ABS Body) with 8mm Dia, 1.0 Meter Long Spirochrome flex tube & Wall Hook of make Euronics, hindware, Parryware, all complete, as per direction of engineer in charge …. |
| 41 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : |
| 42 | Of area 3 sq. metres and below |
| 43 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 , of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 44 | Size of Tile 600x600 mm |
| 45 | Providing and laying rectified matt finish Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make in all colours, shades and pattern matching with bathroom wall tile concepts, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 46 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. ... |
| 47 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. |
| 48 | 20 mm nominal dia Pipes |
| 49 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 50 | With cement mortar 1:4 (1cement: 4 coarse sand) |
| 51 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 52 | Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
| 53 | Providing and fixing Fiber Glass Reinforced plastic (FRP)Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs.The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. |
| 54 | Providing and fixing to existing door frames. |
| 55 | 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin,moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/ Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table 3 of IS:14856, complete as per direction of Engineer-in-charge. |
| 56 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 57 | 250x16 mm |
| 58 | Providing and fixing aluminium tower bolts, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour orshade, with necessary screws etc. complete : |
| 59 | 250x10 mm |
| 60 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 61 | 150x10 mm --Dining Hall |
| 62 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 63 | 125 mm |
| 64 | Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: |
| 65 | 125x75x4 mm -ACS Toilet + Dining Hall window |
| 66 | Providing and fixing aluminium work for doors, windows,ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size,including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 67 | For fixed portion |
| 68 | Providing and fixing aluminium work for doors, windows,ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size,including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 69 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). |
| 70 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 71 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 72 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 73 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : |
| 74 | 100 mm inlet and 100 mm outlet |
| 75 | Sand cast iron S&S as per IS: 3989. |
| 76 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 77 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer,over the plastered wall surface to prepare the surface even and smooth complete. |
| 78 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour |
| 79 | Old work (one or more coats) |
| 80 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
| 81 | Two coats. |
| 82 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 83 | One or more coats on old work. |
| 84 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. |
| 85 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 86 | Of area 3 sq. metres and below |
| 87 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 88 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : |
| 89 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. |
| 90 | With 12 mm mild steel U beading |
| 91 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 92 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 93 | 1:6 (1 cement: 6 fine sand) |
| 94 | Finishing walls with water proofing cement paint of required shade : |
| 95 | New work (Two or more coats applied @ 3.84 kg/10 sqm). |
| 96 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.. |
| 97 | In cement mortar |
| 98 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 99 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 100 | 12 mm cement plaster of mix : |
| 101 | 1:6 (1 cement: 6 fine sand) |
| 102 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. |
| 103 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /seIf tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 104 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 105 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : |
| 106 | With 20 mm diameter round bar |
| 107 | Credit for MS section like angle, tee, flats, grill etc. |
| 108 | Correction factor @ 0.973 = 1920552.52 x 0.973= 1868697.60 - 1920552.52 = (-) 51,854.91 |
| 109 | Cost Index @ 4.03% = 1868697.60 x 4.03% = 75,308.51 |
| 110 | Electrical |
| 111 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/ /HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS / /HFFR PVC insulated copper conductor single core cable etc. as required. |
| 112 | Group A |
| 113 | Group B |
| 114 | Group C |
| 115 | Wiring for twin control light point with 1.5 sq.mm FRLS/ HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/ HFFR PVC insulated copper conductor single core cable etc. as required. |
| 116 | Wiring for light/ power plug with 2X4 sq. mm FRLS/ HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS / HFFR PVC insulated copper conductor single core cable for loop earthing as required. |
| 117 | Wiring for light/ power plug with 4X4 sq. mm FRLS/ HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 Nos 4 sq. mm FRLS/ HFFR PVC insulated copper conductor single core cable for loop earthing as required. |
| 118 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/ HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 119 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 120 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 121 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 122 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 123 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 124 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 125 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 126 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/ HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/ HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. |
| 127 | Group C |
| 128 | Rewiring for twin control light point with 1.5 sq.mm FRLS/ HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/ HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 129 | Supplying and drawing following size of FRLS/ HFFR PVC insulated copper conductor single core cable in the existing surface/ recessed steel/ PVC conduit as required |
| 130 | 1 x 1.5 sq. mm |
| 131 | 2 x 1.5 sq. mm |
| 132 | 3 x 1.5 sq. mm |
| 133 | 4 x 1.5 sq. mm |
| 134 | 5 x 1.5 sq. mm |
| 135 | 6 x 1.5 sq. mm |
| 136 | 9 x 1.5 sq. mm |
| 137 | 1 x 4 sq. mm |
| 138 | 3 x 4 sq. mm |
| 139 | 6 x 4 sq. mm |
| 140 | 3 x 6 sq. mm |
| 141 | 2 x 10 sq. mm + 1 x 6 Sq.mm |
| 142 | Supplying and drawing following pair 0.5 mm dia FRLS/ HFFR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required |
| 143 | 1 Pair |
| 144 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 145 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 146 | 20 mm |
| 147 | 25 mm |
| 148 | 32 mm |
| 149 | 40 mm |
| 150 | 50 mm |
| 151 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 152 | 5/6 A switch |
| 153 | 2 way 5/6 A switch |
| 154 | 15/16 A switch |
| 155 | 3 pin 5/6 A socket outlet |
| 156 | 6 pin 15/16 A socket outlet |
| 157 | Telephone socket outlet |
| 158 | TV antenna socket outlet |
| 159 | Bell push |
| 160 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 161 | 5/6 A switch |
| 162 | 2 way 5/6 A switch |
| 163 | 15/16 A switch |
| 164 | 3 pin 5/6 A socket outlet |
| 165 | 6 pin 15/16 A socket outlet |
| 166 | Telephone socket outlet |
| 167 | TV antenna socket outlet |
| 168 | Bell push |
| 169 | 25 amp switch |
| 170 | Computer Jack ( RJ 45) Cat6 (1 module) |
| 171 | 6 A to 32 A rating, 240 V, , \\"C\\" curve, SP modular MCB |
| 172 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 173 | Supplying and fixing two module stepped type electronic piano fan regulator on the existing phenolic cover plate switch box including connections but excluding cover plate etc. as required. |
| 174 | Supplying and fixing one module stepped type electronic piano fan regulator on the existing phenolic cover plate switch box including connections but excluding cover plate etc. as required. |
| 175 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 176 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 177 | 1 or 2 Module (75mmX75mm) |
| 178 | 3 Module (100mmX75mm) |
| 179 | 4 Module (125mmX75mm |
| 180 | 6 Module (200mmX75mm) |
| 181 | 8 Module (125mmX125mm) |
| 182 | 12 Module (200mmX150mm) |
| 183 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 184 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 185 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 186 | Supplying and fixing Ding Dong Door Bell, suitable for single phase, 230 V, complete as required. |
| 187 | Providing and fixing plain 16/0.20mm (0.50sqmm) twin circular flexible FRLS/ HFFR PVC insulated, PVC sheathed copper conductor cable direct on the wall with PVC clips etc. as required. |
| 188 | Supplying and fixing extra down rod of 10 cm length G.I. pipe ,15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 189 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 190 | Extra for fixing the louvers/ shutters complete with frame for an exhaust fan of all sizes. |
| 191 | Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non- Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy identification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc. complete as required. |
| 192 | 1 run of cable |
| 193 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS/ HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/ HFFR PVC insulated copper conductor single core cable etc. as required. |
| 194 | Group C |
| 195 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. |
| 196 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 16 A modular socket outlet and 16 A/25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 197 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 198 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 199 | 8 way , Double door |
| 200 | 12 way , Double door |
| 201 | 16 way, Double door |
| 202 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 203 | Single pole |
| 204 | Double pole |
| 205 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 206 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 207 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 208 | Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V \\"C\\" curve TP MCB complete with connections, testing and commissioning etc. as required. |
| 209 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. |
| 210 | For 6 way, Double door SPN MCBDB |
| 211 | For 8 way, Double door SPN MCBDB |
| 212 | For 10 way/ 12 way, Double door SPN MCBDB |
| 213 | For 14 way/16 way, Double door SPN MCBDB |
| 214 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 215 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling etc as required. |
| 216 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 217 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise= 75°C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 218 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 219 | Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe and making good the same etc. complete as per direction of Engineer-in-charge |
| 220 | Supplying and fixing an IP66 PVC weatherproof 240V switch box, complete with one 16 A switched socket, on surface or in recess, complete with connections, testing and commissioning etc. as required. |
| 221 | Supplying and fixing two module bell/ chime on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 222 | Supply, installation, testing and commissioning of wall-mounted light fixture complete with B22 base, metal base in Nickel / Brass finishing with diffuser and 9 watts LED blub etc., as required directly on the wall, including connections etc. as required. ( Havells FLORETINE WL 1 LS or similar in Wipro/Philips/Jaquar/LT as approved by the Engineer -in- charge) |
| 223 | Supplying and fixing 3 mm thick phenolic laminated sheet cover on existing switch Box / metal box with Al. Alloy/ cadmium/ zinc plated screws and washers, including cutting the laminated sheet to required shape and size etc., complete as required. |
| 224 | Supply and installation of 200 mm sweep PVC exhaust fan with louver shutter, having a minimum air delivery of 500 CMH and a power consumption not exceeding 30 watts, in the existing opening, including making good the damage, connections, testing, and commissioning, etc., complete as required, with a minimum two-year manufacturer's warranty. (Make: Havells / Crompton/ Orient / Usha / atomberg / Almonard) |
| 225 | Supply and installation of 250 mm sweep PVC exhaust fan with louver shutter, having a minimum air delivery of 750 CMH and a power consumption not exceeding 40 watts, in the existing opening, including making good the damage, connections, testing, and commissioning, etc., complete as required, with a minimum two-year manufacturer's warranty. (Make: Havells / Crompton/ Orient / Usha / atomberg / Almonard) |
| 226 | Supplying and installation of 300 mm sweep, 1400 RPM, heavy-duty, single-phase, metallic exhaust fan conforming to IS:2312-1967 in the existing opening, including making good the damage, including connections, earthing, testing, and commissioning, etc., complete as required, with a minimum two-year manufacturer’s warranty (Havells / Crompton / Orient / Usha / Almonard). |
| 227 | Making holes of the required size and shape in a brick masonry wall for installation of the following size exhaust fan, including making good the wall by plastering and finishing with the matching surface, etc., complete as per the direction of the engineer-in-charge. |
| 228 | 200 mm sweep. |
| 229 | 250 mm sweep. |
| 230 | Supply and fixing of 12 mm thick BWP/marine grade plywood wood board having a circular /rectangular hole to suit the sie of exhaust fan upto 380 mm on wall /window for etc as required including the cost of making hole, nuts and bolts, etc. as required. |
| 231 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F. ≥ 0.95, IP20, CRI ≥ 80 , Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. |
| 232 | Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) |
| 233 | 18- 22 watt |
| 234 | 40 watt |
| 235 | Supply, installation, testing, and commissioning of integrated LED Batten luminaire, with a minimum system lumen output of 1000 lumen and with a minimum system luminous efficacy of 100 lm/W, made of aluminium housing having a colour temperature 5500K - 6500 K, Average life L70B50: 50000 hours, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, electronic driver, diffuser, directly on the ceiling/wall, including connections, earthing, etc. as required. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. |
| 236 | Supply, installation, testing, and commissioning of LED bulkhead fittings with IP 66 ingress protection, with a minimum system lumen output of 1000 lumens and a minimum system luminous efficacy of 100 lm/W, made of aluminium housing having a colour temperature of 5500K–6500 K, average life L70B50: 50000 hours, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, diffuser, electronic driver, etc. as required directly on the wall, including connections, etc. as required |
| 237 | Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round / square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI ≥80 , UGR (Unified Glare Rating) ≤ 19 Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. |
| 238 | Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim. |
| 239 | 5 - 7 watt |
| 240 | 12 - 15 watt |
| 241 | Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F≥0.95, IP20, CRI ≥80, UGR (Unified Glare Rating) ≤ 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.. |
| 242 | Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness ≥ 0.50 mm) |
| 243 | CRCA Sheet Body (Thickness ≥ 0.50 mm) |
| 244 | 36 watt |
| 245 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66, IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC As per CISPR 15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, |
| 246 | Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 247 | 45 watt |
| 248 | Providing and fixing a metallic louvred shutter suitable for following sizes exhaust fan, the louvres should be able to open when the fan is on and close when the fan is turned off, on the existing opening on the wall, etc., as required. |
| 249 | 300 mm |
| 250 | 380 mm |
| 251 | Providing and fixing 3 mm thick PVC/ phenolic laminated round sheet cover with a minimum of 170 mm dia on the existing fan box with two screws, etc., as required. |
| 252 | Providing and fixing 3 mm thick PVC / phenolic laminated round sheet cover on the existing junction box with two screws, etc., as required. |
| 253 | Supplying and fixing following rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 254 | 40 A/63 A Double pole |
| 255 | Supplying and fixing following rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 256 | 40 A/63 A Triple pole and neutral |
| 257 | Fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, in recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required including making good the damage to match the adjacent surface, etc., as required.. (But without MCB/RCCB/Isolator) |
| 258 | 6 to 16 way, MCB DB |
| 259 | Fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 260 | SP/SPN/ DP/ TP/TPN MCB |
| 261 | Supplying and fixing of following size PVC Saddles with base and screws on existing PVC / steel conduit etc as reqd (Precision / AKG /Polycab /Finolex / Anchor/ GM)i) 20 mm |
| 262 | Supplying and fixing of following size PVC Saddles with base and screws on existing PVC / steel conduit etc as reqd (Precision / AKG /Polycab /Finolex / Anchor/ GM)i) 25 mm |
| 263 | Rewinding of following size ceiling fan / exhaust fan/ Wall fan motor including complete removal of existing burnt out winding and rewinding of the fan with suitable size enameled copper wire, including sleeving, suitable insulation materials, varnishing etc., complete with dismantling and reassembling after repair, including connection testing etc. as required. Removed winding wire shall be retained by the contractor and suitably credited with its value and net value to be quoted. |
| 264 | 1200mm Sweep ceiling fan |
| 265 | 1400mm Sweep ceiling fan |
| 266 | Wall Fan upto 400 mm |
| 267 | Rewinding of stator winding of following size exhaust fans with suitable size enameled copper wire (as per manufacturer specification) including slaving of stator suitable insulation materials ie “E” class varnish complete with dismantling and reassembling after repair i/c connection testing etc as required (Brunt copper wire will be retained by the contractor). |
| 268 | 300mm / 380 mm exhaust fan |
| 269 | 450 mm exhaust fan |
| 270 | Providing and replacing ball bearing in following size ceiling fan/exhaust fan, including removing old ball-bearing, installing new ball bearing and testing the fan, etc., as required. (Scrap material will be retained by the contractor). (Both side shield ball bearing of SKF/ NBC /TATA ) |
| 271 | 1200mm Sweep ceiling fan. |
| 272 | 1400mm Sweep ceiling fan. |
| 273 | 300mm/ 380 mm exhaust fan |
| 274 | 450 mm exhaust fan. |
| 275 | Providing and replacing 2.5 MFD fan capacitor in the ceiling fan/exhaust fan/wall fan, including connection and testing, etc., as required. (The old capacitor will be retained by the contractor). |
| 276 | Reconditioning of the oversized bush /bearing housing to a suitable ball bearing in the ceiling fan/ exhaust fan/ wall-mounted fans as required and assembling and testing of the fan after repair. All the scrap material should be retained by the contractor. |
| 277 | Providing and replacing the worn-out M.S. shaft of the exhaust fan /wall fan with a suitable size new shaft etc., as required, including removing the old shaft, installing the new shaft, and testing the fan. All the scrap material should be retained by the contractor. |
| 278 | Providing and fixing PVC clamp with connector for the ceiling fan capacitor in the existing ceiling fan, including connection, testing, etc., as required, including credit for the old PVC clamp, which will be retained by the contractor. |
| 279 | Supplying, installation testing and commissioning of BEE 5 star rating, 25 litres capacity water storage heater, with protection against over heating, Multifunction Safety Valve and external adjustable thermostat, with 16 A, 240 V, plug top and 02 nos flexible connection pipe suitable for working with 230V AC, 50 Hz, 1 Phase supply etc as required. (Make: Havells / Crompton/ AO Smith /Racold /Jaguar with 7 year warranty on inner tank, 3 year warranty on heating element, 2 year comprehensive Warranty) |
| 280 | Supplying and fixing PRCD (Portable Residual Current Device) Plug top, 16 A 30 mA rating including connection etc. as required. |
| 281 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 6 pin 15/16 A modular socket outlet and 2 nos. 15/16 A modular switch, connections etc. as required. |
| 282 | Supplying and fixing Plug top following rating including connection etc. as required. |
| 283 | 16 A, three pin, Plug top ISI marked |
| 284 | 6 A, three pin, Plug top ISI marked |
| 285 | Supplying and fixing Bakelite Sheet of following size with screw in the existing looping box/ panel including cutting the sheet to required shape and size complete etc as reqd. |
| 286 | 6 mm thick |
| 287 | Supplying and laying of G.I. pipe of 50 mm dia.(nominal), medium class, ISI marked in wall / floor including cutting chase, and making good the wall/ floor and finishing with matching surface after housing G.I. pipe in chase. ( for protection of UG cable) |
| 288 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 289 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 290 | Supplying and Laying of one number aluminium conductor, XLPE Insulated, PVC sheathed, armoured power cable of 1.1 kV grade , confirming to IS : 7098 (Part-1) 1988 of following size in the existing RCC/ HUME/ METAL/ DWC/PVC pipe as required. |
| 291 | 2 x 25 sq mm |
| 292 | Supplying and Laying of one number aluminium conductor, XLPE Insulated, PVC sheathed, armoured power cable of 1.1 kV grade , confirming to IS : 7098 (Part-1) 1988 of following size in the existing masonry open duct / along pole / loose /loop/ in panel for connections etc as required. |
| 293 | 2 x 25 sq mm |
| 294 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. [Make-Comet/Hex/Dowells/Jainson] |
| 295 | 2 X 25 sq. mm (22mm) |
| 296 | The road crossings of power cable through trenchless boring.Trenchless horizontal boring using Manual/ Machine Moling technique at 0.75 metre below the ground level for following size pipes, including survey of under ground utilities, excavation of pits, moling with the hole size not exceeding 20% of the pipe dia, backfilling, compaction and restoration of the pits to original condition etc. as required.The rates for moling, as indicated are inclusive of excavation of pits, backfilling, compaction and restoration of the pits to original condition. |
| 297 | Any damages occurred to other utilities during the Moling operation shall be immediately notified and rectified by the contractor without any cost implication to the Department.The length of the Hole (excluding the sizes of the pits on both ends) shall be considered for the measurement of Moling length. However, intermediate pits will consider in the moling length.i) Upto 200 mm dia DWC HDPE / G.I. /PVC |
| 298 | Supplying and installing the following size PVC trunking cable management system, complete with front cover, internal/external/flat angles, joints, junctions, end caps, and finishing accessories, etc. as required. (Make-Legrand/ Honeywell / OBO Beterman) |
| 299 | 100 mm x 50 mm |
| 300 | 32 mm X 12.5 mm |
| 301 | Supplying and fixing of following sizes module frame on existing trunking including arranging the cover making good the same as original complete etc. as required.(Make-Legrand/ Honeywell / OBO Beterman) |
| 302 | 1-3 Module Frame |
| 303 | 4-5 Module Frame |
| 304 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI suspenders including base of suitable size GI angle,G.I. bolts & nuts, fastner etc. as required |
| 305 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 306 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. |
| 307 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 308 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Tee\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors,suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. |
| 309 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 310 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray, including 1.6 mm thick G.I. sheet cover for protection against environmental conditions, provided in convenient sections and joined with suitable connectors. The assembly shall be suspended from the ceiling or fixed to the wall/floor using G.I. suspenders or G.I. angle iron brackets, complete with G.I. bolts, nuts, and all other necessary accessories as required. |
| 311 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 312 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Bends\\" with 1.6 mm thick G.I. sheet cover for protection against environmental conditions, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner or fixed on the wall /floor with G.I. angle iron brackets, including G.I. bolts & nuts, etc. as required. |
| 313 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 314 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Tee\\" with 1.6 mm thick G.I. sheet cover for protection against environmental conditions, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner or fixed on the wall /floor with G.I. angle iron brackets, including G.I. bolts & nuts, etc. as required. |
| 315 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 316 | Supplying, installation, testing, and commissioning of 10 Watt/meter, IP-65 rated LED rope/strip light of approved make and color, including suitable electronic driver/adapter, mounted on walls, building facades, terraces, or ceiling coves. The work includes the provision and fixing of all necessary mounting accessories such as mounting clips, saddles, adhesive/glue, end caps, and connectors, complete in all respects as per site requirement and the direction of the Engineer-in-Charge. |
| 317 | Dismantling of the existing switch accessories like switches, sockets, and MCBs, etc., as required. |
| 318 | Dismantling of the existing ceiling rose, holder, and wall bracket and depositing the same with the listing of materials in the store. |
| 319 | Dismantling of existing fluorescent fitting from ceiling/ wall including making good the damage to match the adjacent surface, etc., as required. |
| 320 | Dismantling of the existing ceiling fan/ exhaust fan of any size installed in the building and depositing it in the MMC store. |
| 321 | Dismantling of the existing recessed vertical type or horizontal type TPN MCB distribution board of any size along with MCBs and other accessories, including making good the damage to match the adjacent surface, etc., as required. |
| 322 | Dismantling of the existing recessed SPN MCB distribution board of any size along with MCBs and other accessories, including making good the damage to match the adjacent surface, etc., as required. |
| 323 | Dismantling of the existing recessed switch board of light points/power points, power/light plug points/socket outlet metal boxes of any size, along with phenolic laminated sheet, switches, sockets, etc., making good the damage to match the adjacent surface, etc., as required. |
| 324 | Dismantling wires from the following sizes, existing circuit/submain/power wiring conduits, complete as required. The length of the conduit from which the wires are removed will be measured for payment purposes, irrespective of the number of wires in it.Above 25 mm conduits. |
| 325 | Dismantling wires from the following sizes, existing circuit/submain/power wiring conduits, complete as required. The length of the conduit from which the wires are removed will be measured for payment purposes, irrespective of the number of wires in it.Up to 25 mm conduit. |
| 326 | Less credit for the unserviciable items dismantled items during execution of the work. |
| 327 | Assorted PIANO Type Switches |
| 328 | Assorted PIANO Type Sockets |
| 329 | Assorted Bell push/PIANO Type |
| 330 | Assorted Call bell buzzer single phase |
| 331 | Assorted Brass batten/ angle holder/Brass Bracket |
| 332 | Assorted Fan regulator/resistance type |
| 333 | Assorted Telephone Socket outlet |
| 334 | Assorted T.V. Socket outlet |
| 335 | Assorted Capacitor, 3.15/2.50/2.25 mfd |
| 336 | Assorted 1200/1400 mm sweep ceiling Fan with blades |
| 337 | Assorted Fresh Air/ Exhaust FAN PVC up to 250 mm sweep. |
| 338 | Assorted Exhaust fan metallic up to 300 mm sweep. |
| 339 | Assorted Exhaust fan metallic above 300 mm sweep and up to 450 mm sweep. |
| 340 | Assorted Wall Bracket Fittings PVC |
| 341 | Assorted Wall Bracket Fittings metallic |
| 342 | Assorted fluorescent Light Fittings |
| 343 | Assorted Bulk Head Fittings |
| 344 | less credit for the dismantled Copper wire wires from light points/ circuit/ submain/power circuit wiring,. |
| 345 | less credit for the dismantled aluminium wire wires from light points/ circuit/ submain/power circuit wiring,. |
| 346 | Assorted metal switch box. |
| 347 | Assorted MCB DB SPN with out MCBs |
| 348 | Assorted MCB DB TPN with out MCBs |
| 349 | Assorted MCB SP |
| 350 | Assorted MCB DP |
| 351 | Assorted MCB TP AND TP&N Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysJul 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender