Tender For Construction Of 6 Acr (Additional Class Room) At Residential Upgraded High School,Bamandiha, District :- Lohardaga
Tender Value
1.82 Crore
Estimated cost
Bid Submission
29 Jul 2026
2 days left
EMD
3.70 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gumla → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of 6 Acr (Additional Class Room) At Residential Upgraded High School,Bamandiha, District :- Lohardaga
BOQ
| Sl. No. | Item Description |
| 1 | Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth a obtained to a distance up to 50M including all lifts with leveling ramming the foundation trenches removing roots of trees shurbs all complete as per approved design and per building specification and direction of E/I. |
| 2 | Extra for earth work in hard soil as per specification and direction of E/I. (vide classfication of soil item - B) |
| 3 | Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume). |
| 4 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including' cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume). |
| 5 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including' cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume). |
| 6 | Providing designation 75 A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l. |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 8 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 10 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 11 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size). |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 13 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 15 | Providing designation 75 A brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l. |
| 16 | Providing designation 75 A brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to2.5 including providing 10 mm thick mortar joints cost of screening materials , scafolding , raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/l. |
| 17 | Reinforced cement concrete work in beam, suspended floors,roofs having slop 15 landings, balconies, shelves,chajjas, lintels,band,plain window sills,staircases and sporal stair case above plinth level up to floor five level,excluding the cost of centring,shuttering,finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-|||) : 3 graded stone aggregate 20 mm nominal size) |
| 18 | Centring and shuttering including strutting,propping etc. and removal of form for (Lintels,beam plinth beam,girders,bressumers and cantilevers.with water proof ply 12mm thick) |
| 19 | Reinforced cement work in arches,archibs,domes,vaults,shell,folded plate and roof having slope more than 15 up to floor five level,excluding the cost of centring,shuttering,finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-|||) : 3 graded stone aggregate 20 mm nominal size) |
| 20 | Centring and shuttering including strutting,propping etc. and removal of form for (Suspended floor,roof,landing,balcconies and acces platform with waterr proof ply 12 mm thick) |
| 21 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M 1.5 including screening curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 22 | Providing 19 mm thick waterproof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved waterproofing compound including screening, curing with all leads and lifts of water, scaffolding taxes, and royalty all complete as per building specification and direction of E/l. |
| 23 | Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M 1.5 including screening curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 24 | Supplying, fitting, and fixing good quality, well dressed and well-seasoned sal woodwork in Chaukat in doors, windows, skylight, fanlights, and celestial windows openings, including wedge over clamps all complete including the application of two coats of wood preservative of approved quality on the surface butting walls and lintels all complete as per building specification and direction of E/l |
| 25 | Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush shutters in doors and windows with black board core blended with high quality phenol formal dehyde synthetic resin both side commercial veneered of standard make with oxidised iron fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/l. |
| 26 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. |
| 27 | Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth , carriage of grill to work site, hoisting as per building specification and direction of E/l. (where materials is not supplied by the deptt.) |
| 28 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as perarchitectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 29 | For fixed portion Powder coated aluminium(minimum thickness of powdercoating 50 micron)For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) - Powder coated aluminium (minimum thickness of powdercoating 50 micron) |
| 30 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in- charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness |
| 31 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.With 12 mm mild steel U beading |
| 32 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour an shade, with necessary screws etc. complete.Twin rubber stopper |
| 33 | Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete. |
| 34 | Supplying, fitting and fixing callapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2 mm at 100mm. centres and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40x40x6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangements, stoppers, handles, including applying a priming coat of red lead paint, carriage , hoisting and taxes all complete as per building specification and direction of E/l. |
| 35 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing rust , dirt, , scales , smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/l. ( Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specification) |
| 36 | Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l. |
| 37 | Providing and applying white cement-based putty of the average thickness of 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 38 | Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 39 | Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/l. |
| 40 | Providing 50mm thick cement concrete flooring (1:2:4) with 20 mm to 6mm size graded stone chips finished with flooring coat of neat cement in panels including cost of curing finishing the surface smooth by rubbing with carborandum stone taxes royalty all complete as per building specification and direction of E/I |
| 41 | Providing and laying 15 mm - 23 mm thick kotah stone slab flooring of approved size, texture and colour over 19mm thick base of lime morter (1:1:1) (lime putty : surkhi: coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.(i) 300 x 300 mm size |
| 42 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.Granite stone slab of colour black, Cherry/Ruby redArea of slab over 0.50 sqm |
| 43 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineerin-Charge.Granite work |
| 44 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 45 | Providing Toe steel reinforcement of 8mm dia to 32mm dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 8 MM |
| 46 | 10 MM |
| 47 | 12 MM-25 MM |
| 48 | Waterproofing for old and new roof slab: - Providing and laying waterproofing treatment of roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible material applied with a brush, roller or spray waterproofing coating as per manufacture specification with following steps:- (a) Surface preparation: - providing and cleaning of the concrete surface to remove dust, oil, and grease including removal of existing loose paint/coating, and laitance by cleaning with compressed air and water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, and leakage. On identification of seepage, cement grouting to be done with non-shrink expanding admixture of sika India Pvt. Ltd. / MYK Schomberg / Dr. Fixit/ Fosroc or equivalent. Providing and repairing all corners and joints such as those between the parapet wall and roof slab etc shall be chamfered with 150mm X 150mm fillet with mortar ( cement: sand- 1:4) admixed with an acrylic polymer of sika/ Fosroc/ MYK Schomberg / Dr. Fixit/ Fosroc or equivalent. Before chamfering, a prime coat shall be given with the slurry of acrylic polymer. Repairing surface irregularities, damaged concrete base slab, dead crack if any, with acrylic polymer modification repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete.(b) 1st coat:- Apply 1st coat of two-component acrylic modified, ready to use, flexible cementitious material on the surface dry roof and inside wall of parapet wall up to 600 mm by brush or roller. after 1st coat of application, 45gsm of fiberglass cloth to lay when the first layer is still green. 1st coat should be applied @ 1.50 kg/Sqmt/coat. For measurement will be measured (c) 2nd coat:- To apply the 2nd coat of two-component acrylic modified ready to use, flexible cementitious material right angle to the 1st coat over the glass surface. 2nd coat should be applied @ 0.7 kg /sqm/coat. For measurement, Cheniere treated surface will be measured. After three days of drying the 2nd coat. the rainwater outlet is to be plugged and a ponding test is to be done for 48 hours to identify seepage, leakage from the soffit, and if found necessary rectification is to be done as per the satisfaction of E/C. the waterproof coating is to be protected from damage before screed over it. Waterproofing bond:- Sika top seal 109i / Fosroc brush bond RFX/Dr. Fixit pidiffin 2k / MYK Aquafin TG. Product Performance- chemical base part A: acrylic copolymer, Part B: specially graded cementitious powder density 1.6kg/l (mixed density) at +27 degree c tensile strength ~ 2N/mm2 after 28days (with fiber cloth )( According to ASTM D 2370) pull out bond strength ~ 2N/mm2 (concrete failure) (According to ISO 4624) Slant- Shear Bond strength ~4N/mm2 (According to FIP 5.15) elongation at Break ~35% without Fiber Cloth and 20% with Fiber Cloth (According to ASTM D 2370)(d) Protection of the treated surface with PCC:- the treated surface should be covered with 25mm/50mm PCC of M-20 grade (1:1.5:3) with proper slope (1:120) toward the rain outlet in Alterna panel of 2mtx2mt keeping 6mm gape between the plane joint integral waterproofing admixture conforming to IS 2645 @ of 100ml per bag of cement to be added in the screed concrete ( paid separately for this item) all corner shall be chamfered with 150mm x 150mm fillet. The rainwater outlet shall be just leveled with the screed concrete to ensure smooth discharge of water- the peripheral gapes between PVC pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensitive epoxy putty of sika/ Fosroc/ MYK Schomberg / Dr. Fixit/ Fosroc. For measurement, the entire treated surface will be measured(e) Groove of PCC surface should be filled with polysulphide sealant. (paid separately) . brand- sika/ Fosroc/ MYK Schomberg / Dr. Fixit/ Fosroc. Warranty for five years. |
| 49 | Covering the treated surface with PCC:- 25mm thick Cement Concrete (1:1.5:3) maintaining the slop in 2mt x 2mt panels with approved quality of stone chips of 20 mm to 6 mm size graded and cleaned sand of F.M 2.5 to 3 including screening, shutting and mixing cement in mixture with an admixture of integral waterproofing and placing in position, striking curing, taxes, and royalty all complete as per building specification and direction of E/I. the panel that has been left should be cast the next day. there should be a 6mm gap between panels. Brand- sika_Plastocote plus, MYK Proof WP 10, Fosroc- conplast x 4211C,Dr. Fixit Pidiproof LW+ or Equivalent. |
| 50 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 51 | providing and filling of 6mm thick Groov between 50 mm PCC panels with 6 mm thick 25mm deep thermocol strip and filling the rest 25mm with polysulphide sealant (poring Grade) as per drawing and technical specification and direction of E/I.(With 18% GST) Brand:- Sika-polysulphide, Fosroc-thiols 600, Dr. Fixit pidi seal PS (42P), MYK SEAL PS or Equivalent |
| 52 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 53 | Providing 250mm. wide brick drain in cement mortar (1:6) with av. 250mm. clear depth and 250mm. apron including cost of earthwork involved with 75 mm. ~ cement concrete (1:4:8) over one brick designation 75A flat soling in proper grade and slope at the base, the drain duly plastered in C.M.(1:3) with punning over exposed surface all complete as per building specification and direction of E/l. |
| 54 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 55 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.110 mm bend |
| 56 | 110 mm Shoe |
| 57 | Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 58 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement: 4 coarse sand) and making good the wall etc. complete.110 mm |
| 59 | Wiring for light point /fan point/ exhaust fan point/ cell bell point, with 1.5 sq. mm FR PVC insulated copper conductor singel core in surface/recessed PVC conduit, with modular type switch, modular plate sutable GI box etc as required Group C |
| 60 | Power Plug wiring in PVC Conduit (2X4 Sq.mm) :- Wiring for light/power plug with 2x4 Sq.mm FR PVC insulated copper conductor songle core cable in surface/recessed PVC conduit along with 1 No. 4 Sq.mm FR PVC insulated copper conductor single core cable for loop earthing etc. as required. |
| 61 | Circuit/Sub-main wiring in PVC Conduit:- Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required.2x1.5 sq.mm +1x1.5 sqmm earth wire |
| 62 | 2x2.5 Sqmm + 1x2.5 sqmm earth wire |
| 63 | Supplying and fixing of the following size of PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20mm |
| 64 | Supplying and fixing of following modular switch / socket on the existing modular plate & switch box including connection but excluding modular plate etc. as required.1.24.1 5/6 amps, one way switch |
| 65 | 1.24.4 5/6 amps, 3 pin socket outlet |
| 66 | S/F Modular type electronic fan regulator -Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 67 | Supplying and fixing modular blanking plate on the existing modular plate & switch excluding modular plate et. As required. |
| 68 | Supplying and fixing following size / modular, G.I box along with modular base & cover plate for modular switches in recess etc as required.6 module (78mm x 205mm x 50mm) |
| 69 | 12 module (135mm x 205mm x 60mm) |
| 70 | Supplying and fixing suitable GI box with modular plate and cover in front on surface of in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch. Connection, painting etc. as required (For light plugs to be used in non residential buildings) |
| 71 | S/F power plug point with modular type accessories:- Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc as required. |
| 72 | S/F Ceiling Rose:- Supplying and fixing 2 pin ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 73 | S/F T.P. MCB DB - Supplying and fixing following way, three pole and netural, sheet MCB ditribution board, 415 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way (4+24), Double door, Horizontal type |
| 74 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, \\"B\\" series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as required.6/32, single pole, \\"B\\" series |
| 75 | S/F DP MCB Isolator - Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required63 amp |
| 76 | G.I. Earth electrode with salt/charcoal - Earthing with G.I. earth pipe 4.5 mtr. Long, 40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required |
| 77 | S/L 8 SWG copper wire in ground - Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth, including soldering etc. as required |
| 78 | P/F G.I lighting conductor final: Providing and fixing of lighting conductor final, made of 25mm dia 300mm long, G.I. tube having single prong at the top, with 85mm dia 6mm thick G.I base plate including holes, etc. complete as required. |
| 79 | Reverting, sweating and soldering of copper /GI tape (With another copper / G.I tape, base of the final or any other metallic object ) as required. |
| 80 | Providing and fixing G.I. tape 20mm x 3 mm thick on parapet surface of wall for lighting conductor as required. (for horizontal run) |
| 81 | Providing and fixing G.I. tape 20mm x 3 mm thick on parapet surface of the wall for lighting conductor as required. (for vertical run) |
| 82 | P/F Testing joint for G.I. lighting conductor:-Providing and fixing testing joint made of 20mm x 3mm thick G.I strip 125mm long. With 4 nos. of G.I bolts. Nuts chuck nuts and spring washers etc. complete as reuired |
| 83 | Supplying PVC/XLPE insulated PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor- 3.5 core, 95 sq.mm |
| 84 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 35sq mm but not exceeding 95 sq mm direct in ground including excavation, sand cushionng, protective covering and refilling the trench etc as required. |
| 85 | Supply Installation, testing and commissioning of follwing size ceiling fan 3 Blades confirming to IS:374:2019 including wiring the down rods of standard length (upto 30cm) with 1.5 sq.mm. FR PVC insulated, copper wire sutable for 230V 50HZ, single phase supply etc. complete as required.1400 mm (56\\") Ceiling Fan |
| 86 | S.I.T.C of floowing rating surface mounted LED tube light fitting suitable for 230V 50HZ, single phase supply etc. complete as required9.5.2 20/22 W LED Tube light |
| 87 | S/F ITC of main cubical panel mode of 14 SWG CRCA sheet steel double door type powder coated having IP 54 suitable for operation as 415 volts 3 phase 50 HZ 200 amp copper bus bar on load change over-200 amp 4 pole, inter connection wires, along with analog volt ammeter selector switch CT, indicating liamps etc. asrequired make seimens, L & T, ABB with thermo magnetic release and front rotary handle, etc. complete.4 pole MCCB 200 Amps,35 KA with fixed thermal magnetic setting. 1 NO. 200 amps, 4 pole Changeover 1 NO.25-100 amps, 10 KA fixed thermal setting. 2 NO.25-100 amps, 16 KA, fixed thermal setting. 2 NO. 6/32 A,DP MCB 2 NO.200 amp 415 V heavy duty three phase with neutral bus bar chamber. 1 NO. LED indicator lamp R/Y/G/B 4 NO.3-way 4 pole Selector switch 1 NO.Digital Volt Mtr. (0-500Volt)- 3 phase class 0.5 - 1 NO. Digital Amp Mtr. (0-500Amp)- 3 phase class 0.5 - 1 NO.C.T. Coil of C.T. ratio 300/5 - 6 NO. 100 Amp, TPN switch 63 Amp power contactor - 4 NOS , 200 Amp power contactor - 1 NOS, 100 Amp, TPN switch disconnector fuse unit rewireable type- 2 Nos Add 30% for Assamble ChargeInstallation,testing & commisioning +C.P. & OHC @14.95 % |
| 88 | CARRIAGE OF MATERIAL (a) Cement |
| 89 | (b) Steel |
| 90 | (c ) Sand |
| 91 | (d) Stone chips |
| 92 | (e) Stone Metal |
| 93 | (f) Red Bricks |
| 94 | ADD GST(18%) |
| 95 | LABOUR CESS Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysJul 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender