Public Administrative Department Local Bodies Closing in 9 days TDR #56555118

Tender For Installation Of 25 Kva Sub Station At Akhuapadar Kalayanmandap Nac Odagaon

Issued by Local Bodies · Nayagarh, Odisha
Tender Value
Ref. Documents
Estimated cost
Bid Submission
30 Jul 2026
9 days left
EMD
6650
Bank guarantee accepted
Document Fee
4000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nayagarh → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Installation Of 25 Kva Sub Station At Akhuapadar Kalayanmandap Nac Odagaon

BOQ

Name of Work:- Installation of 25 KVA Sub Station at Akhuapadar Kalayanmandap NAC Odagaon
Sl. No. Item Description
1WPB(GI) pole 160x152(11Mtr.Long,30.44KG/Mtr.) (Total pole weight with base plate and stiffner =334.84kg +10.74kg =345.58KG)
2Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each channel length 1.2 mtr., 2 no's channel required =( 2x9.56x1.2)
3Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 8 no's required = (8x2.36x0.280)
4Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each channel length 0.306 mtr., 2 no's channel required =( 2x9.56x0.306)
5Danger Plate, 1 no's.
6Back Clamp for danger Plate 25X3 mm. flat(GI), 0.59Kg/Mtr. Flat GI of 0.510mtr length 1 no's = (1x0.59x0.510)
7GI barbed wire anticlimbing device 3 Kg. Per support
8Back Clamp for anticlimbing device 25X3 mm. flat GI, 0.59Kg/Mtr. Flat GI of 0.510mtr length 4 no's = (4x0.59x0.510)
911 KV pin insulator polymer
10H W fitting(B&S) 70KN, 3Bolt
11Disc insulator (B&S) 70 KN polymer
12Earthing of Support ( Coil Type )
13No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing
14NON METALIC TIES -11KV 55SQ.MM CVRD AAAC
15IPC of 55sq.mm AAAC (For covered conductor)- 11KV
16Spike GI (Using 50x6mm flat GI welded with 8mm square bar)2nos. Of spike per set in each pole
17GI Nut , Bolt & Washer of different sizes (3.55 Kg each Cut Pole)
18Black Paint (GIS Numbering & Zebra stripping for background)
19Yellow Paint (GIS Numbering & Zebra stripping for background)
20Stock, Storage & Insurance i.e 3% of A
21Contigency @ 3% of C
22Tools & Plants @ 2% of C
23Transportation @ 7.5% of C
24Erection Charges @ 5% of C (except Trf/Breaker/WPB/ H-Pole/HT stay set/PSC pole)
25Erection Charges @ 10% of C (except Trf/Breaker/WPB/ H-Pole/HT stay set/PSC pole)
26Concreting ratio 1:1.5:3 (500mmX500mmX1800mm) = 0.45Cu.mtr per pole
27Couping ratio 1:1.5:3 with dimension ( 500X500X450)= 0.1125 Cu mtr per pole
28WPB(GI) pole 160x152(11Mtr.Long,30.44KG/Mtr.) (Total pole weight with base plate & stiffner =334.84kg +10.74kg =345.58KG)
29Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each channel length 1.2 mtr., 2 no's channel required =( 2x9.56x1.2)
30Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 8 no's required = (8x2.36x0.280)
31Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each channel length 0.306 mtr., 2 no's channel required =( 2x9.56x0.306)
32Danger Plate, 1 no's.
33Back Clamp for danger plate 25X3 MM flat GI 0.59 Kg per Mtr flat GI of 0.510 Mtr. Length
34GI barbed wire anticlaimbing device 3 Kg per Support
35Back Clamp for anticlimbing 25X3 MM flat GI 0.59 Kg per Mtr flat GI of 0.510 Mtr. Length
3611 KV pin insulator polymer
37H W fitting(B&S) 70KN, 3Bolt
38Disc insulator (B&S) 70 KN polymer
39Earthing of Support ( Coil Type )
40No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing
41NON METALIC TIES -11KV 55SQ.MM CVRD AAAC
42IPC of 55sq.mm AAAC (For covered conductor )-11KV
43SpikE GI (Using 50x6mm flat GI welded with 8mm square bar)2nos. Of spike per set in each pole
44HT Stay Clamp 50x8 mm flat GI 3.14 Kg per Mtr. 0.551 Mtr Length 2 Nos. of required
45HT Stay set complete
46HT Stay Insulator Type C
477/10 SWG stay wire 15 per stay
48GI Nut , Bolt & Washer of different sizes (3.55 Kg each Cut Pole)
49Black Paint (GIS Numbering & Zebra stripping)
50Yellow Paint (GIS Numbering & Zebra stripping for background)
51Stock, Storage & Insurance i.e 3% of A
52Contigency @ 3% of C
53Tools & Plants @ 2% of C
54Transportation @ 7.5% of C
55Erection Charges @ 5% of C (except Trf/Breaker/WPB/ H-Pole/HT stay set/PSC pole)
56Erection Charges @ 10% of C (except Trf/Breaker/WPB/ H-Pole/HT stay set/PSC pole)
57Fixing of 11KV Line complete stay set bincludes 1)Turn buckle assembly2)Stay rod& Stay plate3)Stay Insulator 4)Stay wire 5) Stay clamps with nuts & bolts BA will do the excavation including excation ,supply of .5Cum cement concrete foundation 1:2:4 size 500mmx500mmx800mm using 20mm BHG metal with all labopur and material as per TPCODL Drawing and standard
58Concreting ratio 1:1.5:3 (500mmX500mmX1800mm) = 0.45Cu.mtr per pole
59Couping ratio 1:1.5:3 M-20 with dimension ( 500X500X450)= 0.1125 Cu mtr per pole
6055sq.mm XLPE Insulated XLPE Covered Conductor
61Stock, Storage & Insurance i.e 3% of A
62Contigency @ 3% of C
63Tools & Plants @ 2% of C
64Transportation @ 7.5% of C
65Erection Charges @ 10% of C (except Trf/Breaker/WPB/ H-Pole/HT stay set/PSC pole)
66WPB 160x152 (11 Mtr. Long, 30.44 KG/Mtr.)
67Top Channel GI 100 X 50 X 6 MM (3000 mm long) (9.56Kg./Mtr, 2 No's.) (Each 2x3000x9.56= 57.36 Kg)
68Fish Plate GI 50x6mm 2.36kg/mtr. Each .280 mtr lenth 16nos required=(16x2.36x0.280)
69AB Switch Mounting Channel 75x40x4.8 mm GI Channel (3000mm long )7.14kg/mtr. 2 nos(each 2x3.00x7.14=42.84kg)
70AB switch side support channel 75x40x6mm 9.85Kg/Mtr each channel lenth 0.35mtr. 2nos channel required =9.56x2x0,35)
71Channel suport GI for down pipe 75x40x4.8mm 7.14kg/mtr each channel lenth 0.8mtr. 1nos channel required (=(7.14x0.8x1)
72HG/DO Fuse mounting channel 75x40x4.8mm GI Channel (810mm long 2nos) each 2x0.810x7.14=11.57kg
73Cantilever Support Channel 75x40x4.8 mm GI Channel (810 mm long,2 No's.) (7.14Kg./Mtr., 2 No's.) (Each 2x0.810x7.14= 11.57 Kg)
74Cantilever Support Angle 50 X 50 X 6MM GI (1282 mm long) (4.5Kg./Mtr, 2 No's.) (Each 2x1.282x4.5= 11.54Kg)
75Transformer Base GI Channel 100 X 50 X 6 MM (3000 mm long) (9.56Kg./Mtr, 2 No's.) (Each 2x3.000x9.56= 57.36 Kg)
76Transformer Base Support GI Channel 100 X 50 X 6 MM (515 mm long) (9.56Kg./Mtr, 2 No's) (Each 2x0.515x9.56= 9.85Kg)
77Transformer Belting Angle 50 X 50 X 6MM GI (3000 mm long)(4.5Kg./Mtr, 2 No's) (Each 2x3.0x4.5 Kg)
78Transformer Belting Support Angle 50 X 50 X 6MM GI (580 mm long)(4.5Kg./Mtr,2 No's) (Each 2x0.580x4.5= Kg)
79LTDB Mounting Angle 50 X 50 X 6MM GI (1000 mm long)(4.5Kg./Mtr, 2 No's) (Each 2x1x4.5 Kg)
8050x6mm GI Flat for earthing, 2.36kg/mtr., (2.5x7 mtr. For mesh formation, 12 Mtr. For LA and 2.5 mtr. For raising, 11 mtr for AB switch, 2.8 mtr for HG Fuse, 5x2 mtr. for DTR Nutral, (1.3+4.5) mtr. For DTR Body, 0.500 mtr for LTDB & AB Switch operating handle, 3 mtr. for Fencing) ( Each 65.6x 2.36= 154.81 Kg)
8125 KVA , 11/ 0.4 KV (AL) Transformer BIS Energy level II Ammendment-4
82LT Distribution Box with MCCB, Aluminium Busbar of single Bay with kit kat fuse for 63 KVA S/S
8355mm2 All Alloy Aluminum Conductor (AAAC) - PVC Insulated (50 Mtr. Each Dtr.)
844Cx35SQ.MM LT XLPE Cable
85AB Switch(11KV,200A.3pole,50Hz)
86H.G.Fuse( 11KV.200A.3Pole)
87WEDGE CONNECTORFOR 55SQ.MM CONDUCTOR
88POLYCARBONITE BIRD GUARD
89Disc insulator (B&S)70 KN polymer
90H W fitting (B&S)70KN(3bolted)
91Lightning Arrester(12KV,10KA) Station Class 2
9211KV pin insulator polymer
93HT stay set complete
94HT stay Clamp (1.9Kg/pair)
95HT stay insulator TYPE-C
967/10 SWG GI stay wire, Grade -2 (15Kg./ Set)
9740 mm Nominal bore GI pipe (medium gauge) earthing device with 3 mtr .Long
98GI Nuts & Bolts of Assorted size (25 Kg/ DSS DP)
99GI Barbed wire/Anticlimbing device (3Kg /Pole)
100Back Clamp for anti climbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8no's (2x0.59x0.510)
101Danger plate 11kv
102Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8no's (2x0.59x0.510)
103Name plate
104Yellow Colour Paint for Background
105Black Colour Paint for numbering
106Stock, Storage & Insurance i.e 3% of A
107Tools & Plants @ 2% of C
108Transportation @ 7.5% of C
109Erection Charges @ 5% of C on Trf/Breaker/WPB/ H-Pole/HT stay set/PSC pole)
110Erection Charges @ 10% of C (except Trf/Breaker/WPB/ H-Pole/HT stay set/PSC pole)
111Concreting ratio 1:1.5:3 (500mmX500mmX1800mm) = 0.450Cu.mtr
112Couping ratio 1:1.5:3 M-20 Grade with dimension ( 500X500X1700)= 0.425 Cu mtr per pole for 10mtr. PSC pole DP
113PCC ratio 1:3:6 M10 Grade for DSS Area 5x3x0.1=1.5Cu.mtr
114Fixing of stay set with 0.5Cum cement concrete foundation 1:3:6 size ( 900mmx600mmx900mm) using 40mm BHG metal with all labor and material except stay set , stay wire , stay insulator .
115Construction of earthing chamber including installation of earthing pipe. Making earthing chamber including excavation soil treatment with bentonide powdwer calculation of earth resisrance ,including installation of 3Mtr. GI pipe 40mm/50mm including welding of flat GI around pipe
116Laying of 4Cx95sq.mm LT XLPE Cable
117SITC and Errection of GI Fencing with Gate
118Supply of AL lugs suitable for 95sq.mm cable /conductor Crimping with cable and Fixing/connecting include supply and errection of PVC table as per voltage requirement.
119Supply and errection of double compression flameproof Type Glanding for armoured cable3 ,5/4C 50-95sq.mm including making hole in Base plate and dressing of cable along with vermin proofing properly supply to be done as per the TPCODL specification and approved make dowells.
120Guarding Channel GI 75X40X5.8mm 7.14kg/mtr. Each channel GI Lenth2.2mtr. 4nos channel GI required=(4x47.14x2.2) for single pole
121No-6 GI wire .192kg/mtr. For main string
122No-8 GI wire .131kg/mtr. For lacing
123Eye bolt 236mm ,16mm dia 1.577kg/mtr.
124GI Pipe earthing 40mm 3mtr. Long
12550X6MM Flate GI for earthing 2.36kg/mtr. 10.7mtr. For each raising =10.7x2.36
126Stock, Storage & Insurance i.e 3% of A
127Contigency @ 3% of C
128Tools & Plants @ 2% of C
129Transportation @ 7.5% of C
130Erection Charges @ 10% of C (except Trf/Breaker/WPB/ H-Pole/HT stay set/PSC pole)
131Construction of earthing chamber including installation of earthing pipe. Making earthing chamber including excavation soil treatment with bentonide powdwer calculation of earth resisrance ,including installation of 3Mtr. GI pipe 40mm/50mm including weld Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56555118
AUTHORITY Local Bodies
TENDER VALUE Ref. Documents
LAST DATE 30-07-2026
Authority
Authority Name Municipal Bodies
Work Description Tender for Installation Of 25 Kva Sub Station At Akhuapadar Kalayanmandap Nac Odagaon
Basic Detail
Tender No NAC-ODG-02/2026-27
Bidding Type Tender
Location
City Nayagarh
State Odisha
Key Dates
Publish Date 20 Jul 2026
Submission Date 30 Jul 2026
Open Date 31 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee 4000
EMD 6650
Exemption Available
Document List
84134189-e613-4033-afe8-3bbe39c9dab8.html
BOQ_602338.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Jul 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

84134189-e613-4033-afe8-3bbe39c9dab8.html

xls

BOQ_602338.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders