Tender For special Repair Of Em Water Sup Installations At Chuje Gg And special Repair Of Em Water Sources And Raw Water Collection Chamber At Various Locs Of Tawang Mil Stn Under Ge 859 Ews
Tender Overview
Project Description
Tender for special Repair Of Em Water Sup Installations At Chuje Gg And special Repair Of Em Water Sources And Raw Water Collection Chamber At Various Locs Of Tawang Mil Stn Under Ge 859 Ews
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 23-Jul-2026 | BOQ Corrigendum | BOQ | 10-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of cement concrete (un reinforced) in ground floors and paving n. exc. 15 cm thickness (below or above ground level) complete all as directed. |
| 2 | Demolition of cement concrete (Reinforced) of any description and in any position not otherwise specifically provided |
| 3 | M&L for PCC 1:4:8 type D2(using 40mm graded aggregate) as in foundations, filling and mass concrete etc. |
| 4 | M & L for RCC Nominal mix type B-1, 1:2:4 (20mm graded aggregates) Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete |
| 5 | M & L for RCC (Nominal mix) type B-1,1;'2:4 (20mm graded aggregates)Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses |
| 6 | M&L for MS TMT bars 10mm dia and over, cut to lenth, bend to shape required, including cranking, bending, sprially for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips. |
| 7 | M&L for form work to faces of walls,retaining walls ,abutments ,parapets and strairecase railings and similar work including attached pillasters,buttresses,etc ;vertical or to batter. |
| 8 | Demolition of stone, brick/PCC block masonry work built in cement mortar complete all as directed. |
| 9 | M&L for PCC 1:3:6 type C-1(20 mm graded aggregate) precast cement concrete block masonry with solid blocks exc 10 cm in width and setting in CM 1:6 etc complete. |
| 10 | M&L for Providing precast cement concrete type B1 1:2:4 (20mm graded stone aggregate) solid building blocks or slabs 10cm thick (with plain or interlocking joints as directed)setting in mortar 1:6 ,complete, in walls |
| 11 | Taking down cement plaster internal and external on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc |
| 12 | M & L for rendering 10 mm thick in CM (1:6) on fair faces of brick work or concrete surfaces finshed rough to receive tiles . |
| 13 | M&L Rendering 15mm thick CM (1:4) in two layers on fair faces of concrete surfaces of walls mixed with LWPC by weight of cement as per manufacturers instruction , finshing the surface even and smooth without using extra cement complete.(Note : LWPC measured and paid separately) |
| 14 | Supplied only liquid WPC |
| 15 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |
| 16 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. |
| 17 | M&L for 15 mm thick screed bed in CM (1:6) for laying floor finishes. |
| 18 | M & L for Non-skid ceramic tiles 6 to 7 mm thick coloured tiles( square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match. |
| 19 | M & L for 350 x 250 x 6 to 7 mm/450 x 300 x 6 to 7 mm thick glazed coloured ceramic tiles on vertical surface of wall set and jointed in neat cement slurry and pointed in white/coloured cement to match the shade. |
| 20 | Materials and Labour for plain cement concrete (1:3:6) type C-2 using 40 mm graded aggregate as in surface channels and drains complete all as specified and directed. |
| 21 | Materials and Labour for Extra for forming fair finishing to surfaces drain/channel 30 cm inner girth in cement concrete ,using extra cement incl forms, moulds etc complete all as specified and directed. |
| 22 | M&L for Rendering 15 mm thick CM (1:6) on fair faces in two layers of concrete surfaces of wall , finshing the surface even and smooth without using extra cement complete. |
| 23 | M&L for prep of newly plastered surfaces of walls and applying two coats of OBDover a coat of primer complete all as specified and as directed complete. |
| 24 | Supplied only liquid WPC |
| 25 | M&L for Virified Ceramic light shade tiles 7 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl screed bed with CM (1:6) 15mm thick for laying floor tiles complete all as specified and directed. |
| 26 | Dismantling plain or corrugated steel sheeting any thickness, complete all as specified and directed. |
| 27 | Supply and fix Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specifie |
| 28 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 29 | Dismantling timber scantlings 40 sq. cm and over in section, in any position, unframed work |
| 30 | M & L for Second class hard-wood in scantlings, clean sawn timber unframed and fixed. |
| 31 | Dismantling timber in fillets, rails, posts, rafters,purlins, etc. under 40 sq. cm in section |
| 32 | M&L second class soft wood plain fillets.square, rectangular or triangular in section, clean sawn, sectional area exc 13 sq cm and n exc 25 sq cm secured with nails |
| 33 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets. |
| 34 | M&L for 4mm thick plywood, (3 Nos of ply)grade BWR, type BB, fixed with nails to timber framework in ceiling |
| 35 | M&L for prepration of new wooden surfaces exc.10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 36 | Taking down chowkhat or frame exc. 1.5 sqm but n.exc 4 sqm each without taking off shutter from the frame complete all as specified and directed. |
| 37 | S&F II class HW plain solid straight chowkhats and frame wrought framed rebated on the soild rounded or chamfered put together with glue pinned at joints, complete all as specified and directed. |
| 38 | S & F 30 mm thick flush shutters,solid core construction with block board core and plywood face panel, commercial type on both sides, complete all as specified and directed. |
| 39 | Taking down chowkhat or frame n .exc. 1.5 sqm each without taking off shutter from the frame complete all as specified and directed. |
| 40 | M&L for 2nd class hard wood 30mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed. |
| 41 | Hacking out old broken glass (any hickness, size, quality )from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones |
| 42 | S & F 3.0mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.50 sqm in each pane. |
| 43 | Supply and fix mild steel butt hinges, medium weight, cold rolled 100 mm size , complete all as specified and directed. |
| 44 | Supply and fix Aluminium anodized barrel tower bolts of extruded section, 150 mm long, complete all as specified and directed. |
| 45 | Supply and fix Aluminium anodized barrel tower bolts of extruded section, 100 mm long, complete all as specified and directed. |
| 46 | Supply and fix Aluminium handles, cast type, anodized, 150 mm size , complete all as specified and directed. |
| 47 | Supply and fix Aluminium handles, cast type, anodized, 125 mm size , complete all as specified and directed. |
| 48 | Supply and fix, Aluminium alloy, anodised, sliding door bolts 200mm long, with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy 12mm dia, complete all as specified and directed. |
| 49 | Dismantling of fencing wire mesh, any type |
| 50 | Excavation in post holes (or similar holes) each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance n exc 50 m in hard/dense soil complete all as specifed and as directed |
| 51 | S&F Mild steel work of angle iron or flat iron etc for railings, balusters, nosing to steps including embedding in concrete and screwing etc, flat iron for posts & struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc & similar work conforming to Fe 290 complete all as specified and directed. |
| 52 | S & F MS Tie bars 50mmx6mm thick with screwed ends, nuts, washers and mild steel plates for walls, chimneys, roofs, arches, etc. king rods and straining bolts conforming to Fe 290 Gde-E-165. |
| 53 | Supply only Chain Link MS galvanized fencing any size and any type complete all as specified and as directed |
| 54 | Fixing only Chain Link MS galvanized fencing including wires any mesh, size and any type of standards rails, straining bolts etc including provision of binding wires complete all as specified and as directed. |
| 55 | S & F in repairs Galvanised 2 strand steel barber wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacing and straning and fixing to any type of standrad rails straining bolts including securing or tying at crossing with and provision of galvanised mild steel wire staples or steels pins including taking down etc as directed ( Each line of wore to be measured) complete all as specified. |
| 56 | Mild steel screw bolt 11 to 15 mm shank dia neck (machine made) with hexagonal or square head at one end and screws the other, or screwed both ends, each screwed end to be fitted with washer and one hexagonal or square nut exc 5 cm n.exc 10 cm long complete all as specified and as directed. |
| 57 | M&L for Preparation of new steel surfaces of any description over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 58 | Demolation of Stone slabs and tiles of any description or thickness infloors, aprons etc.laid ,bedded and pointed in any mortar , complete all as specified and as directed. |
| 59 | M & L Hardcore of gauge n exc. 63 mm,(broken stone & boulders) deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface |
| 60 | M&L for 100 mm thick PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as cement concrete in Sub-base floor and pavings etc complete all as specified. |
| 61 | M&L screed bed or bedding layer of mortar 20mm thick using CM 1:6 for laying floor finishes complete all as specified and as directed |
| 62 | M&L Chequered cement concrete tiles with grey cement and pigment of size 20cm x 20cm x 23 to 25mm/300cm x 300cm x 23 to 25mm thick set and jointed in neat cement slurry in floors complete all as specified and as directed |
| 63 | M & L Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. |
| 64 | Taking down carefully aluminium point wiring (light, fan, socket or power) complete and making good disturbed surfaces of walls, floors, etc. all as directed.including taking down fittings such as switches, ceiling roses, regulators, sockets,lamp holders, ceiling fittings, bulk head fittings, tube light fittings etc |
| 65 | M & L for One light point or one fan point controlled by one switch with 1.5 sq. mm size FRLS PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drown through in and incl PVC casing capping with its accessories and PVC Boxes for fixing switches/sockets etc. |
| 66 | M & L for One 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5 sq. mm size FRLS PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drawn through in and incl PVC casing capping with its accessories and PVC Boxes for fixing switches/sockets etc. |
| 67 | M & L for One 3 pin socket outlet, 5 Amps, independent, with cables 1.5 sq. mm size FRLS PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drawn through in and incl PVC casing capping with its accessories and PVC Boxes for fixing switches/sockets etc. |
| 68 | M & L for One 3 pin socket outlet, 15 Amps, independent, with cables 4 sq. mm size FRLS PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 4.0 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drawn through in and incl PVC casing capping with its accessories and PVC Boxes for fixing switches/sockets etc. |
| 69 | S&F Switch piano, flush type single pole, one way 5 Amp. |
| 70 | S&F Switch socket combination 2 in 1, 5 A flush type. |
| 71 | S&F Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type Universal. |
| 72 | S&F Ceiling rose, 3 phase/PVC/ polycarbonate, isolated body. |
| 73 | Supply and fixing in repair LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete as specified. |
| 74 | Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete as specified. |
| 75 | Supply and fixing in repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete as specified. |
| 76 | S & F Lamp holder, PVC/Polycarbonate type with back plate suitable for battern fittings complete. all as specified and directed by as engineer-in-charge. |
| 77 | S&F LED Bulb 9 watt cat part no LED ADORE PLUS 9W B22 WW 2 STAR LAMP complete all as specified and as directed by engineer-in-charge. |
| 78 | Supply and fix in repair exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 300 mm sweep with all fixing arrangement all as specified and as directed. |
| 79 | Supply and fix in repair electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. |
| 80 | S&F in repair of Single pole and neutral Sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20 Amps, 240 Volts, AC,50 HZ, completete all as directed and specified, including taking down old unserviceable plug socket and offering for credit. |
| 81 | S&F sheet metal enclosure distribution box 4 way TPN 415 volts with suitable size of rated bus bar double door complete including connecting up all as specified .and including taking down old item. |
| 82 | Supply and fixing in repair 415V 10KA 'C' curve miniature circuit breaker TPN 40 To 100 AMP poles and current carrying capacity in the DB complete with connection testing and commissioning all as directed and as specified. |
| 83 | Supply and fixing in repair MCB 5- 32 Amp SP 240V, 10KA 'C' complete with connection testing and commissioning all as directed and as specified. |
| 84 | Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground end vertically to a depth not less than 2.25 meter deep below ground level with top edge of the earth plate at a depth not less than 1.5 M below normal ground level connected to galvanized GI wire 4.0 mm as earthing lead by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and provision of concrete pit in PCC (1:3:6) type C1, pre-cast including RCC (1:2:4) type B1, cover slab 54 cm x 54 cm x 5 cm, reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways, one handle for lifting made out of 10 mm dia MS round bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 15 mm bore galvanized steel tubing (light grade) for protection of earth lead connection, including necessary excavation and earth work in any type of soil, dismantling and taking out old earthing plate and necessary testing complete all as shown on electrical plate No 5 of SSR Part –I (2009). |
| 85 | S&F in repair 3-layer PP-R Polypropylene random copolymer) 20 mm concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc |
| 86 | S&F in repair Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed fancy type for iron pipe or for brass ferrule and fixed of 15 mm. |
| 87 | S&F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 4.0 Core including taking down old one. |
| 88 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation of poles, etc. or for laying of cable, pier holes, etc. nexc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft & loose soil. |
| 89 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm of any type of soil. |
| 90 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point of any type of soil. |
| 91 | S&F GI Pipe 50 mm bore, 'light grade',galvanised,with all fitting;laid in trenches including taking down old one.. |
| 92 | S&F in repair High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches of size 50 mm bore. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 14 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender