Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #56553905

Tender For Repair/ Replacement Of Sunken Floor, Sinitary Fittings, Toilet Wall And Floors, Damaged Roof Incl Roof Treatment, Perimeter Wall And Allied Works At Mh Namkum And Namkum And Repair Of Damaged Mccbs, Mcb, Db, Submain Wiring, Oh Conductor, S

Issued by Statutory Bodies & Commissions/Committees · Ranchi, Jharkhand
Tender Value
31 Lakhs
Estimated cost
Bid Submission
08 Aug 2026
18 days left
EMD
62000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ranchi → Jharkhand
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Replacement Of Sunken Floor, Sinitary Fittings, Toilet Wall And Floors, Damaged Roof Incl Roof Treatment, Perimeter Wall And Allied Works At Mh Namkum And Namkum And Repair Of Damaged Mccbs, Mcb, Db, Submain Wiring, Oh Conductor, Street Light, Gate Light, Post Top Light, Security Light At Namkum Area Under Ge Ranchi

BOQ

Name of Work:- REPAIR/ REPLACEMENT OF SUNKEN FLOOR, SINITARY FITTINGS, TOILET WALL AND FLOORS, DAMAGED ROOF INCL ROOF TREATMENT, PERIMETER WALL AND ALLIED WORKS AT MH NAMKUM AND NAMKUM AND REPAIR OF DAMAGED MCCBS, MCB, DB, SUBMAIN WIRING, OH CONDUCTOR, STREET LIGHT, GATE LIGHT, POST TOP LIGHT, SECURITY LIGHT AT NAMKUM AREA UNDER GE RANCHI
Sl. No. Item Description
1Demolition of cement concrete of any description and in any position and removing the rubbish from the work site.
2Preparing surface of sunken slab and applying 15 mm thick cement plaster 1:4 cement sand mortar with integral water proofing compound both on floor and wall. The surface shall then be cured and allowed to dry then applying Epoxy Resin coating polymer modified cementitious coating like brush bond of Fosroc, Pidilite and Bostic as per manufacturer's instructions both on floor as well as on wall and sunken floor shall be filled with graded cinder complete all as specified.(IWPC will be paid separately)
3PCC 1:7:12 type using 40 to 60 mm thick brick aggregate as in filling of sunken portion completed all as specified.
425mm thick PCC 1:2:4 type B0 using12.5 mm graded stone aggregate as in sunken floor complete as specified and directed.
5M&L for 40 mm thick PCC (1:2:4) type B-1 using 20 mm graded stone aggregate with WPC as in sunken portion and making adequate slope toward spout pipe complete all as specified and as directed. NOTE: - Water Proofing Compound shall be measured and paid separately
6M&L for rendering 15 mm thick on concrete or brick surface in CM (1:3) mixed with WPC as per manufacturer instructions and finishes surfaces even and smooth with out using extra cement.Note - WPC will be measured and paid separtely
7M&L for applying two coats evenly a tack coat of hot air blown bitumen of grade 85/25 @ 1.50 Kg per sqm per coat (one coat over plaster and one coat on polythene film) including cleaning of surface over polythene film complete all as specified and as directed
8M&L for polythene film black 200 micron thick laid in floor, vertical surface etc complete all as specified and directed.
9M&L for PCC (1:5:10) Type E-2 using 40mm graded brick aggregate as in sunken portion complete all as specified and directed.
10Taking down complete existing treatment of roof/ parapet , Mud puska on roof /parrapet including plastering, brick tiles, stone slabs and leeping any thickness including removal etc complete .
11Scarpping surfaces of roof by wire brushing and removing all loose dust and cleaning and washing down the surfaces with water complete all as directed.
12M&L Brushing neat cement slurry (3 Kg of cement per Sq M) mixed with chemical compound in the proportion, chemical compound SUPER LATEX of DR FIXIT of PIDILITE INDUSTRIES LTD, water & cement (1:4:7) or SBR LATEX of STP LTD or other equivalent as per manufacture instructions for bonding of old concrete surface to new concrete all as specified & directed complete.
13M&L Rendering 10 mm thick in cement mortar 1:4 on concrete / brick surfaces with liquid water proofing compound @ 200 ml/50 kg per bag of cement or as per manufacturar instruction finished even and smooth without using extra cement over roof / sunken slab /wall complete all as specified and directed.
14M&L for Water proofing treatment on \\"Not Approachable /inaccessible roof\\" surface (Horizontal & Vertical surfaces) in following sequence through manufacturer / authorized applicator of the manufacturer all as specified and directed complete. (i) Properly cleaning and drying concrete surfaces. (ii) Applying a coat of oxidised bitumen based solvent primer @ 0.3 Kg / Sqm. (iii) Applying evenly tack coat of industrial 85/25 grade @ 1.2 kg/ Sqm. (iv) Laying unrolled over the bitumen coated surface, polymeric water proofing membrane Hyperplas standard wt not less than 3kg /Sqm with 100 mm over laps shall be sealed by flame as per manufacturers instruction. (v) Applying a coat of bitiminous aluminium paint @ 100 Gram / Sq M over & incl a coat of hot air blown grade bitumen of grade 85/25 @ 1.2 Kg/ Sqm duly sanded over polymeric membrane complete.
15M&L for screed bed or bedding layer of mortar 20 mm thick for laying floor finishes in CM 1:4 for fixing tiles. (Note :- Screed bed shall be mixed with water proofing compound)
16M&L for 20 mm thick machine cut & polished cement concrete tiles factory made with grey cement without pigment of size 250mm x 250 mm laid in neat cement slurry over screed bed and tiles properly laid with 3 mm wide joints filled with FEVIMATE TG of Dr Fixit or tile glue or as per manufacturer instructions complete all as specified and directed.
17M&L for two coats of bituminous based aluminum paint on APP membrane all as specified and directed.
18S&F in repair 500 Ltrs capacity rotational moulded polythene water storage tanks in two layer cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt-I
19S&F in repair 1000 Ltrs capacity rotational moulded polythene water storage tanks in two layer cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt-I
20S&F in repair 2000 Ltrs capacity rotational moulded polythene water storage tanks in two layer cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt-I
21S&F PVC ball valve 20mm dia with epoxy coateed aluminium rod and high density ball (minium weight 210 gms) complete as directed .
22Cleaning and removing all scale and dirt etc by using bleaching powder from water tank and from mouth of circulating pipe,etc Capacity of tank Capacity of tank exc 250 litres & n exc 500 litres
23Cleaning and removing all scale and dirt etc by using bleaching powder from water tank and from mouth of circulating pipe,etc Capacity of tank Capacity of tank exc 500 litres & n exc 1000 litres
24Cleaning and removing all scale and dirt etc by using bleaching powder from water tank and from mouth of circulating pipe,etc Capacity of tank Capacity of tank exc 1000litres & n exc 2000 litres
25Dismantling AC/ CGI/ translucent ( corrugated, semicorrugated,etc), as in roof covering complete.
26M&L 6 mm thick asbestos cement, corrugated or semi corrugated sheets in roof, walls etc fixed with L-T type or J-type or cranked hook bolts etc complete all as specified and directed by EIC .
27Description all per above ser item No 26 but exept sheet
28S&F Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, Chhaja, etc fixed with self tapping screws as specified.
29S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
30Dismantling of timber scantling 40 Sqcm and over in section in any position complete.
31M&L roof trusses (framed ), trussed, purlins, rails & fastening and heavy bracket framing (beam, tee, angle, channel, flat, etc) incl distance pieces, cleats , holdfast etc complete all as spd & directed.
32Dismantling of wall/ceiling boards (fibre, pulp, insulation, etc) of any type including cover fillets.
33M&L for providing aluminium snap Grid frame work for false ceiling with of size 605X605 mm ,using Main and cross tee of size 36.5mmX25mmX1.4mm,weighing 0.24 kg/RM and 23.5mmX26.4mmX1.4mm weighing 0.191Kg/RM respectively. the snap grid shall be supported at end all along the wall with aluminium anodised angle of size 40mmX25mmX2mm weighing 0.36Kg/RM. The snap grid shall be fixed to ceiling supporting hangers consisting of 2mm dia MS wire/GI wire, J bolts, nuts and washers as per manufacturer's complete all as specified.
34M&L 4mm thick non asbestos fibre designer cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws.
35Demolition of brick work build in cement mortar including all quoins, arches, pillars, complete.
36M&L brick work with sub class 'B' brick straight or curved on plan exc 6m means radius build in cement mortar 1:6
37Taking down cement plaster on wall of any description incl racking out joints hacking for key and scrubbing down with water complete.
38M & L rendering 10 mm thick in cement mortar 1:4 on Wall/chajjas/lintel etc and finished even and fair without using extra cement in patches.
39M & L rendering 15 mm thick in CM 1:6 in on surface of walls and finished even and fair (without using extra cement) in patches.
40M & L preparation of new plastered surfaces of walls/chajja/lintel and applying two coats of cement based paint white or tinted over a coat of alkali resistant primer complete as specified and directed.
41M&L Preparing New plastered surfaces, priming plastered and other surfaces with alkali resistant primer and applying two coats of oil bound distemper of any shade on walls surfaces
42Material & labour for preparation of new or previously untreated steel surface of any description over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
43Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) complete.
44M&L for joint free non skid coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc over & including 15mm thick screed bed in CM 1:4, set & jointed in neat cement slurry and pointed with white or coloured cement to match complete
45M&L coloured ceramic glazed tiles 450x300x7mm thick as in dado/skirting etc including 10 mm thick rendering in CM 1:3, set & jointed in neat cement slurry & pointed in white or coloured cement slurry & pointed in white or coloured cement.
46Taking up or steel tubing & connections including cleaning for refixing bore of pipe 15mm etc complete all as specified and directed
47Taking up or steel tubing & connections including cleaning for refixing bore of pipe 20mm etc complete all as specified and directed
48S&F tubes medium grade galvanised with all fittings & fixed complete to walls & ceiling or laid in floors 15mm bore etc complete all as specified and directed
49S&F tubes medium grade galvanised with all fittings & fixed complete to walls & ceiling or laid in floors 20mm bore etc complete all as specified and directed
50Refixing old galvanised steel tubes & connections on wall 15 mm bore complete all as specified and directed .
51Refixing old galvanised steel tubes & connections on wall 20 mm bore complete all as specified and directed .
52Supplying and laying of CPVC pipes 20 mm dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all necessary fittings complete all as specified.
53S&F in repair 20mm Stop valve of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/ 20mm92gms) as per specidied and directed
54Taking down chowkats or frame with shutters (without taking off shutters from the frames) n. Exc 1.5 Sqm each
55Description all per above ser item No 54 but exc1.5 Sqm but n.exc. 4 Sqm.
56S & F factory made single extruded WPC (Wood polymer composite) solid door/window/ceosetory windows & other frames/chowkhats of size 50 x 100 mm comprising of virgin PVC ploymer of K value 58-60 (suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strenght of 2200 N (Face) & 1100N (Edge), minimum compressive strength of 58N/mm2, modules of elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixede in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-charge. (M.S. hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerence in dimension i.e. depth and width of profile shall be acceptable. variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
57S&F factory made solid PVC Moulded door shutter(with particle board core), 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick moulded PVC sheet on front face and 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing .
58Supply & fix mild steel butt hinges 100mm size medium weight, cold rolled complete all as specified and directed.
59Supply & fix 125mm size aluminium alloy handles cast type anodized complete all as specified and directed.
60Supply & fix 150mm long aluminium anodized barrel tower bolt of extruded section complete all as specified and directed.
61S&F anodised aluminium window/partition and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised alumnium snap beading, screws etc. complete all as specified
62S&F in repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.18 mm and fixed with stainless steel wire staples
63Supply & fix 4mm thick , figured glass,pin head type ordinary quality glazing with oil putty or fixed with wooden beads or in steel windows/aluminium frmae in square n.exc. 0.50sqm each pane
64S&F in repair Vitreous china wash down water closet pan ( pedestal pattern), white (excluding fixing bolt, flushing cistern and flush pipe) but including P or S trap, sheet cover of white colour all as directed and specified.
65S&F in repair Vitreous China urinal,Half stall type White(excluding waste Pipe) complete all as specified and directed
66S&F in repair Vitreous china urinal partition white of size 310x700 mm terminating about 40cm above floor line all as spd and directed
67S&F in repair vitreous china squatting pan, Orrissa pattern size 580x440mm white with PVC 'P' or 'S' trap with integral foot rest of any pattern incl connection to trap & to flushing pipe, antisyphonage pipe etc making good to floor complete.
68S&F in repair vitreous china wash hand basin, white, flat back, size 550x400 mm incl chain and plug and porcelain stopper, brackets, waste pipe incl cutting for and pinning in ends of brackets or erecting stand including dismantling
69Supply & fix in repairs PVC low level flushing cistern of 10 ltrs capacity, ISI Marked, white, symphonic action type with inlet, ball valve, float and handle including brackets and PVC flush pipe of 32 mm bore, suitable for low level cistern complete all as specified & directed.
70Supply & fix in reapir 15mm bore Angular Stop valve cast copper alloy fancy type chromium plated, complete all as specified and directed.
71Description all per above ser item No 70 but two way angle cock
72Supply & fix in repair wall mixer brass chromium plated for mixing hot and cold water screwed for iron pipe suitable for 15mm bore pipes complete all as specified and directed.
73Supply & fix in repairs brass chromium plated Central hole basin mixer for mixing hot and cold water screwed for iron pipe suitable for 15 mm bore pipes including pvc connection etc complete all as specified & directed.
74Supply & fix in repairs chromium plated shower roses with swivel joints of 125mm size complete all as specified & directed.
75Supply & fix in repairs PVC connections of 450mm long of PRYAG Make suitable for 15mm dia iron pipe including PTMT nuts complete all as specified & directed.
76S&F grating doom 100mm dia of PTMT (Minimum weight 25gms).
77Supply and fixing in repair PVC waste pipes of 40/32mm bore suitable for wash hand basins/sinks complete all as specified & directed.
78Supply & fix in repair for 600 x 450 mm beveled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial ply wood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed .
79S&F in repairs 15 mm bore concealed stop cock, chromium plated, cast copper alloy, screwed down with crutch or butterfly handle screwed both ends, as in repair including flench complete all as specified & directed.
80Supply & fixing in reapir MS tubular towel rail, 60 cm long, 20mm bore, chromium plated complete all as specified & directed.
81Supply & fix in repairs pillar taps, fancy type cast copper alloy with capstan heads, chromium plated, screwed down, high pressure with or without lettered “hot” or “cold” with long screwed shanks and fly nut screwed for iron pipe of 15mm bore, complete all as specified & directed.
82Supply & fix in repairs Fancy type bib taps cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe of 15mm bore, complete all as specified & directed.
83S&F in repair,Toilet paper holder of with flat recessed type stainless steel fixed to walls with chromium plated(CP) brass screws complete all as specified and directed
84S&F in repairs Health faucet(ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 meter long flexible tube and ABS wall hook including making connections and fixed in position complete in complete all as specified & directed.
85Demolition and breaking of drain pipes of 110/75mm size etc complete all as specified & directed.
86Supply and fix PVC Pipes single socketed in any length with rubber ring joints, fixed to walls, laid under floors etc. 110 mm bore as in waste and rain water pipes complete all as specified & directed.
87Supply and fix PVC bends 110mm bore, any radius complete all as specified & directed.(ISI Marked)
88M&L PVC(SWR) Tee of radius 110mm dia.
89S & F PVC(SWR) vent cowel of 110mm dia.
90S&F PVC (SWR) pipes single socketed in any length with rubber ring joints using solvent adhesives fixed to walls with brackets etc of 75 mm dia
91S&F 75 mm bore PVC floor trap with 75mm dia grating including jointing to waste pipe, all as specified
92M&L PVC (SWR) bend of radius 75mm dia.
93M&L 15mm thick rendering on fair faces of bk /concrete surfaces in cm (1:4), finished even and smooth (Without using extra cement ) complete all as specified and directed.including scafolding up to G+3 story bldg, etc complete.complete.
94M&L finishing walls on newly prepared surfaces with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed.including scafolding up to G+3 story bldg, etc complete.complete
95M&L two coat of cement paint on Complete removal of existing old surfaces on wall , etc complete all as specified and directed.
96M&L finishing walls on Complete removal of old prepared surfaces with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed. including scafolding up to G+3 story bldg, etc complete.complete.
97M&L for preparation of old painted steel surface of any description , over 10 cm width or girth not otherwise described and applying one coat of synthitic enamel paint white or tinted all as directed.
98Taking down carefully exising unserviceable copper/aluminium point wiring (light, fan, socket or power), complete (fitting such as switches,ceiling rose, pendent, regulators etc) removing material to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately and making dood disturbed surfaces of wall, floor etc. complete all as specified and as directed.
99Taking down of old unserviceable sub main wiring of any type complete all as specified and as directed.
100Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes all as specified.
101M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC casing caping including all accessories etc, heavy duty ISI marked, with mild steel sunken boxes 1.6 mm thick, 60 mm deep with earth dolly duly, covered with hylem sheet cover 3 mm thick, ISI marked suitable for fixing of switches, fan regulators and sockets including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-(Contractor should make good even distributed wall/surface as before.)
102(a) One light point controlled by one, one way switch 5 Amps
103(b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
104(c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
105(e) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
106Description all as per item No 101 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly.
107M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC casing caping/conduit including all accessories etc, heavy duty ISI marked, with GI sunken /surface boxes 1.2 mm thick, 60 mm deep with earth dolly duly as per site requirment , covered with modular white cover plate with frame suitable for modular switches, or PVC surface mounted modular box, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :- (Note- Modular cover plate and base plate of any module with all fittings are included in point wiring.) Contractor should make good even distributed wall/surface as before.
108(a) One light point controlled by one, one way switch 5 Amps
109(b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
110(c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
111(d) One bell point controlled by one, bell switch 5 Amps
112(e) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
113Description all as per item No 103 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly.
114S & F for Bell push modular 6 Amps single module complete all as specified.
115Suply and fix for Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed
116S & F ceiling fan regulator socketed, step type, flush type heavy duty suitable to work on 230 volts AC supply including removal of old unserviceable one complete all as specified.
117S & F for Lamp holder, PVC body suitable for batten fitting completes all as specified.
118S & F for Ceiling rose, surface Bakelite suitable ISI marked for batten fitting complete all as specified
119S & F for Switch piano flush type, single pole, one way, and 6 Amp complete all as specified.
120S & F for Socket outlet multipurpose having provision for 3 pin, 6 Amp and 2 pin, 6 Amp, piano flush type complete all as specified.
121S&F in replacement of switch socket combinations flush 5 Amp 5 pin competeI ,ISI marked
122S&F switch socket combination 2 in 1, 3 pin, 15 amp multipurpose, flush type, all as specified and as directed
123M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 4.0 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size concealed in wall etc including one run of PVC insulated 4 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 4.0 sqmm cable,one run of 4 sqmm cable and one run of PVC casing caping will be measured as one unit
124M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC casing caping will be measured as one unit
125S & F for sheet metal enclosure MCB DB TPN 4 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. Make : Schneider, Havells, ABB.
126S & F for sheet metal enclosure MCB DB VTPN 4 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.Make : Schneider, Havells, ABB.
127S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.Make : Schneider, Havells, ABB.
128S & F for sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.Make : Schneider, Havells, ABB.
129S & F MCCB TPN 415 volts 25 KA suitable for fixing on DB of capacity 100 Amps with extended terminals complete all as specified.
130S & F for MCB tripple pole and neutral rated capacity 63 Amps, 415 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed.
131S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed.
132S & F for MCB Single pole and neutral rated capacity 40-63 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed.
133S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed.
134S & F for Modular Switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified.
135S & F for Modular Switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified.
136S & F for Modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified.
137S & F for Modular Socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified.
138S & F for modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed.
139Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 1.5 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed.
140Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 2.5 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed.
141Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 4 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed.
142M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated frlshH cable with stranded copper conductor of size 4.0 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty PVC casing caping of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size in wall etc including one run of PVC insulated 4 Sqmm (nominal area) stranded copper conductor frlshH cable as earth wire complete all as specified and as directed. Note:- Two runs of 4.0 sqmm cable,one run of 4 sqmm cable and one run of PVC casing caping will be measured as one unit
143M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated frlshH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into PVC non metallic rigid heavy duty PVC casing caping of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor frlshH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC casing caping will be measured as one unit
144Excavation in trenches not exc 1.50 Metre wide and not exc 1.50 Metre depth for laying of UG Cable getting out in Soft/Loose Soil, complete all as specified and as directed.
145Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils, complete all as specified and as directed.
146Removing Surplus soil to a distance not exc 50.00 Metre away and depositing where directed at a level not exc 1.50 Metre above the Starting Point, complete all as specified and as directed.
147M & L Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 18 cm thickness, complete all as specified and as directed. Note : For the purpose of Payment, Punned thickness of Sand Cushioning only shall be measured and paid.
148S & F Sub-Class ‘B’ Brick, well burnt, laid breadth wise along the length of Cable laid in trenches over Sand Cushion laid for UG Cable Protection, complete all as specified and as directed.
149S & F Galvanised Iron Pipe light grade as in protection of UG Cable laid in trenches including necessary MS clamp, nuts, bolts and painting of following sizes complete all as specified and as directed.
150(a) 50 mm dia
151(b) 40 mm dia
152S & F in replacement of for Energy saving new generation environmental friendly LED street light luminaire with long life versatile pressure die-cast housing with toughened glass and individual LEDs with secondary optics and IP 66 protection with high power LEDs as light source and electronic driver of capacity 90 watts with pre wired and necessary mounting arrangement and provision of 4 sq mm twin core copper conductor cable multi stranded from fitting to junction box including necessary GI pipe medium braket of required dia 1.5 mtr long bend to required shape with suitable with MS clamps made out of flat iron of size 40 x 6 mm - 02 sets, bolt & nuts and taking down old unserviceable Street Light Fitting form Electric Pole of any description complete all as directed by Engineer- in-charge.
153Supply & Fixing or Passing through pipe, XLPE insulated, Armoured, Electric power UG cable (Heavy duty) with aluminium conductor, 1100 volts grade, nominal cross sectional area 6 sqmm 2 core including Brass compression cable gland, terminal lug etc and testing complete all as specefied and as directed
154Supply & Fixing or Passing through pipe, XLPE insulated, Armoured, Electric power UG cable (Heavy duty) with aluminium conductor, 1100 volts grade, nominal cross sectional area 10 sqmm 2 core including Brass compression cable gland, terminal lug etc and testing complete all as specefied and as directed
155S&F in replacement of LED Post top / Gate light 1x40 W decorative type, 360° indirect light including fixing with suitable size GI pipe as required on the top of gate pillar, control by suitable MCBs as per direction and wiring complete all as specified and directed. Make:- Crompton Cat Ref No LPTO-40-CDL -M or its equivalent in Phillips/Havells
156S&F in replacement of Garden Light/ Bollards 10 W IP 65 are made of extruded Aluminium, profiles with cast aluminium base,opal PC diffusers with integrated LED and driver fixed in proper cemented base complete all as specified and directed. Make:- Crompton Cat Ref No LBLSN-10-CDL or its equivalent in Phillips/Havells
157Supply and fixing of 50 W LED façade light fitting of with LED driver, mounting bracket, internal wiring, connector strip, cable glands and all connected accessories including dismantling of defective fitting, connection, testing and commissioning complete all as specified and directed. Make :-Crompton, Havells, Philips
158S & F in replacement of Junction Box for Street Lights of size 250 x 300 x 150 mm made out of CRCA sheet 2 mm thick totally enclosed, dust and vermin proof, rain protected slanted roof top, door pasted with rubber gasket, water tight IP 42 protection single leaf shutter in front having proper locking arrangements, and painted with powder coating paint and suitable size of \\"connectwell\\" stud teriminal (provision for socket bolting)- 05 Nos suitable for 415 volts, 50 Hz, 3 phase 4 wire internal wiring system including MCB SP 06 amps- 01 No and mounted on security light pole with suitable clamp made out of MS flat of size 32 mm x 6 mm thick bend to required shape and suitable size of nuts, bolts including removal of existing unsv one of any type complete all as specified and directed.
159M & L in replacement for Street Light Fitting Bracket made out from GI Pipe 40 mm bore (dia), medium grade 1.50 metre long, bent to required shape and fixing to Poles with and including Clamp sets suitable for tubular pole made out of MS flat iron of size 40 mm x 6 mm thick, Nuts, Bolts as required duly painted with Two Coats of Aluminum Paint over a coat of Red Oxide Zinc Chrome Primer including taking down old unserviceable bracket, comlete all as specified and as directed.Note : Cost of Mild Steel Clamp, Nuts, Bolts and painting is deemd to be included in the quoted Unit Rate.
160S & F in replacement of for Energy saving new generation environmental friendly LED street light luminaire with long life versatile pressure die-cast housing with toughened glass and individual LEDs with secondary optics and IP 66 protection with high power LEDs as light source and electronic driver of capacity 90 watts with pre wired and necessary mounting arrangement and provision of 4 sq mm twin core copper conductor cable multi stranded from fitting to junction box including necessary GI pipe medium braket of required dia 1.5 mtr long bend to required shape with suitable with MS clamps made out of flat iron of size 40 x 6 mm - 02 sets, bolt & nuts and taking down old unserviceable Street Light Fitting form Electric Pole of any description complete all as directed by Engineer- in-charge.
161S&F in replacement driver for LED energy saving & enviornment area light fitting > 90 watts security light with active power factor correction (APFC) electronic driver. LED driver 90 Watt with operating voltage between 100-270 V of existing specifications & make complete all as specified and directed by Engineer-in-Charge.
162Description all per above ser item No 150 but for LED Street light 60 watt
163Supply and fixing in replacement of LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified & directed.
164Taking down old unserviceable and Supply and fixing connecting and testing (in replacement) time switch panel box size 400mm x 350mm x170 mm dust and vermin proof made of 16 gauge MS sheet factory made duly painted with two coats of synthetic enamel paint recommended colour over a coat of red oxide primer and mounted inside the following .Location-wise photos be attached alongwith the bills..Note:- Time switch pannel box shall be fixed on one pole/wall in feeder pillar box with flat iron clamp 40x6 mm or other suitable fixing arrangement complete all as specified and directed. MCB triple pole 32 Amps 230 volt-01 No Analog electro mechanical time switch 24 hours with minimum setting 30 minutes for daily working contact rating 16 Amps,240 volts,AC with initial charging battery backup having supply and reserve failure upto 150 Amp hours and coil voltage 415 volts AC contactor ,3 pole,ML-2,415 Volts,50 HzInternal wiring with pvc insulated stranded copper conductor of suitable size and making electric connection -01 No.By pass MCB single pole ,32/40 Amps,230 volts-01 No.Note:- Time switch panel box shall be fixed on one pole/wall in feeder pillar box with flat iron clamp 40x6 mm or other suitable fixing arrangement complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56553905
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 31 Lakhs
LAST DATE 08-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Replacement Of Sunken Floor, Sinitary Fittings, Toilet Wall And Floors, Damaged Roof Incl Roof Treatment, Perimeter Wall And Allied Works At Mh Namkum And Namkum And Repair Of Damaged Mccbs, Mcb, Db, Submain Wiring, Oh Conductor, Street Light, Gate Light, Post Top Light, Security Light At Namkum Area Under Ge Ranchi
Basic Detail
Tender No 8200/1729/E8
Bidding Type Tender
Location
City Ranchi
State Jharkhand
Key Dates
Publish Date 18 Jul 2026
Submission Date 08 Aug 2026
Open Date 15 Aug 2026
Finance
Tender Value 31 Lakhs
Tender Fee 500
EMD 62000
Exemption Available
Document List
BOQ_873225.xls
fdac42f7-f41a-4b3d-a71c-a2ba9b102d91.html
Tender1729.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Aug 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 25 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_873225.xls

html

fdac42f7-f41a-4b3d-a71c-a2ba9b102d91.html

pdf

Tender1729.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender