Defence Statutory Bodies & Commissions/Committees Closing in 25 days TDR #56553895

Tender For Certain Civil Works Of Repair/Maint Nature For Dg Sets Cable Trenches, Duct/Trench Covers, Servicing/Painting To Shutters Etc Including E/M Works Like Repair/Replacement Of Ats, Switchgears, Earthing Canopy Etc At Naval Station Karanja

Issued by Statutory Bodies & Commissions/Committees · Raigad, Maharashtra
Tender Value
84.64 Lakhs
Estimated cost
Bid Submission
15 Aug 2026
25 days left
EMD
1.52 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Raigad → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Certain Civil Works Of Repair/Maint Nature For Dg Sets Cable Trenches, Duct/Trench Covers, Servicing/Painting To Shutters Etc Including E/M Works Like Repair/Replacement Of Ats, Switchgears, Earthing Canopy Etc At Naval Station Karanja

BOQ

Name of Work:- CERTAIN CIVIL WORKS OF REPAIR/MAINT NATURE FOR DG SETS CABLE TRENCHES, DUCT/TRENCH COVERS, SERVICING/PAINTING TO SHUTTERS ETC INCLUDING E/M WORKS LIKE REPAIR/REPLACEMENT OF ATS, SWITCHGEARS, EARTHING CANOPY ETC AT NAVAL STATION KARANJA
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CWE KARANJA NAME OF WORK: CERTAIN CIVIL WORKS OF REPAIR/MAINT NATURE FOR DG SETS CABLE TRENCHES, DUCT/TRENCH COVERS, SERVICING/PAINTING TO SHUTTERS ETC INCLUDING E/M WORKS LIKE REPAIR/REPLACEMENT OF ATS, SWITCHGEARS, EARTHING CANOPY ETC AT NAVAL STATION KARANJA CONTRACT AGREEMENT: CWE KJ(K)- OF 2026 - 2027 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item of Work Item Code / Make Quantity Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT (in Words)
2Material and labour for carrying out repairs to AMF panel of 15 KVA to 200 KVA DG set at various installation inclduing study, tracing out circuit, testing, replacing all defective parts, rewinding existing power and control wiring with same cables including testing and commissioning complete all as specified and as directed. (Note: Spares like Volt meter, CT, power contactor required for repair will be measured and paid seperately under relevant items.
3Material and Labour for dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made LT cubical double door panel with roof canopy, outdoor type, of Suitable to accomodate the following accessories made out of CRCA sheet 3 MM thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle. Inner cubicle should be made out of 2 MM thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase 4 wire fully compartmentalised with single door system for each compartment. Outer cubicle having both sides door openable and should be provided with suitable louvers for ventilation. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall withstand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp., shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle should be inclusive of following : The cubicle should be inclusive of following :
4(A) INCOMING -(i) On-load Changeover Switch I-O-II open execution, 4 pole - 630 Amps, - 01 No(ii) MCCB -DPX3 630 thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 630 Amps – 01 No.
5(B) OUTGOING-(i) MCCB -DPX3 250 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 250 Amps – 01 No.(ii) MCCB -DPX3 160 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 160 Amps – 01 No.(iii) MCCB -DPX3 160 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 125 Amps – 02 No.(iv) MCCB -DPX3 160 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 100 Amps – 06 No.(v) Multi function meter having LCD Display, 96 x 96 sq.mm -01 No.(vi) Current transformer of suitable ratio, Accuracy - 5VA, Class - 1. (vii) LED INDICATORS RIBBED LENS WITH TRIMMED COLLAR - Red, Yellow and Blue - 1 Each, (viii) Aluminium bus bar of Rating 2000 Amp R-Y-B phases and Neutral.(ix) Base frame for cubical mounting made out of 40x40x6mm equal angle iron duly painted.(x) Foundation for the panel should provided with PCC 1:4:6 at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for I/C and O/G cables.
6Material and Labour for dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made LT cubical double door panel with roof canopy, outdoor type, of Suitable to accomodate the following accessories made out of CRCA sheet 3 MM thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle. Inner cubicle should be made out of 2 MM thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase 4 wire fully compartmentalised with single door system for each compartment. Outer cubicle having both sides door openable and should be provided with suitable louvers for ventilation. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall withstand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp., shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle should be inclusive of following : The cubicle should be inclusive of following :
7(A) INCOMING -i) On-load Changeover Switch I-O-II open execution, 4 pole - 630 Amps, - 01 No(ii) MCCB -DPX3 630 thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 630 Amps – 01 No.
8(B) OUTGOING-(i) MCCB -DPX3 250 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 250 Amps – 01 No.(ii) MCCB -DPX3 160 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 100 Amps – 07 No.(iii) MCCB -DPX3 160 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 63 Amps – 02 No.(iv) Multi function meter having LCD Display, 96 x 96 sq.mm -01 No(v) Current transformer of suitable ratio, Accuracy - 5VA, Class - 1. (vi) LED INDICATORS RIBBED LENS WITH TRIMMED COLLAR - Red, Yellow and Blue - 1 Each, (vii) Aluminium bus bar of Rating 1000 Amp R-Y-B phases and Neutral.(viii) Base frame for cubical mounting made out of 40x40x6mm equal angle iron duly painted.(ix) Foundation for the panel should provided with PCC 1:4:6 at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for I/C and O/G cables.
9Supply & Fixing,Laying, jointing, connecting & testing XLPE/PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminum conductor in trenches / ducts of following sizes incl taking out cable all as specified and directed
103.5 core 70 Sqmm
113.5 core 185 Sqmm
123.5 core 240 Sqmm
133.5 core 95 Sqmm
143.5 core 120 Sqmm
153.5 core 150 Sqmm
16Excavation in trenches for not exc 1.5 mtr wide and not exc 1.5 mtr depth and getting out in Hard/dense soil including taking out faulty cable/cable covers and GI pipe complete all as specified and directed.
17Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm complete all as specified & directed.
18Removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5m above the Starting point.
19Dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made, LT cubical, double door panel with roof canopy, outdoor type suitable to accomodate the following accessories made out of CRCA sheet 3mm thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle, Inner cubicle should be made out of 2mm thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase, 4 wire fully compartmentalised with single door system for each compartment. Outer cubicle having both sides door openable and should be provided with suitable louvers for ventilation. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall with stand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp, shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle should be inclusive of following : The cubicle should be inclusive of following :
20(A) INCOMING -(i) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 630 Amps – 01 No.(B) OUTGOING-(i) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 250 Amps – 02 Nos.(ii) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 200 Amps – 02 Nos.(iii) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 160 Amps – 02 Nos.(iv) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 125 Amps – 02 Nos.(v) Multi function meter having LCD Display, 96 x 96 sq.mm -01 No(vi) Current transformer of suitable ratio, Accuracy - 5VA, Class - 1. (vii) LED INDICATORS RIBBED LENS WITH TRIMMED COLLAR - Red, Yellow and Blue - 1 Each,(viii) Aluminium bus bar of Rating 1000 Amp R-Y-B phases and Neutral.(ix) Base frame for cubical mounting made out of 40mm x 40mm x 6mm equal angle iron duly painted.(x) Foundation for the panel should provided with PCC 1:4:8 using 40 mm graded stone aggregates at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for I/C and O/G cables.
21Dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made, LT cubical, double door panel with roof canopy, outdoor type suitable to accomodate the following accessories made out of CRCA sheet 3mm thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle, Inner cubicle should be made out of 2mm thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase, 4 wire fully compartmentalised with single door system for each compartment. Outer cubicle having both sides door openable and should be provided with suitable louvers for ventilation. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall with stand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp, shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle should be inclusive of following : The cubicle should be inclusive of following :
22(A) INCOMING -(i) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 630 Amps – 01 No.(B) OUTGOING-(i) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 400 Amps – 01 No.(ii) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 320 Amps – 01 No.(iii) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 250 Amps – 01 No.(iv) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 100 Amps – 01 No.(v) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 63 Amps – 01 No.(iv) Multi function meter having LCD Display, 96 x 96 sq.mm - 01 No(v) Current transformer of suitable ratio, Accuracy - 5VA, Class 1 (vi) LED INDICATORS RIBBED LENS WITH TRIMMED COLLAR - Red, Yellow and Blue - 1 Each(vii) Aluminium bus bar of Rating1000 Amp R-Y-B phases and Neutral.(viii) Base frame for cubical mounting made out of 40mm x 40mm x 6mm equal angle iron duly painted.(ix) Foundation for the panel should provided with PCC 1:4:8 using 40mm graded stone aggreagrs at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for I/C and O/G cables.
23Dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made, LT cubical, double door panel with roof canopy, outdoor type suitable to accomodate the following accessories made out of CRCA sheet 3mm thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle, Inner cubicle should be made out of 2mm thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase, 4 wire fully compartmentalised with single door system for each compartment. Outer cubicle having both sides door openable and should be provided with suitable louvers for ventilation. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall with stand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp, shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle should be inclusive of following : The cubicle should be inclusive of following :
24(A) INCOMING -(i) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 250 Amps – 01 No.(B) OUTGOING-(i) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 100 Amps – 02 Nos.(ii) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 63 Amps – 06 Nos.(iii) Multi function meter having LCD Display, 96 x 96 sq.mm -01 No(iv) Current transformer of suitable ratio, Accuracy - 5VA, Class - 1. (v) LED INDICATORS RIBBED LENS WITH TRIMMED COLLAR - Red, Yellow and Blue - 1 Each, (vi) Aluminium bus bar of Rating 400 Amp R-Y-B phases and Neutral.(vii) Base frame for cubical mounting made out of 40mm x 40mm x 6mm equal angle iron duly painted.(viii) Foundation for the panel should provided with PCC 1:4:6 at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for I/C and O/G cables. (viii) Foundation for the panel should provided with PCC 1:4:8 using 40 mm graded stone aggregates at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for I/C and O/G cables.
25Dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made, LT cubical, double door panel with roof canopy, outdoor type suitable to accomodate the following accessories made out of CRCA sheet 3mm thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle, Inner cubicle should be made out of 2mm thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase, 4 wire fully compartmentalised with single door system for each compartment. Outer cubicle having both sides door openable and should be provided with suitable louvers for ventilation. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall with stand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp, shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle should be inclusive of following : The cubicle should be inclusive of following :
26(A) INCOMING - (i) On-load Changeover Switch I-O-II open execution, 4 pole - 100 Amps - 01 No(ii) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 100 Amps – 01 No.(B) OUTGOING-(i) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 63 Amps – 02 Nos.(ii) Multi function meter having LCD Display, 96 x 96 sq.mm -01 No(iii) Current transformer of suitable ratio, Accuracy - 5VA, Class - 1. (iv) LED INDICATORS RIBBED LENS WITH TRIMMED COLLAR - Red, Yellow and Blue - 1 Each, (v) Aluminium bus bar of Rating 200 Amp R-Y-B phases and Neutral.(vi) Base frame for cubical mounting made out of 40mm x 40mm x 6mm equal angle iron duly painted.(vii) Foundation for the panel should provided with PCC 1:4:8 using 40 mm graded stone aggregates at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for I/C and O/G cables.
27Dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made, LT cubical, double door panel with roof canopy, outdoor type suitable to accomodate the following accessories made out of CRCA sheet 3mm thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle, Inner cubicle should be made out of 2mm thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase, 4 wire fully compartmentalised with single door system for each compartment. Outer cubicle having both sides door openable and should be provided with suitable louvers for ventilation. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall with stand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp, shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle should be inclusive of following : The cubicle should be inclusive of following :u in all MCCBs with extended Rotary Handle. The cubicle should be inclusive of following : The cubicle should be inclusive of following :
28(A) INCOMING -(i) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 200 Amps – 01 No.(B) OUTGOING-(i) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 100 Amps – 01 No.(ii) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 63 Amps – 03 Nos.(iii) Multi function meter having LCD Display, 96 x 96 sq.mm -01 No(iv) Current transformer of suitable ratio, Accuracy - 5VA, Class - 1. (v) LED INDICATORS RIBBED LENS WITH TRIMMED COLLAR - Red, Yellow and Blue - 1 Each,(vi) Aluminium bus bar of Rating 300 Amp R-Y-B phases and Neutral.(vii) Base frame for cubical mounting made out of 40x40x6mm equal angle iron duly painted.(viii) Foundation for the panel should provided with PCC 1:4:8 using 40 mm graded stone aggregates at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for I/C and O/G cables.
29Material and Labour for earthing with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32mm x 6 mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4) type B1 using (20 mm graded stone aggregate), mild steel angle iron frame made out of MS angle iron of size 40x40x6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade pipe for watering, 40 mm dia light grade GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-1(2009) connected to earthing test point including testing on completion and taking down old u/s materials complete all as specified and directed. NOTE: (i) The earth chamber shall be constructed 0.50m away from the edge of earth pit and the cost of the same is deemed to be included in quoted unit rate. (ii) GI Strip and protection pipe upto 7.5m is deemed to be included in the quoted unit rate. (iii) GI watering pipe upto 1.2m s deemed to be included in the quoted unit rate.
30Supply and Install , testing and commissioning the Onload change over switch front handle type of capacity 630 Amp 4pole 415 volts with sheet steel enclosure of made by 3.2mm thick CRCA sheet outdoot type along with pedestal to grout in PCC 1:3:6 type C2 of any thickness foundation and Indication lamps of R, Y, B for three phase supply indication and all as spcified and directed.
31Supply and Install , testing and commissioning the Onload change over switch front handle type of capacity 400 Amp 4pole 415 volts with sheet steel enclosure of made by 3.2mm thick CRCA sheet outdoot type along with pedestal to grout in PCC 1:3:6 type C2 of any thickness foundation and Indication lamps of R, Y, B for three phase supply indication and all as spcified and directed.
32Supply and Install , testing and commissioning the Onload change over switch front handle type of capacity 315 Amp 4pole 415 volts with sheet steel enclosure of made by 3.2mm thick CRCA sheet outdoot type along with pedestal to grout in PCC 1:3:6 type C2 of any thickness foundation and Indication lamps of R, Y, B for three phase supply indication and all as spcified and directed.
33Supply and Install , testing and commissioning the Onload change over switch front handle type of capacity 200/250 Amp 4pole 415 volts with sheet steel enclosure of made by 3.2mm thick CRCA sheet outdoot type along with pedestal to grout in PCC 1:3:6 type C2 of any thickness foundation and Indication lamps of R, Y, B for three phase supply indication and all as spcified and directed.
34Supply, in renewal of fabricating and testing of factory made/fabricated cubical type bypass panel double door outdoor type with degree of protection IP-65 conforming to IS-2147, suitable for 200KVA capacity DG Set, fabricated using 14 Gauge CRCA sheet, powder coated comprising of suitable rated aluminium bus bar to interconnect the Change over No-01 to No-02 ,Onload Change over switch of capacity 315/320Amp 4pole 415 volts -02 No, R ,Y, B LED Indicating lamps provn of connecting incoming and outgoing cables with preper cable glands of adequate size and the angle iron frame of suitable size to mount the panel at height of 45cm from ground level with PCC platform casted in PCC1:3:6 type C-1 (20mm aggregate) of adequate thickness all as specified and directed.
35Supply, in renewal of fabricating and testing of factory made/fabricated cubical type bypass panel outdoor type with degree of protection IP-65 conforming to IS-2147, suitable for 400 KVA capacity DG Set, fabricated using 14 Gauge CRCA sheet, powder coated comprising of suitable rated aluminium bus bar to interconnect the Change over No-01 to No-02 ,Onload Change over switch of capacity 630Amp 4pole 415 volts -02 No R ,Y, B LED Indicating lamps provn of connecting incoming and outgoing cables with cable glands of adequate size and the angle iron frame of suitable size to mount the panel at height of 45cm from ground level with PCC platform casted in 1:3:6 type C1 (20mm aggregate) of adequate thickness all as specified and directed.
36Supply, connecting and testing for MCCB in existing DG set panel of capacity 3 pole 63 -100 Amps with thermal magnetic release breaking capacity 16 KA, Ics=100% Icu , suitable for 415 volts, 50 Hz, with extended terminals type, inter locked to prevent opening when the Switch is in ON position, connecting and testing complete including removal of existing unserviceable complete all as specified and as directed.
37Supply, connecting and testing for MCCB in existing DG set panel of capacity 3 pole 125 Amps with thermal magnetic release breaking capacity 16 KA, Ics=100% Icu , suitable for 415 volts, 50 Hz, with extended terminals type, inter locked to prevent opening when the Switch is in ON position, connecting and testing complete including removal of existing unserviceable complete all as specified and as directed.
38Supply, connecting and testing for MCCB in existing DG set panel of capacity 3 pole 160 Amps with thermal magnetic release breaking capacity 36 KA, Ics=100% Icu , suitable for 415 volts, 50 Hz, with extended terminals type, inter locked to prevent opening when the Switch is in ON position, connecting and testing complete including removal of existing unserviceable complete all as specified and as directed.
39Supply, connecting and testing for MCCB in existing DG set panel of capacity 3 pole 200 Amps with thermal magnetic release breaking capacity 36 KA, Ics=100% Icu , suitable for 415 volts, 50 Hz, with extended terminals type, inter locked to prevent opening when the Switch is in ON position, connecting and testing complete including removal of existing unserviceable complete all as specified and as directed.
40Supply, connecting and testing for MCCB in existing DG set panel of capacity 3 pole 250 Amps with thermal magnetic release breaking capacity 36 KA, Ics=100% Icu , suitable for 415 volts, 50 Hz, with extended terminals type, inter locked to prevent opening when the Switch is in ON position, connecting and testing complete including removal of existing unserviceable complete all as specified and as directed.
41Supply, connecting and testing for MCCB in existing DG set panel of capacity 3 pole 400 Amps with thermal magnetic release breaking capacity 36 KA, Ics=100% Icu , suitable for 415 volts, 50 Hz, with extended terminals type, inter locked to prevent opening when the Switch is in ON position, connecting and testing complete including removal of existing unserviceable complete all as specified and as directed.
42Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc.
43Material and Labour for pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width in type C1 (1:3:6) (20mm graged stone aggregate )and setting in mortar (1:6) including demolition of old PCC Block complete all as specified and as directed
44Demolition and Reuse demolished pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width in type C1 (1:3:6) (20mm graged stone aggregate ) and setting in mortar (1:6) Block work built in cement mortar 1:6 Complete all as specified and directed Note:- ServiceablePCC Block obatined from demolition of PCC Block work shall be re-used after cleaning etc complete all as specified and directed by Engr-in-Charge.
45Material and Labour brickwork with sub class 'B' bricks , straight or curved on plan exc 6m mean raidus built in cement mortar 1:6 including demolition of old brick work complete all as specified and directed
46Demolition and Reuse demolished brick work built in cement mortar 1:6 Complete all as specified and directed Note:- Serviceable bricks obatined from demolition of brick work shall be re-used after cleaning etc complete all as specified and directed by Engr-in-Charge.
47Material and Labour for walling of random rubble, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar 1:6 Including demolition of Old Stone masonary all as specified and directed.
48Demolition and Reuse demolished stone work built in cement mortar 1:6 Complete all as specified and directed Note:- Serviceable stone masonary obatined from demolition of Stone mansonary shall be re-used after cleaning etc complete all as specified and directed by Engr-in-Charge.
49Material and Labour for raised pointing to random or polygonal rubble masonry uncoursed or brought upto course in CM (1:4) complete all as specified and directed.
50Material and Labour for rendering 15 mm thick in CM 1:4 on fair faces of brick/concrete surfaces with two coats i.e (10 mm thick backing coat and 5mm thick finishing coat) , finished even and smooth complete all as specified and directed. (Note:- Item rate shall be include any height of Bldgs for scafolding as all arrangement.)
51M & L for rendering 10 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth complete all as specified. (Note:- Item rate shall be include any height of Bldgs for scafolding as all arrangement.)
52Material and labour for preparation of new plastered surfaces of walls and appplying applying two coats of oil bound distemper over over 1mm thick wall care putty on plastered surfaces complete all as specified and directed.
53Material and Labour for preparation of new or previously untreated plastered surfaces of walls/Ceiling and applying two coats of acrylic antifungal paint exterior grade paint on one coat of primer complete all as specified and as directed.
54Material and Labour for preparation of new or previously untreated plastered surfaces of walls/Ceiling and applying two coats of acrylic antifungal paint exterior grade paint CAMOUFLAGE PATTERN on one coat of primer complete all as specified and as directed.
55Supply and Fix in repair of fiber glass reinforced plastic cover Slabs 1200x600x30mm made from a compostie material of polyester resign and glass fibers with load carrying capacity of 2.5Tonnes. Cover slab shall be embossed MES on upper side Complete all as specified and dicted by Engr-in-chsrge . Make :- Bharat FRP Pune /Nexgen
56Supply and Fix in repair of fiber glass reinforced plastic cover Slabs 600x600x30mm made from a compostie material of polyester resign and glass fibers with load carrying capacity of 2.5Tonnes. Cover slab shall be embossed MES on upper side Complete all as specified and dicted by Engr-in-chsrge . Make :- Bharat FRP Pune /Nexgen
57Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specifedand directed
58Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
59Material and labour for cement concrete type D-2 1:4:8 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete etc as specified and directed.
60Material and Labour for chequered cement concrete tile 30cmX30cmX 20 to 25mm thick set jointed and pointed in neat cement siurry in floor with grey cement and pig ments over 20mm thick screed bed or bedding layer of CM (1:4) including dismentling of old tiles complete all as specified and as directed.
61Material and Labour for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade including dismentling of old tiles complete all as specified & directed .
62Material and Labour for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade including dismentling of old tiles complete all as specified & directed .
63Taking down old paver blocks any shape, size and thickness from the existing surface and refixing at the same place after levelling the ground by using sand caushion for maintaing camber and slope all as per directed by Engr-In Charge Note:- Sand Cushion will be paid under Item No 23
64Material and labour for sand cushioning for laying interlocking paver block complete all as specified and directed.
65Material and labour for 75 mm thick cement concrete type C-1 1:3:6 using 20mm graded crushed stone aggregate as in plinth protection finished fair even laid in bays n.exc 2m in length and joints filled with bitumen mastic 1:3 complete all as specified and directed
66Material and labour for 100mm thick cement concrete type B-2 1:2:4 using 20mm graded crushed stone aggregate as in path/floor finished fair even and smooth without using extra cement, laid in alternate panels of size not exc 4 sqm each including bitumen filling in joints complete all as specified and as directed by Engr-in-Charge.
67S & F steel work as in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS 1161 1979 grade St 240 complete all specified and directed.
68Supply and Fix for rolled sections of FE 410W (Gde-E-250)as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats , Steel Door frame and shutter or other connecting plates complete all specified and directed.
69Supply & fixing of framed work such as grills, gratings, cooler stands etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E-165 incl necessary fixing to walls as directed.
70Supply and Fix MS plate Fe 410-W (Gde E-250 quality A) (Plane/Chequered) 5 mm and over as open drain covers with 02 Nos of 150mm handle in each plate etc complete all as specified and directed by Engr-in-Charge.
71Supply and Fix Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismanlting of old Sheet as specified etc complete all as specified and directed.
72Supply and Fix Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified etc complete all as specified and directed.
73Material and Labour Preparation of new previously untreated steel and iron surfaces of any description not other wise described over 10 centimetre width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome complete all as specified and as directed.
74Material and Labour for greasing and easing in position of mild steel rolling shutters of area n.exc 10sqm each for full movement and for easy operation for shutters including taking down of old Shutter complete all as secified and as directed.
75Material and Labour for greasing and easing in position of mild steel rolling shutters of area exc 10sqm and n.exc 20sqm each for full movement and for easy operation for shutters including taking down of old Shutter complete all as specified and as directed.
76Material and Labour in repair for Opening of rolling shutter hood cover, greasing to gears, helical spring and guide channels and refixing all accessories back in position of area n.exc 10sqm each complete all as secified and as directed.
77Material and Labour in repair for Opening of rolling shutter hood cover, greasing to gears, helical spring and guide channels and refixing all accessories back in position of area exc 10sqm and n.exc 20sqm each complete all as specified and as directed.
78Supply and Fix rolling shutter without ball bearing, thickness of laths 1.00mm as specified including top cover, anchoring rod, hasp and staple, gear operated type with chain wheel and hand chain and primer erected in position including taking down of old Shutter as directed.
79Supply and Fix Steel rolling shutters, with out ball bearing, thickness of laths 1.00mm as specified including top cover, anchoring rod, hasp and staple and erected in position as indicated,complete: push pull or manual type including taking down of old Shutter complete all as specified and directed by Engr-in-Charge
80Material and Labour for preparing new or previously untreated steel surface of any decription over 10cm in width or girth and applying 2 coats of aluminium paint over one coat of red oxide primer complete all as specified and directed.
81Material and Labour for preparing old painted steel surface of any decription over 10cm in width or girth and applying one coats of aluminium paint complete all as specified and directed
82Material and Labour for PCC (1:2:4) type B0 (using 12.5mm graded aggregate) in coping bed black etc including nessesary form work complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56553895
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 84.64 Lakhs
LAST DATE 15-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Certain Civil Works Of Repair/Maint Nature For Dg Sets Cable Trenches, Duct/Trench Covers, Servicing/Painting To Shutters Etc Including E/M Works Like Repair/Replacement Of Ats, Switchgears, Earthing Canopy Etc At Naval Station Karanja
Basic Detail
Tender No 84575-K/E8
Bidding Type Tender
Location
City Raigad
State Maharashtra
Key Dates
Publish Date 18 Jul 2026
Submission Date 15 Aug 2026
Open Date 18 Aug 2026
Finance
Tender Value 84.64 Lakhs
Tender Fee 1000
EMD 1.52 Lakhs
Exemption Not Available
Document List
f568af27-2d23-412e-9532-48e537b5fb84.html
SOC575.pdf
Tendernotice_1.pdf
tenderpages575.pdf
BOQ_873111.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 25 days
Aug 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 28 days

Tender Documents

Download All (ZIP) ↓
html