Defence Statutory Bodies & Commissions/Committees Closing in 17 days TDR #56553894

Tender For Repair And Maintenance Of Metering Equipments, Changeover Switches, Display Sensors And Other Misc Works At Afs Digaru.

Issued by Statutory Bodies & Commissions/Committees · Kamrup Metro, Assam
Tender Value
Ref. Documents
Estimated cost
Bid Submission
08 Aug 2026
17 days left
EMD
30000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kamrup Metro → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of Metering Equipments, Changeover Switches, Display Sensors And Other Misc Works At Afs Digaru.

BOQ

Name of Work:- REPAIR AND MAINTENANCE OF METERING EQUIPMENTS, CHANGEOVER SWITCHES, DISPLAY SENSORS AND OTHER MISC WORKS AT AFS DIGARU.
Sl. No. Item Description
1Taking down old unservicable rolling shutter motor of input power 1013 watt and rated load of 1000 kg from existing postion,carring out major/minor repair like replacement of u/s bearing, break, cap, limit switch, gear box, driver gear including rewinding of motor and installing testing and commissioning of the same at original position complete all as specified and as directed.Make of motor :- Jielong
2M & L for repairing/servicing of electrically operated shutter operating mechanism at parking/storage areas of TP complex complete for both electrical as well as manual operation of the shutters, by checking/repairing of all the parts/systems, cleaning and tightening of all contacts & electrical connections, oiling/lubrication of the gears, bearing & chains etc, checking and properly tightening of all the hardwares, replacing worn out / rusted nuts/bolts/washers etc with new one, checking and setting the mountings for proper alignment and for smooth/trouble free opening/closing of the shutters, checking insulation value of the motor and testing the system for automatic (electric motor mode) and manual operation for trouble free opening and closing of the shutters complete all as specified and as directed.
3Maintenance of existing APFC panel and cleaning of dust inside the cabinet with blower,cleaning of moving parts/contacts from CT cleaner, tightening of loose parts/electrical wires, cleaning of contactors, relays and capacitors junction points,servicing/oiling to cooling fan,complete testing of APFC relay with necessary setting with CTs/load adjustments to match with APFC load management system complete with replacement of worn out u/s components/burnt wire thimbles/lugs complete tested of cap up to 375 KVAR for following :-
4(i) Rate of minor parts/components for replacement shall be included in the unit rate quoted.
5(ii) APFC Panel should be attended throughly and servicing shall be done to the full satisfaction of the Engr-in-Charge.The payment shall be made after complete testing of the AFPC panel.
6(iii) Replacement of small nuts/screws,burnt copper wires/lugs or thimbles/cleaning materials or CTC shall not be paid separately, the cost of these are deemed to include the schedule item rate.
7(iv) The Following parts should be of the same make and capacity of existing one if which is required to be replaced complete all as specified and directed as supply only :-
8(a) Supply only Controller
9(b) Supply only Capacitor Bank 5 KVAR
10( c) Supply only Capacitor Bank 10 KVAR
11(d) Supply only Capacitor Bank 25 KVAR
12( e) Supply only Capacitor Bank 50 KVAR
13Servicing of ACBs by taking out Air circuit breakers of capacity 1250 to 1600 Amps from LT panels cleaning all parts internally and externally checking of the proper tension of the springs mechanical mechanism, tightening of connection of moving, fixed contact, floating contacts, servicing of motor, and charging system lubricating the operating/spring charging/tripping mechanism, cleaning contacts with fine emery paper and CTC and re-fixing it on its original position and testing including testing of control wiring of the respective ACBs complete all as specified and as directed.Note:- Rate is deemed to include minor items i.e, jelly,grease,s/c copper cable upto 1.5 sqmm,screws & locking system.
14All as per above Sl item No 4.00 above but of capacity 800 amps
15Supply and fix in replacement of 3 phase multifuction digital meter compatible to measure current,voltage,power factor & frequency with 3 lines LCD display in 96 x 96 sqmm flush mounted case,accuracy class 1.0 for panel complete all as specified and directed.(Make: AE/L&T)
16Supply and Fix in Repair to UPS 2KVA ,220 volts input and 24 volt output for VCB incluiding the all connection Complete all as specified and directed.
17Supply and fix in replacement Manual changeover Switch in Sheet Metal Enclosure capacity 100 Amp, 415 volt 4P as per direction of engr- in Charge including all the material for fixing and accessories complete all as specified and as directed.Make- L&T/Havells
18Supply and fix in replacement Manual changeover Switch in Sheet Metal Enclosure capacity 250 Amp, 415 volt 4P as per direction of engr- in Charge including all the material for fixing and accessories complete all as specified and as directed.Make- L&T/Havells
19Supply and fix in replacement waterproof outdoor garage Rolling Door lift Switch Box IP -65 as per direction of engr- in Charge including all the all the material for fixing and accessories complete all as specified and as directed.Make- L&T,Havells
20Supply and fix in replacement waterproof Switched Socket and surface mounting box Capacity- 250V 32 A, 2P + E IP -66 with DIN rail for Rolling Shutter as per direction of engr- in Charge including all the material for fixing and accessories complete all as specified and as directed.Make- L&T/Havells Please Enable Macros to View BoQ information
21Supply and fix in replacement waterproof Switched Socket and surface mounting box Capacity- 250V 32 A, 2P + E IP -66 with DIN rail for Rolling Shutter as per direction of engr- in Charge including all the material for fixing and accessories complete all as specified and as directed.Make- L&T/Havells Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56553894
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 08-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair And Maintenance Of Metering Equipments, Changeover Switches, Display Sensors And Other Misc Works At Afs Digaru.
Basic Detail
Tender No C/8916/E8 of 2026-27
Bidding Type Tender
Location
City Kamrup Metro
State Assam
Key Dates
Publish Date 18 Jul 2026
Submission Date 08 Aug 2026
Open Date 15 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 30000
Exemption Available
Document List
BOQ_873234.xls
f52dc90e-3069-4a72-b5ba-1d1532476d9a.html
PS8916.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Aug 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 24 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_873234.xls

html

f52dc90e-3069-4a72-b5ba-1d1532476d9a.html

pdf

PS8916.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders