Tender for Special Repiar To Security Light Cable And Connected Items At Manjakote Under Age(I) Cif®
BOQ
| Sl. No. | Item Description |
| 1 | Supply & Laying of one number PVC insulated and PVC sheathed / XLPE armoured power cable of 1.1 KV grade of cross sectional area 25 sqmm, 3.5 core size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required, specified and as directed. |
| 2 | Supply & Laying of one number PVC insulated and PVC sheathed / XLPE armoured power cable of 1.1 KV grade of cross sectional area 25 sqmm, 3.5 core size direct in the existing RCC/ HUME/ METAL pipe as required, specified and as directed. |
| 3 | Supply & Laying of one number PVC insulated and PVC sheathed / XLPE armoured power cable of 1.1 KV grade of cross sectional area 25 sqmm, 3.5 core size on wall surface (clamped with 1mm thick saddle) as required, specified and as directed. |
| 4 | Supply & Laying of one number PVC insulated and PVC sheathed / XLPE armoured power cable of 1.1 KV grade of cross sectional area 16 sqmm, 4 core size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required, specified and as directed. |
| 5 | Supply & Laying of one number PVC insulated and PVC sheathed / XLPE armoured power cable of 1.1 KV grade of cross sectional area 16 sqmm, 4 core size direct in the existing RCC/ HUME/ METAL pipe as required, specified and as directed. |
| 6 | Supply & Laying of one number PVC insulated and PVC sheathed / XLPE armoured power cable of 1.1 KV grade of cross sectional area 16 sqmm, 4 core size on wall surface (clamped with 1mm thick saddle) as required, specified and as directed. |
| 7 | Erection of steel tubular strut in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required, specified and directed. |
| 8 | Supply & fixing steel tubular swaged pole 09 m long, type 410 SP-31, weight not less than 154 kgs, pole should be in one piece only and smooth finishing, ISI marked conforming to IS:2713-1980, complete with all accessories, such as cast iron base plate, finial taper plug, bolts, nuts, screws, washers and drilling of holes for continious GI earth wire as specified including applying two coat of aluminium paint after preparation of old painting surface by scrappining including marking of black and yellow strip not less than 30 cm width with sythethic enamelled paint from couping to upto height 1.5 mtr of pole alternative way including necessary `MES & Pole number to be wriiten in the circular yellow batch on the pole including taking down old unserviceable pole complete all as specified and directed.Note:-Excavation and earth work shall be measured and paid separately. |
| 9 | Supply & fixing GI Pipe light grade 32/40 mm dia, ISI marked, of required length for protection of cables complete including necessary MS clamps, nuts, bolts and washers etc complete all as specified and directed. |
| 10 | M&L for replacement of GI bracket for fixing of street light fittings bend to shape, made out of 40/50 mm dia GI pipe medium grade suitable for fixing of Light upto 1.2 mtr long fixed with and including two sets of MS clamp made out of Flat iron of size 50x6 mm, fabricated to shape and fixed with nuts, bolts & washers & two coats of aluminum paint over a coat of red oxide primer complete all as specified and directed by Engr-in-charge. |
| 11 | M&L for replacement of wiring with two nos single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 1.5 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 1.5 sqmm as in continuous earth wire drawn into steel pole for connection to security lights from junction box fitted on pole complete all as specified and as directed by the Engineer in charge. |
| 12 | M&L for replacement of junction box hot press moulded SMC of inside dimension size 333 x 233 x 120 mm with locking arrangements consisting of necessary suitable arrangements for incoming & out going cables with cable glands & having aluminium bus bar 4 strips of 20x3mm for TPN on necessary epoxy base insulator and fixing of 6 Amp MCB SP, including necessary 25x3mm flat iron clamps with nuts, bolts & washers all as specified and directed. Make- Sintex GSJB3020 |
| 13 | M&L for replacement of Integral LED security light luminaire 90W LED 230 volts made of pressure die cast aluminium housing powder coated with high power SMD LED’s lens & toughned glass IP-66, Luminaire efficacy >=125 Lumens per Watt ,Secondary optics for better light distribution, having two nos Potted driver(OEM)(one inbult and one spare potted driver) 4KV internal +10KV SPD, THD<10%, pf>0.95 and taking down old unserviceable light fittings any type/wattage complete all as specified and as directed. Make: HPL cat ref No.HPLLEDSL90CWEGLA or equivalent Philips or wipro Please Enable Macros to View BoQ information |
| 14 | M&L for replacement of Integral LED security light luminaire 90W LED 230 volts made of pressure die cast aluminium housing powder coated with high power SMD LED’s lens & toughned glass IP-66, Luminaire efficacy >=125 Lumens per Watt ,Secondary optics for better light distribution, having two nos Potted driver(OEM)(one inbult and one spare potted driver) 4KV internal +10KV SPD, THD<10%, pf>0.95 and taking down old unserviceable light fittings any type/wattage complete all as specified and as directed. Make: HPL cat ref No.HPLLEDSL90CWEGLA or equivalent Philips or wipro Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysAug 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender