Tender For Repair & Maintenance Of 500 Kld And 300 Kld Stp Plant And Swimming Pool At Afssr And Repair /Maintenance Of 100 Kld Stp At Nts Under Ge (Af) Gurgaon
Tender Value
48 Lakhs
Estimated cost
Bid Submission
08 Aug 2026
16 days left
EMD
96000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gurgaon → Haryana
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair & Maintenance Of 500 Kld And 300 Kld Stp Plant And Swimming Pool At Afssr And Repair /Maintenance Of 100 Kld Stp At Nts Under Ge (Af) Gurgaon
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches in soft/loose soil not exceeding 1.5 m depth and n.exc 1.5 m wide for laying of pipes/cables etc and getting out all as specified and directed by Engineer in Charge. |
| 2 | M & L for Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and directed by Engineer in Charge. |
| 3 | Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed by the Engineer-in-Charge |
| 4 | M & L for sand cushioning with a layer of sand 80 mm thick before laying of cables and 150 mm thick after laying of cables in trenches, or in Existing duct as directed for electric cables for protection incl.consolidation complete all as specified and directed. |
| 5 | M&L for brick protection with sub class B bricks,laid dry flat over electric cables in trenches complete all as specified and directed, |
| 6 | Lifting and taking out the sewage submersible pump set and motor of capacity 10 to 15 HP including column pipe by dismantling nut bolt washers and rubber packing etc including disconnecting of submersible cable complete from the sewage sump /well and lowering back the pump after repairing /removing the sludge from the pump including making electrical connection with the existing panel /starter and connecting the complete the column pipe assembly with nut bolts, washers/ packing to the existing header without any leakage complete all as directed. Note :- Rate are deemed to be inclusive for jointing of Submersible Cable , reconnecting the delivery pipe line of submersible pump sets to water mains , testing for satisfactory running & continuous flow of water complete. |
| 7 | All as per item No. 6 desribed here in before but of capacity 2 HP to 7.5 HP complete all as specified and as directed . |
| 8 | M&L for electric arc welding at places like flanges/pipe line, joints , strip of clarifier tank, approach ladder to aeration tank etc all as specified and directed by Engineer-in-Charge. |
| 9 | M&L for rewinding of Submersible motor by taking out burnt copper winding, cleaning the casing & slots with wire brush & washing with pressure water & shall be dried , rewinding the motor using required gauge of super enameled copper winding wire, varnishing and stamping and overhauling etc. Making the winding leak proof & taking out the electric connection with suitable size of submersible cable up to 03 Meter, Capacity of motor 10 HP to 15 HP complete all as specified and as directed . |
| 10 | All as per Item No 9 but 2 HP to 7.5 HP Capacity |
| 11 | M&L for repairing and testing of pump centrifugal/mono block/non clogging upto 5 to 12.5 HP of any make and type including welding work, rotor turning and balancing, re-metaling of shaft bush bearing, keys, mechanincal seal, SS shaft impeller and other such accessories etc required to make pump functional and testing on load complete all as specified and as directed . |
| 12 | M&L for repairing of electric motor upto 5 HP 50 Hz 400/415 volts of mono block/centrifugal pump of any make and type with super enameled copper winding wire including bearing bushes and other accessories etc required to make motor functional and testing on load complete all as specified and as directed |
| 13 | M&L for repairing of electric motor 15 to 20 HP 50 Hz 400/415 volts of mono block/centrifugal pump of any make and type with super enameled copper winding wire including bearing bushes, varnishing and stamping and overhauling. making the winding leak proof etc. and other accessories etc required to make motor functional and testing on load complete all as specified and as directed . |
| 14 | Disconnecting and taking down treated sewage transfer pump set up to 15 HP horizintal type and replacement of burnt copper winding, cleaning the casing & slots with wire brush & washing with pressure water & shall be dried , rewinding the motor using required gauge of super enameled copper winding wire including bearing bushes, mechanical seal rotor tunring & balancing, shaft SS impeller varnishing and stamping and overhauling etc. Making the winding leak proof & taking out the electric connection with suitable size of submersible cable up to 03 Meter and re-assembling and fixing the pump set complete in the same location and testing all as specified and as directed . |
| 15 | M & L for servicing of air blower with positive displacement type twin lube root blower with Motor of 12.5 HP to 15 HP capacities, including Opening the blower motor blower shaft, shaft Key ways, shaft holes etc and M & L for replacing the gland packing, gland nuts, coupling, replacement of oil seal including oil and rewinding of blower motor with super enameled copper winding wire as per existing size including re-fixing the same to the original position and commissioning testing complete all as specified and as directed . |
| 16 | S & F Fan belt B-45 suitable for Air blower including taking down complete all as specified and directed. |
| 17 | M & L for Periodical Cleaning of equalizing tank /grit chamber/ oil grease chamber/stilling chamber of Sewage Water in the tank and Removing of settle down Sewage sludge cum mud/De-Silting etc and making good the patches on walls internally or externally in cement mortor 1:3 where required all as required at site and directed by the Engineer-in-Charge at AF Stn Gurgaon for Sewage tank of STP 500 KLD of under mentioned sizes complete all as specified and directed :- (a) Collection tank dia 6m and depth 9m x 4m - (Sump Well/ Equalization tank). (b) Screen/ grid Chamber. (c) Aeration tank - dia-9m and depth 5m. (d) Clarifier - dia 7.4 mtrs and depth 4.5 mtrs. (e) Sludge drying bed of size 10 m x 4.5 m x1.5m. Note: The rate quoated by the tenderer is deemed to be included in the unit rate of the following :- (a) Diesel Driven Pump Set of appropriate capacity with operators including necessary POL required at site for De- Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes. (b) Lorry/Tractor mounted septic storage tank of appropriate capacity not less than 3 KL should be used for disposing off the same to the location where approved by the Delhi Canttonment Board/MCD. (c ) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects to be observed including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed by the Engineer-in- Charge. |
| 18 | M & L for Cleaning of filter medial tank (ACF & DMF) , pumping out all sludge and foreign material including washing the entire tank and scraping the walls with wire brushes and making good the patches on walls internally or externally where required all as specified and directed by Engr-in-Charge.(Make: MM Aqua/Venayaka Engineers/ Ion Exchange) |
| 19 | M&L for replacing the unserviceable MBBR media with new FAB/MBBR media (Make: MM Aqua/Venayaka Engineers/Bharat Industries |
| 20 | Supply and pouring only DWPE chemical for sewage treatment plant. |
| 21 | Material and labour for replacement of quartz silica sand 32-64 grade complete all as specified and directed by Engr-in-charge. |
| 22 | Material and labour for replacement of quartz silica sand 16-32 grade complete all as specified and directed by Engr-in-charge |
| 23 | Material and labour for replacement of quartz silica sand 8-16 grade complete all as specified and directed by Engr-in-charge. |
| 24 | Material and labour for replacement of quartz silica sand 4-8 grade complete all as specified and directed by Engr-in-charge. |
| 25 | Material and labour for replacement of activated carbon IV 1000 complete all as specified and directed by Engr-in-charge. |
| 26 | Taking out complete pebbles from the filter and and refilling the same pebbles after washing /cleaning thoroughly complete all as specified and directed by Engr-in-charge. |
| 27 | M & L for Periodical Cleaning of equalizing tank /grit chamber/ oil grease chamber/stilling chamber of sewage Water in the tank and Removing of settle down Sewage sludge cum mud/De-Silting etc and making good the patches on walls internally or externally in cement mortor 1:3 where required all as required at site and directed by the Engineer-in-Charge at AF Stn Gurgaon for Sewage tank of STP 300 KLD of under mentioned sizes etc complete all as specified and directed :- (a) Equilizer tank/ /grit chamber/ oil grease chamber/stilling chamber of Sewage Water of size - 6.30m x 4.70m x 6m - 01 No. (b) Sludge holding tank of size - 2.6mx2.6mx3m-01 No. (c ) Fab-1 & Fab-2 of size - 2.1m x 2.1m x 5.80m - 02 Nos. (d) Tube Settler Tank - 4.1m x 2.5m x 3.8m - 01 No. (e) Treated water Tank 9.3 m x 3.4 m x 4.1m-01 No. Note: The rate quoated by the tenderer is deemed to be included in the unit rate of the following :- (a) Diesel Driven Pump Set of appropriate capacity with operators including necessary POL required at site for De- Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes. (b) Lorry/Tractor mounted septic storage tank of appropriate capacity not less than 3 KL should be used for disposing off the same to the location where approved by the Delhi Canttonment Board/MCD. (c ) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects to be observed including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed by the Engineerin-Charge. |
| 28 | Supply and mixing of Sodium hypochloride having 10% chlorine content etc required at site and all as directed by the Engineerin-Charge. |
| 29 | Supply and mixing of Poly aluminium chloride 100% purity etc required at site and all as directed by the Engineerin-Charge. |
| 30 | M&L for repair,servicing,fixing, testing and commissioning of existing 0-6 LPH electrically operated, metered, adjustable dosing pump with accssories including lead tubing , connecting nuts injection check valve with 60 ltr PE/ FRP tank fitted with agiatator all as directed by engineer -in - charge E tank with PE/FRP/HDPE lid and level gauges, mounted on tank all as specified and directed by Engineer -in-charge . Please Enable Macros to View BoQ information |
| 31 | M&L for repair,servicing,fixing, testing and commissioning of existing 0-6 LPH electrically operated, metered, adjustable dosing pump with accssories including lead tubing , connecting nuts injection check valve with 60 ltr PE/ FRP tank fitted with agiatator all as directed by engineer -in - charge E tank with PE/FRP/HDPE lid and level gauges, mounted on tank all as specified and directed by Engineer -in-charge . Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysAug 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer