Tender For Repair, Maint/Rewiring And Replacement Of Internal Light Fitting, Db Boxes, Submain Wiring Of Zone A At Hisar Mil Stn Under Ge (W) Hisar
Tender Value
45 Lakhs
Estimated cost
Bid Submission
08 Aug 2026
7 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hisar → Haryana
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair, Maint/Rewiring And Replacement Of Internal Light Fitting, Db Boxes, Submain Wiring Of Zone A At Hisar Mil Stn Under Ge (W) Hisar
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully copper/ Aluminium point wiring (light, fans, socket, power socket) complete including taking out existing unserviceable terminal boxes and conduit with switches/sockets/fan regulators and fittings such as ceiling roses, pendants, tube lights fittings lamp holders, brackets light fittings, rectangular blocks DB MCCB etc and making good disturbed surface of wall/ floor etc to match with the existing the surface etc complete all as specified and directed. |
| 2 | Taking down carefully copper/ Aluminium point wiring ( light, fans, socket, power socket) complete including taking out existing unserviceable terminal boxes with switches/sockets/fan regulators and fittings such as ceiling roses, pendants, tube lights fittings lamp holders, brackets light fittings, rectangular blocks DB MCCB EXCLUDING CONDUIT and making good disturbed surface of wall/ floor etc to match with the existing the surface etc complete all as specified and directed. |
| 3 | Taking down carefully copper/aluminium Submain wiring from batten /conduit from DBs,MCBs, etc) and making good to disturbed surfaces of walls, floor etc complete all as specified and directed. |
| 4 | Material and labour for point wiring with 1.5 sqmm (22/.3mm) PVC insulated and unsheathed FRLS single core multistranded copper conductor for one light/fan/ bell point in existing PVC rigid non metallic concealed conduit 19/20 mm dia medium duty, ISI marked to be terminated & including pressed modular steel boxes & cover plate of module as required on site.including 1.5 sqmm (22/.3mm) PVC insulated and unsheathed FRLS single core multistranded copper earth continuity conductor controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment complete all as specified and directed. |
| 5 | Description all as per item No 4.00 (here-in-before) but One three pin 5 Amp socket outlet point on independent board controlled by one nos, one way switch on independent board complete all as specified and directed. |
| 6 | Description all as per item No 4.00 (here-in-before) but One three pin 5 Amp socket outlet point on same board controlled by one nos, one way switch on same board complete all as specified and directed. |
| 7 | Description all as per item No 4.00 above but point wiring with 2.5 sq mm single core FRLS cables and earth continuity wire with 2.5 Sq mm single core cable for one 3 pin 15 Amps socket out let point controlled by one nos, one way switch on independent board complete all as specified and directed. |
| 8 | Description all as per item No 4.00 above One light point controlled by two 2- way switches, with cables 1.5 sq. mm size complete all as specified and directed. |
| 9 | Description all as per item No 4.00 above but point wiring with 4 sq mm single core FRLS cables and earth continuity wire with 4 Sq mm single core cable for one 3 pin 15 Amps socket FOR AC complete all as specified and directed. |
| 10 | Material and labour for point wiring with 1.5 sqmm (22/.3mm) PVC insulated and unsheathed FRLS single core multistranded copper conductor for one light/fan/bell point in and including PVC rigid non metallic new concealed conduit 19/20 mm dia medium duty, ISI marked to be terminated & including pressed modular steel boxes & cover plate of module as required on site including 1.5 sqmm (22/.3mm) PVC insulated and unsheathed FRLS single core multistranded copper earth continuity conductor controlled by one switch and/or one regulator complete including repairing the surfaces in Cm 1:3 and finishing the surface as per existing treatment complete all as specified and directed. |
| 11 | Description all as per item No 10.00 (here-in-before) but One three pin 5 Amp socket outlet point on independent board controlled by one nos, one way switch on independent board complete all as specified and directed. |
| 12 | Description all as per item No 10.00 (here-in-before) but One three pin 5 Amp socket outlet point on same board controlled by one nos, one way switch on same board complete all as specified and directed. |
| 13 | Description all as per item No 10.00 above but point wiring with 2.5 sq mm single core FRLS cables and earth continuity wire with 2.5 Sq mm single core cable for one 3 pin 15 Amps socket out let point controlled by one nos, one way switch on independent board complete all as specified and directed. |
| 14 | Description all as per item No 10.00 above but point wiring with 4 sq mm single core FRLS cables and earth continuity wire with 4 Sq mm single core cable for one 3 pin 15 Amps socket FOR AC complete all as specified and directed. |
| 15 | S&F in repairs in repairs Modular switch 1 way 6A 1 module Single pole, one way, 230 volts complete all as specified and directed. |
| 16 | S&F in repairs Modular switch 1 way 16A 1 module complete all as specified and directed. |
| 17 | S&F in repairs Modular switch 2 way 6A 1 module Single pole, one way, 230 volts complete all as specified and directed. |
| 18 | S&F in repairs Modular socket 6A -2/3 pin combined 2 module type 230 volts AC complete all as specified and directed. |
| 19 | S&F in repairs Modular socket 6A/16A -2/3 pin combined 2 module type 230 Volts, AC complete all as specified and directed. |
| 20 | S&F in repairs Modular lamp holder, insulated body with back plate including LED Bulb of 9 watt suitable for batten fittings complete all as specified and directed. |
| 21 | S&F in repairs in repairs LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 22 | M&L Buzzer, Ding Dong AC 230 volts, single pole ISI Marked complete all as specified and directed. |
| 23 | S&F in repairs modular bell push 6A 1 module complete all as specified and directed. |
| 24 | S&F in repairs Modular ceiling rose surface bakelite 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed. |
| 25 | S&F Modular type (1/2 module as per site requirement) ceiling fan regulator electronic step type suitable for 1200mm/1400mm sweep fan complete all as specified and directed. |
| 26 | S&F in repairs LED light fitting 1x20watt 4 feet long including LED tube(PC Housing) with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any crack. The fitting should have following technical specification complete all as specified and directed :- (i) surge protection of minimum 2 KV (ii) power factor should be more than 0.90 (iii) cool white colour, (iv) total hormonic distortion (THD) should not be more than 15% (v) lumen output should not be less than 1700 lumens, (vi) can withstand with input voltage range 140-280V AC, (vii) colour rendering index should not be less than 80, (viii) Corelated colour should be minimum 6000 degree Kelvin (ix) Minimum warranty period of 2 Years. |
| 27 | S&F in repairs LED light fitting 1x40watt 4 feet long including LED tube with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any crack. The fitting should have following technical specification complete all as specified and directed :- (i) surge protection of minimum 2 KV (ii) power factor should be more than 0.90 (iii) cool white colour, (iv) total hormonic distortion (THD) should not be more than 15% (v) lumen output should not be less than 1700 lumens, (vi) can withstand with input voltage range 140-280V AC, (vii) colour rendering index should not be less than 80, (viii) Corelated colour should be minimum 6000 degree Kelvin (ix) Minimum warranty period of 2 Years. |
| 28 | S&F in repairs Inverter type Rechargeable LED Batten light fitting 20watt 4 feet long includes LED tube complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks. Led Batten fitting should be of Elegant design offers high Brightness, Energy Saving, and Upto 4 hrs Back up( when Mains supply is off but switch is on condition), having Powerful lithium battery-2600 mah, battery life -500+ Recharge Cycle, Charging Time-8 hrs to 10 hrs with lumen output should not be less than 100 lumens/Watt ,Corelated colour should be minimum 6000 degree Kelvin, sleek and modern design, emergency light is suitable for use in a variety of indoor, and automatically charges when switch is ON complete all as specified and directed. |
| 29 | S&F in repairs Modular switch 1 way 6A 1 module Single pole, one way, 230 volts as per existing model at site complete all as specified and directed. |
| 30 | S&F in repairs Modular switch 1 way 16A 1 module as per existing model at site complete all as specified and directed. |
| 31 | S&F in repairs Modular switch 2 way 6A 1 module Single pole, one way, 230 volts as per existing model at site complete all as specified and directed. |
| 32 | S&F in repairs Modular socket 6A -2/3 pin combined 2 module type 230 volts AC as per existing model at site complete all as specified and directed. |
| 33 | S&F in repairs Modular socket 6A/16A -2/3 pin combined 2 module type 230 Volts, AC as per existing model at site complete all as specified and directed. |
| 34 | S&F in repairs Buzzer, Ding Dong AC 230 volts, single pole ISI Marked, complete all as specified and directed. |
| 35 | S&F in repairs modular bell push 6A 1 module. as per existing model at site complete all as specified and directed. |
| 36 | S&F Modular type (1/2 module as per site requirement) ceiling fan regulator electronic step type suitable for 1200mm/1400mm sweep as per existing model at site complete all as specified and directed. |
| 37 | S&F in repairs white cover plate for 1 module as per existing model at site complete all as specified and directed. |
| 38 | S&F in repairs white cover plate for 2 module as per existing model at site complete all as specified and directed. |
| 39 | S&F in repairs white cover plate for 3 module as per existing model at site complete all as specified and directed. |
| 40 | S&F in repairs white cover plate for 4 module as per existing model at site complete all as specified and directed. |
| 41 | S&F in repairs white cover plate for 6 module as per existing model at site complete all as specified and directed. |
| 42 | S&F in repairs white cover plate for 8 module as per existing model at site complete all as specified and directed. |
| 43 | S&F HYLEM sheet laminated 3 mm thick including cutting required size drilling holes for incorporating switch, socket, regulators etc. complete all as specified and directed :- |
| 44 | of size 10x6 inch |
| 45 | of size 7x5 inch |
| 46 | of size 4x4 inch |
| 47 | S&F in repairs 5 Amps switch piano type complete all as specified and directed. |
| 48 | S&F in repairs 15 Amps switch piano type complete all as specified and directed. |
| 49 | S&F in repairs 5 Amps socket piano type complete all as specified and directed. |
| 50 | S&F in repairs 15 Amps socket piano type complete all as specified and directed. |
| 51 | S&F in repairs piano type fan regulator (switch/socket type) complete all as specified and directed. |
| 52 | S&F in repairs piano type bell push complete all as specified and directed.NOTE : For item No 29.00 to 49.001. ITEM NO. 29 TO 49 ARE CATERED FOR THE COMPLAINT BASIS,THE CONTRACTOR HAVE TO ATTEND THE COMPLAINT WITH IN 08 HRS .IF THE CONTRACTOR FAILS TO ATTEND THE COMPLAINT WITHIN GIVEN TIME FRAME RECOVERY @ RS 50/COMPLAINT WILL BE IMPOSED AND DEDUCTED FROM WORKDONE AMOUNT. |
| 53 | S&F in repairs metal flush box 1/2 module complete all as specified and directed. |
| 54 | S&F in repairs metal flush box 3 module complete all as specified and directed. |
| 55 | S&F in repairs metal flush box 4 module complete all as specified and directed. |
| 56 | S&F in repairs metal flush box 6/8 module complete all as specified and directed. |
| 57 | S&F in repairs of modular type Gang box for 2 module complete all as specified and directed. |
| 58 | S&F in repairs of modular type Gang box for 3 module complete all as specified and directed. |
| 59 | S&F in repairs of modular type Gang box for 4 module complete all as specified and directed. |
| 60 | S&F in repairs of modular type Gang box for 6 module complete all as specified and directed. |
| 61 | S&F in repairs of modular type Gang box for 8 module complete all as specified and directed. |
| 62 | S&F in repairs PVC 25mm casing and caping, ISI marked complete all as specified and directed. |
| 63 | Refixing of existing or new ceiling fan of any sweep including dismantling from existing position, checking of connections, reconnection of wiring, providing proper insulation, tightening of nut and bolts, levelling/alignment and refix the fan at location complete all as specified and directed. |
| 64 | Refixing of existing geyser after repair of any capacity including dismantling from existing position, checking of connections, reconnection of wiring, providing proper insulation, tightening of nut and bolts, levelling/alignment, necessary plumbing works and refix the geyser at location complete all as specified and directed. |
| 65 | S&F in repairs in replacement LED light fitting Surface/Roof mounting Round type complete 1x12 W , (Dimension(mm) for round light : Ø180x40) polycarbonate batten including LED Tube, suitable for Dot auditorium complete all as specified and directed. |
| 66 | S&F in repairs in replacement LED light fitting Surface/Roof mounting square type complete 1x12 W ,(Dimension(ft) for square light : 1x1) polycarbonate batten including LED Tube, complete all as specified and directed. |
| 67 | S&F in repairs in replacement LED light fitting Surface/Roof mounting square type complete 18 Watt /20 Watt/22 Watt ,(Dimension(ft) for Square light : 1x1,Dimension(mm) for round light : dia 200/220 ) polycarbonate batten including LED Tube, complete all as specified and directed. |
| 68 | S&F in repairs in replacement Cool White LED light fittings 36 watt diffuser type Recess Mounting type with mounting arrangement (Recess suitable for, 2x2 Grid, Hanging) CCT 6500K, powder coated CRCA sheet steel with high quality LGP and PMMA diffuser. Separate HPF driver suitable for Armstrong and grid ceilling LED 240 volt along with fixing arrangements complete all as specified and directed. |
| 69 | S&F in repairs in replacement Cool White LED light fittings 36 watt diffuser type Surface Mounting type with mounting arrangement (Surface suitable for, 2x2 Grid, Hanging) CCT 6500K, powder coated CRCA sheet steel with high quality LGP and PMMA diffuser. Separate HPF driver suitable for Armstrong and grid ceilling LED 240 volt along with fixing arrangements complete all as specified and directed. |
| 70 | S&F in repairs in replacement Warm White LED light fittings 36 watt diffuser type Recess Mounting type with mounting arrangement (Recess suitable for, 2x2 Grid, Hanging) CCT 6500K, powder coated CRCA sheet steel with high quality LGP and PMMA diffuser. Separate HPF driver suitable for Armstrong and grid ceilling LED 240 volt along with fixing arrangements complete all as specified and directed. |
| 71 | S&F in repairs in replacement Warm White LED light fittings 36 watt diffuser type Surface Mounting type with mounting arrangement (Surface suitable for, 2x2 Grid, Hanging) CCT 6500K, powder coated CRCA sheet steel with high quality LGP and PMMA diffuser. Separate HPF driver suitable for Armstrong and grid ceilling LED 240 volt along with fixing arrangements complete all as specified and directed. |
| 72 | S&F in repairs in replacement LED light fittings 36 watt designer sky panel diffuser type Recess Mounting type with mounting arrangement (Recess suitable for, 2x2 Grid, Hanging) CCT 6500K, powder coated CRCA sheet steel with high quality LGP and PMMA diffuser. Separate HPF driver suitable for Armstrong and grid ceilling LED 240 volt along with fixing arrangements complete all as specified and directed. |
| 73 | M&L for Galaxy LED suspended type decorative LED low bay luminaire white colour of capacity 24 Watt suitable for suspending on office table complete all as specified and directed. |
| 74 | S&F in repairs decorative wall light ss housing fixture white glass diffuser B22 Holder suitable for 9 watt LED bulb complete all as specified and directed. |
| 75 | S&F in repairs Sheet metal enclosure distribution board SP&N,2 way, Single door powder coated, protection class IP-42 suitable for mounting MCB DBs confirming to IS-13032, IS-8632,BS5484 complete all as specified and directed. |
| 76 | S&F in repairs Sheet metal enclosure distribution board SP&N,4 way, Single door powder coated, protection class IP-42 suitable for mounting MCB DBs confirming to IS-13032, IS-8632,BS5484 complete all as specified and directed. |
| 77 | S&F in repairs Sheet metal enclosure distribution board SP&N,8 way, double door powder coated, protection class IP-42 suitable for mounting MCB DBs confirming to IS-13032, IS-8632,BS5484 with min 200 Amp rating copper bus bar complete all as specified and directed. |
| 78 | S&F in repairs Sheet metal enclosure distribution board SP&N,12 way, double door powder coated, protection class IP-42 suitable for mounting MCB DBs confirming to IS-13032, IS-8632,BS5484 with min 200 Amp rating copper bus bar complete all as specified and directed. |
| 79 | S&F in repairs MCBs SP 6 to 32Amps, 240 volts, 10 KA rupturing capacity, IS-8828 marked, of the under mentioned type and rating and fixing in DBs (DBs Catered separately in this schedule) complete all as specified and directed.Note:- Make of the MCB should be the same as that of DB |
| 80 | S&F in repairs MCBs SPN 32Amps to 63 Amps, 240 volts, 10 KA rupturing capacity, IS-8828 marked, of the under mentioned type and rating and fixing in DBs (DBs Catered separately in this schedule) complete all as specified and directed. Note:- Make of the MCB should be the same as that of DB |
| 81 | S&F in repairs i Sheet metal enclosure distribution board VTPN,6 way, double door powder coated, protection class IP-54, isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCCB as incoming and TPN/MCB's as outgoing in DBs confirming to IS-13032, IS-8632,BS5484 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed. |
| 82 | S&F in repairs i Sheet metal enclosure distribution board VTPN,4 way, double door powder coated, protection class IP-54, isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCCB as incoming and TPN/MCB's as outgoing in DBs confirming to IS-13032, IS-8632,BS5484 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed. |
| 83 | S&F in repairs TPN 63 Amps, 415 volts, 10 KA rupturing capacity, IS-8828 marked, of the under mentioned type and rating and fixing in DBs (DBs Catered separately in this schedule) complete all as specified and directed.Note:- Make of the TPN should be the same as that of DB |
| 84 | S&F in repairs MCCBs FP 63 Amps, 415 volts, 16 KA rupturing capacity, IS-8828 marked, of the under mentioned type and rating and fixing in DBs (DBs Catered separately in this schedule) complete all as specified and directed.Note:- Make of the MCCB should be the same as that of DB |
| 85 | S&F in repairs MCCBs FP 100 Amps, 415 volts, 16 KA rupturing capacity, IS-8828 marked, of the under mentioned type and rating and fixing in DBs (DBs Catered separately in this schedule) complete all as specified and directed.Note:- Make of the MCCB should be the same as that of DB |
| 86 | S&F in repairs MCCBs FP 125 Amps, 415 volts, 16 KA rupturing capacity, IS-8828 marked, of the under mentioned type and rating and fixing in DBs (DBs Catered separately in this schedule) complete all as specified and directed.Note:- Make of the MCCB should be the same as that of DB |
| 87 | S&F in replacement of Bldg security light fitting LED 30/35W, pressure die cast housing epoxy powder coating IP -65, connected with and including 0.5 sqmm flexible copper multistranded conductor cable including security light bracket made to shape out of GI pipe 40 mm bore light grade, 1.5 mtr length and fixed with MS Calmps of size 40x5 mm- 02 nos ,nuts, bolts and washers on wall complete all as specified and directed. |
| 88 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm nominal cross section, 2 Core in service connections complete all as specified and directed. |
| 89 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 16 sq. mm nominal cross section,2 Core in service connections complete all as specified and directed. |
| 90 | M&L for submain wiring alongwith earth wire with the 2x6.0 sq. mm +1x6.0 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed as required complete all as specified and directed.Note: The above mentioned specified runs of single core cables and specified runs of earth continuity conductors and the relevant conduit with accessories shall be measured as one run length. |
| 91 | M&L for submain wiring alongwith earth wire with the 2x10.0 sq. mm +1x10.0 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed as required complete all as specified and directed.Note: The above mentioned specified runs of single core cables and specified runs of earth continuity conductors and the relevant conduit with accessories shall be measured as one run length. |
| 92 | S&F in repairs Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 AMP complete all as specified and directed. |
| 93 | Supply only PVC type self adhesive electric Insulation tape roll (white/black) of length 25 metre and17 mm width with ISI marked complete all as specified and directed. |
| 94 | S&F in repairs of post top lantern of LED 25W with symmetrical light distribution , spun alumnium landscape luminaire with high power LEDs as light source ,ip 65 protection with suitable GI tubing including all accessories complete all as specified and directed. Make- Bajaj CG Syska or equivalent. |
| 95 | Supply only aluminium lugs suitable for cable of size 10 to 16 sqmm complete all as specified and directed. |
| 96 | Supply only aluminium lugs suitable for cable of size 25 sqmm complete all as specified and directed. |
| 97 | S&F in repairs in Replacement of GI Bracket 25 mm light grade dia pipe for Building Light including clamp & nut bolts complete all as specified and directed. |
| 98 | S&F in repair LED driver 25/30 W/36W LED recess/surface light fitting Indoor type suitable for existing light fitting as per sample complete all as specified and directed. |
| 99 | S&F in repair LED SPD 25/30 W/36W LED recess/surface light fitting Indoor type suitable for existing light fitting as per sample complete all as specified and directed. |
| 100 | S&F, in repair PVC air fresh Fan 200/250 mm sweep, 230 volts, fixed on wall with suitable size nut, bolts and washers and connection complete all as specified and directed. Note; Make a hole as per site requirement rate include in this price. |
| 101 | S&F Exhaust Fan steel body with louvers and accessories 230 V 300 MM sweep heavy duty with blades & copper winding with service value all as specified and directed. Note; Make a hole as per site requirement rate include in this price. |
| 102 | M&L for WEE Plus LED bulk head luminaire of capacity 10 Watt an ideal energy efficient solution for upgrading conventional GLS bulkhead luminaires to LED bulk head IP 65 complete all as specified and directed. |
| 103 | S&F in repairs HI Bay light (LENS TYPE) of 80 Watt for ceiling mount suspended or surface type with very high efficiency in PDC housing suitable for the shed/vehicle garage with luminaire efficiency of 120lm/watt with IP-65 protection including connecting 3 core copper wire of size 1.5 sqmm complete all as specified and directed. |
| 104 | M&L for Earthing complete with galvanised mild steel earth electrode plate 600 X 600 X 3.15 mm thick buried directly and vertically in ground connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanised iron 15 mm bore medium grade pipe with all fittings from the earth electrode fixed along pole or wall with and including 25 x 6mm flat iron clamp, bolts, nuts and washers and watering pipe shall be 20 mm bore GI medium grade from top of the earth pit to top of earth plate electrode including all excavation and earth work in any type of soil and removal of soil upto 10 metre, PCC pit with pre-cast RCC cover with handle, charcoal/salt, funnel , CI frame etc complete all as specified and directed.NOTES : (i) The concrete pit shall be made in PCC 1:2:4 type B-O, using 12.00 mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover (ii) Item includes the cost of 7.5 metre GI pipe for protection of earth wire. (iii) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides. |
| 105 | M&L for Earthing complete with copper earth plate of size 60 cm x 60cm x 3.15 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to copper strip of size 20x3mm by means of tinned brass bolt/snuts/washers, protected by 40mm bore GI medium grade pipe from earth plate & upto 3m long pole fixed with 2 clamp made from mild steel flat iron 32x6mm bolts, nuts, washer etc. earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15cm thick all around bottom and top of earth plate 20mm dia GI Medium grade pipe for watering and including funnel, wire mesh, RCC cover & frame PCC 1:3:6 type C1 using 20mm graded stone aggregate as in earthing pit including necessary excavation & earth work all as specified & shown on electrical plate No. 3 of SSR Part-I, (Note: (i) PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysAug 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender