Defence Statutory Bodies & Commissions/Committees Closing in 13 days TDR #56553820

Tender For special Repair To Existing Sewage Line Block No P-36,37,38,39,40,41,42,4344,45,46,47,48,49,55,56,57, 58,59,60,80,85,86,86,88,89,90,91 & 92 Jcos/ Or Md Accn In Tower Colony And special Repair Of Sewage Line, Septic Tank, Drain And Misc Work

Issued by Statutory Bodies & Commissions/Committees · Ajmer, Rajasthan
Tender Value
Ref. Documents
Estimated cost
Bid Submission
06 Aug 2026
13 days left
EMD
96000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ajmer → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repair To Existing Sewage Line Block No P-36,37,38,39,40,41,42,4344,45,46,47,48,49,55,56,57, 58,59,60,80,85,86,86,88,89,90,91 & 92 Jcos/ Or Md Accn In Tower Colony And special Repair Of Sewage Line, Septic Tank, Drain And Misc Work In Mes Colony Under Ge Nasirabad

BOQ

Name of Work:- SPL REPAIR TO EXISTING SEWAGE LINE BLOCK NO P-36,37,38,39,40,41,42,4344,45,46,47,48,49,55,56,57, 58,59,60,80,85,86,86,88,89,90,91 & 92 JCOs/ OR MD ACCN IN TOWER COLONY AND SPL REPAIR OF SEWAGE LINE, SEPTIC TANK, DRAIN AND MISC WORK IN MES COLONY UNDER GE NASIRABAD
Sl. No. Item Description
1Earth work in all kind of soil excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m complete all as specified and directed.
2Removal of excavated material (soil) to a distance not exceeding 250 metre and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
3Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil complete all as specified and directed.
4Demolition and breaking up 150mm dia in bore drain pipes (salt glazed stone ware, AC or Reinforced concrete) set in cement mortar in any description complete all as specified and directed.
5M&L for 150mm dia Sail-glazed stone ware drain pipes drain pipes laid in trenches and jointed complete all as specified and directed.
6M&L Concrete bed to drain pipes including packing under and haunching against the sides of pipe as cradle afterr they are laid and tested in cement concrete 1:3:6 type C-2 (Nominal mix using 20mm graded crushed stone aggregate for 150 mm bore pipes complete all as specified and directed.
7Demolition and breaking up 200 mm dia in bore drain pipes (salt glazed stone ware, AC or Reinforced concrete) set in cement mortar in any description complete all as specified and directed.
8M&L for 200 mm dia Sail-glazed stone ware drain pipes drain pipes laid in trenches and jointed complete all as specified and directed.
9M&L Concrete bed to drain pipes including packing under and haunching against the sides of pipe as cradle after they are laid and tested in cement concrete 1:3:6 type C-2 (Nominal mix using 20mm graded crushed stone aggregate for 200 mm bore pipes complete all as specified and directed.
10M&L for Cement concrete 1:3:6, type C-2 (Nominal mix) using 40 mm graded crushed stone aggregates in foundation filling and mass concrete complete all as specified and directed.
11Demolition of brick work or stone masonary built in cement mortar etc complete all as specified and directed.
12M&L for Brick work with sub class 'B' bricks, old size bricks having crushing strength not less than 75 Kg/Sqcm, straight or curved on plan exceeding 6m mean radius with old size bricks built in cement mortar 1:4 complete all as specified and directed.
13M&L for Random Rubble stone walling uncourses, built in CM (1:6) complete all as specified and directed.
14Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, hammer dressing with maximum depression on face from straight edge held against the dressed surface n. exc 20mm complete all as specified and directed.
15M&L for preparation of new plastered surfaces of Wall and applying three coats of white wash complete all as specified and directed.
16S&F in repair 110mm PVC (SWR) pipes single socketed in any length with rubber joints fixed to wall or laid in floors / trenches with & including existing / new MS stack clamps of FI 50 x 3mm complete all as specified and directed.
17S&F in repair 75mm PVC (SWR) pipes single socketed in any length with rubber joints fixed to wall or laid in floors / trenches with & including existing / new MS stack clamps of FI 50 x 3mm complete all as specified and directed.
18M&L for Plain Cement concrete 1:2:4 Type B0 using 12.5 mm graded crushed stone aggregate in coping, benching and the like including weathering, slightly rounded or chamfered angles as directed including form work and finishing all exposed surfaces complete all as specified and directed.
19M&L PCC (1:2:4) type B 0 using 12.5 mm graded stone aggregate as in drain and surface channel complete all as specified and directed.
20Extra for forming fair finished surfaces of drain or channels, inner girth 30 cms, using extra cement including forms, moulds mitred/ stoppedends etc. complete all as specified and directed.
21M&L for Rendering 15 mm thick on fair faces of brick/stone surfaces in cement mortar (1:4) finished even and fair complete all as specified and directed.
22Dismantling of sand stone slab as in cover slab of any thickness laid, bedded and pointed in any mortar complete all as specified and directed.
23M&L for Precast cement concrete type B-1, 1:1.5:3 (Nominal mix) using 20 mm grade crushed stone aggregate, as in cover slabs (for manhole etc.) casted at site and setting in cement mortar 1:4 complete all as specified and directed.
24M&L for TMT bars (Fe 500), 10 mm dia and over in reinforcement cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
25M&L for TMT bars (Fe 500), 6 to 8 mm dia and over in reinforcement cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
26Cutting into existing manholes for removing existing branch drain, making good to pipe and rendering cutting out branch channel, and making good for any dia bore pipe complete all as specified and directed.
27M&L for Septic tank for 100 users, designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Brickwork in CM(1:3), RCC M-30 Design Mix in Baffle walls and Roof Slab including beams etc with Vent shaft, manhole openings with cover connection etc. complete all as specified and directed and as shown in Drg No. CEBZ/TD/76/2011 Sheet 1/1 & 1/2.
28M&L for Septic tank for 50 users, designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Brickwork in CM(1:3), RCC M-30 Design Mix in Baffle walls and Roof Slab including beams etc with Vent shaft, manhole openings with cover connection etc. complete all as specified and directed and as shown in Drg No. CEBZ/TD/76/2011 Sheet 1/1 & 1/2.
29Soakage walls excavation in any type of soil, foundation in PCC 1:3:6 wells of honey combed and soild in M-25 concrete, including intercepting chamber, screen chamber Brick work in CM, RCC cover slab in M-25/RR masonary/Filling with brick bats, complete of size (3.0 m dia x 3.0M deep) complete all as specified and directed.
30Cleaning of sewage line by roding manhole to manhole, manually, removing sludge/foreign material completly and making smooth flow of sewage water for 150/200mm dia bore pipes complete all as specified and directed. Please Enable Macros to View BoQ information
31Cleaning of sewage line by roding manhole to manhole, manually, removing sludge/foreign material completly and making smooth flow of sewage water for 150/200mm dia bore pipes complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56553820
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 06-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair To Existing Sewage Line Block No P-36,37,38,39,40,41,42,4344,45,46,47,48,49,55,56,57, 58,59,60,80,85,86,86,88,89,90,91 & 92 Jcos/ Or Md Accn In Tower Colony And special Repair Of Sewage Line, Septic Tank, Drain And Misc Work In Mes Colony Under Ge Nasirabad
Basic Detail
Tender No 8721/E8
Bidding Type Tender
Location
City Ajmer
State Rajasthan
Key Dates
Publish Date 18 Jul 2026
Submission Date 06 Aug 2026
Open Date 08 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 96000
Exemption Available
Document List
b0a0fa61-e6e2-4d61-8d63-aa2e2394a72c.html
BOQ_873194.xls
GeneralPages8721.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Aug 08, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

b0a0fa61-e6e2-4d61-8d63-aa2e2394a72c.html

xls

BOQ_873194.xls

pdf

GeneralPages8721.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender