Housing Urban and Rular Development Government Departments Closing in 6 days TDR #56547630

Tender For B.O.Q For Construction Of Brc Govt. Middle School Nadoora Anantnag B.W.O Electric Work

Issued by Government Departments · Anantnag, Jammu and Kashmir
Tender Value
2.87 Lakhs
Estimated cost
Bid Submission
29 Jul 2026
6 days left
EMD
5756
Bank guarantee accepted
Document Fee
300
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Anantnag → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for B.O.Q For Construction Of Brc Govt. Middle School Nadoora Anantnag B.W.O Electric Work

BOQ

Name of Work:- B.O.Q for Construction of BRC Govt. Middle School Nadoora Anantnag B.W.O Electric work
Sl. No. Item Description
1Wiring for lighting points/fan points/exhaust fan points/call bell points with 2x1.5 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit, with 240V 6A modular switch ,modular plate, suitable GI box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable, etc. as required. (Havells/ Polycab/ Apar/ Anchor/ SSK or equivalent make) including the cost of conduit.
2Supply, Installation, Testing and Commissioning of 15W/+ LED recessed/mounted (round or square) Down lighters having aluminum body, minimum 100lm/w, average life 50000 hours, Operating temperature -10°C to +45°C.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India.The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells/ Philips/ Crompton/ Jaguar/Wipro).
3Supply, Installation, Testing and Commissioning of 1200 mm sweep ceiling fan with 3 No. Aluminium blades, reqd. long down rod, 2nos. canopies,safety cable, shackle kit, Power Factor not less than 0.9, 45-54W, Air flow 7200-7500cfm, RPM>340, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, and including iron hook complete job.The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending departm (USHA/Havells/Crompton/Phillips/bajaj) as directed by engineer incharge.
4Supply, Installation, Testing and Comm. Of 200/250mm sweep exhaust fan Shutter type of havell /Bajaj/ Crompton/equivalent make as directed by engineer incharge,Air Flow capacity >850cmph, 35-50Watts,Noise level 44db, 1200 rpm,water resistant, including making of space in wall/ window as per site requirement and necessary connections.The job includes replacement warranty of fixture if damaged/burn out what so ever reason for a period of two years reckoned from the date of sucessful commissioning / handing over of site to the intending department.(To be got approved before installation from EIC)
5Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch connections etc. as required.( Anchor roma plus/Legrand Mylinc /SSK/Schneider Zencelo /Crabtree athena make).
6Supplying and fixing of GI box along with modular base and cover plate for modular sockets, switches in recess etc as required 6 module (200mm x 75mm)
7Supplying and fixing of 5pin 5-10A socket and 5-10A switch on existing modular plate, incl connections etc as required. (Havells/SSK/Anchor/ABB/Schneider)
8Wiring for light/power plug points (15/16A heating points) with 2x4 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit along with 1x4 sq. mm FRLS PVC insulated copper conductor single core cable for earthing, etc. as required including the cost of conduit.(Havells/ Polycab/ Anchor/ SSK or equivalent make)
9Wiring for 5-10A socket out lets for computer with 2X2.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for earthing etc. as required including the cost of conduit.(Havells/ Polycab/ Anchor/ SSK or equivalent make)
10Supplying and fixing of indicators on existing modular plate and switch box , incl. connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or equivalent).
11Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate as required.
12Supply and fixing of 6 way (4+18), Double door surface/ recess mounting, Horizontal type, 240 V, SP&N MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer. (Havells/Legrand/SSK/Schnider/ABB)
13Supply, installation, testing and commissloning of 5-32A single pole rating 240/415V,10 KA \\"C\\" curve MCB of Legrand/ Havells/ L&T/ABB suitable for inductive load in the MCBdistribution board complete with necessary connections.
14Supply, installation, testing and commissioning of 32A DP rating 240/415V,10 KA \\"C\\" curve MCB of Legrand/ Havells/L&T/ABB suitable for inductive load in the MCB distribution board complete with necessary connections.
15Supply, installation, testing and commissioning of 40A DP rating 240/415V,10 KA \\"C\\" curve MCB of Legrand/ Havells/ L&T/ABB suitable for inductive load in the MCB distribution board complete with necessary connections.
16Supply, installation, testing and commissioning of 63A DP rating 240/415V,10 KA \\"C\\" curve MCB of Legrand/ Havells/ L&T/ABB suitable for inductive load in the MCB distribution board complete with necessary connections.
17Main Panel
18Design, Fabrication, Supplying, Installation, Testing and Commissioning of following panel, duly manufactured from CPRI approved manufacturer, made out of 2mm thick M.S. sheet steel , floor/wall mounted, vermin and dust proof, indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears, , Aluminium Bus Bar of various ratings after taking Derating factor into account, and other allied accessories etc. as required. (As per approved design,size may vary as per site requirement)
19Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required.
201. Normal INCOMING:
21a)125A DP MCB 10 KA Havells/Legrand/ Schinider/ABB/L&T sample to be approved before installation..
22b) 4 No. of Aluminium Bus Bar of 300 Amp.
23c)Digital meters and phase indicators -1 set.
243.INVERTER
25a) 32A DP MCB 10KA
26b) 2 No. of Aluminium Bus Bar of 63 Amp.
27c) Digital meter and phase indicators 01 set.
28Wiring for Circuit/Sub mains along with earth wire in FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires in recessed or surface conduiting system, including the cost of conduit. (Havells/ Polycab/ Finolex/ Anchor/KEI/RR or equivalent).
292x10 sq mm +1x6 sq mm Heating submain
302x 6 sq mm + 1x 6 sq mm Inverter Lighting submain
312x 4 sq mm + 1x 4 sq mm Lighting submain
322x 2.5 sq mm + 1x 2.5 sq mm Lighting circuit
33Supply, Installation, Testing and Commissioning of 1400VA-1625VA 12V Power Inverter provided and fitted with 2 No. 12V, 180 Ah, tall tubular battery of Exide/ Microtech/ Luminous make and PVC battery trolley for housing of battery. The job includes terminal connections of batteries, input/output leads of required size and length, carriage and applicable taxes.Sample to be approved by EIC
34Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.Complete Job.
35Providing and laying earth connection from earth electrode with 8 mm dia copper wire in 15 mm dia G.l. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
36Supply, laying, connecting and commissioning of 25 sq mm 2 core XLPE/ PVCInsulated and steel armored 1.1 KV grade Aluminum LT cable for Service line, incl. cost of required al. thimbles duly crimped. (Over head/ under ground). Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56547630
AUTHORITY Government Departments
TENDER VALUE 2.87 Lakhs
LAST DATE 29-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for B.O.Q For Construction Of Brc Govt. Middle School Nadoora Anantnag B.W.O Electric Work
Basic Detail
Tender No NIT No.83//2026-27 Dt/18/07/2026
Bidding Type Tender
Location
City Anantnag
State Jammu and Kashmir
Key Dates
Publish Date 18 Jul 2026
Submission Date 29 Jul 2026
Open Date 30 Jul 2026
Finance
Tender Value 2.87 Lakhs
Tender Fee 300
EMD 5756
Exemption Not Available
Document List
BOQ_1034215.xls
d5f47f43-f209-4830-8d9e-54bf0d3a9a19.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Jul 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1034215.xls

html

d5f47f43-f209-4830-8d9e-54bf0d3a9a19.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders