Bids Are invited for Facility Management Services - Lumpsum Based - Industrial; O M Of Electrical Work, Transformer Oil S Ling And Testing; Consumables To Be Provided By Service Provider (Inclusive In Contract Cost) - Test For Bdv, Moisture, Acidity,
Tender Overview
Project Description
Bids Are invited for Facility Management Services - Lumpsum Based - Industrial; O M Of Electrical Work, Transformer Oil S Ling And Testing; Consumables To Be Provided By Service Provider (Inclusive In Contract Cost) - Test For Bdv, Moisture, Acidity, Sp.Resistance ,Interfacial Tension ,Tan Delta ,Flash Point , Sludge Content, Dissolved Gas Analysis Of Transformer Oil For Power Transformers With 6 Monthly Frequency Including Transportation Charges 8S Les/Visit) As Per Technical Specification , Test For Bdv, Moisture, Acidity, Sp.Resistance ,Interfacial Tension ,Tan Delta, Flash Point , Sludge Content, Dissolved Gas Analysis Of Transformer Oil For Power Transformers With Yearly Frequency Including Transportation Charges 12S Les/Visit)As Per Technical Specification , Test For Bdv, Moisture And Acidity Of Transformer Oil With Frequency Of Yearly For Auxiliary Transformers Including Transportation Charges –(12S Les/Visit)As Per Technical Specification. , Furan Analysis For Transformers Oil With Yearly Frequency Including Transportation Charges(20S Les/Visit) Including Transportation Charges As Per Technical Specification
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Test for BDV, moisture, acidity, Sp.resistance ,Interfacial tension ,tan delta ,flash point , sludge content, dissolved gas analysis of transformer oil for power transformers with 6 monthly frequency including transportation charges 8samples/Visit) as per technical specification | Test for BDV, moisture, acidity, Sp.resistance ,Interfacial tension ,tan delta ,flash point , sludge content, dissolved gas analysis of transformer oil for power transformers with 6 monthly frequency including transportation charges 8samples/Visit) as per technical specification |
| 2 | Test for BDV, moisture, acidity, Sp.resistance ,Interfacial tension ,tan delta, flash point , sludge content, dissolved gas analysis of transformer oil for power transformers with Yearly frequency including transportation charges 12samples/Visit)as per technical specification | Test for BDV, moisture, acidity, Sp.resistance ,Interfacial tension ,tan delta, flash point , sludge content, dissolved gas analysis of transformer oil for power transformers with Yearly frequency including transportation charges 12samples/Visit)as per technical specification |
| 3 | Test For BDV, Moisture and acidity of transformer oil with frequency of yearly for auxiliary transformers including transportation charges –(12samples/Visit)as per technical specification. | Test For BDV, Moisture and acidity of transformer oil with frequency of yearly for auxiliary transformers including transportation charges –(12samples/Visit)as per technical specification. |
| 4 | Furan analysis for transformers oil with yearly frequency including transportation charges(20samples/visit) including transportation charges as per technical specification | Furan analysis for transformers oil with yearly frequency including transportation charges(20samples/visit) including transportation charges as per technical specification |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender