Health and Family Welfare Government Departments Closing in 9 days TDR #56537530

Tender For Supply Installation Testing and Commissioning of Cctv Work For Construction Of Sub District Hospital Weir, Distt. Bharatpur.

Issued by Government Departments · Bharatpur, Rajasthan
Tender Value
24.66 Lakhs
Estimated cost
Bid Submission
10 Aug 2026
9 days left
EMD
49320
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bharatpur → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply Installation Testing and Commissioning of Cctv Work For Construction Of Sub District Hospital Weir, Distt. Bharatpur.

BOQ

Name of Work:- SITC of CCTV work for construction of Sub District Hospital Weir, Distt. Bharatpur.
Sl. No. Item Description
1SITC of IR IP Based 5 MP Dome camera : 1/2.8\\" Progressive CMOS, ICR, IR, 2560(H)xl920(V):25fps(P), 2.8/3.6 mm lens (As per site requirement) H 264,H265/MJPEG, dual-stream, 120dB WDR or better, 3D DNR, BLC, IR minimum 30 mtr, Provision for Support on-board storage up to 256 GB (SD card nor included), intrusion detection, Line crossing detection, Motion detection, Dynamic analysis, Alarm should be trigger on (Tampering alarm, Network disconnect, IP address conflict, Storage exception), security feature such as (password protection, privacy mask, watermark, IP address filtering, anonymous access), Open standard to support ONVIF (PROFILE S, PROFILE G), Metal Housing, Vandal-proof housing IP 67, DC 12V & PoE, Complete with Junction box for cable management Oerating Conditions : 20 °C - 50 °C or better. Model should be : CE, BIS ,FCC,ROHS compliance. The CCTV OEM should have CMMI Level 5 or above or equivalent setup cenification. The CCTV OEM should have its office and service/ support center in RajasthanAll as per pre approved by Engineer in charge.
2SITC of IR IP based 5 MP Bullet Camera 5 MP , Video Resolution: 2592(H)x1944(V) Pixels , I to @25 fps; Image Sensor: 1/2.8-inch CMOS; Built in Infra-Red: 40 to 50 mtr; High Dynamic Range- 120 dB WDR; Lense- 2.8/3.6 mm, H264,H265/MJPEG , provision for Support on-board storage up to 256 GB (SD card not included) , intrusion detection, Line crossing detection, Motion detection, Dynamic analysis, Alarm should be trigger on (Tampering alarm, Network disconnect, IP address conflict, Storage exception), security feature such as (password protection, privacy mask, watermark, IP address filtering, anonymous access), Open standard to support ONVIF (PROFILE S, PROFILE G), Metal Housing, Vandal-proof housing IP 67, DC 12V & PoE, Complete with Junction box for cable management Oerating Conditions : -30°C to + 70 °C or better. Onvif Profile S,G,Confirmant;Model should be : CE, BIS ,FCC,ROHS complianceThe CCTV OEM should have CMMI Level 5 or above or equivalent setup certificatione CCTV OEM should have its office and service/ support center in RajasthanAll per pre approved by Engineer in charge.
3Supply, Installation, Testing & Commissioning of 16 ch NVR Pre-licenced, NVR supports upto 40 TB HDD Support, l6ch IP inpUts; ; Support ANR technology; 320mbps incoming bandwidth, supports up to I2MP full channel recording; support H.265 compression; l6ch syncronised playback , l080p; support 3rd party cameras ONVIF type; 4K output; minimum 04 SATA HDD Slots; each slot should suppport upto IOTB HDD; Dual gigabit self adaptive Ethernet interface; serial inteface; USB interface; (all cameras and Storage-NVR should be of same make for the smooth functioning of the system).complete with mounting accessories & junction box (to be provided by OEM) for cable management. Model should be : Certificates of Compliance: UL, CEfFCC, BIS. The CCTV OEM should have CMMI Level 5 or above or equivalent setup certification. The CCTV OEM should have its office and service/ support center in RajasthanAll as per pre approved by Engineer in charge
4Supply, Installation, Testing & Commissioning of 32 ch NVR Pre-licenced, NVR supports upto 40 TB HDD Support, 32 ch IP inputs; ; Support ANR technology; 320mbps incoming bandwidth, supports up to I2MP full channel recording; support H.265 compression; l6ch syncronised playback @1080p; support 3rd party cameras ONVIF type; 4K output; minimum 04 SATA HDD Slots; each slot should suppport upto IOTB HDD; Dual gigabit self adaptive Ethernet interface; serial interface; USB interface; (all cameras and Storage-NVR should be of same make for the smooth functioning of the system).complete with mounting accessories & junction box (to be provided by OEM) for cable management. Model should be : Certificates of Compliance: UL, CE/FCC, BIS. The CCTV OEM should have CMMI Level 5 or above or equivalent setup certification. The CCTV OEM should have its office and service/ support center in RajasthanAll as per pre approved by Engineer in charge
5Supply, Installation, Testing & Commissioning of of 3.5\\" 6 TB SATA ,USB 3.0 Surveillance Hard Disk .All as per pre approved by Engineer in charge.
6Supply, Installation, testing and commissioning of BIS compliance Professional series Diagonal Screen size 43\\" LED with Resolution 3,840 x 2,160 (4K UHD) along with Static (Panel) Contrast Ratio (1300:1) or better with viewing angle of 178/178 degree with response time of 8ms along with HDMI In 2.0 - 2 nos., USB 2.0 nos., RS 232- 1 nos., RJ 45- lNos. with Built in Speaker(10W + 10W) , with high speed processor and android or other reputated operationg system along with 4 GB RAM along with all audio and video decoder, Stand-by / sleep / off mode power 0.5 watt, . All as per pre approved by Engineer in charge.
7Supply, Installation, Testing & Commissioning of 1 KVA 1 Phase Input,with IGBT Based Rectifier True Online Double Conversion Robust design Wide input voltage range: 160-300VAC @ 100% load (linearly derating to 50% load @ 100VAC input). Generator Compatible with Wide Input voltage window Double Conversion Efficiency >9l% & ECO mode efficiency up to 98% 100% load @ 0-40C operating temp. Active Input Power Factor Correction 0.99 O/P power factor 0.9 Inbuilt OVCD (Over Voltage Cut-off device) Fully conform coated PCBA adaptable to harsh environment Offer terminal blocker on 2K/3K rating to connect to big capacity equipment Digital Charger Technology provide 02-10 A charging current Easy understanding LCD for convenient installation setup with Minimum 60 minute battery back up (26AH x 3 Nos of SMF batteries branded and recommended by UPS OEM, battery stand and interlink FR PVC copper cable of appropriate size and lugs), with required cabling for incoming & outgoing connection. UPS should be NABL certified with CE, ROHS & BIS compliance. All as per pre approved by Engineer in charge.
8Supply, Installation, Testing & Commissioning of 2 KVA 1 Piiase 1nput,with GBT Based Rectifier True Online Double Conversion Robust design Wide input voltage range: 160-300VAC @ 100% load(linearly derating to 50% load @ 100VAC input). Generator Compatible with Wide Input voltage window Double Conversion Efficiency >91% & ECO mode efficiency up to 98% 100% load @ 0-40C operating temp. Active Input Powet' Factor Correction 0.99 O/P power factor 0.9 Inbuilt OVCD (Over Voltage Cut-off device) Fully conform coated PCBA adaptable to harsh environment Offer terminal blocker on 2K/3K rating to connect to big capacity equipment Digital Charger Technology provide 02-10 A charging current Easy understanding LCD for convenient installation setup with Minimum 60 minute battery back up (26AH x 6 Nos of SMF batteries branded and recommended by UPS OEM, battery stand and interlink FR PVC copper cable of appropriate size and lugs), with required cabling for incoming & outgoing connection. UPS should be NABL certified with CE, ROHS & BIS compliance. All as per pre approved by Engineer in charge.
9SITC of 4 port Giga PoE Switch with dual uplink : unmanaged PoE switch; 4X 10 /100/ 1000 mbps Base-T PoE: 1*10/100/1000 Base-T (Uplink) or 1*1000 Base-X (uplink): PoE Pouwer Consumption per Port: <30W; power budget: minimum 48 W: PoE Protocols: IEEE802.3af, IEEE802.3 at , Switching Capacity. 10 Gbps or better: MAC Table Size 2K or better working Temperature: -5°C-55°C; Power supply: DC48-57V Certificate ot compliance: CE/FCC. All as per pre approved by Engineer in charge.
10SITC of 8 port Giga PoE Switch with dual uplink : unmanaged PoE switch; 8X 10 /100/ 1000 mbps Base-T PoE: 2*10/100/1000 Base-T (Uplink) or 2*1000 Base-X (uplink): PoE Pouwer Consumption per Port: <30W; power budget: minimum 96 W: PoE Protocols: IEEE802.3af, IEEE802.3 at , Switching Capacity. 20 Gbps or better: MAC Table Size 2K or better working Temperature: -5°C-55°C; Power supply: DC48-57V Certificate ot compliance: CE/FCC. All as per pre approved by Engineer in charge.
11Supply . Installation. Testing and Commissioning of L2 managed Switch; l6X10 100, 1000 BASE-T port and with min 2x 1000/10000 BASE-X SFP (\Vith 2 SFP module for fiber Giga Connectivity); Total power budget: minimum 300W. Switching Capacity 56 GBPS or better; MAC Table 8K or betier: Rack mounting; Flow Control; QoS; 802.IQ Standard VLAN, fietu ork management: Wide u'orking temperature: -05-55°C; Lightning Protection Common mode 4KV; Certificate of compliance: CE/FCC, including making connections etc as required complete in all respect. All as per pre approx ed by Engineer in charge.
12Supply . Installation. Testing and Commissioning of L2 managed Switch; 24X10 100, 1000 BASE-T port and with min 4x 1000/10000 BASE-X SFP (\Vith 2 SFP module for fiber Giga Connectivity); Total power budget: minimum 350W. Switching Capacity 56 GBPS or better; MAC Table 8K or betier: Rack mounting; Flow Control; QoS; 802.IQ Standard VLAN, fietu ork management: Wide u'orking temperature: -05-55°C; Lightning Protection Common mode 4KV; Certificate of compliance: CE/FCC, including making connections etc as required complete in all respect. All as per pre approx ed by Engineer in charge.
13Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected by PVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.
14S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) 25MM PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required.
1525 mm Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56537530
AUTHORITY Government Departments
TENDER VALUE 24.66 Lakhs
LAST DATE 10-08-2026
Authority
Authority Name Medical And Health Services
Work Description Tender for Supply Installation Testing and Commissioning of Cctv Work For Construction Of Sub District Hospital Weir, Distt. Bharatpur.
Basic Detail
Tender No NIT No.09/2026-27 EE M and H DivBharatpur/
Bidding Type Tender
Location
City Bharatpur
State Rajasthan
Key Dates
Publish Date 18 Jul 2026
Submission Date 10 Aug 2026
Open Date 11 Aug 2026
Finance
Tender Value 24.66 Lakhs
Tender Fee 500
EMD 49320
Exemption Not Available
Document List
BOQ_1023758.xls
ebd8eb2c-1e31-4585-8129-38f221546375.html
Tendernotice_1 (29).pdf
Tendernotice_2 (3).pdf
Tendernotice_3 (2).pdf
Tendernotice_4.pdf
Tendernotice_5.pdf
Tendernotice_6.pdf
Tendernotice_7.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Aug 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1023758.xls

html

ebd8eb2c-1e31-4585-8129-38f221546375.html

pdf

Tendernotice_1 (29).pdf

pdf

Tendernotice_2 (3).pdf

pdf

Tendernotice_3 (2).pdf

pdf

Tendernotice_4.pdf

pdf

Tendernotice_5.pdf

pdf

Tendernotice_6.pdf

pdf

Tendernotice_7.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders