Tender For Repair And Maintenance Of Summer And Winter Appliances (Fans, Refrigerator, Ac, Water Coolers, Deep Freezers, Geysers And Desert Coolers Etc.) At N Area And Hallomajra Under Ge Chandigarh.

Issued by Statutory Bodies & Commissions/Committees · Chandigarh, Chandigarh
Tender Value
40 Lakhs
Estimated cost
Bid Submission
06 Aug 2026
5 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of Summer And Winter Appliances (Fans, Refrigerator, Ac, Water Coolers, Deep Freezers, Geysers And Desert Coolers Etc.) At N Area And Hallomajra Under Ge Chandigarh.

BOQ

Name of Work:- REPAIR AND MAINT OF SUMMER AND WINTER APPLIANCES (FANS, REFRIGERATOR, AC, WATER COOLERS, DEEP FREEZERS, GEYSERS AND DESERT COOLERS ETC.) AT N AREA AND HALLOMAJRA UNDER GE CHANDIGARH.
Sl. No. Item Description
1Taking down ceiling fans of 1200/1400mm sweep and make after disconnecting from ceiling rose, opening up, including greasing and overhauling after replacing unserviceable spairs like bearings, bushes, capacitors, ms clamp,rubeer reels with nut, bolt split pin, and shaft, sleeves, rewinding, testing, rehanging and making connection to ceiling rose Complete all as specified and as directed by Engineer-in-charge. Note: (i) Spares parts for replacement shall be measured and paid for seprately as supply only under respective items of BOQ. (ii) Technician of contractor shall visit door to door and attend complaints after take the complaints from E/M complaint cell in respective bldg in Md/OTM Accn and obtain their signatures of user after satisfactory complition of work (iii) rewinding of Fan will be done in 03 working days (iv) For every complaint not rectified within prescribed time limit, a penalty of Rs 500 per complaint shall be imposed (v) A workshop for ceiling fan winding shall be installed at N area complaint cell, The store space will be provided by the department.
2Taking down exhaust fans of any sweep and make after disconnecting, opening up, including greasing and overhauling after replacing unserviceable spairs like bearings, bushes, capacitors, ms clamp, nut, bolt and split pin, and shaft. sleeves, rewinding, testing, refixing and making connection to ceiling rose Complete all as specified and as directed by Engineer-in-charge. Note: (i) Spares parts for replacement shall be measured and paid for seprately as supply only under respective items of BOQ. (ii) Technician of contractor shall take the complaints from E/M complaint cell and rectified on the same day and obtain signatures of user after satisfactory complition of work (iii) rewinding of fan will be done in 03 working days (iv) For every complaint not rectified within prescribed time limit, a penalty of Rs 500 per complaint shall be imposed .
3M&L rewinding to ceiling fan motor of 1200mm sweep winded with winding machine with super enameled copper winding wire of existing size including insulated sleeves& paper , varnishing with ‘B’ class insulation varnish thimbles, connection with flexible cable of copper conducor of size 23/.0076 upto connector block ( winding wire exc 300 gm and n-exc 350gm ) Complete all as specified and as directed by Engineer-in-charge.
4M&L rewinding to ceiling fan motor of 1400mm sweep winded with winding machine with super enameled copper winding wire of existing size including insulated sleeves& paper , varnishing with ‘B’ class insulation varnish thimbles, connection with flexible cable of copper conductor cable of size 23/.0076 upto connector block ( winding wire exc 350 gm and n-exc 750gm ) Complete all as specified and as directed by Engineer-in-charge. Note for item No 3 & 4 :--(i) The cost of cutting & taking out to existing old winding wire shall be deemed to be included in the unit rate of this item. Nothing extra shall be entertained on this account.
5Supply and Fixing ceiling fan complete with blades, down rods, electric regulators, 230V, 1200mm sweep, min air delivery 210 CFM with service value 6.00 BEE, five star BLDC motor, with remote control speed control complete all as specified and as directed.
6Supply only Ball bearing suitable for celing fans of any sweep.
7Supply only Mild steel shaft suitable for celing fans of any sweep.
8Rewinding to exhaust / pedestal/ wall mounting fan motor of 225 to 380mm sweep winded with winding machine with super enameled copper winding wire of existing size including insulated sleeves , paper , varnishing with ‘B’ class insulation varnish, thimbles, connection with flexible cable of copper conductor of size 23/.0076 up-to connector block Complete all as specified and as directed by Engineer-in-charge.
9All as per above item No 08 here-in –before but 450 mm sweep Note for item No 8 & 9 :--(i) The cost of cutting & taking out to existing old winding wire shall be deemed to be included in the unit rate of this item. Nothing extra shall be entertained on this account(ii) Spare parts like as Ball bearings, Bush & shaft shall be measured & paid as Supply only separately under respective item No 10 to 12 of this schedule . Fixing charges of these spare parts shall be deemed to be included in the unit rate of this item without entertaining extra cost on this account.
10Supply only ball bearing suitable for 225/300/350/450 mm sweep exhaust / pedestal/ wall mounting fan
11Supply only gun metal bush suitable for 225/300/350/450 mm sweep exhaust / pedestal/ wall mounting fan
12Supply only mild steel shaft suitable for 225/300/350/450 mm sweep exhaust / pedestal/ wall mounting fan
13M&L circuit kit plate including diode, IC, transistor, rectifier and invertor as per existing make and model for BLDC remote/non-remote ceiling fan 1200/1400 mm sweep Complete all as specified and as directed by Engineer-in-charge.
14M&L lathe work for taking out bush from the lower body part of ceiling fan and replacing it with suitable size of ball bearing as per matching size to shaft making necessary bearing boring, cutting, greasing, polishing of shaft Complete all as specified and as directed by Engineer-in-charge.
15M&L replacement to unserviceable capacitor 4 mfd in lieu of provided with new capacitor dry type 4 mfd suitable for 240 volt AC Complete all as specified and as directed by Engineer-in-charge.
16M&L replacement to unserviceable capacitor 2.5 mfd in lieu of provided with new capacitor oil type 2.5 mfd suitable for 240 volt AC Complete all as specified and as directed by Engineer-in-charge.
17M&L replacement to unserviceable capacitor 3.15 mfd in lieu of provided with new capacitor oil type 3.15 mfd suitable for 240 volt AC Complete all as specified and as directed by Engineer-in-charge.
18Preparation surfaces, cleaning thoroughly with kerosene oil ceiling fans 1200mm/1400mm sweep to remove only dust and any type of spots and painted with synthetic enamel paint (white colour) with help of spray gun machine, including writing MES No, complete all as specified and as directed by Engineer-in-charge.
19M&L for replacement to unserviceable fan blades (set of three blades) suitable for 1200/1400mm sweep ceiling fans complete all as specified and as directed by Engineer-in-charge.
20M&L for replacement to unserviceable rusted MS rod up to 3 feet including clamp, nut, bolt, washer & split pin suitable for any sweep ceiling fan Complete all as specified and as directed by Engineer-in-charge.
21M&L for replacement to unserviceable rubber reels with new suitable for any sweep ceiling fan complete all as specified and as directed by Engineer-in-charge.
22M&L for replacement to unserviceable PVC canopy suitable for any sweep ceiling fan complete all as specified and as directed by Engineer-in-charge.
23Shifting only Exhaust fan any sweep,Single phase, 240 volts, 50 Hz, connecting up including provision of PVC insulated, unsheathed copper conductor flexible cable 3core, 23/0.0076 and fixed on wall by using 4 Nos, 100 mm long, 12 mm dia bolts, nuts and washers and grouted in wall in cm(1:3) including making opening in wall of suitable) size for exhaust fan & making good to disturbed surface of wall with PCC(1:2:4) Type –B-1 or Cement mortar CM(1:3) complete all as specified and as directed by Engineer-in-Charge.
24Supply and fixing PVC exhaust fan 300mm sweep, Single phase, 240 volts, 50 Hz, connecting up including provision of PVC insulated, unsheathed copper conductor flexible cable 3core, 23/0.0076 and fixed on wall by using 4 Nos, 100 mm long, 12 mm dia bolts, nuts and washers and grouted in wall in cm(1:3) including making opening in wall of suitable) size for exhaust fan & making good to disturbed surface of wall with PCC(1:2:4) Type –B-1 or Cement mortar CM(1:3) complete all as specified and as directed by Engineer-in-Charge.
25Replacement of exhust fan motor 450mm sweep,Copper wound,50Hzs,230 Volt complete all as directed.
26Replacement of exhust fan motor 300mm sweep,Copper wound,50Hzs,230 Volt complete all as directed.
27Replacement of exhust fan louvers suitable for 450mm sweep exhust fan complete.
28Replacement of exhust fan louvers suitable for 300mm sweep exhust fan complete.
29Replacement of exhust fan clamps with legs (Brackets) suitable for 450mm sweep exhust fan complete.
30Replacement of exhust fan clamps with legs (Brackets) suitable for 300mm sweep exhust fan complete.
31Taking down desert cooler of any make & size fixed at different site / location and repair to desert cooler to stop any type of leakage, tightening / replacing rusted screw nuts, bolts & washers with new of same size etc including floor cleaning, scraping all scales from internal & external surfaces and painted to desert cooler with two coats of synthetic enamel paint on external surface & black Japan paint on internal surfaces with help of spray gun machine including writing of MES/ SM No in 5cm height and re-fixing the desert cooler after necessary oiling and greasing of fan and water lifting pump at site/location complete all as specified and as directed by Engineer-in -Charge. NOTE : (i) Spare parts shall be measured & paid seperatly under respective item of this schedule (ii) Technician of contractor shall take the complaints from E/M complaint cell and rectified on the same day and obtain signatures of user after satisfactory complition of work (iii) rewinding of cooler will be done in working 03 days (iv) For every complaint not rectified within prescribed time limit, a penalty of Rs 500 per complaint shall be imposed.
32Rewinding to Desert cooler motor of any size winded with winding machine with super enameled copper winding wire of existing size including insulated sleeves , paper , varnishing with ‘B’ class insulation varnish, thimbles, connection with flexible cable of copper conductor of size 23/.0076 up-to connector block complete all as specified and as directed by Engineer-in-charge.
33Replacement of fan motor of 145 Watt 50 Hz’s suitable 230 volt AC.
34Replacement of submersiable Tulu pump / water fitting pump.
35Replacement of Wooden wool pads
36Replacement of 15mm bore High density polythene pipe
37Replacement of PVC Water distributor 3-way
38Replacement of Selector switch ( three speed )
39Replacement of PVC Bend right angle
40Replacement of 3-Pin plug top, 5 Amp, 230volt AC
41Replacement of Flexible cable copper conductor sizes 23/.0076, 3-core PVC Insulated sheathed
42Replacement of 15mm bore Ball valve with float ball PTMT
43Replacement of 15mm bore, 450mm to 600mm long PVC Connection pipe with PVC Union nut.
44Replacement of 15mm bore stop cock PTMT.
45M&L for Replacement of existing unserviceable MS steel stands of desert coolers at different locations with cooler stand made out MS angle iron 35mm x 35mm x 3mm thick embedded in wall with PCC (1:2:4) type B-1 block including applying two coat synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge.
46Taking down window type Air conditioner capacity 1.5 to 2.5 Ton strip opening, general cleaning of filter, washing complete unit with detergent and chemical including re-fixing in the same opening or shifted to other opening /room including making good the existing location of AC complete all as specified and as directed by Engineer-in-Charge. (i) Technician of contractor shall take the complaints from E/M complaint cell and rectified on the same day and obtain signatures of user after satisfactory complition of work (ii) Replacement of compressor, condenser unit, PCB work will be done in 03 working days (iii) For every complaint not rectified within prescribed time limit, a penalty of Rs 500 per complaint shall be imposed .
47All as per above item No 46 here-in-before but any split type Air Conditioner 1.5 to 2.5 Ton.
48All as per above item No 46 here-in-before but cassette/package type Air Conditioner 2.0/3.0 Ton.
49All as per above item No 46 here-in-before but cassette/package type Air Conditioner 11.00 Ton.
50All as per above item No 46 here-in-before but cassette/package type Air Conditioner 5.50 Ton.
51Taking out PCB unit from AC’s split / window / cassette type(including inverter type) of capacity 1.5/2/2.5/3 Ton carry to workshop for repair and refixing PCB unit after repair to existing AC complete all as specified and as directed by Engineer-in-Charge.
52S&F PCB/Mother Board Unit alongwith Remote Control Unit suitable for 1.5/2/2.5/3 Ton window/ Split/ cassette/ package Type Air Conditioning(including inverter type) complete all as directed.
53S&F PCB/Mother Board Unit alongwith Remote Control Unit suitable for 5.5 Ton package Type Air Conditioning(including inverter type) complete all as directed.
54S&F PCB/Mother Board Unit alongwith Remote Control Unit suitable for 11 Ton package Type Air Conditioning(including inverter type) complete all as directed.
55Disconnection and removing the unserviceable Display Unit and S&F Digital Display for indicating Temperature, Temperature Sensor for 1.5/2/3 Ton window/ Split/ cassette/ package Type Air Conditioning(including inverter type) complete all as directed.
56Disconnection and removing the Old unserviceable Copper Pipe between Indoor & Outdoor Unit and S&F New Copper Pipe of 1/2\\" dia or 1/4\\" dia connecting alongwith Insulation Sleeves to the existing position incl leak testing complete all as directed by Engineer in charge.
57Replacement of unserviceable sealed compressor of 1.5 Ton capacity window type AC with new sealed compressor of existing capacity & model including soldering of liquid /gas pipe ,cleaning & testing for leakage etc complete all as specified and directed by Engineer-in-charge.
58All as per above item No 57 here-in-before but 2.0 Ton capacity window type AC.
59All as per above item No 57 here-in-before but 1.5 Ton capacity split type AC (including inverter type).
60All as per above item No 57 here-in-before but 2.0 Ton capacity split type AC (including inverter type).
61All as per above item No 57 here-in-before but 2.5 Ton capacity split type AC (including inverter type).
62All as per above item No 57 here-in-before but cassette/package type Air Conditioner 5.50 Ton.
63All as per above item No 57 here-in-before but cassette/package type Air Conditioner 2.0/3.0 Ton . Note for item No 57 to 63:--- (i) Contractor shall be produced original purchase voucher of original manufacturer /authorized dealer and test certificate shall be of original manufacturer to the department along with payment of RAR/Final bill. (ii) Recharging of refrigerant gas shall be measured & paid separately under respective item of BOQ.
64S&F for replacement of unserviceable condenser unit with new of existing make and model suitable for split type AC 1.5 Ton capacity, complete all as specified and as directed by Engineer-in-Charge.
65All as per above item No 64 here-in-before but 2.0 Ton capacity split type AC(including inverter type)
66All as per above item No 64 here-in-before but cassette/package type Air Conditioner 2.0/3.0 Ton
67S&F for replacement unserviceable cooling coil unit with new of existing make and model suitable for window/split type AC 1.5 Ton capacity, complete all as specified and as directed by Engineer-in-Charge.
68All as per above item No 67 here-in-before but 2.0 Ton capacity split type AC (including inverter type)
69All as per above item No 67 here-in-before but cassette/package type Air Conditioner 2.0/3.0 Ton
70Recharging of suitable Gas for air conditioner unit window type/ split type/ cassette/package type 1.5 /2.0/2.5/3.0/5.5/11 ton complete including testing of leakage and testing the unit for satisfactory performance Complete all as specified and as directed by Engineer-in-Charge.
71S&F replacement of unserviceable thermostat switch with new of existing make and model suitable for window type/ split type/ cassette type AC 1.5/2 Ton capacity, complete all as specified and as directed by Engineer-in-Charge.
72S&F replacement of unserviceable starting capacitor 100 -120 mfd with new suitable for window type/ split type/ cassette type AC 1.5/2 Ton capacity & water cooler of any capacity, complete all as specified and as directed by Engineer-in-Charge.
73S&F replacement of unserviceable running capacitor 36 mfd with new suitable for window type/ split type/ cassette type AC 1.5/2/2.5 Ton capacity & water cooler of any capacity complete all as specified and as directed by Engineer-in-Charge.
74S&F replacement of unserviceable front grill with new as per existing suitable for window type/ split type AC 1.5/2/2.5.ton capacity complete all as specified and as directed by Engineer-in-Charge.
75S&F replacement of unserviceable blower motor with new blower motor suitable for window type AC of 1.5/2/2.5 Ton capacity as per exising capacity motor complete all as specified and as directed by Engineer-in-Charge.
76S&F replacement of unserviceable blower motor with new blower motor suitable for split type AC of 1.5/2/2.5 Ton capacity as per exising capacity motor complete all as specified and as directed by Engineer-in-Charge.
77S&F replacement of unserviceable cable with flexible PVC insulated copper conductor cable 3 core of size 70/0.0076 for AC of any capacity complete all as specified and as directed by Engineer-in-Charge.
78S&F replacement of unserviceable knob with new knob suitable for window type / split type AC 1.5/2Ton capacity Complete all as specified and as directed by Engineer-in-Charge.
79S&F replacement of unserviceable selector switch with new selector switch (ON/OFF five steps) suitable for window type / split type AC 1.5/2Ton capacity Complete all as specified and as directed by Engineer-in-Charge.
80S&F replacement of unserviceable air filter with new air filter suitable for window type / split type AC 1.5/2Ton capacity complete all as specified and as directed by Engineer-in-Charge.
81S&F replacement of unserviceable over load protector with new over load protector suitable for split type AC 1.5/2/2.5Ton capacity Complete all as specified and as directed by Engineer-in-Charge.
82Carried out of Leak Proof Test for detection of leakage of gas from the cooling unit & Copper Tubing for Indoor/Outdoor Unit of Air conditioner, Refrigerator, Water Cooler with liquid nitrogen gas and arresting by gas welding method complete and charging of refrigerant into the Air conditioner/Refrigerator/Water Cooler complete. Note :- The leakage to be observed for 24 Hours and after confirmation only the refrigerant is to be provided to the unit.
83Disconnection and removing the old unserviceable Outdoor Stand and S&F New Outdoor Stand made of Iron bracket to accomodate the air conditioner along with fixing materials complete all as specified and as directed by Engineer-in-Charge.
84Uninstalling 1.5/2.0 Ton window/Split Air Conditioner from one place and installing to another place including cutting and making opening in wall or cutting to steel window / glass pane make a opening for fixing of AC’s of any capacity and cover unused space with 4 mm thick PVC sheet fixed to wooden / steel frame with mild steel screw/nails including making good existing location of AC complete all as specified and as directed by Engineer-in-Charge.
85Taking down carefully dismantling voltage stabilizer of capacity 3 KVA to 5 KVA, single phase 240 volt AC of any make and any size opening up for inspection necessary repair and replacement of worn out/defective spare parts, rewinding of main transformer with supper enameted copper wire of existing gauge and weight reassembling, connecting up, testing etc complete all as directed by Engineer-in-Charge (Necessary spare parts required for replacement shall be measured and paid for separately as supply only) and fixing is included under this item.
86S&F relay condenser and electronic circuit suitable for voltage stabilizer of capacity 3 KVA to 5 KVA of existing make and size complete all as specified and as directed by Engineer-in-charge.
87Disconnecting, opening and taking out unserviceable sealed compressor of water cooler of capacity 150/180 litres and replaced with new sealed compressor of existing capacity & model including soldering of liquid /gas pipe ,cleaning the system arresting the leakage etc complete all as specified and as directed by Engineer-in-charge. Note : (i) Technician of contractor shall take the complaints from E/M complaint cell and rectified on the same day and obtain signatures of user after satisfactory complition of work (ii) replacement of compressor will be done in 03 working days (iii) For every complaint not rectified within prescribed time limit, a penalty of Rs 500 per complaint shall be imposed.
88All as per above item No 87 here in before but water cooler of capacity 40/80 litres. Note for item No 87 & 88:(i) Contractor shall be produced original purchase voucher of original manufacturer /authorized dealer and test certificate shall be of original manufacturer to the department along with payment of RAR/Final bill. (ii) Recharging of refrigerant gas shall be measured &paid separately under respective item of BOQ.
89Cleaning the system with CTC and charging the refrigerant suitable gas including replacing strainer and rectification of leakage of the system from water cooler of150 litres capacity complete all as specified and as directed by Engineer-in-charge.
90All as per above item No 89 here-in-before but water cooler of capacity 40/80 litres
91S&F for internal wiring for water coolers 150/80/40 ltr capacity with PVC insulated unsheathed flexible copper conductor cable single core size 40/0.0076 fixed with terminal clips etc including replacement of screws, washers etc required for fastening to body etc complete all as specified and as directed by Engineer-in-charge.
92S&F replacement of unserviceable starting relay assembly with new starting relay assembly suitable for water cooler of 150 litre capacity as per exisitng make Complete all as specified and as directed by Engineer-in-Charge.
93All as per above item No 92 here-in-before but water cooler of capacity 40/80 litre
94S&F replacement of unserviceable over load protector with new over load protector suitable for water cooler of 150 litre capacity as per exisitng make Complete all as specified and as directed by Engineer-in-Charge.
95All as per above item No 94 hereinbefore but water cooler of capacity 40/80 litre
96S&F replacement of unserviceable fan motor with new fan motor suitable for water cooler of 150 litre capacity as per exisitng make Complete all as specified and as directed by Engineer-in-Charge.
97All as per above item No 96 hereinbefore but water cooler of capacity 40/80 liter
98M&L 15 mm bore self closing tap push type cast copper alloy chromium plated fixed to water cooler as in repair Complete all as specified and as directed by Engineer-in-Charge.
99M&L cleaning to water coolers upto 150 ltrs capacity internal & external surfaces of suitable repairs to body & stop leakage etc, replacing unserviceable nut bolts & washers etc including preparation of external surfaces and bottom body and painted with anticorrosive synthetic enamel paint with help of spray gun machine and writing SM / MES No in 5cm height Complete all as specified and as directed by Engineer-in-Charge.
100All as per above item No 99 here-in-before but water cooler of capacity 40/80 liter
101S&F replacement of unserviceable thermo-state switch with new thermo-state switch suitable for water cooler any capacity as per exisitng make Complete all as specified and as directed by Engineer-in-Charge.
102Disconnecting & opening of deep freezers and taking out unserviceable sealed compressor of capacity 300/320 liters and replacing with new sealed compressor of existing capacity & model including soldering of liquid /gas pipe ,cleaning the system arresting the leaking etc complete all as specified and as directed by Engineer-in-charge. Note for item No 101 & 102: (i) Contractor shall be produced original purchase voucher of original manufacturer /authorized dealer and test certificate shall be of original manufacturer to the department along with payment of RAR/Final bill. ( ii) Recharging with refrigerant gas shall be measured & paid separately under respective item of BOQ. (iii) Technician of contractor shall take the complaints from E/M complaint cell and rectified on the same day and obtain signatures of user after satisfactory complition of work (iv) Replacement of compressor will be done in 03 working days (v) For every complaint not rectified within prescribed time limit, a penalty of Rs 500 per complaint shall be imposed.
103All as per above item No 102 here-in-before but 205 Ltr.
104Cleaning the system with CTC and charging the refrigerant suitable gas including replacing strainer and rectification of leakage of the system from deep freezer upto 320 litres capacity complete all as specified and as directed by Engineer-in-charge.
105M&L for internal wiring for deep freezer upto 320 ltr capacity with PVC insulated unsheathed flexible copper conductor cable single core size 40/0.0076 fixed with terminal clips etc including replacement of screws, washers required for fastening to body etc complete all as specified and as directed by Engineer-in-charge.
106S&F replacement of unserviceable starting relay assembly with new starting relay assembly suitable for deep freezer water cooler of 320 litre capacity as per existing make Complete all as specified and as directed by Engineer-in-Charge.
107S&F replacement of unserviceable over load protector with new over load protector suitable for deep freezer 320 litre capacity as per existing make Complete all as specified and as directed by Engineer-in-Charge.
108S&F replacement of unserviceable fan motor with new fan motor suitable for deep freezer upto 320 liter capacity as per existing make Complete all as specified and as directed by Engineer-in-Charge.
109Disconnecting & opening refrigerator of capacity 210/320 litre and taking out unserviceable sealed compressor and replacing with new sealed compressor of existing capacity & model including soldering of liquid /gas pipe ,cleaning the system & the leakage etc complete all as specified and as directed by Engineer-in-charge.
110All as per above item No 109 here-in-before but 180 litres
111Recharging of suitable gas in refrigerant cap 180/210/320 litre complete including testing of leakage and testing the unit for satisfactory performance Complete all as specified and as directed by Engineer-in-Charge.
112Replacement of freezer door plastic with tension spring as per existing model suitable 160/200 liter capacity.
113Replacement of Fruit /vegetable tray of any capacity as per existing make & model
114Replacement of Pigmy lamp (bulb)
115Replacement of Door liner ( Plastic ) for upto 310 liter capacity
116Replacement of Door magnetic gaskest for upto 310 litre capacity.
117Replacement of Relay box type for any capacity.
118Replacement of over load protector for any capacity.
119Replacement of toughned glass (Vegitable tray cover) refrigerator freezer of capacity 180 to 320 ltr Complete all as specified and as directed by Engr-in-Charge. .
120Disconnecting & taking down unserviceable geyser of 25/50 litre capacity of any make from the wall and opening carefully including descaling the inner surface by scrapping, carrying out soldering/ brazing/gas welding to prevent the leakage, filling of glass wool & replacement of any other defective spares , including replacement of required number of stainless steel screws, nuts & bolts,assembling the the same after repair work and fixing in its orginal place, connecting to water mains and electric supply, testing after repairs, complete all as specified and as directed by Engineer-in-charge. Note :spare parts and glass wool shall be measured and paid separtaly under respective items of BOQ. (i) Technician of contractor shall take the complaints from E/M complaint cell and rectified on the same day and obtain signatures of user after satisfactory complition of work (ii) replacement of inner tank and assembly work will be done in 03 working days (iii) For every complaint not rectified within prescribed time limit, a penalty of Rs 500 per complaint shall be imposed .
121S&F replacement of unserviceable Stain less steel inner tank of 25 liter capacity geysers of existing make & model including testing after assembling & fixed at site complete all as specified and as directed by Engineer-in-Charge.
122All as per above item No 121 here-in-before but 50 ltr capacity.
123Replacement of unserviceable heating element with new heating elements screw/or stud type ISI marked 2000 watt 230 volts AC single phase including necessary washer, screw, nuts bolts etc complete and all as specified.
124Replacement of unserviceable heating element with new heating elements screw/or stud type ISI marked 3000 watt 230 volts AC single phase including necessary washer, screw, nuts bolts etc complete and all as specified.
125Replacement of unserviceable Geyser thermostat switch any type/size with new thermostat switch ISI marked of range 0-100 degree centigrade, adjustable between 70 to 100 degree centigrade with necessary washer, screws nut etc complete and all as specified.
126Supply and fix in repairs 06/08/09 hole Assembly for water heateer ISI Marked complate all as specified and as directed.
127Replacement of unserviceable Safety valve complate all as specified and as directed.
128Replacement of unserviceable indicator lamp assy with new indicator lamp assy 230 volts square or round suitable for any type or make of Geyser including connecting complete and all as specified.
129Replacement of unserviceable Gun metal non return valve ,15 mm bore complate all as specified and as directed.
130S&F PVC connection 450mm long for cold / hot water heavy duty 15mm bore coupling or nuts complate all as specified and as directed.
131Replacement of bottom/top plates made out of MS sheet of 1mm thick made to shape of required size factory made complete suitable size of 25/50 Ltr Geyser fitted with machining screws duly painted with synthetic enamelled white paint complete and all as specified.
132S&F sheet metal enclosure with single pole and neutral with two pin and earth plug socket including 20Amp 240 Volt including MCB SP,20Amp(C-series) as in repair complete all as specified and as directed by Engineer-in-Charge.
133Replacement of Rubber O ring /gaskit for 25 ltrs complate all as specified and as directed.
134M&L for preparation of surface of geyser of 25 ltrs capacity of any make by scrapping to existing paint, filling cavities with filler (Putty) after cleaning of dust etc and applying synthetic enamel paint over a coat of red oxide primer with spray gun and writing the MES No with black paint complete all as specified and as directed by Engineer-in-Charge.
135M&L for preparation of surface of geyser of 50 ltrs capacity of any make by scrapping to existing paint, filling cavities with filler (Putty) after cleaning of dust etc and applying synthetic enamel paint over a coat of red oxide primer with spray gun and writing the MES No with black paint complete all as specified and as directed by Engineer-in-Charge.
136S&F replacement of unserviceable cable with flexible PVC insulated copper conductor cable 3 core of size 40/0.0076 for AC of any capacity complete all as specified and as directed by Engineer-in-Charge .
137Taking down carefully unserviceable point wiring and M&L for Point wiring complete with 1.5 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non-metallic PVC conduit and conduit accessories fixed on surface of wall/ceilings or concealed etc, including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor for earth continuity and connected to common earth dolly concealed in wall on top for housing the switches, socket outlet etc all as specified and as directed for One 3 pin socket outlet 5 Amps on independent board .(for Desert Coolers)
138All as per Item No 137 here in above but for One ceiling fan/ exhaust fan point controlled by one, one way 5 Amps switch
139Taking down carefully unserviceable point wiring and M&L for Point wiring complete with 4 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non-metallic PVC conduit and conduit accessories fixed on surface of wall/ceilings or concealed etc., including provision of PVC insulated 4 Sqmm FRLS cable with copper conductor for earth continuity and connected to common earth dolly concealed in wall on top for housing the switches, socket outlet etc all as specified and as directed for One 3 pin socket outlet 5 Amps on independent board. (for geyser & AC Point)
140Taking down carefully unserviceable point wiring and M&L for Point wiring complete with 2.5 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit and conduit accessories fixed on surface of wall/ceilings or concealed etc., including provision of PVC insulated 2.5 Sqmm FRLS cable with copper conductor for earth continuity and connected to common earth dolly and modular type metal boxes concealed in wall , modular cover plates with frames on top for housing the switches, socket outlet etc all as specified and as directed for one switch socket outlet 15 Amps on independent board complete all as specified and as directed by Engineer-in-charge.(Water coolers and Refrigerators)
141Supply and Fixing modular switch socket combination flush type universal 2 in 1, 3 pin 6 Amps
142Supply and Fixing modular switch socket combination flush type universal 2 in 1, 3 pin 16 Amps
143Supply and fix MCB SPN 230 volts 32 Amps with 10KA breaking capacity.
144Supply and fix MCB SP 230 volts 16/20 Amps with 10KA breaking capacity.
145Supply and fix MCB DB SPN 4 way double door with 200 amps rated bus bar complete all as spfd and directed.
146Disconnection and removing the unserviceable 3X1.5 Sqmm PVC insulated unsheathed cable from the existing conduit and M&L for 3X1.5 Sqmm PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor drawn in the existing metal/ PVC conduit & Casing capping including connecting of the ends into the switch / socket/ DB complete. Note : Three runs of cable measured as one unit.
147All as per Item No 146 here in above but of 3X2.5 Sqmm.
148All as per Item No 146 here in above but of 3X4 Sqmm.
149All as per Item No 146 here in above but of 3X6 Sqmm.
150Disconnection and removing the unserviceable regulator and Supply and Fixing step type electronic fan regulator of capacity 100 watts 230 volts for ceiling / exhaust fan flush type.
151Disconnection and removing the unserviceable ceiling rose and S&F Ceiling rose 3 terminal 5 Amps 230 volts PVC/Polycarbonate, insulated body complete all as spfd and directed.
152Disconnection and removing the unserviceable casing caping conduit and S&F PVC casing caping of size 20mm including cut to shape and size to match the existing conduits suitable for LT electric supply along with necessary fixing arrangements complete all as spfd and directed.
153M&L for 4mm thick PVC sheet of white colour including,cutting & fixing around AC’s / Desert cooler for insulation purposes complete all as specified and as directed by Engineer-in-Charge. Note :-- PVC Sheet shall be measured & paid equal to window opening without deduction of cutting area for grill opening for desert cooler & AC .
154Supply and fixing and testing in repairs split type air condioner 5 star rating indoor unit having hot & cold single phase 220 volt complete of capacity 2 ton Installation includes copper tubing as reguired up to 10 mtr and providing seasoning tape etc. and making good disturbed surfaces complete as directed by Engineer in Charge
155Supply and fixing and testing in repairs split type air condioner 5 star rating outdoor unit having hot & cold single phase 220 volt complete of capacity 2 ton Installation includes copper tubing as reguired up to 10 mtr and providing seasoning tape etc. and making good disturbed surfaces complete as directed by Engineer in Charge
156Supply and fixing and testing in repairs split type air condioner 5 star rating indoor unit having hot & cold single phase 220 volt complete of capacity 1.5 ton Installation includes copper tubing as reguired up to 10 mtr and providing seasoning tape etc. and making good disturbed surfaces complete as directed by Engineer in Charge.
157Supply and fixing and testing in repairs split type air condioner 5 star rating outdoor unit having hot & cold single phase 220 volt complete of capacity 1.5 ton Installation includes copper tubing as reguired up to 10 mtr and providing seasoning tape etc. and making good disturbed surfaces complete as directed by Engineer in Charge.
158Note: For the purpose of arriving at lumpsum amount, the amount of credit schedule i.e Sch 'A' section II (i.e Rs 1,71,457.00 shall be deducted from the total amount arrived.
159Total of Schedule 'A' Rs. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56536901
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40 Lakhs
LAST DATE 06-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair And Maintenance Of Summer And Winter Appliances (Fans, Refrigerator, Ac, Water Coolers, Deep Freezers, Geysers And Desert Coolers Etc.) At N Area And Hallomajra Under Ge Chandigarh.
Basic Detail
Tender No GE/CHD/T-47/2026-27
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 18 Jul 2026
Submission Date 06 Aug 2026
Open Date 08 Aug 2026
Finance
Tender Value 40 Lakhs
Tender Fee 500
EMD 80000
Exemption Available
Document List
BOQ_872785.xls
d80a4ca0-9c4f-4c94-87a3-43fc1af5d8a4.html
TENDER47.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Aug 08, 2026

Bid Opening Date

Technical bids will be opened and evaluated.