Tender For Repair And Maintenance Of Water Supply Installations, Narmada Water Supply Line Alongwith Certain Other Water Supply Items Of Age E/M And Age B/R-Ii Under Ge(A) Bhuj.
Tender Value
36.99 Lakhs
Estimated cost
Bid Submission
08 Aug 2026
15 days left
EMD
73980
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kachchh → Gujarat
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance Of Water Supply Installations, Narmada Water Supply Line Alongwith Certain Other Water Supply Items Of Age E/M And Age B/R-Ii Under Ge(A) Bhuj.
BOQ
| Sl. No. | Item Description |
| 1 | M&L for making RCC pillar 600X400mm of height 1.50mtr to 2.0mtr (0.50m to 0.80m depth below GL) and base of size 700x500x200mm with top flange for arresting water supply pipe lines complete all as specified and directed. |
| 2 | Following nomenclature are add on this above :-(a) Excavation below existing strata as required depth in soft / loose soil / SDR by mechanical means(b) 100mm PCC 1:4:8 type D2 using 40mm graded stone aggregate below pedestal of size 700mmx500mm.(c ) RCC nominal mix 1:1.5:3 (20mm graded aggregate) in pillar and base.(d) 12mm dia vertical bar 10 Nos for pillar and 12mm dia bar at 200mm C/C bothway in base of pillar.(e) 8mm dia bar for stirrups 125mmc/c for pillar/coloumn.(f) Plywood / Steel form work for pillar and square base.(g) Site clearance 3m in all around the pillar/post(h) Dewatering if required.(j) MS flat iron 50mm wide and 6mm thick approx 1m length for each pillar with required nuts and bolts. |
| 3 | Note :-(a) Working place in foul condition approx depth from existing ground level upto 6m.(b) Working length, approx 4km(c ) Shifting of construction materials manually / mechanically at contractor end.(d) Arrangements of dewatering equipment also at the end of contractor.(e) Dumping of construction materials at different location as per feasibility by the contractor.(f) Deployment of Crane/JCB / Tractor trolley / other mechanical means for access on site at the only arranged by the contractor.(g) Department will not be responsible in case of theft(h) Electricity and water will not be supplied by the MES(j) Execution site is available minimum upto 1000m from service road.(k) Site is available in steep slop approx. 6mtr from natural ground level.(l) RCC pillar will be made as sample matched which is existing.(m) All are above quoted in deemed rates separately will not be measured / paid. |
| 4 | M&L for making RCC pillar 600X400mm of height 2.00mtr to 2.50mtr (0.50m to 0.80m depth below GL) and base of size 700x500x200mm with top flange for arresting water supply pipe lines complete all as specified and directed. |
| 5 | Following nomenclature are add on this above :-(a) Excavation below existing strata as required depth in soft / loose soil / SDR by mechanical means.(b) 100mm PCC 1:4:8 type D2 using 40mm graded stone aggregate below pedestal of size 700mmx500mm(c ) RCC nominal mix 1:1.5:3 (20mm graded aggregate) in pillar and base.(d) 12mm dia vertical bar 10 Nos for pillar and 12mm dia bar at 200mm C/C bothway in base of pillar.(e) 8mm dia bar for stirrups 125mmc/c for pillar/coloumn.(f) Plywood / Steel form work for pillar and square base.(g) Site clearance 3m in all around the pillar/post(h) Dewatering if required.(j) MS flat iron 50mm wide and 6mm thick approx 1m length for each pillar with required nuts and bolts |
| 6 | Note :-(a) Working place in foul condition approx depth from existing ground level upto 6m.(b) Working length, approx 4km(c ) Shifting of construction materials manually / mechanically at contractor end.(d) Arrangements of dewatering equipment also at the end of contractor.(e) Dumping of construction materials at different location as per feasibility by the contractor.(f) Deployment of Crane/JCB / Tractor trolley / other mechanical means for access on site at the only arranged by the contractor.(g) Department will not be responsible in case of theft(h) Electricity and water will not be supplied by the MES(j) Execution site is available minimum upto 1000m from service road.(k) Site is available in steep slop approx. 6mtr from natural ground level.(l) RCC pillar will be made as sample matched which is existing.(m) All are above quoted in deemed rates separately will not be measured / paid. |
| 7 | Disconnecting the water mains from the suction and delivery pipe line of serviceable centrifugal pump sets/open well pump set of any description and in any position, any capacity and taking out pump set / motor from the base frame including disconnecting all electric connections and foundation, nuts and bolts. and reassembling the pump and motor of capacity from 5 HP upto 20 HP capacity, ensuring proper alignment of pump and motor, fixing in position, connecting to existing system and electric connection and testing at site on full load to the entire satisfaction of the complete all as specified and directed. |
| 8 | Disconnecting the water mains from the suction and delivery pipe line of serviceable centrifugal pump sets/open well pump set of any description and in any position, any capacity and taking out pump set / motor from the base frame including disconnecting all electric connections and foundation, nuts and bolts. and reassembling the pump and motor of capacity from 25 HP upto 50 HP capacity, ensuring proper alignment of pump and motor, fixing in position, connecting to existing system and testing at site on full load to the entire satisfaction complete all as specified and directed. |
| 9 | Disconnecting the water mains from the suction and delivery pipe line of serviceable centrifugal pump sets/open well pump set of any description and in any position, any capacity and taking out pump set / motor from the base frame including disconnecting all electric connections and foundation, nuts and bolts. and reassembling the pump and motor of capacity from 75 HP upto 120 HP capacity, ensuring proper alignment of pump and motor, fixing in position, connecting to existing system and testing at site on full load to the entire satisfaction of the complete all as specified and directed. |
| 10 | Dismantaling of existing MS iron frame and PCC foundation of Pump set from capacity 5 HP and upto 20 HP,removing all grouted nuts,bolts etc and removing the dismanatal PCC dabries and deposited at specified location complete all as specified and directed. |
| 11 | Dismantaling of existing MS iron frame and PCC foundation of Pump set from capacity 25 HP and upto 50 HP,removing all grouted nuts,bolts etc and removing the dismanatal PCC dabries and deposited at specified location complete all as specified and directed. |
| 12 | Dismantaling of existing MS iron frame and PCC foundation of Pump set from capacity 75 HP and upto 120 HP,removing all grouted nuts,bolts etc and removing the dismanatal PCC dabries and deposited at specified location complete all as specified and directed. |
| 13 | M&L for PCC base (civil work PCC 1:1.5:3) as per existing specification and required size for pump set installation from 5 HP and upto 20 HP,including all reqired material and grounting nuts,bolts,washer and anchors etc of required size for holding/tighted of pump set complete all as specified and directed. |
| 14 | M&L for PCC base (civil work PCC 1:1.5:3) as per existing specification and required size for pump set installation from 25 HP and upto 50 HP,including all reqired material and grounting nuts,bolts,washer and anchors etc of required size for holding/tighted of pump set complete all as specified and directed. |
| 15 | M&L for PCC base (civil work PCC 1:1.5:3) as per existing specification and required size for pump set installation from 75 HP and upto 120 HP,including all reqired material and grounting nuts,bolts,washer and anchors etc of required size for holding/tighted of pump set complete all as specified and directed. |
| 16 | M&L in replacement of Pump set base frame made out of angle iron structure as per existing size of cap 5 HP and upto 20 HP and complete installtaion of pump set on new base frame including testing ans tighteing of grounted nuts ,bolts complete all as specified and directed. |
| 17 | M&L in replacement of Pump set base frame made out of angle iron structure as per existing size of cap 50 HP and upto 25 HP and complete installtaion of pump set on new base frame including testing ans tighteing of grounted nuts ,bolts complete all as specified and directed. |
| 18 | M&L in replacement of Pump set base frame made out of angle iron structure as per existing size of cap 75 HP and upto 120 HP and complete installtaion of pump set on new base frame including testing ans tighteing of grounted nuts ,bolts complete all as specified and directed. |
| 19 | M&L for white wash of all new foundation and paint for MS iron base frame of any size and capacity complete all as specified and directed. |
| 20 | M&L for painting on suction and dischare line of water supply for pump sets of any cap and size complete all as specified and directed. |
| 21 | Supply and fixing LED street light fitting 35 Watt 230 volt AC outdoor type with high poressure die cast aluminum hoisting and heat retardent complete with driver lamp bracket with impact and corrosion resistant including thermal management in multipal optics complete with IP65/66 protection complete all as specified and directed. |
| 22 | Supply, Install, connecting, commissioning and testing of out door operation LT Panel Board cubical typy, Factory fabricated and made out of 3.0 mm thick CRCA sheet weather, dust and vermin proof. The panel board shall have compartment for each out going,opening both front and back with shutter duly hinged and locking arrangement . The outer dimension of panel board shall be suitable for housing following fittings and fixtures given here in after with proper clearence for maintenance as directed, The Panel shall be painted with two coats of synthetic enamelled paint over a coat of Zinc crome Oxide paint both internally and externally. Necessory holes shall be kept for in coming and out going cable entry and all holes shall be provided with cable Gland of brass ( size of glands as per site requirement ) . The Panel board shall have Copper bus bar of capacity 400 Amps for 3 phase 4 wire system. incl supply and fixing of following:- |
| 23 | INCOMINGa) Moulded case circuit Breaker (MCCB) , AC 415 Volts, 4 Pole , Current rating 250 Amps, Thermal setting -( 70 to 100 %), Breaking capacity - Icu at 415 Volts : 35 KA:- Qty = 1 Nob) Digital Ampere meter type 96mm x 96mm. flush type, Having measuring range 0 to 1000 Amps, including CT with CTR 1000:5 complete = 1 setc) Selector switch for Amp meter with measuring facility phase current and line current both. = 1 Nod) Digital Volt meter 96mm x 96mm flush type with scale 0 to 500 Volt. = 1 Noe) Indicator lamp Red, yellow and Blue, LED type = 3 Nos |
| 24 | OUTGOING a) Moulded case circuit Breaker (MCCB) , AC 415 Volts, 4 Pole , Current rating 125 Amps, Thermal setting -( 70 to 100 %), Breaking capacity - Icu at 415 Volts : 25 KA:- Qty = 2 No b) Moulded case circuit Breaker (MCCB) , AC 415 Volts, 4 Pole , Current rating 100 Amps, Thermal setting -( 70 to 100 %), Breaking capacity - Icu at 415 Volts : 55 KA:- Qty = 1 No c) MCB TPN 32 Amps 415 Volts supply= 3 No |
| 25 | NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysAug 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender