Tender for Periodical Electrical Day To Day Maintenance Works For A Period Of One Year At G V Raja Sports School, Mylom
BOQ
| Sl. No. | Item Description |
| 1 | Electrical Maintenance |
| 2 | 1.23.1 Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.5/6 amps switch |
| 3 | 1.23.3 Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.15/16 amp switch |
| 4 | 1.23.4 Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.3 pin 5/6 amp socket outlet |
| 5 | 1.23.5 Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.6 pin 15/16 amp socket outlet |
| 6 | 2.10.1 Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 7 | 2.10.4 Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole |
| 8 | 2.15.2 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps |
| 9 | OD86424/2025-2026 Supply, Installation, testing and commissioning of pre-wired, 12W recess/ Surface mounting round LED down light fitting complete with all accessories directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. Make : Phillips, Crompton Greaves, Bajaj, Lucker or approved by engineer in charge |
| 10 | OD86429/2025-2026 Supply and installation of pre-wired 20W LED batten fitting complete with all accessories and tube etc directly on ceiling/wall, including connection with 1.5sqmm FRLS PVC insulated,copper conductor single core cable and earthing etc as required |
| 11 | OD86458/2025-2026 Engaging electricians as per the direction of Engineer in charge as required |
| 12 | OD86448/2025-2026 Servicing of 400mm wall mounted fan including disconnecting the pull switch nylon cord and re-installation of wall fan without speed control as instructed in Engineer-in charge |
| 13 | OD86645/2025-2026 Supply and Installation of 400 mm size wall mounting oscillating type fan having three speed control, oscillation control at bottom and suitable for operation on single phase 230 volt, 50Hz AC supply complete with continuous duty motor, front and rear gaurds and all accessories as required complete.(Make: Crompton, Bajaj, Orient or Approved by engineer in charge) |
| 14 | 2.13.2 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 15 | Electrical LT Outdoor Works |
| 16 | 90.15.4.3 Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 17 | HVAC Repair |
| 18 | OD86549/2025-2026 Servicing of 1.5 Ton AC units including the compressor, fan motor, evaporator unit and checking the filter units and filling R22 gas required with all accessories for a period of one year |
| 19 | OD86550/2025-2026 Servicing of 5.5 Ton Ductable AC units including the compressor, fan motor, evaporator unit, PC board checking and cleaning the air filter units and air duct diffuser and filling R22 gas required with all accessories for a period of one year |
| 20 | OD86554/2025-2026 Servicing of 8.5 Ton Ductable AC units including the compressor, fan motor, evaporator unit, PC board checking and cleaning the air filter units and air duct diffuser and filling R22 gas required with all accessories for a period of one year |
| 21 | UPS Service |
| 22 | OD86556/2025-2026 Servicing of 5 kVA UPS including the tighten the all power connection at the input and output terminals of the circuit breaker and the power board, checking the terminal post and also check the fuses on the rectifier and inverter sides and refilling the battery as required with all accessories is required for a period of one year |
| 23 | Panel works,Transformer and Diesel Generator |
| 24 | OD86569/2025-2026 Servicing of 160KVA, 415V, 3Phase 1500rpm, 0.80 pf, water-cooled floor-mounted Diesel Generator set with acoustic enclosure(outdoor duty) including checking the batteries & battery charger, device for avoiding/ absorbing moisture content, fuel tank, radiator, control wiring, filling of lubricating oil, Oil Filter, Diesel Filter, Coolant, Timing cover oil seal, Removing dust and carbon particles, greasing/ lubrication of parts, and testing of the Diesel Generator with all accessories complete as required for a period of one year |
| 25 | OD86577/2025-2026 Servicing of 160 kVA Dry type 1100/433V indoor Transformer including checking the contacts and bushing of the LT/HT Side. Removing dust and carbon particles, greasing/ lubrication of parts and testing of transformer with all accessories complete as required for a period of one year |
| 26 | OD86578/2025-2026 Servicing of MSB panel and SSB, Metering panel checking of proper closing of all pole, contacts and checking IR between phase and earth in an open and closed condition with all accessories complete as required for a period of one year Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysJul 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender