Tender for Tender for Janpad Bareilly Main Rohilkhand Nahar Khand Antrat Bahari Main Inspection Bhavan Renovated, Renovated And Constructed The Jiledari Kaaraaye.
Tender Value
6.09 Crore
Estimated cost
Bid Submission
30 Jul 2026
2 days left
EMD
12.19 Lakhs
Bank guarantee accepted
Document Fee
2715
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bareilly → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Janpad Bareilly Main Rohilkhand Nahar Khand Antrat Bahari Main Inspection Bhavan Renovated, Renovated And Constructed The Jiledari Kaaraaye.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling brick work or stone work and cement concrete in cement mortar and including stacking of material with in a distance of 60 m. as per direction of Engineer-in-charge & also including all cost of material, labour & T&P etc. complete. |
| 2 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 3 | Earth work in foundation in dry ordinary soil (loam clay or sand) including lift up to 1.5 meter and lead up to 30 meter and including back filling, watering and ramming of excavated earth into the trenches or into the space between the structure and the sides of foundation trenches or into the plinth with removal and disposal or surplus earth as directed by the Engineer-incharge up to a distance of 30M from the foundation trenches:(Building) |
| 4 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km . From the site of work & including watering , dressing etc. Rate includes cost of all materials, labour and T&P etc. required for proper completion of the work. (including royalty) |
| 5 | Providing and Laying PCC 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 6 | Centering and shuttering inclding strutting , propping etc and removal of form for suspended floor ,roofs, landing, balconies and access platform |
| 7 | Centering and shuttering inclding strutting , propping etc and removal of form for lntles, beams , plinth beams, grders bressumers and cantilever |
| 8 | Centering and shuttering inclding strutting , propping etc and removal of form for column, pillar ,piers ,abutment post and struts |
| 9 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement:2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 10 | Laying R.C.C. 1:1.5:3 Mix (M-20) cement,coarse sand & 20 mm down graded stone grit including cost of all material, labour and T&P etc.complete but excluding cost of centering ,shuttering & Reinforcement. |
| 11 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete .Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 12 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in:Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 13 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 14 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately)Second class teak wood |
| 15 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
| 16 | Providing and fixing factory made solid Foam uPVC profile for kitchen cabinet frame (45 x 20 mm) of approved shade, quality and make. The profile shall be laminated on both sides, made from rigid foam sheets (Single extruded) having density 600 Kg/cum and the exposed edges sealed with PVC edge beading of same shade and colour. The frame shall be fire retardent with necessary screw holding capacity. Frame shall be fixed to wall using Expendable Fastner with necesary stainless steel screws, all complete as per direction of Engineer-in-charge. |
| 17 | Providing and fixing factory made Kitchen Cabinet Shutter/Partition 20 mm nominal thickness of approved shade, quality and make, made from rigid foam sheets (Single extruded) having density 600 Kg/cum and laminated on both side by laminate Sheet/PVC foil lamination. The exposed edges shall be sealed with PVC edge beading of same shade and colour. The shutter shall be fire retardent having necessary screw holding capacity. Shutter shall be fixed to frame using approved hinges with necessary stainless steel screws, all complete as per direction of Engineer-in-charge. |
| 18 | Wall Panelling providing & fixing in position wall panels PF Plain phenol formaldehyde synthetic resin tiles over kail wood frame and provision for providing switch board fixures etc as per drg complete with polishing and fining with french /wax polish as per direction given engg.in charge |
| 19 | Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. |
| 20 | Cement concrete flooring up to 40mm thick without base concrete excluding cost of all materials but including labour, T&P etc. |
| 21 | Providing and laying vitrified floor tiles in different size (thickness to be specified by the manufacturer) with water absorption's less then 0.080% and conforming to IS: 15622 of approved make in all colours and shades laid on 20 mm thick cement morter 1:4 including grouting the joints with white cement and matching pigments etc. including all cost of material, labour & T&P etc. complete. |
| 22 | Glazed Vitrified tiles Matt/Antiskid finish of size of Tile 600 x 600 mm |
| 23 | providing and injecting chemical emulsion for PRE-CONSTRUCTIONAL anti-termite treatment creating a chemical barrier under and around the columns pits wall trench basement excavation top surface of plinth filling junction of wall and floor along the external per meter of building expansion joints surrounding of pipes and conduct etc. Complete (including the cost of chemical emulsion) : |
| 24 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not less than 275 gm/m² |
| 25 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm) |
| 26 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter |
| 27 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 28 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 29 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5' (110 mm bend) |
| 30 | Shoe (Plain)110 mm Shoe |
| 31 | Providing and fixing unplasticised PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement: 4 coarse sand) and making good the wall etc. complete.110 MM |
| 32 | Providing and laying \\"Brick coba\\" 12 mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15 mm to each other over 20 mm thick base of cement mortar 1:4 cement and coase sand mixed with water proofing compoundfilled gaps of coba & tap of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30 cm x 30 cm and side wall paraper shall be mono tythic plaster wall upto 30 cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonary coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight & including s/o all material, labour T&P etc. complete for proper comletion of work including all cost of material, labour & T&P etc. complete. |
| 33 | Laying Cement Plaster in 1:4 cement mortar as directed by Engineer in charge & also including all cost of material, labour & T&P etc. |
| 34 | Three coat of white washing on inside walls and ceiling over one coat of cement primer or base finish |
| 35 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 36 | Finishing of wall with water proof cement paint of approved make and quality on new work with two coats to give an even shade, including supply of all materials,labour and T&P etc.required for proper completion of the work. |
| 37 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 38 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 39 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent. |
| 40 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.Granite stone slab of colour black, Cherry/Ruby red (Area of slab over 0.50 sqm) |
| 41 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 42 | providing and laying of 25 mm thick KOTA stone of sizes 45x45 cm above flooring over previosly prepared base with 2 cm thick 1:3 cement mortar colours and shades |
| 43 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete |
| 44 | Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperture with matching wood beading |
| 45 | Providing and Fixing 25 mm dia brass curtain rods of wall thickness 1.25 mm with two brass brakets fixed with brass screws and wooden plugs etc.wherever necessary complete. |
| 46 | providing and fixing fly proof galvanized MS wire gauge to windows and clreastory windows using galvanised MS Wire gauge with average width of aperture 1.4 mm in both direction with wire of dia 0.63 mm (with second class teak wood beading 62x19mmm) |
| 47 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
| 48 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 49 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :Single half stall urinal with 5 litre P.V.C. automatic flushing cistern |
| 50 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 51 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board (510x1040 mm bowl depth 200 mm) |
| 52 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 53 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. |
| 54 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40 mm dia |
| 55 | Providing and fixing 100 mm sand cast Iron grating for gully trap. |
| 56 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 57 | Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
| 58 | Providing and fixing toilet paper holder :C.P. brass |
| 59 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm. complete, including cost of cutting and making good the walls and floors:100 mm inlet and 75 mm outlet Sand cast iron S&S as per IS - 3989 |
| 60 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 61 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 62 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.15 mm nominal dia Pipes |
| 63 | SAME AS ABOVE ITEM BUT FOR 20 mm nominal dia Pipes |
| 64 | 25 mm nominal dia Pipes |
| 65 | 32 mm nominal dia Pipes |
| 66 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standard and weighing not less than 810gms. 15mm dia, nominal bore . |
| 67 | Providing and Fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore.15 mm nominal bore |
| 68 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore |
| 69 | Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length (15 mm nominal bore) |
| 70 | Providing and Fixing C.P. Brass Angle Valve for Basin Mixer and Geyser points of approved quality conforming to IS:8931,15mm nominal bore. |
| 71 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 72 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 73 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :150 mm diameter |
| 74 | Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m :Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia |
| 75 | Supplying and filling coarse Sand in filter i/c all cost of material labour T&P etc |
| 76 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. |
| 77 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 78 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 79 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. |
| 80 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.150 mm dia |
| 81 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 82 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 83 | Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm,cross - T of size 24x32 mm of length 1200 mm and secondaryintermediate cross-T of size 24x32 mm of length 600mm to formgrid module of size 600 x 600 mm, suspended from ceiling usinggalvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphey wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The workshall be carried out as per specifications, drawing and as per directionsof the Engineer-in-Charge.With 15 mm thick Tegular edged light weight calcium sliciate false ceiling tiles |
| 84 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 85 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design :With 20x20 mm square bar |
| 86 | Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in reinforced cement concrete slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : |
| 87 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A |
| 88 | same as above Group B |
| 89 | same as above Group c |
| 90 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 91 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 2 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 92 | Supply and Fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm dia. |
| 93 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmx75mm) |
| 94 | 4 Module (125mmx75mm) |
| 95 | 6 Module (125mmx75mm) |
| 96 | 8 Module (200mmx75mm) |
| 97 | Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. A.( 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire.) |
| 98 | Wiring for circuit submain wiring alongwith earth wire with the following size of FRLS PVC insullated copper conductor, single core cable in surface recessed medium class PVC conduct as required . 2x2.5 sqmm + 1x2.5 sqmm earth wire. |
| 99 | Same as in item 39 but with 2x6.0 sqmm + 1x6.0 sqmm earth wire. |
| 100 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 101 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 102 | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 103 | Supplying and fixing 5A to 32 A rating , 240/415 V , 10ka , \\"C\\" curve , miniture circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections , testing and commissioning etc. as required. Single pole. |
| 104 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 105 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps |
| 106 | same as above 63 amps |
| 107 | Supplying and fixing of following ways ,single pole and neutral ,sheet steel MCB distribution board 240 V on single/recess complete with tinned copper bus bar neutral bus bar earth bar din bar interconnections powder painted earthing etc as required.(But without MCB/RCCB/Isolator).6 way Double Door. |
| 108 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 6 WAY DOUBLE DOOR |
| 109 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 110 | 15/16 amp switch |
| 111 | 3 pin 5/6 amp socket outlet |
| 112 | 6 pin 15/16 amp socket outlet |
| 113 | Telephone socket outlet |
| 114 | Bell push |
| 115 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25/32 A modular socket outlet and 25/32 A modular SP MCB, “C” curve including connections, painting etc. as required. |
| 116 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 117 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 4 WAY DOUBLE DOOR |
| 118 | Providing and fixing following rating and breaking capacity and pole MCB/MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.200 Amp, 36KA, FPMCCB |
| 119 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 120 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 121 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 122 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing up to two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 123 | Installation ,Testing, Commissioning of pre-wired,flourescent, compact flourescent, LED fittings of all types complete with accessories and tube/lamp etc, directly on ceiling/wall, including connections with 1.5 sqmm FRLS PVC Insulated, copper conductor single core cable and earthing the same etc.as required. |
| 124 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 125 | Installation, testing and commissioning of exhaust fan,in the existing opening, including making good the damage, connections etc as required.A)450 mm |
| 126 | Extra for fixing the Louvers/shutters complete with frame for a exhaust fan of all sizes. |
| 127 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required.A)For 4 way, Double door TPN MCBDB |
| 128 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required.A)For 8 way, Double door TPN MCBDB |
| 129 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required. |
| 130 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 131 | 4 Module |
| 132 | 6 Module |
| 133 | Making of Earthing with G.I.(HOT DIP GALVANISED) EARTH PLATE of size 600mmx600mmx6mm thick i/c accessories and providing masonary enclosure with heavy duty Cover plate having Locking arrangement and watering pipe of 2.7 meters etc. with SALT & CHARCOAL as required. |
| 134 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 135 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 136 | Providing and fixing 25x5MM GI strip on surface or in recess for connections. |
| 137 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 138 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required. |
| 139 | Laying of 1 No. PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of following size direct in ground including excavation,sand cushioning,protective covering and refilling the trench etc. as required.A)Upto 35 sqmm |
| 140 | Laying of 1 No. PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of following size direct in ground including excavation,sand cushioning,protective covering and refilling the trench etc. as required.A)above 35 sqmm and upto 95 sqmm |
| 141 | providing and Laying Approch CC ROAD cement concrete Pavement with vaccum dewatered concrete |
| 142 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 19.32.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 143 | Fabrication of mild steel of iron work grill, gates,Railing etc. including supply of steel bolts, nuts and wastage etc and these fixing required for proper completion of work. |
| 144 | Earth work in cutting or in embankment in ordinary soil,excavation to be in the form of regular pits and earth work in embankment to be in 20 cm.layers,including ramming and dressing the surface to the required levels and slopes and also including 1.50 m lift and 30.00 m lead. The earth from cutting to be used in making embankment or to be deposited as spoil bank within 30.00 m distance as directed by Engineer-In-chargecharge up to a distance of 30M from the foundation trenches:(Building) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysJul 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender