Defence Statutory Bodies & Commissions/Committees Closing in 22 days TDR #56534640

Tender For Special Repairs To Brishabh Bldg In Rashi Area At Navy Nagar Claba Mumbai.

Issued by Statutory Bodies & Commissions/Committees · Mumbai, Maharashtra
Tender Value
5.59 Crore
Estimated cost
Bid Submission
15 Aug 2026
22 days left
EMD
6.04 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repairs To Brishabh Bldg In Rashi Area At Navy Nagar Claba Mumbai.

BOQ

Name of Work:- SPECIAL repairs TO BRISHABH BLDG IN RASHI AREA AT NAVY NAGAR CLABA MUMBAI.
Sl. No. Item Description
1M&L for chipping, and removing carefully loose plaster by low impact hammer, breaker, with out damaging the structure & cleaning and disposal of debris out side the premises etc,including errection of double steel scafolding, covering with green cloth and all the safety measures/precuations and remove the debrius outside MD land (as per the direction of BMC) complete all as specified and dircted.
2M&L for Relieving structural members such as coloumn, beam and slabs of their superimposed loads partially or fully by provision of adjustable steel props, frames etc. including providing necessory timber runners, bracing, jacking up arrangement all complete to the satisfaction of engineer-in-charge(Removing and redoing of brick work, if requied shall be measured and paid seperately)
3M&L for chipping, removing carefully concrete work by low impact hammer, breaker with out damaging the structure & cleaning and disposal of debris out side the premises etc,including errection of double steel scafolding, covering with green cloth and all the safety measures/precuations and remove the debrius outside MD land (as per the direction of BMC) complete all as specified and dircted.( hard concrete should not be removed by hammer)
4M&Lfor Clean existing reinforcement with wire brush/rotary wire brush to make surfce free from rust scales, loose material, dirt etc. complete and providing applying two coats of alkaline rust converting primer confirming to ASTMB-117, on the existing rebars and allowing it to react with rust for 6 hrs and form a corrosion resistant, insoluble and adherant protective layer, including cleaning the reinforcement, wirebrushing to remove loose rust spalls, with time interval of 1 hour between the coats complete all as specified and directed.
5M&L for repairsof steel reinforcement with TMT (CRS) bars(FE 500 D) of appropriate size where 20% of cross section is reduced including dismantling of rusted steel including application of rust convertor FEOVERT and applying protective coating IPNET-RB complete all as specified and directed,
6M&L for Providing and application of hightech concrete penetrating, water based, organic, Bi-polar, calcium nitrate free, migratory corrosion inhibitor on concrete surface having Ph 9.5 which migrates to a virtual extent of 100 mm inside concrete through pores, to inhibit the corrosion process on embedded steel at both anodic and cathodic ends by depassivating the electro-chemical reaction in that region thereby protecting rebar on all sides.
7M&L for for Providing and application full and unbroken coating of anticorrosive protective zinc rich epoxy coating on expose reinforcement in two coats with time interval of minimum 1 hours between each coat including mixing of both componants by weight as per mfg specifications, brush application, curing to form a anticorrosive protective coating with high mechanical strength to cementitious repairs works, etc complete all as specified and approved.
8M&L for Mixing and applying SBR latex modified cementitious bond coat using cement 2.2 kg per square metre on prepared concrete surfaces of parent material complete all as specified and as directed (Note: SBR latex shall be paid for separately). .
9M&L for Mixing and applying SBR latex modified cement mortar 30 mm thick in cement sand mortar in proportions of 1:3 (1 cement and quartz aggregate) with polymer admixed in proportions as approved, including trowelling with wooden tools on prepared concrete surfaces of parent material complete all as specified and as directed(Note: SBR latex will be measured and paid separately as supply only).
10Supply only approved SBR Latex polymer complete ISI marked all as specified and directed.
11M& L for Rebuilding the section of damaged RCC elements to required size avarage thicknes 50 mm by providing and casting with microconcrete of grade M-40 and above including providing and fixing of watertight shuttering of minimun 12 mm thick. with supporting framework,all lead lift, mixing, placing, deshuttering, levelling the surface by grinding off cementitious slurry or construction joint differences if any to satisfaction of Engr -in- charge, . complete. Complete all as specified and directed.
12M& L for Drilling Holes of 12mm dia, upto 100mm deep holes in structural members at the intervals of 300 to 500mm in staggered manner or along the crack as directed by the Engr-in-charge in RC structural element including Cleaning of the holes by air blower and Inserting 12mm dia. Teflon nozzles compatible with epoxy injector and having machined external end to receive outlet of grouting gun. Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing and allow to cure the system for min.8 hrs before grouting including removing nozzle projections, excess putty if any over concrete element grinding, levelling and finishing the external surface, after completion of the work, etc complete all as specified and directed.Note : Epoxy putty cost are included .
13M&L Opening the seperation cracks at the junction of RCC and masonary where ever directed and instructed in to V grooves 2 inch to 3 inch from the eaither sides of the cracks by carefully marking the areas to be opened up using a cutting machine and skillfully/carefully chiselling with a well sharpened chisel and hammeras directed including wire brushing and washing of concrete substrata and masonry wall with water jet to the surface thus repairsed to the entire satisfaction of Engineer -in-Charge complete all as specified and directed.
14M&L Moistering the cracks providing and applying priming/ bonding coat of slurry made out of polyalk EP and cement (or equivalent as specified in the list of brand names) in proportion 1:1 to surfaces prepared as instructed and directed. Filling the cracks/ grooves by providing and applying Polyalk EP polymer modified cement mortar (or equivalant as specified in the list of brand names) in propotion of 1:5:15 (Polyalk EP : cement: graded sand /quarts sand) on the prepared surface and finishing it in level with the exsisting plaster including hand packing curing and making in the surface similar to the external plastering using wooden floats /punch etc complete as per specified and directed.
15M&L Drilling holes of required size up to 16 mm diameter and up to 50 mm depth in concrete and cleaning the same as directed
16M&L Providing and fixing 12 mm diameter aluminium/PVC injection nipples and securing the same as directed.& providing and injucting cementitious grout using CEBEX- 112 additive of Fosroc at the rate of 225 grams per bag of cement and using suitable mechanical gun / pump including mixing etc. complete all as specified.
17M& L for Providing and applying dubbing coat with forced application (guniting) method avg 20-30mm thick plaster with readymix prepacked proportioned dry mix mortar, blended with PP fibers, mixed with including liquid water proofing compound on other than fair faces of brick wall or concrete surfaces additivres on external surfaces including transporting of material, mixing, curing, etc.completeall as specified and directed.
18M&L for Providing and applying fair finish 10mm thick plaster with ready mix prepacked proportioned dry mix mortar on external surface using factory manufactured pre mix / ready mix mortar as in setting coat addition and including WPC @ 200ml per bag of mortar on Brick or concrete surfaces with recrene finish complete all as specified and directed. . Note:- for Item No 1.0 to 18.0 (a) Work shall be carried out by authorised applicator only.(b )Every step shall be written and approved by GEthrough stage passing register which shall be kept on record.
19M&L for preperation of new plasted surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed. Note : (a) The work shall be arried out by authorised applicator only . (b) The contractor shall provide 5 year warranty from the appicator and documents shall be kept on record before payments of RAR.(c ) Each stage shall be approved by GEon stage passing register and shall be kept on record.
20M& L for Removing and demolishing the existing water proofing treatment of any type cleaning with wire brush to remove all dirt, dust and washing with water including debris out side MD land complete all as specified and directed
21M&l for cement concrete Type B1 1:2:4 20 mm graded stone aggregate 40 mm thick in floor finishing the surfaces even and smooth with out using extra cement complete all as specified and directed
22Supply only Liquid water proofing compound.(ISI Marked) complete all as specified and directed
23M&L for water proofing treatment to RCC roof slab all as specified below and as directed:- ( a) Apply one coat of bitumous primer @ 0.25 Kg/Sqm. (b) Apply a coat of blown type bitumen grade 85/25 heated to working temperature of 180 degree centigrade and applied at 1.20 Kg/Sqm of the surface area. (c) Laying APP polymer modified membrane 4mm thick with non woven polyster reinforcement weighing not less than 4.00 Kg/ Sqm applied by torch application method and inserting membrane on vertical surfaces upto 300 mm height in continuation with floor waterproofing. (d) Apply a coat of blown type bitumen grade 85/25 heated to working temperature of 180 degree centigrade and applied at 1.20 Kg/sqm of the surface area. (e ) Over lapping of Membrane shallbe min 10 cm at transverse direction and 15 cm at on longitudinal direction. (f) Apply a coat of solar reflective bituminous aluminium paint @ 0.10 Kg/Sqm. (g ) Work shall be carrried out by authorised applicator only .
24M&L for Cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as coping ,roof padding, in roof kerb or mud stops , bed block water through and like including weathering,silghtly rounded or chamfered angle and throating with necessary formwork all as specified and directed.
25M&L for Cement concrete tiles 30cm X30 Cm x (20-22) mm thick machine pressed set jointed in neat cement slurry in floors and cut and polished over 20 mm cement screed (1:4 ), complete all as specified and directed.
26Taking down cement plaster, any description on brick or stone walls, etc including racking out joints hacking for key scrubbing down with water etc and removing the debris out of MoD land complete all as specified and directed.
27M&L for preparation of old plastered surface of ceiling and applying 2 coats of oil emuslion distemper all as specified and directed.
28M& L for rendering 15 mm thick plaster in C M 1:4 with readymix prepacked proportioned dry mix mortar on fair faces of brick wall or concrete surfaces finishing the surface even and smooth with out using extra cement complete all as specified and directed.
29M&L for preparing newly plastered surface of wall and applying two coats of Premium Quality Interior Acrylic Emulsion Paint over a coat of alakali resistant primer, over 1mm thick wall care putty complete all as specified and directed
30M&L for complete removal of existing surface of wall by scraping washing and applying two coats of Premium Quality Interior Acrylic Emulsion Paint over a coat of alakali resistant primer, over 2mm thick wall care putty complete all as specified and directed
31M& L Writing letter or figures by synthetic enamal paint as per the dirction of Engineer-in-Charge, n exc 30 cm high (Block,Roman, Italic or Indian) per cm height of letters complete all as specified and directed
32Dismantling structural steel work of any description and in any position all as specified and directed.
33M&L for framed work as MS grills with ends of bars shouldered and or riveted or forged into spikes, framed guard bars barred iron doors, ladders framed balusters, walk ways, railings, framework of water tanks and similar work conform to Fe 290 Gde-E-165 & fixed in position complete all as specified and directed
34M&L for plain,black mild steel sheeting in gates, 1.25mm thick sheet welded or shouldered to angle iron frame and all as specified and directed.
35M&L for Welding in repairs n.exc 2.5 cm in length thickness of metal to be welded Exc. 6mm but n.exc 9 mm complete all as specified and directed.
36M&L for Preparation of new or previously untreated surfaces of steel or steel based materials of any description not other wise described, over 10cm width or girth and applying two coats of synthetic enamalpaint over a coat of red oxide primer zinck chrome complete all as specified and directed.
37M&L for Preparation of old painted surfaces of steel or steel based materials of any description not other wise described, over 10cm width or girth and applying one coats of synthetic enamalpaint complete all as specified and directed.
38M&L in repairs anodised aluminium sheeting 22 gauge thick fixed as in crumple section incl necessary scaffolding complete all as specified and directed .
39Demolition of lime concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed .
40M&L for cement concrete 1:7:12 type F2, (40 mm graded stone agg) as in foundation filling and sunken floors etc all as specified and directed.
41M&L for water proofing treatment of sunken slabs by cleaning RCC slab surface floors and walls by wire brush and rendering 6 mm thick in CM 1:4 mixed with integral WPC on uneven surface to make it even. Fill it water and check for dampness and seepage, all junctions points of side walls where CI/GI pipe are passing shall be sealed with epoxy mortar. Apply two coats of polymer modified cementious water proofing coating of minimum thickness of 1 mm each layer as per manufacturers instructions on floor & walls (upto 100 mm above FFL) and spray coarse sand on surface when the second layer is still sticky. Apply 20 mm thick plaster in CM 1:4 mixed with integral WPC of approved make on floors and walls including rounding of corners and junctions stoping towareds spouts. All pipes laid in sunken portions shall be covered with 50 mm thick PCC 1:3:6 all around after painting with anti corrosive black japan paint on GI/CI pipes. Test the water proofed area by filling water at least 72 hours and tested for leakage/seepage for the entire satisfaction of GE. After above said treatment apply two coats of hot blown bitumen @ 1.5 Kg /Sqm for each coat and laying APP based polymeric membrane minimum weighing 3Kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150gms/Sqm) land on primed surfaces by forced application APP based polymeric membrance and providing 40 mm cpvc pipe of 30 cm length for spoting in floors , tile work shall be carried out 2 to 3mm spacer filling with epoxy grouting complete all as specified and directed. (Note : If leakage/Seepage occured after filling water at least 72 hours, the above said treatment will be re-done completely)
42M&L in repairs 100 mm dia PVC floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4), complete all as specified.
43M & Lfor post anti-termite treatment using chloropyrifos 20EC along the external wall below concrete apron by drilling 12 mm diameter holes as close as possible to the plinth wall at 300 mm apart, deep enough to reach the soil below and the chemical emulsion pumped into these holes to soak the soil below at a rate of 2.25 Iitres per linear metre. & plugging holes etc. in apron all specification and procedure as per IS 6313 (Part 3) :2001 complete all as specified and directed.
44M & L for post anti-termite treatment of soil under existing floors by drilling 12 mm diameter holes and filling with emulsion at the rate 1 liter per hole, 300mm apart including drilling & plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors. etc. Complete all as specified and directed
45M & L anti-termite treatment at the point of contact of wood work by chemical emulsion (in oil or kerosene based solution) at the rate 0.5 litres/holes by drilling 6mm dia holes at a downward angle of 45 degree at 150 mm center and sealing the same etc. Complete all as specified and directed .
46M&L for bottle trap 32 mm fancy type cast copper alloy chromium for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap complete all as specified and directed.
47Dismantling floor hearth or wall tiling including cement mortar bedding removing serviceble tiles to store and rubbish off the permises.complete all as specified & as directed.
48M & L Non - skid Ceramic tiles coloured of approved make 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM (1:6), complete all as specified.
49M&L for Coloured glazed ceramic tiles, size 300x600 x 7-8 mm thick on vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match of the shade over and including backing layer of 10mm thick in CM 1:4 complete all as specified and directed.
50Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) and removing the debris out of MoD land complete all as specified and directed.
51Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and directed .
52M&L for Brushing neat cement slurry with 3.0kg of cement per sq. metre complete all as specified and directed
53M&L for double charged Vitrified Tiles 600 X 600 X 9to 10mm Thick , in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed of 20mm thick in CM 1:6 for laying floor finishes complete all as specified and directed .
54Ditto all as per item No 53 above but as in skirting over & incl backing layer of 10mm thick in CM 1:4 complete all as specified and directed
55M&L, for machine cut mirror polished kota stone slab flooring 22-25mm thick over cement screed bed in CM (1:4) 15mm thick, & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete all as specified and directed.
56M&L, for machine cut mirror polished kota stone slab flooring 22-25mm thick in riser / treads of steps in single piece, skirting, dado and pillar laid over cement screed and jointed withover cement screed bed in CM (1:4) 15mm thick, & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing and rounding the edges where as required complete all as specified and directed.
57Dismantling of Stone slabs and tiles laid bedded and pointing in any mortar of any description or thickness in floors, aprons skirting/dado etc complete all as specified and directed .
58M&L for polishing of old / existing kota stone flooring as per SSR Part I complete all as specified and directed .
59M&L machine cut cudappah stone 22-25 mm thick over base, laid and jonted with grey cement slurry mixed with pigment to match the shade of the stone including rubbing, polishing complete all as specified and directed .
60M&L for 18-20 mm thick machine cut mirror polished Granite (of any type) work as in steps, jambs, pillars, cooking platforms, working table and like over 15 mm thick screed bed or bedding layer in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed
61S&F single piece length of mirror polished machine cut kota stone as in jambs/cills of windows 18-20 mm thick laid and jointed with grey cement paste mixed with pigment to match the shade of the slab over 15 mm thick in CM 1:4 including rubbing and mirror polishing and necessary bull nosing complete all as specified and directed.
62M&L for extra two Nos grooves 2x2 mm over stair case treads complete all as specified and directed .
63M&L for Cutting chases, pinning in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of shelves etc, and making good, cutting n exc 10 cm girth in brick walls complete all as specified and directed .
64S&F in repairs sink with drain board, made of stainless steel 1mm thick of Grade SS 304 kitchen or laboratry with plugs, washers and wastes coupling fitting, including beading in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed .
65S&F in repairs wash hand basin vitreous china coloured (flat back) of size 550x400mm including CI bracket dia 32mm dia waste coupling and 32mm dia PVC flexible waste pipe 90cm long etc. complete all as specified,
66S&F in repairs fancy type CP Pillar taps 15 mm dia, cast copper alloy, with capstan heads, screwed down high pressure, suitable for counter top/ bracket fix wash basin and with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified.
67S&F 32mm dia LDPE PVC waste pipe of pressure rating 6 kgf/cm2 fixed complete to for WHB and kitchen sink includding socket & screw complete all as specified and directed.
68S&F 40mm dia high density polyethylene pipes (HDPE) of pressure rating 6 kgf/sqcm of fixed to wall, floors for drain out the waste water from Kitchen Sink, WHB etc complete all as specified and directed by Engr-in-Charge.
69M&L in repairs vitreous china wash down water closet padestal pattern white (excluding fixing bolts, flushing cistren and flush pipe) with 'P' or 'S' trap and making all connection complete all as specified and directed .
70Supply only Plastic water closet seat cover, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminisied hinges devices complete all as specified and directed by Engr-in-Charge.
71S&F in repairs PVC valveless, syphonic action type, flushing cistern, low level, white 10 litre capacity with inlet, ball valve, float and handle including brackets and polyethylene flush pipe complete all as specified and directed .
72S & F health faucet with jet spray, 1.5 metre long, cast copper alloy, nickel chromium plated finish, 15 mm bore, 100 mm long with 1 m long PVC tube with wall hook chromium plated fitted to stopcock complete all as specified and as directed.
73S&F brass chromium plated 20mm dia, D type, 60cm long tubular towel rail complete all as specified and directed .
74S&F brass chromium plated towel ring complete all as specified and directed
75S&F in repairs PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed.
76S&F repairs 600mm x 450mm bevelled edge mirror 6 mm thick of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with CP Brass screws and cup washerscomplete all as specified and directed.
77Demolition of reinforced cement concrete of any description and in any position ( reinforcement cut as required to facilitate demolition whenever required), complete all as specified and as directed.
78Demolition of brick work or stone masonary built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles.
79Material and labour for brick work with sub class \\"B\\" bricks, straight or curved on plan exc 6 m mean radius, built in CM (1:6), complete all as specified.
80M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4), complete all as specified.
81Material and labour for PCC 1:2:4 type B-1 (using 12.5mm graded stone aggregate) as in roof kerbs and leveling course on RCC roof surfaces all as specified and directed.
82S&F for in repairs 20mm dia stainless steel curtain rod thickness not less than 1.0mm are made of SS-304 with a perfect glossy mirror finish as approved complete all as specified and directed .
83S&F for in repairs stainless steel fancy types domes cum brackets suitable for 20 mm dia curtain rod as approved and fixed to both ends with the curtain rod etc complete all as specified and directed.
84Taking down chowkats or frames exc 1.5 sqm and n.exc 4 sqm each with shutters complete all as specified and directed.
85Taking down chowkats or frames with shutters (without taking off shutters from the frame) not exc 1.5 sqm each all as specified and directed.
86Taking down shutters of any description n exc 1.0 sqm each complete all as specified and directed.
87Taking down shutters of any description exc 1 sqm and n exc 2 sqm each complete all as specified and directed.
88S&F 2nd class hard wood (sal) plain, solid, straight chawkhats and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints all as specified.
89M & L preparing surfaces of wood and wood based materials, and treating back of chowkats with tar or coal tar black paint complete all as specified and directed .
90M & L preparing surfaces of steel and iron work, and treating small articles such as holdfast with tar or coal tar black paint complete all as specified and directed.
91S&F mild steel hold fasts, wall ties and similar small articles conforming to Fe 290 Gde E-165 complete all as specified and directed .
92M&L Providing PCC 1:2:4, type B1(20mm graded aggregate) for hold fasts including neessory form work complete all as specified and directed .
93M & L cutting holes in brick /stone walls in cement mortar exc half & n.exc. One brick depth of embedded portion of hold fast and making good in cement concrete 1:2:4 type B1 or in cement mortar 1:3 and finished surfaces feven and smooth complete all as specified and directed.
94Supply & Fixing upto any floor height powder coated (50 micron minimum thickness) Aluminium anodised frame and shutter for door, windows, ventilators etc. with one or more rebates including joining cleat for fixing etc. fixed type/louvered window or ventilator without sash bar, aluminium including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, sliding rollers, rubber gasket etc. complete all as specified and directed by the Engineer-in-charge.a) Glazing shall be measured separately b) Item shall be paid as per weight of aluminium section c) The rate quoted shall be inclusive of neoprene beading, glazing clips, screws, etc., as required which shall not be measured for arriving the weight d) The rate shall be inclusive of the locking arrangement including complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing surface area Note:- Aluminium window shall be factory made, contractor shall make arrangement for visiting the factory site during the currency of work (if required). The size of aluminium section shall be as per HQ CE(N) MZ TD Drawing No. TD/2021/01 to 05.
95S&F in repairs aluminium grill with and including suitable aluminium anodised frame F/H section Deco grill pattern DG-102 (aparture 80 X 66 mm) and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, as directed
96S&F aluminium alloy wire mesh 0.45 mm nominal dia of wire and average width of aperture 1.4 mm fixed with aluminium wire staples to alumn shutters complete all as specified and directed
97S&F 5mm Thick Float Glass Pin Headed type and glazing with aluminium and neoprene beads in square not exc 0.5 sqm in each pane complete all as specified and directed
98S&F 5mm Thick Float Glass and glazing with aluminium and neoprene beads in square n. exc 0.5 sqm in each pane complete all as specified and directed .
99Supply and fixing 35mm thick factory made moulded PVC door shutter with 2, 4 or 6 raised panel design consisting of solid core single leaf flush shutter of 30mm thickness, lipped with 15mm (5mmx3) thick on one stiles and top rails & 10mm (5mm x 2) thick on other rail stiles and bottom rails, front face laminated with 2mm thick prelam or walnut colour PVC sheet in moulded design with 2, 4 or 6 raised panel and 2mm thick prelam or walnut colour PVC sheet on other side. PVC sheet having density 600kg/Cbm and should be termite proof, water proof & fire proof and fixing with the frame at site as per manufacturer specification and complete all as specified and directed .
100Supply and fixing PVC door frame of size 100mm x 45mm with a wall thickness of 5mm, made out of extruded 5mm prelam PVC sheet of density 600kg/Cbm, meter cut at two corners and jointed with 4 Nos of 150mm long brackets of 15x15mm MS square tube. The two vertical door frame to be reinforced with 40x20mm MS tube of 19 gauge through out the frame and fixing in opening as per manufacturer instruction and complete all as specified and directed.
101S&F 35mm thick second class hard wood factory made plain framed panelled shutters (two panes) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board medium density with commercial veneering both face. The size of rail shall be as per IS 1003 (Part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
102S&F 35 mm thick flush shutters, solid core construction, with block board core and ply wood face panels, commercial type on both side all as specified and directed.
103S&F 25 mm thick flush shutters, solid core construction, with block board core and ply wood face panels, commercial type on both side all as specified and directed.
104S&F 30mm thick 2nd class hardwood glazed and skeleton shutters open rebated and prepared to receive glass, gauze, etc. divided in to squares,with plain, chamfered or rounded , mitred and rebated sash bars,any numbers ; edges of framing plain, chamfered or rounded , fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part I, Section 8 clause 8.24 (b) ; supplied and fitted to chowkhats of Second class hard wood. All as specified and directed.
105S&F in repairs 18/19mm thick prelaminated particle board, exterior grade, prelaminated both sides with decorative choice laminations, fixed with screws to timber frame work incl 18/19mm wide and 6mm thick external teak wood lipping fixed with nails and glue to board as in cup board shutter, CB shelves and kitchen cabinate etc like similar work complete all as specified and directed .
106S&F in repairs aluminium wire cloth, 0.45 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, wooden beedings to doors complete all as specified and directed
107S&F 100mm size stainless steel butt hinges (ISI Marked) complete all as specified and directed
108S&F in repairs100mm size stainless steel butt hinges (ISI Marked) complete all as specified and directed
109S&F Stainless steel ‘D’ Type handle 150 mm size, fabricated type, complete all as specified and directed
110S&F in repairs Stainless steel ‘D’ Type handle 150 mm size, fabricated type, complete all as specified and directed
111S&F Aluminium, anodised, barrel tower bolts 150mm size of extruded section ISI Marked complete all as specified and directed
112S&F in repairs Aluminium, anodised, barrel tower bolts 150mm size of extruded section ISI Marked complete all as specified and directed
113S&F Aluminium alloy, anodised, sliding door bolt 300mm size ISI marked with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast alumimnium alloy complete all as specified and directed.
114S&F in repairs Aluminium alloy, anodised, sliding door bolt 300mm size ISI marked with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast alumimnium alloy complete all as specified and directed.
115S&F Floor door stopper of Aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate 140 mm complete all as specified and directed
116S&F in repairs Floor door stopper of Aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate 140 mm complete all as specified and directed
117S&F magic eye fancy type of brass for door including drilling cutting of holes and making good complete all as specified and directed.
118S&F magnetic door catcher including letting in and fixed complete all as specified and directed .
119S&F 125mm size hasp and staple safety type, aluminium anodised including bolt to hinge plate and fixed with screws complete all as specified and directed .
120M&L for Preparation of new or previously untreated surfaces of wood or wood based materials of any description not other wise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
121M&L for preparation of old painted surfaces of wood or wood based materials of any description not other wise described, over 10cm width or girth and applying two coat of synthetic enamel paint, complete all as specified and directed .
122S&F of 18 mm thick Rajshri Celuka ply or Techno commercial equivalent of Plain color fixed with screws, solvent cement/ adhesive to make kitchen cabinet sides top and bottom and shelves inside the cabinets complete as per specifications and as directed
123S&F of 18 mm thick Rajshri Celuka ply or Techno commercial equivalent of one side Prelam/Rigidlam and other side plain white colour to make kitchen cabinet Shutter/ drawer Front shutters in double panel complete as per specifications and as directed
124S&F of stainless steel handles 100 mm size complete as per specifications and as directed .
125S&F 40mm bore GI pipe medium grade (ISI marked) with all fitting fixed in to walls and ceilings or laid in floors as sleeve/spout incl necessary making hole in wall/floor complete all as specified and directed
126Taking down CI soil/waste/vent/rain water pipes including all fittings like shoes bends swan necks etc of any dia complete all as specified and directed ,
127Supply and fix 110 mm dia PVC (SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls / laid in trenches as mentioned and shown in HQ CE (N) Mumbai zone TD Drg No TD/2023/01 toTD/2023/03 complete all as specified and directed.
128S&F 110 mm PVC (SWR) pipes single socketed as in soil/waste/vent pipes with earsin any length with rubber ring joints, laid in trenches or in floors soil/waste/vent pipe in any length with ears 110 mm bore in any length laid in trenches or in floors complete all as specified and directed .
129S&F 110mm bore PVC (SWR) bends (any radius) complete all as specified and directed.
130S&F 110mm bore PVC (SWR) branch piece single (single Y/T) equal or unequal complete all as specified and directed .
131Supply and fix 75 mm dia PVC (SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls / laid in trenches with and including and including fixing of pipes in wall with clamps as mentioned and shown in HQ CE (N) Mumbai zone TD Drg No TD/2023/01 toTD/2023/03 complete all as specified and directed.
132S&F 75 mm PVC (SWR) pipes single socketed as in soil/waste/vent pipes with earsin any length with rubber ring joints, laid in trenches or in floors soil/waste/vent pipe in any length with ears 75 mm bore in any length laid in trenches or in floors complete all as specified and directed .
133S&F PVC (SWR) bends (any radius) with oval access door for soil/waste pipes 75mm bore diminishing pieces or tapers on walls complete all as specified and directed
134S&F PVC (SWR) 75 mm bore junction single ''T' or 'Y' (equal or unequal) complete all as specified and directed
135S&F in repairs for PVC (SWR) gully trap 125/110mm, setting & jointing with solvent cement gully traps, square or round mouthed 150x100mm fixed including jointing to pipe complete all as specified and directed
136S&F 75mm PVC (SWR) vent cowls joints with pipe complete all as specified and directed .
137S&F 110mm PVC (SWR) vent cowls joints with pipe complete all as specified and directed.
138S&F 75mm PVC (SWR) sanitary connection socket of suitable length to connect with Trap to out-let of pipe line complete all as specified and directed .
139Taking down PVC rain water pipes including all fittings like shoes bends swan necks etc of any dia complete all as specified and directed.
140Supply and fix 160 mm dia PVC (SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls / laid in trenches with and including and including fixing of pipes in wall with clamps as mentioned and shown in HQ CE (N) Mumbai zone TD Drg No TD/2023/01 toTD/2023/03 complete all as specified and directed.
141S&F PVC (SWR) bends (any radius) for rain water pipes 160 mm bore diminishing pieces or tapers on walls complete all as specified and directed .
142S&F PVC covers to MS railings of stair case hand rail complete all as specified and directed
143S&F for stainless steel cloth hanger peg set of 6 of premium quality fixed with CP brass screws complete all as specified and directed.
144Supply and fixing of 04 pieces pulley operated Cloths Drying system casting of Aluminium pipe of outer dia 22 mm inner dia 19.8 mm and channel pair of length 2.50 mtr with pulley made up of Devil mounted and fixed with self tapping screw. Rope will be HDPE double core of 4 mm with rope Guide at locking system to hide rope. Channel to be dia of minimum weight of pipe shall not be less than 0.20 kg/Rm and maximum weight of pipe in one unit not less than 2 kg. Weight of rope shall be not less than the 550 gms / mtrs.
145S&F for in repairs stainless steel kitchen plate rack made out of 0.63mm thick sheet of SS 304 Grade size 30\\" x 36\\" x 9\\" of approved pattern & make and wt not less than 8.0 Kg each fixed to wall with CP brass screws complete all as specified and directed
146S&F for number plate made out of 3mm thick acrylic sheet of and size 100mm x 180mm including written 3 numeric letter height not less than 65mm (colour, design & pattern as approved by EIC) fixed with CP brass screws complete all as specified and directed.
147S&F prefabricated cast iron work grade FG 150, unmachined in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors. dampers, stop valve boxes, baluusters and similar works (weight of each articles exceeding 5 kg) complete all as specified and directed.
148M&L for Excavation in over areas in soft/loose soil and getting out complete all as specified and directed
149Returning filling in, including spreading, leveling watering & well rammng in layers not exc 25cm thick complete all as specified and directed by Engineer -In- Charge
150Removing excavated material to a distance not exc 50 mtr & depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified & diected
151M&L Hard core of gauge n.exc 63 mm deposited spread and levelled in layers n.exe 15 cm thick watered and rammed to a turre surface complete all as specified and directed.
152M&L for 100 mm thic PCC 1:3:6 type C2 ( using 40mm graded crushed stone aggregates) as in sub base to floors, pavements etc complete all as specified and directed
153M&L for Machine pressed precast concrete interlocking paver block having glossy finish shape and size as approved by GE confirming to IS 15658-2006 of 60 mm thickness, M-40 Grade of with grey cement and pigments laid over and including 50 mm thick dry sand cushioning and voids filled with dry sand , including compaction by means of surface vibrator including removing old paver blocks complete all as specified and directed.
154Taking down of existing FRP chajja 60cm to 120cm wide and refixing after repairs work with and incl through fastner of adequate size as approved by GE complete all as specified and directed
155M & L for providing & fixing of factory made Fibre glass Reinforced Plastic (FRP) \\"chajja\\"- 4mm thick of \\"fibreways\\" brand in required colour, size and design made by Resin Transfer Moulding (RTM) Machine Technology available with laminated single piece, having smooth gradual slope curvature for easy drainage of water and duly reinforced by 2 Nos vertically and 1 No horizontally 50x2mm thick MS Flat with 12mm in built hole for grouting on the existing wall along with the 50mm flanges duly inserted and sealed in the wall complete in one single piece casted monothically including all necessary fittings. Molded with unsaturated Polyster resin as per IS: 6746 duly reinforced with fibreglass chopped strand mat (CSM) as per IS: 11551. Available with protective gel coat U/V coating on top for complete resistance from the extreme of temperature, weather & sunlight fixed with and incl through fastner of adequate size complete all as specified and directed.
156M& L for Structural auditing after repairs work with photo graphy to assess the structural position, Non destructive test with Ultrasonic pulse Velocity test, Rebound Hammer test, cover meter test for RCC structure, chemical test, Half cell Potential and Carbonation Test , Core cutting & Compression test, Slab deflection Test, Verticality Check, stability checks , to check and confirm present status of structure on basis of NDT Results. The report alongwith photographs duly vetted by IIT/ government Engineering College and submitted to GE for records. Note : Minimum No of test required to be carried out in bldg :- (a) Ultrasonic pulse velocity test : 60 Nos, (b) Rebound Hammer test : 60 Nos, (c) Core test : 15 Nos(d) Reinforecemt mapping : 15 Nos, (e) Chemical Test : 15 Nos, (f) Half cell potential test : 30 Nos(g) Carbonation test : 30 Nos, (h) Cover meter : 15 Nos (i) Slab load test : 4 Nos 2. All above test should be carried out as per relevant IS Code. The configration of building is G+14 story. The No of test mentioned above for each building is minimum, it may vary according to vintage and condition of bldg.Note : All test is to be carried out by auth firm /agency according to relevant IS and work has to be carried out up to G+14 floors )
157Removing demolished material exc 5 Km but n.exc 15 Km and depositing where directed complete all as specified and directed
158Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition sepertately) and making good disturbed surfaces of walls, floors etc. Note: Serviceable tube lights etc shall be kept under safe custody and refixed as directed.
159M & L for concealled point wiring complete with 1.5 sq mm single core multistranded FRLS PVC insulated unsheated copper conductor,1100 volts grade conforming to IS-694:2010 drawn through and including Heavy duty non-metallic PVC conduit not less than 25 mm dia with accessories such as Bends, Tees, Elbows,coupler etc terminated in metalic box concealled in wall including one FRLS PVC insulated and unsheathed multistranded green colour copper conductor 1.5 sqmm as earth continuity conductor connected to common earth dolly for One light/Exhaust/Ceiling fan point controlled by one switch SP one way.Note : - (i) Circuit conductor from MCB DB to Switch boards should not be less than 2.5sqmm for(a) swich boards having light/fan points and 6A socket in common circuit.(ii) Modular metal flush box shall be paid seperately under relevant items of this schedule.(iii) Colour coding shall be followed as Phase- Red, Neutral -Black, Earth - Green
160One light point controlled by two two-way switch.
161One 3 pin socket combination 6 Amps on same board.
162One 3 pin socket combination 6 Amps on independent board.
163One bell point controlled by one push button 6 amps on independent board.
164All as per item No. 160.0 here in before point with 2.5 sqmm single core multi stranded FRLS PVC insulated unsheated copper conductor 1100 volts grade confirming to IS-694:2010 for one 3 pin switch socket combination 15 Amps on independent board
165S & F modular switch, 6 Amps , One way, one module , ISI marked complete all as specified and directed.
166S & F modular bell push 6 amps 1 module, ISI marked complete all as specified and directed.
167S & F modular switch, 16 Amps , One way, one module , ISI marked complete all as specified and directed.
168S & F bell electric AC 230 Volts single pole ding dong with ISI marked complete all as specified and directed.
169S & F modular socket, 6 Amps , 2/3 pin combined , two module , ISI marked complete all as specified and directed.
170S & F modular socket, 16 Amps , 6 pin combined , two module , ISI marked complete all as specified and directed.
171S & F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps Ccurve complete all as specified and directed.
172S & F modular switch, 6 Amps ,two way, one module , ISI marked complete all as specified and directed.
173S&F modular TV Socket including flush box and cover plate with frame
174S & F ceiling rose surface bakelite with ISI mark , flush type three terminals complete all as specified and directed.
175Supply & Fixing Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
176Supply & Fixing Retrofit LED lamp 12 Watts ( Min 120 luminous/Watt) complete all as specified and directed ..
177S & F modular stepped type fan regulators 2 module, 120 W, 230 volts ISI marked complete all as specified and directed.
178S & F modular metal flush box of following modules flushed in wall and making good surface complete all as specified and directed. For 2- Module
1793- Module
1804- Module
1816- Module
1828- Module
183S & F modular white cover plate with frame for one modules complete all as specified and directed. 1- Module
1842- Module
1853- Module
1864- Module
1876- Module
1888- Module
189Supply and fixing integrated LED batten 20 Watt, 4 feet long,( Min 120 luminous/Watt) full white in Engineering plastic battern with white acrylic cover with built in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5 sqmm from ceiling rose to connector of fitting alongwith provision of two Nos of PVC box of size 75x75x20mm for mounting light fittings complete all as specified and directed.
190Refixing of old serviceable LED tube light upto 20 watt including sensor based including 2 core twisted copper wire of 0.5 Sqmm and 2 numbers PVC base of 75 mm X75 mm X20 mm complete and as directed. Note: Tube light taken down vide item No .189.0 shall be reused.
191Supply and fixing integrated LED batten 10 Watt, ( Min 120 luminous/Watt) 2 feet long, full white in Engineering plastic battern with white acrylic cover with built in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5 sqmm from ceiling rose to connector of fitting alongwith provision of two Nos of PVC box of size 75x75x20mm for mounting light fittings complete all as specified and directed.
192S&F 10W LED battern with inbuilt smart motion sensor, 230 Volt , 50 Hz , 2 feet, polycarbonate extruded channel, with diffuser for glare free light, Inbuilt motion sensor prewired with 25% dimmer illuminous in ideal time with all accessories including connecting up with twisted twin core flexible copper wire of 0.5 sqmm from ceiling rose to connector of fitting alongwith provision of two Nos of PVC box of size 75x75x20mm for mounting light fittings complete all as specified and directed. Please Enable Macros to View BoQ information
193S&F 10W LED battern with inbuilt smart motion sensor, 230 Volt , 50 Hz , 2 feet, polycarbonate extruded channel, with diffuser for glare free light, Inbuilt motion sensor prewired with 25% dimmer illuminous in ideal time with all accessories including connecting up with twisted twin core flexible copper wire of 0.5 sqmm from ceiling rose to connector of fitting alongwith provision of two Nos of PVC box of size 75x75x20mm for mounting light fittings complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56534640
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 5.59 Crore
LAST DATE 15-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repairs To Brishabh Bldg In Rashi Area At Navy Nagar Claba Mumbai.
Basic Detail
Tender No 8292/CWE(NW)MUMBAI/2026/E8
Bidding Type Tender
Location
City Mumbai
State Maharashtra
Key Dates
Publish Date 18 Jul 2026
Submission Date 15 Aug 2026
Open Date 17 Aug 2026
Finance
Tender Value 5.59 Crore
Tender Fee 3000
EMD 6.04 Lakhs
Exemption Available
Document List
8292.rar
BOQ_872632.xls
da67aa9e-4244-4780-9299-11df2f9d8322.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 22 days
Aug 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 24 days

Tender Documents

Download All (ZIP) ↓
rar

8292.rar

xls

BOQ_872632.xls

html

da67aa9e-4244-4780-9299-11df2f9d8322.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders