Tender For Water Supply Schem Under Major Head / S.H.: Shifting Of Existing 10,000 Gph Capacity Package Type Irp From Joychandpur Old Dtw To New Dtw At Joychandpur Near Trishna Wildlife Sanctury Under Joychandpur Gp Under Rajnagar Rd Block Under Barp
Tender Overview
Project Description
Tender for Water Supply Schem Under Major Head / S.H.: Shifting Of Existing 10,000 Gph Capacity Package Type Irp From Joychandpur Old Dtw To New Dtw At Joychandpur Near Trishna Wildlife Sanctury Under Joychandpur Gp Under Rajnagar Rd Block Under Barpathari Dws Sub-Division During The Year 2026-27.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.all kinds of soil |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.-All kinds of soil |
| 3 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering -All work upto plinth level: |
| 5 | 1:3:6 ( 1 Cement: 3 fine sand : 6 graded well burnt brick aggregate 20 mm nominal size) |
| 6 | 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size) |
| 7 | First class brick work in foundation and plinth including cost of all materials as required complete:-i) In Cement mortar 1:4 ( 1 cement : 4 fine sand ) |
| 8 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto floor five level.Thermo-Mechanically Treated bars of grade Fe 500D or more. |
| 9 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement--All work upto plinth level:a)1 : 2 : 4 ( 1 cement : 2 fine sand : 4 graded well burnt brick aggregate of 20 mm nominal size) |
| 10 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement-a) 1 : 2 : 4 ( 1 cement : 2 fine sand : 4 graded well burnt brick aggregate of 20 mm nominal size) |
| 11 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-i) 1 : 2 : 4 ( 1 cement : 2 fine sand : 4 graded well burnt brick aggregate of 20 mm nominal size) |
| 12 | Centering shuttering including struttings, propping etc. and removal of form work for: |
| 13 | Foundations, footings, bases for columns etc. for mass concrete with timber plank |
| 14 | Columns, Pillars, Piers, Abutments, Posts and Struts with wooden plank |
| 15 | Lintels beams plinth beams girder bressumers and cantilevers with wooden plank |
| 16 | First class brick work in superstructure above plinth level & upto floor-five level including cost of all materials as required complete:- In cement mortar 1:4 ( 1 cement : 4 fine sand ) |
| 17 | Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:-i) In Cement mortar 1:4 ( 1 cement : 4 fine sand ) |
| 18 | Providing and fixing MS round holding down bolts with nuts and washer plates complete as per standard design |
| 19 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.with mild steel tubes Hot finished welded (HFW) type medium class. |
| 20 | Providing and fixing in position 1mm thick M.S. sheet sliding-shutters with frame and diagonal braces of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junction and corners 25mm dia pulley, 40x40x6mm angle and T-iron guide sufficiently long at the top and bottom respectively, channels & with bolts, nuts, rivets, locking arrangement, stoppers, handles, hold fast including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as required. |
| 21 | Providing and fixinf MS grills of required pattere in frames of windows etc with MS Gflate square or round bars etc. all complete. Fixed to Steel window by welding |
| 22 | Providing and fixing corrugated G.S. Sheet roofing fixed with polymer coated J or L hooks 8 mm diameter, bolts and nuts 6 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with lead and including a coat of approved steel primer and two coats of approved epoxy paint on overlapping of sheets complete ( upto a pitch of 60 degrees ) over a built structure including all types of necessary scaffoldings etc. but excluding the cost of the purlins, rafters and trusses etc.as per clauses of Chapter - 12 of CPWD specification.i) 0.63 mm thick with zinc coating not less than 275 gm / m2 |
| 23 | Providing and placing of G.I Pipe over the pump house on top portion of the RCC Column as per specification and the direction of the Engineer-in-charge. i) 100 mm dia |
| 24 | 12 mm cement plaster of mixi.) Cement mortar 1:6 ( 1 cement : 6 fine sand ) |
| 25 | 15 mm cement plaster on the rough side of single or half brick wall of mix:i. Cement mortar 1:6 ( 1 cement : 6 fine sand ) |
| 26 | 6mm cement Plaster of Mix In cement Mortor 1:4( 1 Cement:4 Fine Sand) |
| 27 | Neat Cement Punning |
| 28 | Providing and laying cement concrete 1:2:4 (1 cement: 2 fine sand : 4 graded well burnt brick aggregate) flooring finished with a floating coat of neat cement including cement slurry, rounding of edges and strips and cost of glass strips etc. completei) 40 mm thick |
| 29 | Distempering with oil bound washable distemper of approved brand and manufacture and of required shade on new work ( two or more coats ), over and including water thinnable priming coat to give an even shade. [Payment shall be made after submission of Test Certificate issued by the Manufacturer]a)New work ( two or more coats) over and including water thinnable priming coat with cement primer. |
| 30 | Finishing walls with water proofing cement paint of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer]a) New work (two or more coats applied @ 3.84 kg/10 sqm) |
| 31 | Painting with synthetic enamel paint of approved brand and manufacture colour to give an even shade ( Payment shall be made after submission of Test Vcertificate issued by the Manufacturer ) Two of more coats on new work over an under coat of suitable shade with ordinary paint ( Primer) of approved branf and manufacture |
| 32 | Labour Charge for disdmantling of 3 Nos IRP Vasels, pipe line gallery and diapharm valve as per direction of the Engineer in Charge |
| 33 | Labour Charge for Installation obf 3 Nos IRP Vasels, pipe line gallery and diapharm valve as per direction of the Engineer in Charge |
| 34 | Lifting of filter media from package type IRP filter chamber as per specification and the direction of the Engineer in charge. |
| 35 | Charges for spreading of filter media ( sand and gravel after proper cleaning and washing inside packege type IRP as per specification and the direction of the Engineer in charge( excluding the cost of sand and gravel) |
| 36 | Opening the oxidation vassel & mixing chamber , remove the old media scraping inside/out side clearing properly painting inside by anti corrosive black bituminous tic paint & painting outside & refilling fres media Mn02 required will be supplied by the Dept at free of cost complete s per direction of thge Engg in Charge. |
| 37 | Providing and placing rapid gravity filter sand having effective size of .50mm to 1.00mm & unuformity co efficient of not more than 1.70and less than 1.30 obtained from Barakar river West Bangal as per Specification and the direction of the Engineer in charge. |
| 38 | Providing and placing filter gravel having effective size of 3.00 mm to 25mm & uniformity co-efficent of not more than 1.7 and less than 1.30obtained from Barakar river, West Bengal as per specification and the direction of the Engineer in Charge. |
| 39 | Supplying and fitting fixing 4\\" diaphragm valve of approved quality as per direction of the Engineer in Charge |
| 40 | Providing and fitting fixing of CIDF Butterfly valve with bolts nuts rubber insertion etc. complete as per chapter 20of CPWD Specification and direction of the Engineer in Charge.i. 150mm dia |
| 41 | Mtc of Blowe compressor metering pump starter main swtch& electric wearing etc complete as per direction of the Engg in Charge |
| 42 | Providing and fixing MS bolts up to 300mm in length with nuts and washer complete as per clauses of chapter 101 of CPWD Specification |
| 43 | Supplying fitting fixing of strainer of approved quality as per direction of the Engineer in Charge |
| 44 | Providing and fitting fixing of pressure meter (0.00-14.00) kg/sqcm) as per specification and as per Specification and drection of the Engineer in Charge. |
| 45 | Providing and placing of anthracite coal(3mm to 6mm) of SP Gr. 1.4 in IRP as per Specification & direction of the Engineer in Charge |
| 46 | Providing and fixing C.I Sluice valve( with cap) complete with bolts, nuts rubber insertion etc. 9 the tail pieces if required will be paid separtely) as per CPWD specification and direction of the Engineer in Charge. |
| 47 | i. 125 mm dia A. PN - 1.6 |
| 48 | i. 150 mm dia A. PN - 1.6 |
| 49 | Steel work welded in built up section/frame work in/c cutting, hoisting fixing in position and applying a priming coat of approved steel primer using steel etc complete as required. i) granting, frames guard bar railling brackets gates and similar work all complete |
| 50 | Welding by Gas or Electric plant in/c transportation of plant at site etc. complete as per standard design |
| 51 | Providing and placing of MNO (20mm to 40mm) to be placed between 2 plates in the IRP as per Specification & direction of the Engieen in Charge. |
| 52 | Hiring charge of truck 10T capacity for carrying 3 nos IRP vassel as per direction of the Engineer in Charge |
| 53 | Providing and fixing MS bolts including nuts and washers complete as per standard design:- |
| 54 | Up to length 3000 |
| 55 | Above 300mm length |
| 56 | Supplying and fitting fixing of MS Flange of 8 mm wall thickness 150mm dia as per specification and direction of the Engineer in Charge |
| 57 | Charges for laying S & S Centrifugally Cast ( Spun ) Ductile Iron Class K-7 Pipes conforming to IS : 8329 as per CPWD specification and direction of the Engineer - in - charge.i. 150 mm dia |
| 58 | Hiring charge of Crane 8 T Capacity for lifting & loading2 nos IRP Vassels to truck as per direction of the Engieneer in Charge |
| 59 | Excavating trenches of required width for pipes, cables etc. including exacavation for sockets, dressing of sides where required, ramming of bottoms, depth upto 1500 mm (slope-1 in 200)including getting out the excavated soil and backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil with all required leads as per Chapter -2 of CPWD specification and direction of the Engineer - in -charge. In all kinds of soil |
| 60 | a. For UPVC pipes in new worki. For pipes not exceeding 90 mm dia |
| 61 | a. For UPVC pipes in new workii. For pipes exceeding 90 mm dia but not exceeding 300 mm dia |
| 62 | Labour Charge for Clearing of Clouded deposited iron in side PVC pipe 140mmdia,110mm dia,90mm Dia pipe by chain pully system in/c disposal of iron from the side and throughly washing the pipe with water complete as per direction of the Engineer in Charge |
| 63 | Providing and fixing hard drawn steel wire fabric of size 75x25mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of L shaped mild steel shear key welded withexisting reinforcement included the cost of materials labour tool & Plant as required and as per direction of the Engineer in Charge. |
| 64 | Providing and fitting fixing of air compressor 7.5 - 10.0 cfm with motor for 10,000 GPH capacity package type IRP in/c all necessary electric connections as per the direction of the Engineer in Charge. |
| 65 | Providing and fitting fixing of air blower of capacity 200.0 cum per hour for 10,000 GPH capacity package type IRP in/c all necessary electric connections as per the direction of the Engineer in Charge. |
| 66 | Providing and fitting fixing of SS solution tank of 50 Ltr. Capacity 10,000 GPH capacity package type IRP in/c all nesessary pipeline connections as per the direction of the Engineer in Charge. |
| 67 | Providing and fitting fixing of Direct on line (DOL) Motor starter L&T / BCH make ( 3 phase, 50 Hz, 415 V, 10 HP / 7.5 Kw relay range within 13-21 + 10%) in steel sheet enclosure in/c all necessary election connections as per the direction of the Engineer in Charge. |
| 68 | Providing and fitting fixing steel sheet enclosed switch fuse unit (suitable for DIN fuses), triple pole with Neutral Link (TPN), 415/500 Volt, L & T / Havells / BCH make etc. complete as per specification and direction of the Engineer-in-charge. i. 32 amps |
| 69 | Providing and fitting fixing of Metering pump with motor 0.30 to 30.0 LPH capacity for disinfection system of 10,000 GPH capacity Package Type IRP as per the direction of the Engineer in Charge. |
| 70 | Providing and fitting fixing of Metering pump with motor 6.00 to 25.0 LPH capacity for Mixing Chamber of 10,000 GPH capacity IRP as per the direction of the Engineer in Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
TodayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender