Tender For Construction Of Block Level Stadium (Without Indoor Hall) In Malkangiri Block Under Malkangiri District
Tender Value
7.88 Crore
Estimated cost
Bid Submission
31 Jul 2026
1 days left
EMD
7.88 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Malkangiri → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Block Level Stadium (Without Indoor Hall) In Malkangiri Block Under Malkangiri District
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL WORK Excavation in all kinds of soil with hydraulic excavator (1 cum capacity) including cutting and loading in tippers, trimming bottom and side slopes ,in accordance with requirements of lines,grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m.work complete as directed by the Engineer in charge. FOOTBALL FIELD |
| 2 | ATHELETIC TRACK |
| 3 | VOLLEY BALL COURT |
| 4 | KHO KHO ,KABADDI COURT |
| 5 | CUTTING FILLING |
| 6 | RETAINING WALL (PERIPERIAL) |
| 7 | RETAINING WALL (INTERNAL) |
| 8 | Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300 2 for embankment construction as directed by the Engineer in charge. FOOTBALL FIELD |
| 9 | FOOTBALL FIELD PATHWAY |
| 10 | ATHELETIC TRACK |
| 11 | VOLLEY BALL COURT |
| 12 | KHO KHO ,KABADDI COURT |
| 13 | PARKING |
| 14 | PAVER ROAD |
| 15 | Supplying and fixing of needle punched staple fiber non woven geotextile fabric under the fabric formed mattress, conforming to the following specifications:Minimum mass: 200GSM (MARV Mean Average Roll Value), Minimum thickness: 0.75 mm Grab tensile strength: 700 N as per ASTM D 4632 Grab elongation: 50 percent as per ASTM D 4632 Trapezoidal tear strength: greater than 250 N as per ASTM D 4533 CBR puncture resistance: greater than 1800 N as per ASTM D 6241 Minimum wide width tensile strength: 12 kN/m. The geotextile shall be needle punched staple fiber non woven type, suitable for separation, filtration, and protection applications, and shall be installed as per detailed site requirements and technical specifications, including proper surface preparation, laying, jointing, and anchoring as per directed by the Engineer in charge. make GEOQUEST,SOLMAXFOOTBALL FIELD |
| 16 | Construction of granular sub base by providing Close graded Granular subbase Grading III material as per table 400 1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MoSRT andH Specifications for Road and Bridge works (5th Revision) etc complete as per direction of Engineer in charge. Atheltic trackFOOTBALL FIELD PATHWAY |
| 17 | ATHELETIC TRACK |
| 18 | VOLLEY BALL COURT |
| 19 | KHO KHO ,KABADDI COURT |
| 20 | PARKING |
| 21 | PAVER ROAD |
| 22 | Providing, laying, spreading and compacting graded stone aggregate to laying in uniform layers in subbase/ base course on well prepared surface and compacting with vibratory roller to achieve the desired density etc.including cost of all labour,material,conveyance,loading and unloading,machinery charges all complete as per the direction of Engineer in charge.FOOTBALL FIELD |
| 23 | Supplying , stacking and spreading of good earth at site within initial lead including royalty and carriage transporting to site, spreading, grading to required slope and compacting to meet requirement.FOOTBALL FIELD |
| 24 | ATHELETIC TRACK |
| 25 | VOLLEY BALL COURT |
| 26 | KHO KHO ,KABADDI COURT |
| 27 | Supplying , stacking and spreading of root zone sand as per USGA standard at site including royalty and carriage and Laying of root zone sand on the top of aggragate as per desired level.FOOTBALL FIELD |
| 28 | Supply and laying of labour and material for Base preparation of grassing and fertilizer apllication in the required proportion specified or directed by the Officer in charge. |
| 29 | Supply and Planting Bermuda grass on site by Planting method directed by engineer in charge. The grass must be weed fee. Rate including all required fertilizer, pesticider and Chemical etc. complete for growing the turf. Spec. No.: As directed by Engineer in charge. (Including cost of 6 month of Maintenance of football Ground) FOOTBALL FIELD |
| 30 | Supplying, stacking, laying and compaction of a consolidated layer, 50 mm thick, of graded material of 4.75 mm to 2.36 mm mixed with cohesive material for stability and grip, etc., as per the direction of the engineer in charge.ATHELETIC TRACK |
| 31 | VOLLEY BALL COURT |
| 32 | KHO KHO ,KABADDI COURT |
| 33 | Providing and laying in trenches DWC perforated pipeat 100mm dia conforming to IS 16098 (Part 2) with all fitting accessories and jointing, including testing as per specification complete. (Earth work in trenches to be measured and paid fo separately).The cost inclusive of labour,material,fitting and fixing,conveyance,loading and unloading etc all complete as per the direction of Engineer in charge. |
| 34 | Providing and laying in trenches DWC non perforated pipeat 110mm dia conforming to IS 16098 (Part 2) with all fitting accessories and jointing, including testing as per specification complete. (Earth work in trenches to be measured and paid fo separately).The cost inclusive of labour,material,fitting and fixing, conveyance, loading and unloading etc all complete as per the direction of Engineer in charge. |
| 35 | Providing and laying in trenches DWC non perforated pipeat 160mm dia conforming to IS 16098 (Part 2) with all fitting accessories and jointing, including testing as per specification complete. (Earth work in trenches to be measured and paid fo separately).The cost inclusive of labour,material,fitting and fixing, conveyance, loading and unloading etc all complete as per the direction of Engineer in charge. |
| 36 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness. VOLLEY BALL COURT |
| 37 | KHO KHO ,KABADDI COURT |
| 38 | PARKING |
| 39 | PAVER ROAD |
| 40 | Earth work in excavation of foundation trenches in all kind of soil including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site within 50m initial lead and 1.5m initial lifts with sundries and T andP required for the work complete including cost of all labour,labour cess,T andP,sundries etc. as directed by the Engineer in charge.FACILLITY CENTRE |
| 41 | SECURITY ROOM AND GATE COMPLEX |
| 42 | FOOTBALL GROUND PATHWAY |
| 43 | FOOTBALL GROUND PERIPHERIAL DRAIN |
| 44 | PARKING |
| 45 | PAVER ROAD |
| 46 | DARINAGE PERIPHERIAL |
| 47 | Filling in foundation trenches and plinth, with excavated earth including laying the earth in layers not exceeding 23.5 cm thick ramming and watering with all leads and lifts including cost of all labour,T andP completed as directed by the Engineer in charge.FACILITY CENTRE |
| 48 | SECURITY ROOM AND GATE COMPLEX |
| 49 | FOOTBALL GROUND PERIPHERIAL DRAIN |
| 50 | PARKING |
| 51 | PAVER ROAD |
| 52 | DARINAGE PERIPHERIAL |
| 53 | RETAINING WALL PERIPHERIAL |
| 54 | RETAINING WALL INTERNAL |
| 55 | Supplying and filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyances, royalties of all materials and cost of all labour with T andP required for the work etc. complete as per specification and direction of Engineer in charge. FACILITY CENTRE |
| 56 | SECURITY ROOM AND GATE COMPLEX |
| 57 | FOOTBALL GROUND PATHWAY |
| 58 | PARKING |
| 59 | PAVER ROAD |
| 60 | DARINAGE PERIPHERIAL |
| 61 | CUTTING and FILLING |
| 62 | RETAINING WALL PERIPHERIAL |
| 63 | RETAINING WALL INTERNAL |
| 64 | Earthwork excavation of any approved type of soil in approved borrow area by mechanical means loading into transportation by mechanical means and unloading the soil within 5km lead on properly prepared . including spreading and leveling the earth in 22.5cm layers to make ready for watering and compaction with rollers and dozer etc.including all cost of labour , conveyance, royalties and taxes ,sundries ,T and P etc.complete as per the directions of Engineer in charge.CUTTING and FILLING |
| 65 | Providing and applying of pre constructional anti termite treatment by drilling 12mm dia holes at distance of 30cm at junction of wall and floor about 300mm apart deep enough to rEach the soil below and chemical emulsion (IMIDACHLOPRIED 30.5SC mixed with 47.5ltr water) pumped these holes to soak the soil at 1 ltr solution of Each hole as per manufactures specification and the holes should be pluged the filling materials including cost of all materials, labour,conveyance, T andP , all taxes and hire charges of machinaries as per direction of Engineer in charge.(make premise BAYER,Paxton FMC,ozie KALYANI). FACILITY CENTRE |
| 66 | SECURITY ROOM AND GATE COMPLEX |
| 67 | Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in Each layer including cost, conveyance, royalties of all materials and cost of all labours,labour cess, T andP etc complete as per the direction of the Engineer in charge. FACILITY CENTRE |
| 68 | SECURITY ROOM AND GATE COMPLEX |
| 69 | FOOTBALL GROUND PERIPHERIAL DRAIN |
| 70 | FOOTBALL GROUND PATHWAY |
| 71 | PARKING |
| 72 | PAVER ROAD |
| 73 | DARINAGE PERIPHERIAL |
| 74 | RETAINING WALL PERIPHERIAL |
| 75 | RETAINING WALL INTERNAL |
| 76 | Plain cement concrete (1:2:4) using 12mm size black hard crusher broken granite chips of approved quality from approved quarry including hoisting, lowering and laying concrete in layers, watering, curing etc. complete including cost, conveyance, royalties of all materials with labour,labour cess and T andP etc. required for the work complete as per the direction of the Engineer in charge. FACILITY CENTRE |
| 77 | Fly Ash brick masonry in cement mortar (1:6) in foundation and plinth using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2 percent including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T and P required for the work complete in all respect as per direction of Engineer in Charge. FACILITY CENTRE |
| 78 | SECURITY ROOM AND GATE COMPLEX |
| 79 | Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2 percent including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T and P required for the work complete in all respect as per direction of Engineer in Charge. FACILITY CENTRE |
| 80 | SECURITY ROOM AND GATE COMPLEX GROUND FLOOR |
| 81 | Fly Ash brick masonry in cement mortar (1:4) in super structure using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2 percent including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T and P required for the work complete in all respect as per direction of Engineer in Charge. FACILITY CENTRE |
| 82 | SECURITY ROOM AND GATE COMPLEX GROUND FLOOR |
| 83 | Providing, lifting, hoisting and laying Reinforced cement concrete of M 25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 percent ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T and P required of the work etc. complete in all respect as directed by the Engineer in Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position. FACILITY CENTRE FOOTING |
| 84 | PLINTH BEAM |
| 85 | COLUMN UP TO PLINTH LEVEL |
| 86 | LINTEL |
| 87 | ROOF SLAB |
| 88 | FIRST FLOOR COLUMN and BEAM |
| 89 | ROOF SLAB |
| 90 | SECURITY ROOM AND GATE COMPLEX GROUND FLOOR FOOTING |
| 91 | COLUMN UP TO PLINTH LEVEL |
| 92 | PLINTH BEAM |
| 93 | COLUMN UPTO ROOF LEVEL |
| 94 | LINTEL |
| 95 | CHAJJA |
| 96 | ROOF BEAM |
| 97 | ROOF SLAB |
| 98 | FOOTBALL FIELD DRAIN FOOTING |
| 99 | RCC WALL |
| 100 | RCC COVER SLAB |
| 101 | DRAIN FOOTING |
| 102 | RCC WALL |
| 103 | RCC COVER SLAB |
| 104 | RETAINING WALL (PERIPHERIAL) FOOTING |
| 105 | RCC WALL |
| 106 | RETAINING WALL (INTERNAL) FOOTING |
| 107 | RCC WALL |
| 108 | Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe 500D) etc. including bending, binding, welding, wastage and over lapping and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification and direction of Engineer in charge. FACILITY CENTRE GROUND FLOOR |
| 109 | SECURITY ROOM AND GATE COMPLEX |
| 110 | DRAIN FOOTBALL FIELD (PERIPHERIAL) |
| 111 | DRAIN |
| 112 | RETAINING WALL (PERIPHERIAL) |
| 113 | RETAINING WALL (INTERNAL) |
| 114 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T andP, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. FACILITY CENTRE GROUND FLOOR |
| 115 | SECURITY ROOM AND GATE COMPLEX |
| 116 | Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T andP, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. FACILITY CENTRE GROUND FLOOR |
| 117 | SECURITY ROOM AND GATE COMPLEX |
| 118 | Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping and slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour, T andP, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. FACILITY CENTRE GROUND FLOOR |
| 119 | SECURITY ROOM AND GATE COMPLEX |
| 120 | Fixing granite tiles of approved dimension area above 0.4 sqm (20mm thick) in floor, treads of steps and landing on 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects as per direction of Engineer in Charge. FACILITY CENTRE GROUND FLOOR |
| 121 | Fixing granite tiles of approved dimension area above 0.1 up to 0.4 sqm (10mm thick) in Dados, treads of steps and landing on 12mm thick cement mortar (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects as per direction of Engineer in Charge. FACILITY CENTRE GROUND FLOOR |
| 122 | Providing full body matt finish vitrified tile flooring using vitrified tiles having thickness of min 10mm conforming to IS 13755 of 600x600 of premium quality (JOHNSON / SOMANY/ KAJARIA/ RAK) in floors, treads on steps and landings on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the vitrified tile if required , watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,Labour cess , sundries, T andP required for the work, complete in all respect as per specification and direction of Engineer in charge. FACILITY CENTRE GROUND FLOOR |
| 123 | GATE and SECURITY ROOM GROUND FLOOR |
| 124 | Providing, fitting, fixing vitrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm homogeneous coloured/ printed series of approved make (JOHNSON / SOMANY/ KAJARIA/ RAK) as directed by Engineer in charge in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials all labour,labour cess complete in all respects. FACILITY CENTRE GROUND FLOOR |
| 125 | GATE and SECURITY ROOM GROUND FLOOR |
| 126 | Providing and laying best quality Vitrified floor tile of specified size of thickness 6 10mm of approved make confirming to IS 15622 specifications in floor over 20mm thick cement mortar (1: 4) to proper slope, line and level including cutting to required size and shape, fixing at corners and splays etc. Including finishing the joints with epoxy based water proofing grout to match the color and shade of tiles complete as per the design and drawing with cost of all materials, labour, conveyance T andP etc. All complete as per the direction of Engineer in charge. (Toilet)Make : Kajaria, RAK, Johnson FACILITY CENTRE GROUND FLOOR |
| 127 | Fixing of Ceramic wall tiles of premium grade having thickness 6.50mm to 7.00mm confirming to IS 13753 of size 60cm x 30cm special plain / printed series in dados skirting and riser of steps on 12mm thick cement plaster 1:3 joined with neat cement slurry mixed with pigments to match the shade of the tiles, including rubbing and polishing etc. complete including cost, conveyance, royalties of all materials, labour with T andP complete in all respects as per direction of Engineer in Charge.(make Somany, Johnson, RAK, Kajaria) FACILITY CENTRE GROUND FLOOR |
| 128 | Fixing of Kota tiles of minium thickness 16mm thick of premium grade of size above 0.10 Sqm. in floors over 20mm thick bed of cement mortar 1:4 (1cement:4course sand)and filling the joint with white cement mixed with pigments to match the shade of the tiles, including rubbing and polishing etc. complete including cost, conveyance, royalties of all materials, labour,labour cess with T andP complete in all respects as per direction of Engineer in Charge. FACILITY CENTRE GROUND FLOOR |
| 129 | Fixing of Kota tiles of minium thickness 16mm thick of premium grade of size above 0.10 Sqm. in Dado over 12mm thick bed of cement mortar 1:3 jointed with cement slurry mixed with pigments to match the shade of the tiles, including rubbing and polishing etc. complete including cost, conveyance and royalties of all materials, labour,labour cess with T andP complete in all respects as per direction of Engineer in Charge.INDOOR HALL GROUND FLOOR FACILITY CENTRE GROUND FLOOR |
| 130 | Supplying, fitting and fixing vetrified Industrial tiles in floors of premium grade having thickness 8mm to 10mm of size 300mm x 300mm confirming to IS 4457 with colour / printed series of approved make (JOHNSON /RAK / SOMANY/ KAJARIA ) on 20mm thick bed of C.M. (1:4) including cost of all materials, labour, T andP etc. required for the work in all respect as directed by the Engineer in charge.INDOOR HALL GROUND FLOOR FACILITY CENTRE GROUND FLOOR |
| 131 | Supplying, fitting and fixing Dressed seasoned sal wood (50mm. to 150mm. and above 2.75m. long.) work framed and fixed (wrought and put up) in Trusses, purlins, frames of doors, windows, ventilators and beams. FACILITY CENTRE GROUND FLOOR |
| 132 | GATE and SECURITY ROOM GROUND FLOOR |
| 133 | Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete in all respect as per the direction of the Engineer in Charge.INDOOR HALL GROUND FLOOR FACILITY CENTRE GROUND FLOOR |
| 134 | GATE and SECURITY ROOM GROUND FLOOR |
| 135 | Supplying and fixing of Powder coated 50 60 microns approved colour of Aluminium 40mm Casement series Door Unit with suitable aluminium extrude profiles. the system is designed to accommodate 12mm clear toughened glass of make Saint gobain/AIS/Gardian/modi. the rate quoted inclusive of hardwares like antilift,roller, Espag lock cum handle,epdm gaskets,T mullion ,Fly Mullion ,bottom adopter ,mid transom ,glazing clip for 12 mm glass felt along with all accessories etc complete. the gap between the wall and window will be filled with silicon weather sealant in the outer side. Casement Door Outer frame 40mm x 45.3mm Series x 1.4mm thickness, Fly mullion 44 x 60 mm x 1.4mm thickness, T Mullion 40 x 78.4mm x 1.4mm thickness, Transom 40.28 x 125.8 x 1.75 mm thickness, Bottom adopter 34.6 x 26 x 1.5mm thickness, including cost of all materials, all labour, sundries, T andP etc. complete in all respect as per direction of Engineer in Charge.(make Jindal,Hindalco,schueco). FACILITY CENTRE GROUND FLOOR |
| 136 | Supplying and installing UPVC 3 track 3 shutter sliding windows with Outer dimension 104 x 49 sash dimension of 61mm x 39mm for windows with corners fusion welded, fully reinforced with Galvanized steel of 1.2 mm to 2 mm. The sash will be fitted with 5mm reflective toughened glass . The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent including cost of all materials, all labour, sundries, T andP etc. complete in all respect as per approved drawing and direction of Engineer in Charge.(Make (Make FENESTA/ Koemmerling/ Saint Gobain/ Prominance). FACILITY CENTRE GROUND FLOOR |
| 137 | GATE and SECURITY ROOM GROUND FLOOR |
| 138 | Supplying and installing UPVC Ventilator windows having section of 55 mm x 50 mm for windows with corners fusion welded, fully reinforced with Galvanized steel of 1.2 mm to 1.5 mm. The outer will be fitted with 3.5mm pinhead glass . The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent including cost of all materials, all labour, sundries, T andP etc. complete in all respect as per approved drawing and direction of Engineer in Charge. (Make (Make FENESTA/ Koemmerling/ Saint Gobain/ Prominance). FACILITY CENTRE GROUND FLOOR |
| 139 | Supplying, fitting and fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and design with cost of all materials and labour, labour cess, T andP, sundries etc. complete in all respect as per specification and direction of the Engineer in Charge. FACILITY CENTRE GROUND FLOOR |
| 140 | GATE and SECURITY ROOM GROUND FLOOR |
| 141 | Priming one coat with wall cement primer (water bound) to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary and cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess T andP etc. complete as per the direction of the Engineer in charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer in Charge). FACILITY CENTRE GROUND FLOOR |
| 142 | GATE and SECURITY ROOM GROUND FLOOR |
| 143 | Wall painting two coats with Antifungal weather coat paint (1st quality) exterior grade of approved make and approved shade over a coat of primer to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T and P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer in Charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer in Charge). FACILITY CENTRE GROUND FLOOR |
| 144 | GATE and SECURITY ROOM GROUND FLOOR |
| 145 | Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make (JK White/ Birla white or equivalent make duly approved by Engineer in Charge) and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T andP etc. required for the work complete in all respect as per the direction of the Engineer in charge. FACILITY CENTRE GROUND FLOOR |
| 146 | GATE and SECURITY ROOM GROUND FLOOR |
| 147 | Painting two coats with plastic emulsion paint with a approved quality primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary and cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T andP etc. complete as per the direction of the Engineer in charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer in Charge). FACILITY CENTRE GROUND FLOOR |
| 148 | GATE and SECURITY ROOM GROUND FLOOR |
| 149 | Painting two coat with approved synthetic enamel paint to new wood work over a coat of Red oxide primer including cost, conveyances, royalties, taxes of all materials and cost of all labour with T andP required for the work etc. complete as per specification and direction of Engineer in charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer in Charge). FACILITY CENTRE GROUND FLOOR |
| 150 | GATE and SECURITY ROOM GROUND FLOOR |
| 151 | Painting two coat with approved synthetic enamel paint to new iron work over a coat of Red oxide primer including cost, conveyances, royalties, taxes of all materials and cost of all labour with T andP required for the work etc. complete as per specification and direction of Engineer in charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer in Charge). FACILITY CENTRE GROUND FLOOR |
| 152 | GATE and SECURITY ROOM GROUND FLOOR |
| 153 | FOOT BALL PATHWAY |
| 154 | PAVER ROAD |
| 155 | PARKING |
| 156 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm at 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, cost of all labour,labour cess, T andP etc. required for the work complete in all respect as per direction of the Engineer in charge. (Make JINDAL) FACILITY CENTRE GROUND FLOOR |
| 157 | Providing 2.5cm thick Grading Concrete over roof slab with cement concrete (1:2:2) using 6mm size black hard granite crusher broken chips and screened and washed sharp sand for mortar and finished smooth to the rough surface of slab including watering and curing with cost, conveyance, royalties of all materials with cost of all labour, labour cess and T andP required for the work etc. complete in all respect as directed by the Engineer in charge. FACILITY CENTRE GROUND FLOOR |
| 158 | Waterproofing application: Providing and application of two component polymer modified flexible cementitious waterproofing coating at a thickness of 1.5 2.5 mm The membrane should have Elongation equal or more than: 30 percent Crack Bridging ability : Up to 1 mmAdhesive strength: 1.0 N/mm² at 28dTensile elongation: 60 percent at 20°CShore A Hardness greater than85 (between 3 7 days)etc. as per direction of E.I.C (For longer span, in terrace panel of 4m*4m should be done by groove cutting, and filling with PU Sealant)(make Myk,Fosroc,Sika). INDOOR HALL FACILITY CENTRE GROUND FLOOR |
| 159 | Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand (zone III) : 4 graded stone aggregate 6 mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits. FACILITY CENTRE GROUND FLOOR |
| 160 | Providing and fixing Greenlam Sturdo Vibrance Serene Toilet Cubicle (of following standard dimension which includes 600mm door size width) made of heat, bacteria, water, chemical, scratch, impact and anti bacterial, anti virus, anti fungal resistant 12mm thick solid compact laminate panels tested by Shriram Test House. Finish of the compact laminate should be Suede / Raw Silk, which includs doors, pilasters and intermediate panels finished with approved texture/shade as per the detail drawings and as per IS 2046 (Indian Standard) and as per fire retardant BS 476/97 standard. The product should have Green Guard Certificate. Reduction of virus in 2 hours and 24 hours when tested by ISO 21702: 2019 standard.This also includes providing and fixing in position necessary hardware made out of Nylon Polymide Grade 6 and Aluminium powder coated top rail as per manufacturers specifications and Architects instructions like (1) Nylon Door Knob, (2) Nylon Gravity hinges, (3) Nylon Thumb turn lockset indicators, (4) Aluminum Powder Coated Top Rail, (5) Nylon Coat Hooks, (6) U Channels, (7) Nylon Adjustable Foot, (8) Noise Deafening Tape etc. (9) Screws and wall Plugs.The top fitting should consist of Aluminium Powder Coated top rail which will get fixed with Mid and End pilasters. All other hardware and screws will of stainless steel in 304 Grade with satin finish. Top rail is extruded Aluminium will be powder coated or anodized (Grade 6063 Micron Aluminium). All pilasters are supported by grade 6 Nylon Polymide Thermoplastic palm design pedestal footing with non corrosive steel inserts. The base diameter 65mm and neck diameter of 33mm anchored to the floor with grade 304 satin finish stainless steel screws with push fit capping at a clearance height of 150mm. Model is Heat and Bacteria Resistant Polymide in which aluminium U Channel will be used for the fixing of intermediate panels to the wallINDOOR HALL FACILITY CENTRE |
| 161 | Providing and fixing Urinal partition Made of 12 mm thick compact laminate thotal height 1195 mm , Depth 450 , Gap from ground 500 to 600 mm,Stainless steel L clamp is used to attach the divider to the wall, stainless steel L clamp hardware fittings along with Su 316 screws are used to fix the Urinal partitions on the wall. FACILITY CENTRE |
| 162 | Aluminum Fixed Curtain Glazing : Providing and fixing Anodized System Aluminum curtain glazing, suitable for 2.4 KPA wind load. The extruded aluminium sections should be made from Grade 6063 T5 and Anodized with Tex guard coating. Corner connection will be Butt joint with using Nano gaskets for sealing. There shall be no visible joineries in any intermediate section. All other major Accessories should also be made by the same manufacturer. The outer frame Depth will be 100 +/ 5 mm with minimum transom / mullion size of 100 mm x 70 mm or 200 x 70 for height exceeding 3000 mm. All glasses will be 22 mm DGU Ref Toughened ST 146 and to be fixed from outside only.The system should allow glass thickness up to 12 mm. The system should qualify Airtightness ASTM E283: 10.7m3/h.m2 at 75Pa of pressure, Water tightness ASTM E300: 240 Pa, Wind load resistance ASTM E330: 2400 Pa. FACILITY CENTRE GROUND FLOOR |
| 163 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, laying in uniform layers with paver in subbase/ base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per Clause 406 of MoSRT andH Specifications for Road and Bridge works (4th Revision). PARKING |
| 164 | PAVER ROAD |
| 165 | Providing and laying of 80mm thick factory made cement concrete interlocking Paver block of M 40 grade and approved make ,variety,colour and size made by block making machine with strong vibratory compaction of approved design and shape laid in required colour and pattern over 50 mm thick compacted bed of coarse sand filling the joint with fine sand etc.all complete including cost ,conveyance ,royalty of all materials, labour,T andP etc.Complete as per direction of all Engineer in charge. PARKING |
| 166 | PAVER ROAD |
| 167 | FOOTBALL GROUND PATHWAY |
| 168 | Supplying and fixing of precast kerb stone of size 600mm x 300mm x 150mm of M 30 grade of approved make ,design,colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984. PARKING |
| 169 | PAVER ROAD |
| 170 | FOOTBALL GROUND PATHWAY |
| 171 | Construction , Providing , Supplying and fixing the pre cast , pre tensioned SFRC compound wall poles having finished dimention of 2000mm x 200mm x 50mm long, (providing the construction joint at the interval of 15.4 mtr) made in M 30 grade concrete with 10 Nos of 4mm dea. HTPC ( High Tension Pre Coated) wire, fixed in cast in situ PCC m 20 concrete in foundation footing of size 600 mm dia 750 mm depth from top inside the pre cast RCC collar ( NP 2) of 600 mm Internal dia. and length of 750 mm placed over a base of PCC (1:4:8) of size 680mm dia, 100 mm depth including excavating foundation pit for Each pole, kind of soil of size 680mm dia, 850mm depth ( at expansion joint of 15.4 m interval where combined poles are to be places with 900mm internal dia of NP 2 collar of 750mm height) including watering and curing for required days along with supplying, fitting and fixing of pre cast , pre tensioned, SFRC slab having dimention of 2100mm (long) x 300mm (Wide)x 50 ( thick) 7.5 Nos. per span, made with M 30 grade concrete with 4mm dia. GI HTPC wire 4 Nos. covering the top of the compound wall poles with a pre cast SFRC cover of size ( 300x300x150) mm in order the prevent the slab panels from removing . all complete as a set to be measured in term of running meter including such pre cast , SFRC top cover, slab, pole, including painting two coats of approved weather coat paint over a coat of wall primer including curing cost and conveyance of all materials, royalties, taxes all labour, labour cess, T andP required for the work etc. complete including dewatering if required as per the direction of the Engineer in Charge(Excluding cost of GST) Compound wall |
| 172 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length (total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron Y shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer in charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre. Compound wall |
| 173 | Supply and Installation of AIFF/FIFA Compliant Portable and Movable Football Goal Post , Size 7.32 M X 2.44 M Inner to Inner, With 8 Inch Non Marking solid Galvanised Wheels for smooth movement, Main pipe made of 100mm Round Powder Coated High Grade Aluminium Alloy Pipe of 3mm thickness, Back Support made of 60mm Round Powder Coated High Grade Aluminium Alloy Pipe of 2.5 mm thickness, No sharp edges, All corners fully welded and ground smooth, 220 Pcs Polyproplene unbreakable net clips no sharp edges, including transportation, Installation, testing and commissioning as per Engineer In Charge Must be of reputed make like Stag Global, Nelco, SodexSport. SPORTS EQUIPMENT |
| 174 | Supply and Installation of FIVB Compliant Portable and Movable telescopic Volleyball Post, Made of heavy duty 100mm round Aluminium Alloy Pipe with crank system for height adjustment 2.43 m for mens and 2.24m for womens, With 120kgs Weight Stacks for stability. Steel pulley on top, including transportation, Installation, testing and commissioning as per Engineer In Charge. Must be of reputed make like Stag Global, Nelco, Senoh SPORTS EQUIPMENT |
| 175 | Supply and Installation of Kho Kho Pole,Two rigid poles of 1.20 m height from ground level, Heavy Duty 4 inch Dia Smooth and Round Steel Uprights, No sharp edges to prevent injury. Must be of reputed brands like Nelco, StagGlobal, Gravolite SPORTS EQUIPMENT |
| 176 | Supply and Installation of TTFI/ITTF Certified Table Tennis Table, Size 274cm X 152.5cm X 76cm, 25mm Top to ensure consistent bounce and optimal Spin Performance. 25 X 50 mm Heavy duty alloy steel frame for superior durability and strength. Smooth, Axalta Polyurethane Anti Glare top Finish for clear visibility and accurate play. Top Colour Black. Must have 100 mm eight wheels for easy mobility, with four being lockable for added stability. Premium Professional T T Tables with Foldable Design. N. W. / G. W. 116 Kgs / 123 Kgs, including transportation, Installation, testing and commissioning as per Engineer In Charge. Make Stag Global, Donic or Stiga SPORTS EQUIPMENT |
| 177 | Supply and Installation of BWF Certified Movable Badminton Post With 80 Kg Cast Iron Base for stability, 75 mm Nylon Wheels and Anti Stick PU Rubber Sheet Inside Base and Weights. 95x46mm Square Steel Pipe Connecting the Base and Uprights. 39mm Round Uprights of 4mm thickness. Uprights Height Must be 1.55 Mtr. Stainless Steel Pully Strong System. Powder Coated Rustproof. Must be approved by BWF. Make Yonex AC 357 1, Stag Global SGBAPO10, Li Ning OP80 SPORTS EQUIPMENT |
| 178 | Providing, supplying Nyon BADMINTON NET With 4 side tape (Tournament Quality) of approved quality, size as per specificationand direction of Engineer In ChargeMust be Approved by BWFMust be of reputed make like Yonex, Li Ning, Cougar. SPORTS EQUIPMENT |
| 179 | Providing, supplying Badminton racket of approved quality, size as per specification and direction of Engineer In Charge.Must be of reputed make like Yonex, Vextor X or Li Ning. SPORTS EQUIPMENT |
| 180 | Providing, supplying Nylon Shuttle Cock Tournament approved quality, size as per specificationand direction of Engineer In Charge.Must be of reputed make like Yonex, Li Ning, Vector X. SPORTS EQUIPMENT |
| 181 | Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type IV of ASTM D 4956 01 in blue and silver white or other colour combination including subject matter, message (bi lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class 2 of ASTM D 4956 01 and fixing the same with suitable sized aluminium alloy rivets at 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing and fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand and manufacture over priming coat of zinc chromate yellow primer (vertical MS Tee support to be painted in black and white colours).Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing, specification and direction of Engineer in charge. Mandatory/ Regulatory sign boards of 900 mm diametre with support length of 3750 mm. a)Mandatory/ Regulatory sign boards of 900 mm diametre with support length of 3750 mm |
| 182 | b)Cautionary /warning sign boards of equilateral triangular shape having Each side of 900 mm with support length of 3650 mm |
| 183 | Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type III of ASTM D 4956 01 as approved by Engineer in charge, letters, borders etc. as per IRC : 67 2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM D 4956 01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts and nuts at 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer incharge.( Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment). SIGNAGES |
| 184 | Providing Retro reflective regulatory sign board of size 900 mm dia meter made out of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated lens type retro reflective sheeting as approved by Engineer in charge . Letter, symbols, borders etc. will be as per IRC 67 with required colour scheme on the boards and with the high intensity grade A. The aluminium sheet to be riveted to M.S. frame of angle iron of size 40x40x4 mm. The boards will be fixed to 1 No. 50x50 mm square post made of M.S. angle 50x50x4 mm, 4 m long welded to the frame with adequate anti theft arrangement .Sheet work to be painted with two or more coats of synthetic enamel paint over an under coat (primer) and back side of aluminium sheet to be painted with two or more coats of epoxy paint including appropriate priming coat complete in all respects as per direction of Engineer in charge. SIGNAGES |
| 185 | Providing and fixing post delineators made of ABS round body fitted with 2 nos 100 mm dia high reflective reflectors and mounted on MS pipe of 65 mm dia duly powder coated anti rust and anti theft steel to be installed as per direction of Engineer in charge. SIGNAGES |
| 186 | Providing and fixing letters made out of acrylic sheet with light arrangement as per the architectural drawing/design complete with all materials cost, coveyance, loading and unloading, royalties and cost of all labour, T andP, sundries, with necessary scafolding and accessories complete in all respects as per the direction of architect / engineer in charge.600mm height. SIGNAGES |
| 187 | b)300mm height |
| 188 | Plastic Waste bin Rectangular alongwith fabricated MS stand with one coat of primer and two coats of enamel paint for stand. MS stand should be grouted properly on the ground level. Capacity 60 350x350 mm Top Dia.250x250 mm Bottom Dia.850 mm Height pair Sintex, Nilkamal, Otto, Aristo SIGNAGES |
| 189 | Plastic Waste bin without Wheel with Push type Top load along with fabricated MS stand with one coat of primer and two coats of enamel paint for stand. MS stand should be grouted properly on the ground level capacity 60 pair 350x350 mm Top Dia. 250x250 mm Bottom Dia. 850 mm Height Sintex, Nilkamal, Otto, Aristo SIGNAGES |
| 190 | Plastic Waste bin without Wheel with Swing lid type Top load along with fabricated MS stand with one coat of primer and two coats of enamel paint for stand. MS stand should be grouted properly on the ground level. Capacity 60 pair 350x350 mm Top Dia. 250x250 mm Bottom Dia. 850 mm Height Sintex, Nilkamal, Otto, Aristo SIGNAGES |
| 191 | Trenching in ordinary soil upto a depth of 60 cm including removal and stacking of serviceable materials and then disposing of by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge of land manure before and after flooding trench with water (excluding the cost of imported earth, sludge or manure). LANDSCAPE |
| 192 | Supplying and stacking of good earth at site (Earth measured in stacks will be reduced by 20 percent for payment) with all lead and lift. LANDSCAPE |
| 193 | Supplying and stacking sludge at site (sludge measured in stacks will be reduced by 8 percent for payment) with all lead and lift. LANDSCAPE |
| 194 | Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8 percent for payment).Screened through sieve of I.S. designation 20 mm. LANDSCAPE |
| 195 | Screened through sieve of I.S. designation 16 mm LANDSCAPE |
| 196 | Screened through sieve of I.S. designation 4.75 mm LANDSCAPE |
| 197 | Rough Dressing the trenched ground including breaking clods etc.all complete as per the direction of Engineer in charge. LANDSCAPE |
| 198 | Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. LANDSCAPE |
| 199 | Fine dressing of the ground LANDSCAPE |
| 200 | Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer in charge (cost of sludge, dump manure and/ or good earth to be paid separately). LANDSCAPE |
| 201 | Mixing earth and sludge or manure in proportion specified or directed.. LANDSCAPE |
| 202 | Providing and laying Selection no. 1 grass turf with earth 50mm to 60mm thickness on existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same, as per direction of officer in charge LANDSCAPE |
| 203 | Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer in charge. LANDSCAPE |
| 204 | Renovating lawns including weeding, cheeling the grass, forking the ground, top dressing with sludge or manure, mixing the same with forked soil, watering and maintaining the lawn for 60 days or more till the grass forms a thick lawn free from weeds and fit for mowing and disposal of rubbish as directed, including supplying good earth if needed but excluding the cost of sludge or manure (The manure/sludge shall be paid for separately). LANDSCAPE |
| 205 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20 percent : 1 part of stacked volume of manure after reduction by 8 percent) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately). Holes 60 cm dia, and 60 cm deep LANDSCAPE |
| 206 | Holes 45 cm dia, and 45 cm deep LANDSCAPE |
| 207 | Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of Each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer in charge. LANDSCAPE |
| 208 | Providing Circular Cement Concrete pots of specified size, cast with cement concrete of nominal mix 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size), reinforced with 7 Nos ( 3 nos horizontal and 4 nos vertical U shape) M.S. wires of 3.5 mm dia as per design, including required form work, finishing with cement punning on exposed surface, curing for specified period and stacking in required rows and height, all complete as per direction of Officer in charge.Top inside dia 35 cm, outer bottom dia 25 cm, total height 35 cm with wall thickness of 25.4 mm LANDSCAPE |
| 209 | Filling of the following size empty pots with mixture of good earth and manure in the ratio of 2:1 (Two part of Good earth and one port of manure) and placing them on appropriate place i/c carriage of earth, manure and pots up to 50 mtr, as per direction of officer incharge. (The cost of good earth, earthen pots and manure will be paid separately.) Size of Empty Pots 35cm Top dia, 25cm Bottom Dia and 35cm Perpendicular height. LANDSCAPE |
| 210 | Anti termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20 percent EC in the ratio of 1 percent concentration and as per direction of officer in charge. LANDSCAPE |
| 211 | Anti termite treatment of lawn area through premise 30.50 percent I P. one liter premise diluted in 499 liters water and applying solution at 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer in charge.and as per direction of officer in charge. LANDSCAPE |
| 212 | Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable materials as per direction of officer in charge (excluding cast of plant and water). LANDSCAPE Trees Plant |
| 213 | Shrubs Plant |
| 214 | Hedge Plant |
| 215 | Providing and displaying of Aglaonema dove variety Plant, having ht. 30 cm to 45 cm with 8 to 10 leaves, well developed, fresh and healthy in 25 cm size of Earthen pot / Plastic pot and as per direction of the officer in charge. LANDSCAPE |
| 216 | Providing and displaying of Aglaonema Snow White hybrid plant (three in one), having ht. 30 cm and above with 6 to 8 leaves, bright colour, well developed, fresh and healthy in 25 cm size of Earthen pot / Plastic pot . (Specimen Plant) and as per direction of the officer in charge. LANDSCAPE |
| 217 | Providing and displaying of Areca Palm plant, having ht. 90 cm to 1.20 m with 4 to 5 suckers, well developed, fresh and healthy with lush green foliage in 20 cm size of Earthen pot / Plastic pot and as per direction of the officer in charge. LANDSCAPE |
| 218 | Providing and displaying of Croton Challanger variety plant, having ht. 30cm and above, well developed with full of fresh and healthy leaves in 20 cm size of Earthen pot / Plastic pot and as per direction of the officer in charge.. LANDSCAPE |
| 219 | Providing and displaying of Croton Baby Golden plant (three in one), having ht. 30cm, multi branches, well developed with fresh and healthy foliage in 25 cm size of Earthen pot / Plastic pot. as per direction of the officer incharge. LANDSCAPE |
| 220 | Providing and displaying of Dracaena Song of India plant (three in one), having ht. 30 cm and above, multibranched, well developed with fresh and healthy leaves in 25 cm size of Earthen pot / Plastic pot and as per direction of the officer in charge. LANDSCAPE |
| 221 | Providing and displaying of Money Plant Broad Leaves mounted on moss stick 90 cm ht., 3 to 4 plants in Each pot, well developed with full of fresh and healthy leaves in size of 25 cm Top dia x 18 cm Bottom dia x 25 cm Perpendicular height Earthen pot / Plastic pot . and as per direction of the officer in charge. LANDSCAPE |
| 222 | Providing and displaying of Phoenix palm plant, having ht. 75 cm to 90 cm with 10 to 15 or more leaves, well developed, fresh and healthy in 25 cm size of Earthen pot / Plastic pot and as per direction of the officer in charge. LANDSCAPE |
| 223 | Providing and Displaying plants Cladium Hybrid variety 3 to 4 plants in a pot well developed with fresh and healthy foliage 30 to 45 cm ht. in different colour 25 cm Earthen Pot/Plastic Pot and as per direction of the officer incharge. LANDSCAPE |
| 224 | Providing and Displaying plants Cosmos well developed fresh and healthy 20 to 25 cm ht. attractive colours multi branching at blooming stage in 20 cm Earthen Pot/Plastic Pot and as per direction of the officer in charge. 3LANDSCAPE |
| 225 | Providing and Displaying plants Creeper Rose variety 3 to 4 healthy branch 60 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer in charge. LANDSCAPE |
| 226 | Providing and Displaying plants Standard Rose (H.T. variety) 3 to 4 healthy branch 90 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer in charge. LANDSCAPE |
| 227 | Providing and Displaying Acalypha green plant well developed, fresh and healthy with good foliage, multi branch 30 to 45 cm ht. in 20 cm size Earthen Pot/ Plastic Pot bushy plant as per direction of the officer in charge. LANDSCAPE |
| 228 | Providing and Displaying Bamboo Buddha vally variety with umbrella shape plant having 120 to 135 ht. with fresh and healthy foliage well developed in 40 cm Cement pot multy branch, bushy plant as per direction of the officer in charge. LANDSCAPE |
| 229 | Providing and fixing overhead type sprinkler system with self closing valve type 25mm X 20mm with self closing spring made up of alluminium alloy and brass fittings including cost of all materials, labour, T and P etc complete as per direction of Engineer in charge. LANDSCAPE |
| 230 | Supplying all materials, labour, T andP and fixing 15mm dia CP Bib cock of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering in charge. LANDSCAPE |
| 231 | Supplying all materials, labours, T andP and fitting and fixing of the 20mm dia CPVC pipe confirming to IS 15778 certification mark with socket and screw joints in walls and floors including supplying of required number of fittings of approved make including cutting threads to pipes and pipes to length, including wastage,etc for fitting to the walls with supply of holder ats, clamps, fixing wooden plugs in walls, including testing of pipe line for water tightness complete as per IS specification including cost, conveyance and taxes of all materials all complete as per PH specification and direction of Engineer in charge. (Concealed) LANDSCAPE |
| 232 | Chair BEAT HIGH BACK SEAT/ BACK ASSEMBLY: The seat and back is made up of 1.2 ± 0.1cm thk. hot pressed plywood measured as per QA method described in OCP QLTA PL14 18 ; upholstered with synthetic leather over moulded High Resilience . Fixed Armrest Top is PU moulded over metal insert.FRONT PIVOT SYNCHRO MECHANISM: The adjustable tilting mechanism is designed with the following features. 360° revolving type. Single point control. Front pivot for tilt with feet resting on ground ensuring more comfort. Tilt tension adjustment. 4 position locking with anti shock feature. Back height adjustability is applicable for for High back and Mid back chair.PNEUMATIC HEIGHT ADJUSTMENT: The pneumatic height adjustment has an adjustment stroke of 10.0 ± 0.3 cm. FACILITY CENTRE |
| 233 | Almirah Storwel Plain (1981H x 916W x 486D)Storwel plain shall have an overall size of 916mm(W)x486mm(D)x1980mm(H) with welded construction. It should have the shelf thickness of 0.7 mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high yield strength) and all other components shall have a thickness of 0.9mm. These components shall be made of CRCA D grade high yield strength as per IS:513. The Storwel Plain should have a Mazak handle and Three way locking mechanism with Shooting Bolts. It should have a height wise adjustable shelf mounting which shall have a Uniformly Distributed Load Capacity of max 40 Kg. It should also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated to the thickness of 50 microns (,/ 10). Plenty of colour options and shelving options shall be available. FACILITY CENTRE |
| 234 | FACILITY CENTRE |
| 235 | FACILITY CENTRE |
| 236 | 4 Door PLU LockerOverall size of 4 Door PLU + Lkr (Base) shall be 380mm(W)x450mm(D)x1830mm(H). Stackability shall have add on units that can be stacked width wise to form bank of lockers having common side panel. Locking shall have 10 Lever cam lock with lock lever plus option of hasp arrangement . Material shall be CRCA 0.6 mm thickness . Construction shall be Rigid Knockdown construction , shelf shall be uniformly distributed load capacity per Each shelf level is 35 Kg maximum . Finish shall be epoxy polyester powder coated to the thickness of 50 microns . Handle/Label holder shall be Aesthetically appealing Snap fit ABS plastic handle . Ventilation shall be attractive punched pattern for ventilation. FACILITY CENTRE |
| 237 | FACILITY CENTRE |
| 238 | Providing weep holes in Brick masonry /Plain/Reinforced concrete abutment,wing wall return wall with 100 mm dia PVC pipe,extendeding through the full width of the structure with slope 1V:20H towards drawing face,complete as per the drawing and direction of Engineer in charge.The cost inclusive of all material,pipe,fitting cost of all labour etc all complete. PERIPHERIAL RETAINING WALL |
| 239 | INTERNAL RETAINING WALL |
| 240 | ELECTRICAL COMMON FACILITY CENTER and GATE Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer in Charge. . All the switches and sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report and Warrnaty certificate to be submitted to the department for genuinity of product and to avail free after sales service within warranty period for acceptance of materials.Make of Modular GI box Make Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision)NB:All the electrical,Fire fighting,HVAC,ELV drawings,LUX Level design of the arena lighting, Technical Data Sheets and make will be approved by SE R and B Electrical circle and CE Building ,Odisha ,Bhubaneswar prior to execution of the work. GROUP A |
| 241 | GROUP B |
| 242 | GROUP C |
| 243 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch and socket (modular type)( ( flame retradant type)) and other required accessories of ISI marked as approved as per direction of Engg. in Charge. Make Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches and sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report and Warrnaty certificate to be submitted to the department for genuinity of product and to avail free aftersales service within warranty period for acceptance of materials. |
| 244 | Supply and fixing of ISI marked modular type 2nos 6Amp socket with switch on suitable size of metal box and modular cover in front on surface or recess including all conection as per direction of E.I.C. All the switches and sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report and Warrnaty certificate to be submitted to the department for genuinity of product and to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/ Schneider(Zencelo)/PANASONIC(VISION) |
| 245 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch and socket(modular type)( ( flame retradant type)) with suitable size modular box and cover( falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg in charge..Make Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches and sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report and Warrnaty certificate to be submitted to the department for genuinity of product and to avail free aftersales service within warranty period for acceptance of materials. |
| 246 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch and socket(modular type)(( flame retradant type)) with suitable size modular box and cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg in charge.. Make Schneider(Zencelo)/legrand( Myrius) (For equipement power)All the switches and sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report and Warrnaty certificate to be submitted to the department for genuinity of product and to avail free aftersales service within warranty period for acceptance of materials. |
| 247 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V guard in recessed HMS FRLS PVC conduit of mentioned size Make AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg. in Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 248 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V guard in recessed HMS FRLS PVC conduit of mentioned size Make AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg. in Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 249 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V guard in recessed HMS FRLS PVC conduit of mentioned size Make AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg. in Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 250 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V guard in recessed HMS FRLS PVC conduit of mentioned size Make AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg. in Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5) |
| 251 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg. in Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB) (4X6+2X4) |
| 252 | Supply, delivery, installation and testing of Modular G.I. box 18 SWG Sheet ISI marked with Modular base and cover for 2 moudle tv socket outlet.Make Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) |
| 253 | Wiring to Telephone Socket Outlet from Junction Box with 0.5 mm2 Four Pair Copper Conductor Telephone Wire run inside prelaid PVC Conduit complete including termination, testing etc complete as required and as per Direction of Engineer In Charge. |
| 254 | Supply, delivery, installation and testing of TV Antenna Wires RG6 in PVC Pipe and making good the damages caused complete as required and as per Direction of Engineer In Charge. |
| 255 | Supplying and installation of AC Point having 16 20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB of suitable size as required as per direction of Engg. in Charge .All the Components should be warrantied for a replacement period of 1 year against defects with ncessary test report and Warrnaty certificate to be submitted to the department for genuinity of product and to avail free aftersales service within warranty period for acceptance of materials. |
| 256 | Supply,installation, testing and commissioning of Air Cooled HI Wall split type Air conditioners complete with Indoor unit (IDU), Out door unit (ODU), i/c R 32/R 410/ R 407 Green Refrigerant, wireless Remote control, suitable for working between 180 260V with low and high voltage cut off and50 hz ,1 phase AC Supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100 percent of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS/ International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS :1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). The indoor outdoor must be Blue Fin coated. The unit price included with 3mtr Copper piping with insulation, drain Pipe and copper Power cable. The indoor should have 4 way swing . In case, the distance between ODU and IDU exceeds 3 mtr, then only the item of copper pipe shall be executed without any joint and equivalent mtr shall be deducted from the copper pipe item.1.5 TR with 5 Star BEE Rating (LG AS Q20JWZE/ O General ASGG18CGWA B/ Daikin FTKU50XV16) |
| 257 | Supply,installation of hard/soft ISI marked copper refrigerant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25 mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job. |
| 258 | Supply,installation and fabrication of MS base frame for outdoor unit and other nesessary material to complete the job. |
| 259 | Supplying and fixing of following sizes of HMS PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg. in Charge .Make AKG/BEC/Precision/Norpak/Kinjal.(Only for data, telephone, CCTV)20 MM |
| 260 | 25 MM |
| 261 | Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers(Make Havells/Crompton/Usha/Bajaj ) of exhaust fan in the existing wall, including fixing and conntection .as required as per direction of Engg. in Charge. Replacement Warranty will be 2 years. |
| 262 | Supply, Installation, Testing and Commissioning of Duct mounted Single skinned Circular Inline Centrifugal Fan for Toilet Ventilation with direct driven Backward curved impellers.The Fan has external rotor motor suitable for 1~, 230V, 50 Hz power supply. MAKE SYSTEMAIR/ GREENHECK/ ELTA/Airflow1500 CFM at 15mm MMWG static pressure |
| 263 | Supply and Fixing of Air Distribution Duting fabricated with Class VI GI Sheet(180 GSM) Complete With Supports, dampers, guiding vanes, access doors, MS Angle, Fire inhibiting gaskets, Nuts, bolts and all oyher accessories in accordance with approved drawing and the Specification. (Make: Jindal/ Sail/ Tata)22 gauge (0.80 mm thickness) |
| 264 | 24 gauge (0.63 mm thickness) |
| 265 | Supply, erection, testing and commissioning of Aluminium powder coated grills/diffuser without VCD having flange all around.Make Glenstorm/Airflow/Systemaire |
| 266 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery greater than equal to215m3/min Make Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg. in Charge,Replacement Warranty will be 4 years.(fan Regulator compatible) . |
| 267 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) |
| 268 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg. in Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 269 | SITC of Sleek LED 10 watt mirror light fitting with decorative aluminium LED batten having extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) |
| 270 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die cast Alluminium housing with high quality frosted diffuser for glare free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10 percent, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg. in Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 271 | Supply, Installation, Testing and Commissioning of of IP65 (10 12)w Bollard Fixture with Body made of Extruded Aluminium /Mild steel Pole and PDC Aluminium Housing for Optimal thermal Conductivity. With UV Stabilized Injection Moulded Diffuser for Soft and even light distribution. High Efficiency Driver with necessary safety Protection against Short Circuit, Miswiring,Over Voltage and Surge Protection of upto 10kV ( 4kV Internal and 10kV External SPD of IP67) THD<10 percent. CRI greater than70, PF greater than.95. CCT 5700/4000/3000K.Impact Resistance IK05.Operating Voltage Between (100 275)V. Avg life of 50,000 Burning HoursatL70.Both the light fixture and the Driver Should be BIS Approved.Before final procurement, the final design shall be approved by the concerned client and Engineer in charge. Make K LITE/Philips/LT/PANASONIC/Havells/Bajaj/Crompton/Wipro |
| 272 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439 3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make LEGRAND Ekinox3 DB/ Siemens Betaguard/ Schneider Acti 9 /ABB ITUS as per direction of Engg. in Charge. The Distribution boards should be Replacement Warranty will be 3 years.4 Way(8+(4x3)+(3x4)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439 3 with configuration of incomming I 8 modules,sub incommer 12 module and out going 12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for Each phase, with neutral Bus bar, Earth Bar and Cable ties for cable management, prefitted masking sheet, IP43 IK09 with metal door Warranty on DB is 3 years |
| 273 | Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years |
| 274 | Supplying and fixing 6 32 Amps rating, C series,10KA breaking capacity,SP, 230 volts, MCB . Make LEGRAND DX3/ Siemens Betaguard/ Schneider Acti 9/ABB SB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg. in Charge. The MCB should be Replacement Warranty will be 1 year. |
| 275 | Supplying and fixing 63 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB . Make LEGRAND DX3/ Siemens Betaguard/ Schneider Acti 9/ABB SB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg. in Charge. The MCB should be Replacement Warranty will be 1 year. |
| 276 | Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 2P, 415 volts, RCCB 30mA . Make LEGRAND DX3 / Siemens Betaguard/ Schneider Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg. in Charge. . The RCCB should be Replacement Warranty will be 1 year |
| 277 | Supply ,installation ,testing and commissioning of 5KVA UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer of 1ph in put to 1 ph output,230V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 26AH, 20 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric/APC/ Vertiv/) , as per direction of Engg. in Charge. Warranty period of all accessories and component and system must be 2 years and complete test certificate must be submitted along with ups including component list and SLD. for services building |
| 278 | Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (with charcoal and salt) as required and as per direction of Engineer in charge. |
| 279 | Providing and fixing 6 swg GI wire on surface or in recess for loop earthing as required and as per direction of Engineer in charge.. |
| 280 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg. in Charge. |
| 281 | S/I/T andCommissioning of LT indoor floor mounted CPRI Tested cubical type Main panel made out by 2mm CRCA steel sheet duly derusted and painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg. in Charge. Warrentee period of replacement of panel and accessories must be 1 year and compelete test certificate must be submitted along with panel board including component list. 20X10MM Separate Aluminium Earth bus bar should be installed.All the incomers shall have 40 kA 3P+N type 2 SPD with 63 A 4P MCB, C series, 10 kA..In commer 01 number of 125 Amps MCCB 25 KA , 01 number of 125 Amps 4P onload type Changeover with both source ON/OFF indication (Make Siemens/Schneider/ABB/LEGRAND)Busbar 04 numbers of 125Amps 50kA Aluinuium busbar duly sleeved by color coaded PVC sleeve and supported by suitable size DMC insulator. Out going (ii) 03 nos 63A 4P MCB 10kA,C series , 03 nos 63A DP MCB 10kA,C series, 02 nos 32A DP MCB 10kA,C series LIGHT BDB AC IDU BDB/LIGHT BDB Make LEGRAND DX3 / Siemens Betaguard/ Schneider Acti 9/ABB SB 200Instrument (i) 3 numbers phase indicating lamp for R,Y,B inndication for both the source with 2A SP MCB,C,10KA. ( Make LEGRAND DX3 / Siemens Betaguard/ Schneider Acti 9/ABB SB 200)..(ii) 01 set of 3 ph digital type Voltmeter(Make Siemens/Schneider/ABB/Legrand).(iii)01 set of 3 ph digital type Ammeter(0 200)A(Make Siemens/Schneider/ABB/Legrand) with CTs 63/5A 3 nos class 1 type(Make Siemens/Schneider/ABB/Legrand) |
| 282 | Supplying and fixing 32amps rating,double pole mcb type changeover 240 volts, C series,10KA breaking capacity, of Make LEGRAND/ Siemens/ Schneider/ABB the existing MCB DB complete with connections as per direction of Engg. in Charge. .Warranty on MCB is 1 year. for UPS Outgoing ) |
| 283 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg. in Charge. 3.5core x 50 sq mm |
| 284 | Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg. in Charge. 3.5 core x50 sq mm |
| 285 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg. in charge. |
| 286 | Supply installation of 33kV 3mm thick Class C Rubber Mat as per IS 15652 and complete as per direction of Eng in charge.(Size 10mx1m) |
| 287 | Danger Board. |
| 288 | Supply and fixing of shock treatement charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel room. |
| 289 | Providing and fixing carbon di oxide type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS : 2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make Safex/Supremex/ Ceasefire/Flameklog .4.5 kg capacity |
| 290 | Providing and fixing ABC type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make Safex/Supremex/ Ceasefire/Flameklog.6 kg capacity |
| 291 | SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA 568 C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from 20° to +70°C Cable support Conductor Resistance less than equal to 9.38 ohm/100m Max., Cable support Delay Skew: less than 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 ohm at100 MHz. and Propagation Delay at250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit. |
| 292 | SITC of Cat6 I/O with single Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, and EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 at 250Mhz and CAT6A at 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold greater than 0.8 mu m. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94 V O certified. Make: Systimax, Legrand, Panduit |
| 293 | SITC of Cat 6, 24 port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax, Legrand, Panduit |
| 294 | SITC of Cat6 UTP 23 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA 568 C.2 Standard. Supports Data Networks Speeds Up to 10/100 Base T and 1000 Base T. Available In LSZH Jacket Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50mu Gold Plated Contacts , 100 percent Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(1 mtr length) |
| 295 | SITC of Cat6 UTP 23 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA 568 C.2 Standard. Supports Data Networks Speeds Up to 10/100 Base T and 1000 Base T. Available In LSZH Jacket Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50mu Gold Plated Contacts , 100 percent Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(2 mtr length) |
| 296 | SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173 1:2002 / IEC 60794 1/IEC 60793 2 50 class B1.3 / EN 60793 2 50: class B1.3 / ITU Recommendation G.652.D the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 2002 incl. 802.3ae ) Jacket. Make: Systimax, Legrand, Panduit |
| 297 | SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19 inch ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC, PC Type ,Pigtail, Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR 326 Core . Make: Systimax, Legrand, Panduit |
| 298 | SITC of OFC Patch Cor, SM (OS2), Duplex LC SC, LC LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : less than equal to 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC greater than= 45db, UPC greater than=50db, APC greater than=60db. Make: Systimax, Legrand, Panduit |
| 299 | SITC of 1G LX/LH SFP transceiver module,SMF, 1310nm, 9/125 um Single mode Fiber Type up to 20 KM. Make: Cisco, Digisol, Netgear |
| 300 | SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) and IEEE 802.3at (30W). Total PoE power: 380W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C 50°C ,Power Supply AC: 100 240V. Make: Digisol, Cisco, HP |
| 301 | SITC of 9U/500D Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068 2 11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian Standard 06 Socket Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack, Rittal, Legrand |
| 302 | SITC of 9U/500D Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068 2 11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian Standard 06 Socket Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack, Rittal, Legrand |
| 303 | Supply, Installation, Testing and Commissioning of 5MP IP Network TDN Low Light IR motorized Lens Dome/Bullet Camera, 1/2.8inch CMOS or better, 5MP (2592 x 1944) at 25fps or better, four stream at various resolution and Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 70m(bullet)/50m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 1/100,000; Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG , Fixed Lens 2.7 13.5mm motorized, Field of View FoV H:100 28.5°, V:73 21.4°, BLC, HLC, WDR, 2D/3DNR, White Balance Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, and People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES 128/256, SSH/Telnet closed, Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 and IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range : minus 30°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130 4), FCC Part 15, EN 55032 and RoHS (EN63000),NDA,STQC compliant. Make Honeywell value series/Pelco/Axis/Bosch |
| 304 | Supply , Installation, testing , commissioning of 64 Channel NVR with 8 SATA; 384 Mbps incoming bandwidth, Up to 8 Megapixels Resolution Display and Recording, H.265 video compression technology with real time encoding, Full function CMS (Central monitoring software) supported, Two way audio supported, Dual streaming technology to encode recording stream and network stream separately, Supports remote monitoring on Mobile Client (Android, IOS), TCP / IP, PPPoE, DHCP, DNS, DDNS, UPnP, NTP, SMTP, Time/ Date, Alarm, Motion Detection and Exact Search (accurate to second), Record Snapshot, FTP, Preset Calling, Email notification supported, Manual/ Alarm/ Motion Detection/ Continuous, CE, FCC, RoHS).Make Honeywell value series /Pelco/Axis/Bosch |
| 305 | Supply, Installation,Testing and Commisioning of Surveliance 10 TB HDDMake: WD/Segate/Toshiba |
| 306 | SITC of 55inch UHD IPS Commercial Digital Display for Small Size Discussion and Chambers: Brightness (440 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio 1200:1, Response Time (G to G) 8 ms, Refresh Rate. 60 Hz, Life span (hrs) 30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty. Make: LG/Samsung/Sony |
| 307 | AREA LIGHTING and EXTERNAL CCTV WORK SITC of Street light 120W,130 lm/w efficacy ,IP PC Lens new generation energy saving and environmental friendly long life versatile pressure die cast alluminium IP66, IK 08 roadway luminaire with high power LED as light source with acrylic cover(Make:LT/ /Philips/Wipro/Havells/Crompton/Bajaj/PANASONIC ) (5Years Warranty) |
| 308 | Supply of 8 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel(with decorative single arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 155 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge. |
| 309 | Supply of 8 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel(with decorative DOUBLE arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 155 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge. |
| 310 | Supply of Elegant look 60 W( greater than equal 190lm/W) AIO LED Solar Street lights having extruded alluminium housing, 180Wp or more (subjected to final panel backup calculation with dimming profile of 100 percent output for 2 hrs, 90 percent output for 1 hr, 60 percent output for 1 hr and 50 percent output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R andB) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) Mono Crystalline Panel/Laminates fixed on the top of the luminaire housing, maintenance free 12.8 volts 96 Ah or more (subjected to final battery calculation with dimming profile of 100 percent output for 2 hrs, 90 percent output for 1 hr, 60 percent output for 1 hr and 50 percent output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R andB) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) LiFePO4 battery(BIS certified) , BMS, MPPT charge controller, PIR sensor( when there will be no movement the lumens output will be 30 percent output).The solar panel and battery should be designed to provide 2 days (24 hrs ) back up . The luminaire is having IP 65 protection for critical components, IK 08 and having lumen output of greater than equal to11400 lumens as per LM 79 report third party/central/state govt accredited NABL lab to justify the lumen output and lumen efficacy . Lenses should be provided on the LED chip for better lighting dstribution to avoid glare on human eyes. Both the luminaire and Mono Crystalline Panel must be manufactured in India. The Solar lighting company must submit the third party central/state govt accredited NABL lab reports to justify the lumen efficacy,luminaire output , IK 08 and IP 65 protection.The Luminaire should be supplied along with adjustable type mounting bracket which can be fitted directly on the pole.The Solar lighting manufacturer must submit the declaration letter by mentioning that complete solar light and the solar panel are manufactured in India and warranty certificate on their company s letterhead by mentioning warranty period as 5 years and necessary aftersales Service will be provided through their tollfree base service network located within 100 KM from the project site. The Solar Street light manufacturer should have own NABL accredieted laborotory. The following test reports must be submitted and approved from SE,Electrical Circle (R andB) and CE ,Buildings, Odisha, BBSR for the technical acceptance of the products.1.LM 79 REPORT and LM 80 Report ( from third party/central/state govt accredited NABL lab of AIO solar light) , 2. IK 08 ( from third party/central/state govt accredited NABL lab of AIO solar light ) , 3. IP 65 (Report of third party/central/state govt accredited NABL lab of AIO solar light 4. EN50530 MPPT Efficiency , 5. IEC61547 , 6. IEC61000 3 2 EMC , 7. IEC 60598 2 3 ,8. IEC 62109 1, ( The necessary test reports of third party/central/state govt accredited NABL lab from sl no. 4 to sl no.8 must be submitted for any wattage of AIO solar light )Make (Philips/Panasonict/Wipro/Crompton/Bajaj/Havells/LT ). NB: The cost includes 5 years CMC including repair/ Maintenance/ replacement of the product in case of any defect. |
| 311 | Supply of 8 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 155 MM A/F of 4 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge. |
| 312 | Installation of 60W AIO LED solar street light on 8 mtr octagonal pole. |
| 313 | SITC of high quality integrated LED Flood Light with a minimum system lumen of 26K Lm or higher and nominal efficacy of 130 lumen/watt or higher. CCT of 5700K with SDCM of < 5 and CRI greater than=80. The housing should be of pressure die cast aluminum (ADC12) to with stand extreme environments. The luminaire should come with with PF greater than 0.95, THD less than 10 percent, Lifetime of 50K hours atL70. Product should be suitable for continuous operation (10 12 Hrs. per day). The Ingress protection should be minimum IP 66 with an IK rating of 08. Optical and control gear compartments shall be maintainable/replaceable without impacting the LED units. The access to the optical and the gear compartment should be separate. While accessing the gear compartment, the optical compartment should not be accessible. The Luminaire should have internal surge protection of 4kv and 10 KV /10 KA SPD duly bolted in the Luminaire . The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2.The luminaire should be of Class B Serviceability. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip , array multi die , mid power ,Integrated arrays and COBs are not permitted. The High power LED used in the luminaire shall be SMD type. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown at 325V and have an auto recovery feature. The Drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire. The fixture shall have warranty of 5 years. LM79,LM80,Type test report, BIS certificate of driver and luminaire, TDS of luminaire and driver,LUX level design to be done as per following specifications: average lighting level shall be greater than=500 LUX ,min to average shall be greater than=0.7, min to max shall be greater than=0.5 and shall be approved by SEEC(R andB) and CE,Bdgs,O,BBSR before final procurement.(4 Nos. for Each pole) Only sport series flood light will be accepted.Make Philips/ Lighting Technologies/ Schréder/Equivalent |
| 314 | Supply of 9 mtr long hot dip galvanized Octagonal pole with channel bracket (for mounting at least 6nos. or more of flood light as per final lux level design) manufactured from HT steel having base dia if 210 mm and top dia 90 mm or more and sheet thickness of 4 mm or more and 4 Nos. M30X850mm EN8 Grade foundation bolt. The octagonal pole shall be suitable to withstand 200 KM/HR or more wind speed by considering the weight and wind expose area . All accessories included like anchor plate, foundation nuts and bolts including required size of control cable from starter panel to Each light . Make: Bajaj/RR Ispat/Utkarsh /Valmont /Vakrangee |
| 315 | Construction of pedestal type foundation with M20 grade concrete for pole 2000mm depth x 550mm length x 550mm breadth including all material and labour as per the direction of Engineer in charge. The structural calculation and civil foundation shall be duly approved by the competant authority from civil wing before execution of the work. |
| 316 | STREET LIGHT: S/I/T andCommissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted and pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 63A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 63 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type II SPD 40ka ,,04 nos 16A 4P MCB,C,10KA as outgoing MCB legrand dx3/ schneider acti9 A9N/ Siemens betaguard/ ABB ( SB 200) as per direction of Engg. in Charge. Ncessary test report and Warrnaty certificate to be submitted to the department for genuinity of product and to avail free after sales service within warranty period 1 years of acceptance of materials |
| 317 | OUTDOOR LIGHT PANEL:S/I/T andCommissioning of LT outdoor floor mounted doubledoor CPRI Tested cubical type Main panel made out by 2mm CRCA steel sheet duly derusted and painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg. in Charge. Warrentee period of replacement of panel and accessories must be 1 year and compelete test certificate must be submitted along with panel board including component list. 20X10MM Separate Aluminium Earth bus bar should be installed.All the incomers shall have 40 kA 3P+N type 2 SPD with 63 A 4P MCB, C series, 10 kA.All feeders shall have ON/OFF/TRIP indication.Mandatory provision of Cable alley is to be given.Incomer:63 A 4P MCCB (16 KA) with adjustable thermal setting Ics = 100 percent of Icu Busbar 04 numbers of 300 Amps Aluminium busbar duly sleeved by color coded PVC sleeve and supported by suitable size DMC insulator. OUTGOING : 5 Nos 40A 4P MCB. (10 KA), C series , Instrument (i) 03 numbers phase indicating lamp with toggle switch and HRC fuse.(ii) 01 set of 0 200Amps Ammeter with CTS.(DIGITAL)(Make Legrand/ABB/schneider/Siemens)(iii) 01 set of 0 500 voltmeter .(DIGITAL)(Make Legrand/ABB/schneider/Siemens)MAKE OF MCCB LEGRAND DPX3 / Siemens 3VA Model/ Schneider CVS/ABB FormulaMake of MCBs LEGRAND DPX3/Siemens Betaguard Schneider Acti 9/ABB SB200 |
| 318 | outdoor light sub panel :Design, Supply, Installation, Testing and Commissioning of LT outdoor floor mounted doubledoor type with CRCA 2mm thick Mast Lighting Distribution Boards ( MLDB) for operation of the lights on Stadium masts.Mandatory provision of Cable alley is to be given.incomer 40A, FP MCB, C series,10kA , 100 Amp.aluminum Bus Bar 4 Nos. by color coded PVC sleeve and supported by suitable size DMC insulator and outgoing 6A DP MCB, C series,10kA 10 nos with one no.40kA type 2 3P+N SPD with 63A 4P MCB, C series, 10kA in the incomer and other accessories as per direction of Eng in charge.Make of MCB Make LEGRAND DX3 / Siemens Betaguard/ Schneider Acti 9/ABB SB 200Make of SPD LEGRAND/SIEMENS/SCHNEIDER/ABB/OBO/DEHN |
| 319 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg. in Charge. 3.5 core x 25 sq mm Aluminium armoured Cable.(FOR street PANEL) |
| 320 | 4 core x 10 sqmm A2XFY |
| 321 | Supply and laying of3 core 2.5 sqmm Flexible copper cable (flood light and Street Light) |
| 322 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg. in charge. |
| 323 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required including the cost of material ,labor T and P as required as EIC. |
| 324 | Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required. |
| 325 | SITC of outdoor type double jacketed 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA 568 C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from 20° to +70°C Cable support Conductor Resistance less than equal to 9.38 ohm/100m Max., Cable support Delay Skew: less than 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 ohm at100 MHz. and Propagation Delay at250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit. |
| 326 | SITC of Cat 6, 24 port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax, Legrand, Panduit |
| 327 | SITC of Cat6 UTP 23 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA 568 C.2 Standard. Supports Data Networks Speeds Up to 10/100 Base T and 1000 Base T. Available In LSZH Jacket Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50mu Gold Plated Contacts , 100 percent Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(1 mtr length) |
| 328 | SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173 1:2002 / IEC 60794 1/IEC 60793 2 50 class B1.3 / EN 60793 2 50: class B1.3 / ITU Recommendation G.652.D the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 2002 incl. 802.3ae ) Jacket. Make: Systimax, Legrand, Panduit |
| 329 | SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19 inch ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC, PC Type ,Pigtail, Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR 326 Core . Make: Systimax, Legrand, Panduit |
| 330 | SITC of OFC Patch Cor, SM (OS2), Duplex LC SC, LC LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC greater than= 45db, UPC greater than=50db, APC greater than=60db. Make: Systimax, Legrand, Panduit |
| 331 | SITC of 1G LX/LH SFP transceiver module,SMF, 1310nm, 9/125 um Single mode Fiber Type up to 20 KM. Make: Cisco, Digisol, Netgear |
| 332 | SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) and IEEE 802.3at (30W). Total PoE power: 380W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C 50°C ,Power Supply AC: 100 240V. Make: Digisol, Cisco, HP |
| 333 | SITC of 9U/500D outdoor type IP67 fLOOR Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068 2 11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian Standard 06 Socket Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack, Rittal, Legrand |
| 334 | Supply, Installation, Testing and Commissioning of 5MP IP Network TDN Low Light IR Fixed Lens Dome/Bullet Camera, 1/2.8inch CMOS or better, 5MP (2592 x 1944) at 25fps or better, four stream at various resolution and Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 50m(bullet)/40m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 1/100,000; Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG , Fixed Lens 2.8mm(Dome)/3.6mm(bullet), Field of View FoV H:96.5°, V:73.8°(dome)/ Field of View FoV H:94.1°, V:71°(bullet), BLC, HLC, WDR, 2D/3DNR, White Balance Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, and People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES 128/256, SSH/Telnet closed, Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 and IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range : 30°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130 4), FCC Part 15, EN 55032 and RoHS (EN63000),NDA,STQC compliant. Make Honeywell Value series/Pelco/Axis/Bosch |
| 335 | Supply, Installation, Testing and Commissioning of 5MP IP Network TDN Low Light IR motorized Lens Dome/Bullet Camera, 1/2.8inch CMOS or better, 5MP (2592 x 1944) at 25fps or better, four stream at various resolution and Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 70m(bullet)/50m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 1/100,000; Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG , Fixed Lens 2.7 13.5mm motorized, Field of View FoV H:100 28.5°, V:73 21.4°, BLC, HLC, WDR, 2D/3DNR, White Balance Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, and People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES 128/256, SSH/Telnet closed, Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 and IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range : minus 30°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130 4), FCC Part 15, EN 55032 and RoHS (EN63000),NDA,STQC compliant. Make Honeywell value series/Pelco/Axis/Bosch |
| 336 | Lightning Protection : Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make OBO/Dehn/ABB |
| 337 | Supply of Roof conductor holder for parapet PolyamideConductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from 35 to +90 degree Celsius tested.Conductor holder at 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make OBO/Dehn/ABB |
| 338 | Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost resistant concrete). Sleeve from polyethylene, blackat 1 meter distance. Tested as per IEC 62561. Make OBO/Dehn/ABB |
| 339 | Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make OBO/Dehn/ABB |
| 340 | Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make OBO/Dehn/ABB |
| 341 | Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS IEC 62305 part 3 Nominal size Ø10/16 mm aluminium rod: 3 Mtr Airterminal: semi hard (E AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load.Tested as per IEC 62561. Make OBO/Dehn/ABB |
| 342 | Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make OOBO/Dehn/ABB |
| 343 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make OBO/Dehn/ABB |
| 344 | Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified indrawing and directed by Engineer.Tested for 100kA lightning current. Make OBO/Dehn/ABB |
| 345 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr HeightFor Test Joint .Internal dimensions: 100x100x48 mm Make OBO/Dehn/ABB |
| 346 | Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make OBO/Dehn/ABB |
| 347 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make OBO/Dehn/ABB |
| 348 | Supply of flat conductor holder Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over piece from hot dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make OBO/Dehn/ABB |
| 349 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum coated chemical fibre fabric. Make OBO/Dehn/ABB |
| 350 | Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561 2 Make OBO/Dehn/ABB |
| 351 | Supply of universal clamp made of SS to connect rod with flat conductor Make OBO/Dehn/ABB |
| 352 | Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561 7,TCLP tested Make OBO/Dehn/ABB |
| 353 | Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Make OBO/Dehn/ABB |
| 354 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge. |
| 355 | Supply Installation Testing and Commissioning of on grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono PERC HALF CUT bifacial Crystalline silicon solar cells, net metering facility ,necessary protections, earthing, mounted on hot dip GI structure( solar panel bottom height from roof level shall not be less than 300mm, accordingly GI structure to be designed) of suitable strength with following components a complete as arequired: a) Solar Photovoltaic Module of capacity 545Wp or above, manufactured in India, conforming to IS14286 / IEC61215, IS/IEC61730 Part 1,IS/IEC61730 Part 2. Solar Photovoltaic Module conversion efficiency shall not be less than 22 percent. PV modules used in solar power plants /systems must be warranted for their output peak watt capacity, which should not be less than 90 percent at the end of 10 years and 80 percent at the end of 25 years. b) Power Conditioning Unit (PCU) of 350 800 V DC Input voltage range and 400 V AC, three phase , 4 wire, 50Hz +/ 2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97 percent, total harmonic distortion less than 3 percent and suitable for ambient temperature from 0 to 50 degree Celcious. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage,frequency. c) Data Monitoring System complete with accessories.d)Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugsand other accessories etc. asarequired.e) Lightning and surge voltage protection. f) Connections and Interconnections by supplying and fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying and fixing of necessary channel/ conduit lugs and other accessories etc. asrequired. with all required accessories as required as per the direction of Engg in charge.Make Tata/waree/luminous/adani/panasonic. The entire SOLAR system should be Replacement Warranty will be 5 years |
| 356 | PH WORKS : Providing, laying and jointing in position MS/PVC pipe conforming to ISI standard 4985:2000 and suitable for the respective working pressures with vith all fittings and accessories e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces etc. jointing as per manufacturers instruction, PVC PIPE 110mm at kg/cm2 |
| 357 | Earthwork excavation refilling |
| 358 | SPRINKLERS and ACCESSORIES Supply Installation Testing and Commisioining of ST 1200 BR having Radius: 20.4 m to 35.1 m, Nozzle choices: 12. Nozzle trajectory: 22.5°, Isolated, grease lubricated gear drive, Nozzle barrels: short and long (included), Movable stops (left and right)arc adjustment, Arc setting: 40° to non reversing 360°, Ratcheting nozzle 2.1 turret, Recommended pressure range: 2.0 to 6.0 bar; 200 to 600 kPa, Flow: 6.13 to 29.76 m3/hr: 102.1 to 495.9 l/min |
| 359 | Supply and Installtion of, 2inch QCV Connection Assembly etc. item complete. |
| 360 | Supply and Installtion of PVC/ HDPE service saddle of varying size 2inch item complete. |
| 361 | VALVES and ACCESSORIES Providing and fixing of Isolation Valve in mainline for bypass and flow diversion of 3.1 approved quality 100 MM |
| 362 | Providing and fixing of PVC Ball Valve,security pivot to maintain lever in space, double water tight joint, direct injection stem non mechanical,with a base which permits maximum penetration into the valve of size 63mm. |
| 363 | Providing and fixing of a double acting 1inch Air release valve, The Air release valve shall be capable of both releasing and admitting air from and into the line. The working pressure shall be 5 bar. Including service saddle and riser assembly. |
| 364 | Providing and fixing of 12inch Rectangular Valve Box with greenlid and corrugated structure with unique shovel access slot and bolt hole knockout |
| 365 | Providing and fixing of 6inchRound box with greenlid and corrugated structure with unique shovel access slot and bolt hole knockout |
| 366 | PUMPING UNIT Providing and Fixing of (Monoblock/Openwell submersible) pumpset of having discharge 6 Ipsat 52 mtr head Model no. 1050. suitable for pumpset having panel box and fixed alongwith following accessories starter,start / stop push buttons, Ammeter, Voltmeter, Indicating lamps, MCB, with cable, etc |
| 367 | Cpvc Pipe header assembly as per requirements |
| 368 | 6.4 Providing and fixing of Non Return Valve 4inch to prevent back flow |
| 369 | Providing and fixing of Pressure Release Valve 2inch |
| 370 | B. FACILITY BUILDING(Internal PH and Sanitary work) Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge Ground Floor 20mm dia C PVC pipe |
| 371 | 25mm dia C PVC pipe |
| 372 | 32mm dia C PVC pipe |
| 373 | First Floor 40mm dia C PVC pipe |
| 374 | 50mm dia C PVC pipe |
| 375 | Supplying all materials, labour T andP and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost and conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer in charge.JAQUAR/HINDWARE/CERA OR EQUIVALENT 15mm dia CP angle stop cock(FLR ACR 5053N) |
| 376 | 15mm dia CP two way bib cock(FLR CHR 5041N) |
| 377 | 15mm dia CP Long Body Bib cock (Con CHR 107KN Jaquar make) |
| 378 | 15mm dia CP Pillar cock (Con CHR 011KN Jaquar make) |
| 379 | 25mm dia brass full way valve (Shakti make) |
| 380 | 32mm dia brass full way valve (Shakti make) |
| 381 | 40mm dia brass full way valve (Shakti make) |
| 382 | 50mm dia BFW Valve (Shakti make) |
| 383 | Wall Mixer with provision for Overhead Shower (FLR ABR 5273UPR) |
| 384 | Square Shape Single Flow Maze Overhead Shower Chrome OHS CHR 1605 |
| 385 | Shower Arm Chrome SHA CHR 455L400 |
| 386 | 15mm dia CP Health faucet (Con ALD MCH 573 Jaquar make) |
| 387 | 15mm CP Extension piece |
| 388 | 125mm CP grating |
| 389 | 15mm size C.P. flange |
| 390 | Double Coat Hook AKP CHR 35761P Jaquar |
| 391 | Pressmatic Urinal Valve PRS CHR 077 Jaquar make |
| 392 | Construction of 2x5000 Liters PVC Over head Tank in forth floor with Stagging(10 K) in First Floor Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M 30 (minimum cement content not less than 403 Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance, taxes, loading, unloading, royalties, watering and curing for the required period, T andP , hire and running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer in charge but excluding the cost of steel reinforcement and shuttering. Column 6x0.25x0.25x0.75 |
| 393 | Beam 2x(4.5+2.5)x0.25x0.40 |
| 394 | Base Slab 1x4.50x2.50x0.15 |
| 395 | Supplying all materials, labour, T andP and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage. at 130 kg / cum = |
| 396 | Supplying all materials, labour,T andP and providing Brick Masonary work im cement morter (1:4) using fly ash bricks work including watering curring and conveyance of all materials to site. Total Long wall+ short wall |
| 397 | Supplying all materials, labour,T andP and providing 12mm thick cement plasster (1:4) over BM work including watering curring and conveyance of all materials to site. out side long wall 2x4.50x0.90 |
| 398 | out side Short wall 2x2.50x0.90 |
| 399 | In side long wall 2x4.00x0.90 |
| 400 | In side Short wall 2x2.00x0.90 |
| 401 | Providing fitting and fixing stainless steel ladder including fixing to wall necessary welding etc. complete Providing fitting and fixing MS cover made out of MS angle and sheet duly welding and fixing with frame and hinges along with locking arrangement of size 60cmx60cm etc complete as per direction of Engineer in charge |
| 402 | Supplying all materials,labour,T andP and fixing Rotational moulded three lyer polyethylene cylindrical vertical water storage tanks ( white colour)conforming to IS : 12701 1996 including cutting holes through the tank and fixing mild steel/PVC tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position. conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge 5000litre capacity water storage tanks |
| 403 | supplying all materials, labour, T andP and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost and conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer in charge. Ground Floor |
| 404 | First Floor |
| 405 | Supplying all materials , labour, T andP and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak proof as per P.H. specification and direction of Engineer in charge Ground Floor |
| 406 | Supplying all materials, labour, T andP and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost and conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer in charge. Ground Floor |
| 407 | Supplying all materials, labour, T andP and fitting and fixing U PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non heat application method/as per manufacturer s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost and conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer in charge. 110mm U PVC SWR Pipe (Supreme /Ashirvad) |
| 408 | 110mm U PVC P Trap(Ori Plast/Finolex/Supreme Make) |
| 409 | 110mm U PVC door bend(Ori Plast/Finolex/Supreme Make) |
| 410 | 110mm U PVC Plain bend(Ori Plast/Finolex/Supreme Make) |
| 411 | 110mm U PVC offset without ear(Ori Plast/Finolex/Supreme Make) |
| 412 | 110mm U PVC Cowl(Ori Plast/Finolex/Supreme Make) |
| 413 | 110mm U PVC S/Jn door(Ori Plast/Finolex/Supreme Make) |
| 414 | 110mm U PVC Plain tee(Ori Plast/Finolex/Supreme Make) |
| 415 | 110mm U PVC D/Jn door(Ori Plast/Finolex/Supreme Make) |
| 416 | 110mm U PVC Door tee(Ori Plast/Finolex/Supreme Make) |
| 417 | 110mm U PVC Socket(Ori Plast/Finolex/Supreme Make) |
| 418 | Supplying all materials,labour,T andP and fixing Flat back lipped wall urinal of the following sizes including connecting the urinal with 32mm. dia pvc waste pipe 910mm. long by means of white lead mixed with chopped hemp, fixing 32mm. dia CP dome waste, 15mm. dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc. all complete as per specification and direction of the Engineer in charge Flat Back Large Urinal (Hindware make 60002) |
| 419 | 15mm dia urinal spreader |
| 420 | 32mm CP doom waste |
| 421 | Supplying all materials, labour, T andP and fitting and fixing of toilet front partition size 0.9x0.5 with door made 12mm thick solid compact laminated (Phenolic core board) reinforced with celluse fibres, the partision fixed in wall hanging with clamps complete etc as per specification and direction of the Engineer in charge.Urinal Partition wall |
| 422 | Supplying all materials, labour, T andP and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI p or s trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost and conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer in charge. 580mm size Orissa pan (Hindware/Parryware/Neycer make) |
| 423 | Supplying all materials, labour T andP and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost and conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer in charge10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline white Parryware make ) 10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline white Parryware make ) |
| 424 | Supplying all materials, labour, T andP and fixing the following vitreous china Wash Down Water Closet(European type W.C. pan)with integral p or s trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing , cost and conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer in charge One piece commod(Hindware make)ELEMENT Cat No.92084. |
| 425 | Supplying all materials, labour T andP and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered Hot and Cold with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost and conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer in charge Under Counter basin(560x450)Hindware No.10095 |
| 426 | Supplying all materials, labour, T andP for fitting and fixing plain edge kitchen/wall sink of all standard sizes with a pair of bracket, C.P. waste, trap and P.V.C. waste pipe and painting brackets including supply of cement concrete and mortar etc. all complete. 24 x 18 x 10 inch sink |
| 427 | Supplying all materials, labour, T andP and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge 25mmx600mm long CP towel rail |
| 428 | Towel ring |
| 429 | Supplying all materials, labour, T andP and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge. Large Size mirror with Frame (.9 x.9 x 8) |
| 430 | Supplying all materials, labour, T andP and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge CP Soap dish Holder (ACN CHR 1131N) Jaquar Make |
| 431 | SOAP DISPENSER WITH GLASS BOTTLE ACN ABR 1135N |
| 432 | Supplying all materials ,labour ,T andP and constructing gully trap chamber of inside size 250mmx250mm with 8cm thick RCC precast cover slab in cement concrete (1:2:4) mix using 12mm size crusher broken HG chips, foundation concrete (1:4:8) using 40mm size crusher broken HG metal on bed and around trap, KB brick work in cement mortar (1:6) in foundation and plinth and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap, 150mmX150mm size CI grating etc.all complete as per drawing, specification and direction of Engineer in charge |
| 433 | Supplying all materials, labour, T andP and providing fitting and fixing (Aqua guard) pure chill 80 PSS UV of size 750 x 570 x 1350mm hight with water storage capacity 80 liter s along with 2 noa of faucets 1 for cold water and 1 for normal water including a flow of 1.5 ltr per munite etc all complete as per approved drawing , specification and direction of the Engineer in charge Aqua guard 7ltrs |
| 434 | Aqua guard pure Chill 120 PSS UV |
| 435 | D. Gate Complex( Internal PH and Sanitary Work) Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge Ground Floor 25mm dia C PVC pipe |
| 436 | 32mm dia C PVC pipe |
| 437 | First Floor 40mm dia C PVC pipe |
| 438 | Supplying all materials, labour T andP and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost and conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer in charge.JAQUAR/HINDWARE/CERA OR EQUIVALENT 15mm dia CP angle stop cock(FLR ACR 5053N) |
| 439 | 15mm dia CP two way bib cock(FLR CHR 5041N) |
| 440 | 15mm dia CP Long Body Bib cock (Con CHR 107KN Jaquar make) |
| 441 | 15mm dia CP Pillar cock (Con CHR 011KN Jaquar make) |
| 442 | 25mm dia brass full way valve (Shakti make) |
| 443 | 32mm dia brass full way valve (Shakti make) |
| 444 | 40mm dia brass full way valve (Shakti make) |
| 445 | 15mm dia CP Health faucet (Con ALD MCH 573 Jaquar make) |
| 446 | 15mm CP Extension piece |
| 447 | 125mm CP grating |
| 448 | 15mm size C.P. flange |
| 449 | Pressmatic Urinal Valve PRS CHR 077 Jaquar make |
| 450 | Supplying all materials , labour, T andP and fixing rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr width KB brickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxes etc.all complete as per approved drawing , P.H. specification and direction of Engineer in charge 1000 liters capacity PVC water storage tank roof of 1st floor |
| 451 | supplying all materials, labour, T andP and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost and conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer in charge. Ground Floor |
| 452 | First Floor |
| 453 | Supplying all materials , labour, T andP and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak proof as per P.H. specification and direction of Engineer in charge Ground Floor |
| 454 | Supplying all materials, labour, T andP and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost and conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer in charge. Ground Floor |
| 455 | Supplying all materials, labour, T andP and fitting and fixing U PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non heat application method/as per manufacturer s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost and conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer in charge. 110mm U PVC SWR Pipe (Supreme /Ashirvad) |
| 456 | 110mm U PVC P Trap(Ori Plast/Finolex/Supreme Make) |
| 457 | 110mm U PVC door bend(Ori Plast/Finolex/Supreme Make) |
| 458 | 110mm U PVC Plain bend(Ori Plast/Finolex/Supreme Make) |
| 459 | 110mm U PVC offset without ear(Ori Plast/Finolex/Supreme Make) |
| 460 | 110mm U PVC Cowl(Ori Plast/Finolex/Supreme Make) |
| 461 | 110mm U PVC S/Jn door(Ori Plast/Finolex/Supreme Make) |
| 462 | 110mm U PVC Plain tee(Ori Plast/Finolex/Supreme Make) |
| 463 | 110mm U PVC D/Jn door(Ori Plast/Finolex/Supreme Make) |
| 464 | 110mm U PVC Door tee(Ori Plast/Finolex/Supreme Make) |
| 465 | 110mm U PVC Socket(Ori Plast/Finolex/Supreme Make) |
| 466 | Supplying all materials,labour,T andP and fixing Flat back lipped wall urinal of the following sizes including connecting the urinal with 32mm. dia pvc waste pipe 910mm. long by means of white lead mixed with chopped hemp, fixing 32mm. dia CP dome waste, 15mm. dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc. all complete as per specification and direction of the Engineer in charge Flat Back Large Urinal (Hindware 60002) |
| 467 | 15mm dia urinal spreader |
| 468 | 32mm CP doom waste |
| 469 | Supplying all materials, labour, T andP and fixing the following vitreous china Wash Down Water Closet(European type W.C. pan)with integral p or s trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing , cost and conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer in charge European water closet with P trap plain |
| 470 | 10 litres capacity PVC LL cistern (Slimline Deluxe colour Parryware make) |
| 471 | Supplying all materials, labour T andP and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered Hot and Cold with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost and conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer in charge 625mmx400mm size wash hand basin |
| 472 | Supplying all materials, labour, T andP and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge 25mmx600mm long CP towel rail |
| 473 | Towel ring |
| 474 | Supplying all materials, labour, T andP and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge. 600mmx450mm size B.E mirror (swivelled type) |
| 475 | Supplying all materials, labour, T andP and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge CP Soap dish Holder (ACN CHR 1131N) |
| 476 | Supplying all materials ,labour ,T andP and constructing gully trap chamber of inside size 250mmx250mm with 8cm thick RCC precast cover slab in cement concrete (1:2:4) mix using 12mm size crusher broken HG chips, foundation concrete (1:4:8) using 40mm size crusher broken HG metal on bed and around trap, KB brick work in cement mortar (1:6) in foundation and plinth and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap, 150mmX150mm size CI grating etc.all complete as per drawing, specification and direction of Engineer in charge |
| 477 | Supplying all materials,labour,T andP and fixing Standing urinal of the following sizes including connecting the urinal with 32mm. dia pvc waste pipe 910mm. long by means of white lead mixed with chopped hemp, fixing 32mm. dia CP dome waste, 15mm. dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc. all complete as per specification and direction of the Engineer in charge. |
| 478 | i. Water Supplying including of Borewell and Recharge pit Supplying all materials, labour, T andP and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class 3 (0.60mpa ) including jointing with supply of approved solvent cement by non heat application method/as per manufacture s specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C 1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge 160mm dia P.V.C. pipe |
| 479 | RAIN WATER HARVESTING SYSTEM(PIT)(4 nos) 110mm U PVC SWR Pipe (Supreme /Ashirvad) |
| 480 | Supplying all materials labor T andP and constructing MH chamber of sizes earth work in excavation in all kinds of soil CC(1:1:8) with black granite chips size 46mm brick work with K.B. brick having crossing strength not less than 75 Kg /CM2 to 90 Kg/CM2s in CM(1:6)12mm C.P(1:8) inside MH chamber over benching with cement slush pointing (1:3)outside the MH chamber providing painting MS or CI step iron RCC(roof of slab with CC(1:2:4)with black granite chips size 12mm bending binding tying the grills placing of the reinforcement providing RCC color of required size refilling the cavity around the MH chamber with excavated earth including channeling the bed of MH etc all complete as per PH specification. MH size 0.91m x 0.91 m |
| 481 | 450x450mm Square Man Hole Cover 50.0 kg |
| 482 | Earth work in hard soil or gravelly soil within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer in Charge. |
| 483 | Supplying all materials, labour, T andP and providing cement concrete (1:4:8) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 484 | Supplying all materials, labour, T andP and providing brick work with Fly ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:6) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 485 | Supplying all materials, labour, T andP and providing 12mm thick cement plaster (1:4) on brickwork with cement punning and bitumen painting over top of wall including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 486 | Supplying all materials, labour, T andP and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 487 | Supplying all materials, labour, T andP and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge R.C.C floor and roof slabs, landings, balconies, projecting sunshades and |
| 488 | Supplying all materials, labour, T andP and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor |
| 489 | Supplying all materials, labour, T andP and providing cement concrete (1:1½:3)with 12mm size hard broken granite chips including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floorSlab |
| 490 | providing and filling filter media 40mm Boulder |
| 491 | 20mm washed gravel |
| 492 | Course sand |
| 493 | Providing fitting and fixing M.S.grill cover over the harvesty pindi |
| 494 | Sinking of tube well(200) for PIT Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only Drilling of 200mm dia bore 00 mtr to 25mtr |
| 495 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. 200mm dia PVC pipe |
| 496 | cost of 200mm pvc pipe |
| 497 | Cutting slot in casing pipe for recharge of rain water |
| 498 | labour for packing gravel outside the tube well |
| 499 | Cost of washed gravel |
| 500 | Construction of 5nos production wells including scientific source finding through consolidated and unconsolidated rock with down the hammer drilling rig or combination rig with PVC pipe and installation of submersible pump set with all acessories Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only Drilling of 200mm dia bore 00 mtr to 30mtr |
| 501 | 30 mtr to 45mtr |
| 502 | Drilling of 150mm dia bore 45 mtr to 205.00mtr |
| 503 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. Lowering of 200mm dia P.V.C casing pipes 00 mtr to 30 mtrs |
| 504 | 30 mtr to 60mtr |
| 505 | Supplying polyvinyl chloride pipes as per ASTM D 1785 89 having threads in accordance with DIN 2999 part 1/DIN 42225 part II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber O ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of Each pipe length. 200mm dia PVC (sch 80) pipe |
| 506 | Supplying all materials, labour, T andP and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied directly by the department) |
| 507 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge By DTH Rig |
| 508 | Supplying all materials, equipment, labour and conducting reconnaissance survey, integrated Hydrological and Geophysical (Electrical Resistivity Method) survey and selection of potential source for exploration of Ground Water including selection and recommendation of site for drilling wells in selected locations in any part of Orissa under the following Geological formation: Rocky terrain with boulder formation for 300m depth |
| 509 | Supplying all materials, labour, T andP and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge (Texmo/Crompton Greaves/Kirloskar make) 2HP single phase 3 stage vertical / horizontal submersible pump set at head range 20 to 35 meters discharge 145 to 110 LPM with outlet dia of 25mm |
| 510 | DOL Control panel |
| 511 | 40mm dia steel short piece |
| 512 | Well cap |
| 513 | 50mm size CI bracket |
| 514 | 2.50sqmm flat cable |
| 515 | 20mm dia rigid UPVC pipes |
| 516 | Steel rope with cover |
| 517 | Labour charges for lowering including transportation |
| 518 | Supplying all materials, labour, T andP and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge 32mm HDPE pipes (Finolex/Supreme make) |
| 519 | Construction of Production well Protection ChamberSupplying all materials, labour, T and P and constructing Bore well protection chamber of the inside size 650x650x1000 hight with earthwork in excavation in all kind of soil, cement concrete (1:3:6) using 40mm size hard granite metal on foundation, 1st class Fly ash brickwork in cement mortar (1:3), with base cement concrete (1:2:4) using 12mm size h.g. chips, 12mm thick cement plaster (1:4) inside and outside, RCC cover slab in (1:1.5:3) using 12 mm size h.g. chips, and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction pof the engineer in charge. |
| 520 | Construction of 50,000 ltrs. RCC UGR water storage sump 1no. Earth work in stoney earth and gravels mixed with stone and boulder not exceeding 0.014 Cum in volume within 50m initiallead and 1.5 m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per specification approved by the Department. 1x6.40x4.40x1.50 = |
| 521 | Additional depth of 1.50 m over the initial lead and lift 1x6.40x4.40x0.20 = |
| 522 | Excavation of foundation in laterite rock or any hard rock (other than granite or disintegrated rock) removed by chiselling including dressing and levelling the bed not exceeding 1.50 mtr. in depth and depositing the soil within initial lead of 50 mtr. and as per specification approved by the Department. 1x6.40x4.40x0.15 = |
| 523 | Supplying all materials, labour, T andP and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge. 1x6.40x4.40x0.10 = |
| 524 | Supplying all materials, labour, T andP and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge 1x6.40x4.40x0.10 = |
| 525 | Supplying all materials, labour, T andP and providing cement concrete (1:1½:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge 1x5.40x3.40x0.20 = |
| 526 | 2x5.40x0.20x2.00 = |
| 527 | 2x3.00x0.20x2.00 = |
| 528 | 1x5.40x3.40x0.125 = |
| 529 | 2x3.00x0.20x0.20 = |
| 530 | Supplying all materials, labour, T andP and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 531 | Supplying all materials, labour, T andP and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge 2x(5.40+3.40)x2.20 = |
| 532 | 2x(5.00+3.00)x2.20 = |
| 533 | 1x5.00x3.00 = |
| 534 | 1x16.00x0.15 = |
| 535 | Supplying all materials, labour, T andP and providing 12mm thick cement plaster (1:4) to RCC surfaces finished smooth including closed deep chipping and slurry tratment including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. 2x(5.40+3.40)x2.20 = |
| 536 | 2x(5.00+3.00)x2.20 = |
| 537 | 1x5.00x3.00 = |
| 538 | 2x3.00x0.60 = |
| 539 | Supplying all materials, labour, T andP and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. |
| 540 | Supplying all materials, labour, T andP and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor (inside/outside) |
| 541 | Providing and laying Sika top seal 109 hi over roof top slab and parapet, toilet inside after cleaning of surface and applied with a coat of Sika 109 hi primer as per approved specification. The Sika shall be laid between two coats of water proofing membrance and the entire application cover with Sika top seak hi curing,compound of all materials and cost of labour T andP etc.complete as per the direction of the Engineer in charge. In ground floor (inside/outside) |
| 542 | Supplying all materials, labour, T andP and fitting and fixing RCPC Cover all complete as per specification and direction of the Engineer in charge RCPC Cover (24 inch dia) |
| 543 | Supplying all materials,labour T andP and fitting and fixing of Stainless steel Ladder (Length of Ladder 15 feet) etc. all complete as per direction of the Engineer in charge. 2nos at 40kg = |
| 544 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
| 545 | ii. Swerage Line of septic tank and soakpit Ext. S/D Portion Supplying all materials, labour, T andP and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class 3 (0.60mpa ) including jointing with supply of approved solvent cement by non heat application method/as per manufacture s specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C 1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge 100mm dia P.V.C. pipe |
| 546 | 150mm dia P.V.C. pipe |
| 547 | Supplying all materials labor T andP and constructing MH chamber of sizes earth work in excavation in all kinds of soil CC(1:1:8) with black granite chips size 46mm brick work with K.B. brick having crossing strength not less than 75 Kg /CM2 to 90 Kg/CM2s in CM(1:6)12mm C.P(1:8) inside MH chamber over benching with cement slush pointing (1:3)outside the MH chamber providing painting MS or CI step iron RCC(roof of slab with CC(1:2:4)with black granite chips size 12mm bending binding tying the grills placing of the reinforcement providing RCC color of required size refilling the cavity around the MH chamber with excavated earth including channeling the bed of MH etc all complete as per PH specification. MH size 0.91m x 0.91 m |
| 548 | 450x450mm Square Man Hole Cover 50.0 kg |
| 549 | Supplying all materials labour T andP and constructing 1.40m dia x 2.00 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site. |
| 550 | Construction 1 nos 20 users RCC Septic tank Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer in Charge. 1x3.00mx1.80x1.50m= |
| 551 | do with addl. Depth of 1.5 m 1x3.00mx1.80x0.0.30m= |
| 552 | Excavation of foundation in laterite rock or any hard rock (other than granite or disintegrated rock) removed by chiselling including dressing and levelling the bed not exceeding 1.50 mtr. in depth and depositing the soil within initial lead of 50 mtr. and as per specification approved by the Department. 1x3.00x1.80x0.70= |
| 553 | Supplying all materials,labour ,T andP and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer in charge In ground floor 1x3.00mx1.80x0.15m= |
| 554 | Supplying all materials, labour, T andP and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer in charge. In ground floor 1x3.00mx1.80x0.15m= |
| 555 | Supplying all materials, labour, T andP and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge Base 1x2.80x1.60x0.20= |
| 556 | wall 1x2(2.70+1.10)x0.20x2.10= |
| 557 | Top slab 1x2.70x1.50x0.10= |
| 558 | Supplying all materials, labour, T andP and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge Roof Slab 1 x 2.30x1.10= |
| 559 | Slab side 2 x (2.70+1.50) x0.10= |
| 560 | Base 1 x 2x(2.80+1.60)x0.20= |
| 561 | For RCC wall Inside 1x2x(2.30+1.10)x2.10 |
| 562 | Out Side 1x2x(2.70+1.50)x2.10 |
| 563 | Supplying all materials, labour, T andP and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor |
| 564 | Supplying all materials,labour,T andP and providing 12mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer in charge. Floor 1 x 2.3x1.10= |
| 565 | I/s Wall 1x2(2.30+1.10)x2.10 |
| 566 | Out side 1x2 x (2.70+1.50)0.20 |
| 567 | Supplying all materials, labour, T andP and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. |
| 568 | Supplying all materials, labour, T andP and fitting and fixing S.W.Tee of size 160mx160mx160m as per P.H.D.specification and direction of the E.I.C. |
| 569 | Supplying all materials, labour, T andP and constructing vent base as per P.H.D specification etc all complete. |
| 570 | Supplying all materials, labour, T andP and fitting and fixing UPVC SWR soil waste ventilating pipes and fittings to walls with nails, bobbins and wooden plugs or laying in trenches including earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. 110mm diameter U PVC SWR pipe |
| 571 | 110mm dia U PVC Plain shoe bend |
| 572 | 110mm dia U PVC Cowl |
| 573 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge 1 x2 x(3.00+1.50) x 0.15 x 2.00 |
| 574 | Construction 4 nos 30 users RCC Septic tank Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer in Charge. 1x4.10mx1.93 x1.50m= |
| 575 | do with addl. Depth of 1.5 m 1x4.10mx1.93x0.0.60m= |
| 576 | Supplying all materials,labour ,T andP and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer in charge In ground floor 1x4.10mx1.93x0.10m= |
| 577 | Supplying all materials, labour, T andP and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer in charge. In ground floor 1x4.10mx1.93x0.10m= |
| 578 | Supplying all materials, labour, T andP and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge Base 1x3.90mx1.73mx0.20m= |
| 579 | wall 1x2(3.8+1.13)0.20x2.10= |
| 580 | Top slab 1x3.8x1.63x0.10= |
| 581 | Supplying all materials, labour, T andP and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge For Roof slab 1 x 3.3mx1.13m= |
| 582 | 1 x 2(3.8m+1.63m)0.15m= |
| 583 | For RCC wall Inside 1x2(3.3+1.13)x2.10 |
| 584 | Out Side 1x2(3.8+1.63)x2.10 |
| 585 | Supplying all materials, labour, T andP and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor |
| 586 | Supplying all materials,labour,T andP and providing 12mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer in charge. 1 x 3.30mx1.13m= |
| 587 | 1x 2x(3.3+1.13)x2.10= |
| 588 | Out side 1 x (3.8+1.63)0.40 |
| 589 | Supplying all materials, labour, T andP and providing,fitting and fixing 100mm x 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge 110mm dia UPVC Tee |
| 590 | Supplying all materials, labour, T andP and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. |
| 591 | Supplying all materials, labour,T andP and providing Vent base in cement concrete(1:2:4) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 592 | Supplying all materials, labour, T andP and fitting and fixing UPVC SWR soil waste ventilating pipes and fittings to walls with nails, bobbins and wooden plugs or laying in trenches including earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. 110mm diameter U PVC SWR pipe |
| 593 | 110mm dia U PVC Plain shoe bend |
| 594 | 110mm dia U PVC Cowl |
| 595 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge 1 x2 x(4.10+1.63) x 0.15 x 2.00 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayAug 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender