Tender For Servicing And Repairing Of Window/ Split Ac/Tower Type Ac Units In Rlu/ Rsu Exchanges/ Bts Sites Under Bsnl Jind Oa. (Ch. To:- repair maintenace Of Ems Under Rohtak Ba)
Tender Value
6.96 Lakhs
Estimated cost
Bid Submission
05 Aug 2026
11 days left
EMD
13927
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jind → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Servicing And Repairing Of Window/ Split Ac/Tower Type Ac Units In Rlu/ Rsu Exchanges/ Bts Sites Under Bsnl Jind Oa. (Ch. To:- repair maintenace Of Ems Under Rohtak Ba)
BOQ
| Sl. No. | Item Description |
| 1 | Servicing of following capacity Split AC units of various sites i/c cleaning the air filters, washing the condensing units with chemical wash, cleaning the complete units i.e indoor and outdoor unit with the help of blower/pressure etc. greasing of movable parts , removing the minor fault i/c replacement of burnt thimbles, flexible connecting wires etc. if any testing etc complete as reqd |
| 2 | 1.5/2.0 TR Split/3.5TR Tower Type AC Unit |
| 3 | Supplying and charging refrigerant gas R-22/ R407/ R410 in the following capacity split Air conditioner after pressure testing vaccumsing testing connection etc complete as reqd |
| 4 | 1.5 TR Split A.C. Unit |
| 5 | 2.0 TR Split A.C. Unit |
| 6 | 3.5TR Tower Type AC Unit |
| 7 | Supplying and top up of referigerent gas R-22 in 1.5/2.0 TR SAC unit (at site) upto standard value as required |
| 8 | Replacement of following defective components of 1.5/2.0TR Spilt type AC unit i/c dismantling the defective/ burnt ones, fixing and making connections with new ones etc. at different sites as required |
| 9 | Running capacitor - 45-50mfd |
| 10 | Fan blade |
| 11 | Indoor blower motor -1.5TR |
| 12 | Indoor blower motor - 2.0TR |
| 13 | Condensor motor -1.5TR |
| 14 | Condensor motor -2.0TR |
| 15 | Indoor/Outdoor motor for Tower type -3.5TR AC unit |
| 16 | Compressor Rotary type-compatible with SAC Model-1.5TR |
| 17 | Compressor Rotary type-compatible with SAC Model-2.0TR |
| 18 | Compressor for Tower Type AC - 3.5TR |
| 19 | Contactor 3Phase 16A for Tower type AC unit |
| 20 | Single Phase Preventor SPP for Tower type AC unit |
| 21 | Control card Rep. of Tower Type AC - 3.5TR AC unit |
| 22 | Repairing of PCB of 1.5/2TR SAC unit i/c dismentling the same from site taking it to workshop for repairing ,complete checking the circuitry, replacement of defective/faulty electronic components viz, IC etc. and again refixing the same in SAC unit at site making connections testing etc. as required. |
| 23 | Dismantling & shifting the existing 1.5/2.0 TR Split type AC unit (Indoor and Outdoor unit at same site ) i/c cutting the refrigerant pipe and disconnected the electrical connection etc. complete a reqd. |
| 24 | ITC of 1.5 / 2 TR split AC units with complete indoor outdoor units i/c making piping of all types, connection and testing etc complete as required. |
| 25 | S/F extra refrigerant copper piping required for installation of AC units of size 3/8\\"or 1/4\\" and 5/8\\" or 1/2\\") etc. complete as reqd. |
| 26 | P/F of tubular insulation on the existing suction/ discharge line of the AC unit etc complete as required. |
| 27 | Supplying & laying of following sizes PVC Insulated copper conductor power cable of following size i/c laying, fixing , connection etc. complete as reqd .(unarmoured) |
| 28 | 3x1.5 Sqmm |
| 29 | 3x2.5 Sqmm |
| 30 | Replacement of damaged 25mm dia. Medium class PVC drain pipe in surface/recess i/c all accessories for split type AC unit i/c minor civil work making good the damages etc complete as required. |
| 31 | Checking, tracing out and removing the faults of window/ Split AC Units in TE/ BTS sites for the precribed area under the name of work i/c replacement of burnt/ faulty pieces of wires/ cables/ contacts etc and making good the damages etc complete as required. [Note: the area of scope of work will be as stated in the name of work, however in any abonormal circumstatnces, the work will have to be carried out for the area of BA unit & nothing extra will be paid on account of this. Note- distance will be measured from SDE [E] HQ] |
| 32 | Upto 25KM Distance |
| 33 | 25Km - 50KM distance |
| 34 | 51 Km and above distance |
| 35 | Less for dismantled material other than compressor |
| 36 | Less for faulty compresser 1.5 TR. |
| 37 | Less for faulty compresser 2.0 TR. |
| 38 | Less for faulty compresser 3.5 TR Tower type AC. |
| 39 | (NOTE: THE FIRM HAS TO PROVIDE A TRAINED AC MECHANIC/ ELECTRICIAN ALONGWITH MOBILE NO. & NECESSARY SPARE PARTS IN THE PRESCRIBED WORKING AREA SO THAT THE COMPLAINT MUST BE ATTENDED WITHIN 24 HOURS) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysAug 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender