Tender For Repair/Maint Of Dg Sets, Amf Panels, Control Cables And Connected Items At Various Location And Repair/Maint Of Lt Distripution System, Apfc, Service Connections And Other Allied Workks In Domestic And Technical Area At Air Force Station J
Tender Overview
Project Description
Tender for Repair/Maint Of Dg Sets, Amf Panels, Control Cables And Connected Items At Various Location And Repair/Maint Of Lt Distripution System, Apfc, Service Connections And Other Allied Workks In Domestic And Technical Area At Air Force Station Jaisalmer
BOQ
| Sl. No. | Item Description |
| 1 | M&L for maintenance and servicing of DG Set of capacity 7.5 KVA to 75 KVA complete including draining out of diesel from tank, cleaning the tank thoroughly and refilling the drained out diesel, draining out engine oil from the chamber, cleaning the chamber thoroughly and refilling the same with new engine oil to required level, replacing the fuel filter, lubricating oil filter, check & clean air cleaner, change air cleaner elements, check coolant level & make up the same, drain the Fuel filter & water separator, filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the unserviceable brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, changing of V-belts, changing rubber hoses and clips of air cleaner, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories etc complete all as specified and directed. Note : - Spare parts required for this item shall be measured and paid separately. |
| 2 | M&L for maintenance and servicing of DG Set of capacity 80 KVA to 160 KVA complete including draining out of diesel from tank, cleaning the tank thoroughly and refilling the drained out diesel, draining out engine oil from the chamber, cleaning the chamber thoroughly and refilling the same with new engine oil to required level, replacing the fuel filter, lubricating oil filter, check & clean air cleaner, change air cleaner elements, check coolant level & make up the same, drain the Fuel filter & water separator, filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the unserviceable brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, changing of V-belts, changing hoses and clips of air cleaner, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories etc complete all as specified and directed. Note : - Spare parts required for this item shall be measured and paid separately. |
| 3 | M&L for maintenance and servicing of DG Set of capacity 200 KVA to 250 KVA complete including draining out of diesel from tank, cleaning the tank thoroughly and refilling the drained out diesel, draining out engine oil from the chamber, cleaning the chamber thoroughly and refilling the same with new engine oil to required level, replacing the fuel filter, lubricating oil filter, check & clean air cleaner, change air cleaner elements, check coolant level & make up the same, drain the Fuel filter & water separator, filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the unserviceable brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, changing of V-belts, changing hoses and clips of air cleaner, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories etc complete all as specified and directed. Note : - Spare parts required for this item shall be measured and paid separately. |
| 4 | M&L for maintenance and servicing of DG Set of capacity 320 KVA to 500 KVA complete including draining out of diesel from tank, cleaning the tank thoroughly and refilling the drained out diesel, draining out engine oil from the chamber, cleaning the chamber thoroughly and refilling the same with new engine oil to required level, replacing the fuel filter, lubricating oil filter, check & clean air cleaner, change air cleaner elements, check coolant level & make up the same, drain the Fuel filter & water separator, filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the unserviceable brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, changing of V-belts, changing hoses and clips of air cleaner, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories etc complete all as specified and directed. Note : - Spare parts required for this item shall be measured and paid separately. |
| 5 | M&L for maintenance and servicing of DG Set of capacity 750 KVA to 1010 KVA complete including draining out of diesel from tank, cleaning the tank thoroughly and refilling the drained out diesel, draining out engine oil from the chamber, cleaning the chamber thoroughly and refilling the same with new engine oil to required level, replacing the fuel filter, lubricating oil filter, check & clean air cleaner, change air cleaner elements, check coolant level & make up the same, drain the Fuel filter & water separator, filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the unserviceable brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, changing of V-belts, changing hoses and clips of air cleaner, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories etc complete all as specified and directed. Note : - Spare parts required for this item shall be measured and paid separately. |
| 6 | Supply only in repair Control Safety (Water) from 7.5 KVA to 1010 KVA DG set as spare parts for item No 1 to 5 |
| 7 | All as per item No 6.00 here in before but Control Safety (Lub Oil) |
| 8 | All as per item No 6.00 here in before but Gauge Water Temp (54') |
| 9 | All as per item No 6.00 here in before but Gauge Low Temp (96') |
| 10 | All as per item No 6.00 here in before but Gauge Lub Oil Pressure |
| 11 | All as per item No 6.00 here in before but Techohourmeter |
| 12 | Supply and fix in repalacement of battery,12 V 180 AH, 25 plates including testing for its proper functioning as specified and directed by Engr-in-Charge. Note :- Battery shall be original make accepted No substitute of battery. |
| 13 | Supply and fix in repalacement of battery,12 V 150 AH, 25 plates including testing for its proper functioning as specified and directed by Engr-in-Charge. Note :- Battery shall be original make accepted No substitute of battery. |
| 14 | Supply and fix in repalacement of battery,12 V 80 AH, 25 plates including testing for its proper functioning as specified and directed by Engr-in-Charge.Note :- Battery shall be original make accepted No substitute of battery. |
| 15 | Supply and filling in sump / topping up engine oil, multi grade 20w / 40 in engine or relpacement of engine oil complete all as specified and directed by Engineer-in-Charge.Make :- Indian oil / Hindusthan petrolium / Castrol / Pried /Servo or equivalent as approved by GE |
| 16 | S& F in repair Battery link lead made out with 25sqmm copper conductor PVC insulated with Bty terminal of +/- terminal 0.3 mtr long complete all as specified and directed. |
| 17 | S& F in repair Battery link lead made out with 25sqmm copper conductor PVC insulated with Bty terminal of +/- terminal 1.50mtr long complete all as specified and directed. |
| 18 | Supply and fix in repalcement of AVR card suitable for 7.5 KVA to 75 KVA DG Set as per existing complete all as specified and directed. |
| 19 | Supply and fix in repacement of AVR card suitable for 83 KVA to 160 KVA DG Set as per existing complete all as specified and directed. |
| 20 | Supply and fix in repalcement of AVR card suitable for 200 KVA to 320 DG Set as per existing complete all as specified and directed. |
| 21 | S&F in repair Premixed Coolent(35 Ltr), container complete all as specified and directed. |
| 22 | S&F in repair distilled water best quality suitable for lead acid battery, complete all as specified and directed by Engineer-in-Charge. |
| 23 | S&F in repair controller suitable for 60 KVA to 83 KVA DG set, slilent type as per existing complete all as specified and directed. |
| 24 | S&F in repair controller suitable for 250 KVA to 500 KVA DG set, slilent type as per existing complete all as specified and directed. |
| 25 | M&L for servicing, calibration and testing of injector assembly including replacement of worn out parts, barrel, plunger, nozzel, dilivery valve, cup injector and commissioning the same of cap 63 KVA to 250 KVA DG set complete all as specified and directed by Engr-in-Charge. |
| 26 | Dismantling of UNSV self starter of cpacity 12/24 volts from engine and shifting to civil workshop for repair/overhauling of the self starter by rewinding of one field coil, repair and rewinding of armature and fixing it to the existing place after repairing, complete all as specified and directed by Engr-in-Charge. |
| 27 | Supply and fixing in repair contactor 3 pole 32-55 Amps, 415 Volts, conforms to IS/IEC 60947-4-1 & IEC 60947-4-1 in and including providing auxilary conactors NO/NC complete all as specified and directed by Engr-in-Charge |
| 28 | Supply and fixing in repair contactor 3 pole 80-85 Amps, 415 Volts, conforms to IS/IEC 60947-4-1 & IEC 60947-4-1 in and including providing auxilary conactors NO/NC complete all as specified and directed by Engr-in-Charge |
| 29 | Supply and fixing in repair contactor 3 pole 160 Amps, 415 Volts, conforms to IS/IEC 60947-4-1 & IEC 60947-4-1 in and including providing auxilary conactors NO/NC complete all as specified and directed by Engr-in-Charge. |
| 30 | Supply and fixing in repair contactor 3 pole 250 Amps, 415 Volts, conforms to IS/IEC 60947-4-1 & IEC 60947-4-1 in and including providing auxilary conactors NO/NC complete all as specified and directed by Engr-in-Charge |
| 31 | Supply and fixing in repair contactor 3 pole 400 Amps, 415 Volts, conforms to IS/IEC 60947-4-1 & IEC 60947-4-1 in and including providing auxilary conactors NO/NC complete all as specified and directed by Engr-in-Charge |
| 32 | Dismantaling of Existing serviciable DG Set of any capacity including Disconnectiong electric connection from Alternator & body and shifting with including crane and vehice safely at a distance not excceding 10 KM (Appx) at new loction within af Stn Jaisalmer and making electric connection complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 33 | Dismantaling of Existing serviciable DG Set of any capacity including Disconnectiong electric connection from Alternator & body and shifting with including crane and vehice safely at a distance not excceding 10 KM (Appx) at new loction within af Stn Jaisalmer and making electric connection complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender