Tender For Demolition And Reconstruction Of Sncos Living In Accn At Wac Subroto Park (Building Works On Design And Build Basis)
Tender Value
13.76 Crore
Estimated cost
Bid Submission
07 Aug 2026
15 days left
EMD
10.13 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Demolition And Reconstruction Of Sncos Living In Accn At Wac Subroto Park (Building Works On Design And Build Basis)
BOQ
| Sl. No. | Item Description |
| 1 | SCHEDULE `A' PART - I (Building / Structure Works) is not prepriced by MES and prepriced rates indicates 0.00 under column 5 signifies this fact only. |
| 2 | Design and construction of three storey (G+2) hybrid structure with LGSF Technology for SNCOs Mess and Living Accn for JWOs and Sgts all as shown on drawings and as specified. The following specifications including all facilities as per Design Basis Report shall also be followed:- |
| 3 | Foundation RCC foundation shall be done as per design and soil testing report. Hybrid Building Structure:Hybrid Solution using LGSF 550 MPA & 3 Plate - 345 MPA TATA or equivalent make steel designed in accordance with IS code - stadd & Framecad software duly painted with primer and paint – total 80 DFT.The structure to be duly fabricated in factory, site welding is not considered. |
| 4 | WALLS:(Internal & External)LGSF works: 150 GSM 550 MPA Zincalume sections – C75-100 mm sections 0.75/1.0 mm BM thickness, designed using Framecad/Supracad.The steel manufacturer shall provide an Environmental Product Declaration (EPD) to the MES, ensuring transparency in the material's environmental impact. The coated steel finish shall be free from defects and shall provide branding on back side with product details such as thickness, grade,coating mass, date, mfg. name and MES. The steel manufacturers test certificate for the chemical and mechanical properties of steel must be approved by the concerned engineer authorised by Engineer-in-charge prior to installation. The manufacturer of the steel and profile should be the same.Designed in IBC code but referring to IS codes and values |
| 5 | Decking and slab:Supply & Installation of Structural Decking 51 DECK Profile in Galvanized Steel shall be minimum 0.8mm thick BMT 550MPa yield strength as per IS 513 with a crest height of 51 mm at a pitch distance of 316mm c/c having a cover width of 960 mm, 3mm deep and 19 mm long embossment on either side of webs which are diagonally opposite to each other to provide the mechanical interlocking between the steel and concrete ensuring adequate composite action between steel and concrete.The panel shall have v”shape of 10mm deep on rib and panasa stiffener and male and female interlocking at side lap. The deck panel shall be coated with hot dipped zinc with coating mass of Z 275gm per sqm on both sides as per IS277 or approved equivalent as per direction of Engineer in charge.The Steel conforms to IS1397 and BSEN10147:2000. The profile comprises of intermediate male & female ribs for every interlocking of side lap joints. Thickness of the slab from top of deck sheet will be as per disign (Min thickness 100 mm). Water proofing treatment shall be provided on roof with tile as specified.Decking sheet to be installed using Studwelding as approved by Engineer in charge |
| 6 | External Wall:Supply & fixing of external wall system on Light gauge steel framework with outer face having 4 mm thick ACP panel or Terracotta wall cladding or combination of both as specified on top of 10 mm thick heavy duty fiber cement board confirming to to IS 14862:200, type A (High pressure steam cured) as per standard sizes fixed with self-drilling/taping screws/fasteners @ 60cm c/c of approved make. A grove of 2 mm to 3 mm shall be maintained and groves shall be sealed with silicon-based sealant. The board shall be fixed in a staggered pattern.Internal face 12mm thick calcium silicate board fixed on 10 mm thick fiber cement board confirming to IS 14862:2000 of category III type B (High pressure steam cured) as per standard sizes fixed with self-drilling/taping screws/fasteners @ 60cm c/c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.(i) A breathable vapour barrier underneath the cement fiber board as per National Building Code 2009.(ii) Providing and fixing thermal insulation with Resin bonded rock wool conforming to IS: 8183, having density 48 kg/m3, 75 mm thick fixed to wall. |
| 7 | Internal Wall:Supply & fixing 12 mm thick calcium silicate board on 10 mm thick fiber cement board on both the face of walls confirming to IS 14862 : 2000 of category III of type B(High pressure steam cured) as per standard sizes fixed with self-drilling/taping screws/fasteners @ 60cm c/c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.(i) PCC blocks and wall tiles to be used in toilet area as specified.(ii) Providing and fixing thermal insulation with Resin bonded rock wool conforming to IS: 8183, having density 48 kg/m3, 75 mm thick fixed to wall. |
| 8 | Wall insulation: Supply & fixing of 48 Kg/m3, 75 mm thick resin bonded rock wool insulation with aluminum foil over LGSF members. Window, flooring, door, plumbing and electrical works to be provided as specified. |
| 9 | NOTE: Schedule ‘A’ Part II to XIII under Ser No 2.01 to 2.12 are Prepriced by MES. |
| 10 | Lump sum price worked out by the Contractor for “ SITE CLEARANCE, EXCAVATION AND EARTH WORK ” as listed in Schedule ‘A’ Part II |
| 11 | Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION) ” as listed in Schedule ‘A’ Part III |
| 12 | Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY WORKS\\" as listed in Schedule ‘A’ Part IV |
| 13 | Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY WORKS\\" as listed in Schedule ‘A’ Part V |
| 14 | Lump sum price worked out by the Contractor for \\"EXTERNAL ELECTRIC SUPPLY WORKS” as listed in Schedule ‘A’ Part- VI |
| 15 | Lump sum price worked out by the Contractor for “ROAD , PATH AND CULVERT ” as listed in Schedule ‘A’ Part- VII |
| 16 | Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL WORKS” as listed in Schedule ‘A’ Part -VIII |
| 17 | Lump sum price worked out by the Contractor for \\"AREA DRAINAGE WORKS” as listed in Schedule ‘A’ Part IX |
| 18 | Lump sum price worked out by the Contractor for “COMPOUND WALL/GATE\\" as listed in Schedule ‘A’ Part X |
| 19 | Lump sum price worked out by the Contractor for “RAIN WATER HARVESTING\\" as listed in Schedule ‘A’ Part XI |
| 20 | Lump sum price worked out by the Contractor for “AIR CONDITIONING\\" as listed in Schedule ‘A’ Part XII |
| 21 | Lump sum price worked out by the Contractor for “CENTRAL AIR COOLING SYSTEM\\" as listed in Schedule ‘A’ Part XIII |
| 22 | Lump sum price worked out by the Contractor for “DEMOLITION AND DISMANTLING WORKS\\" as listed in Schedule ‘A’ Part XIV |
| 23 | SCHEDULE `A' PART - XVI MISC ITEMS (B/R & E/M, srl Item No.3.01 to 3.31) is not prepriced by MES and prepriced rates indicate 0.00 under column 5 signifies this fact only. |
| 24 | EXTERNAL WATER SUPPLY |
| 25 | Supply and laying Galvanised Iron (GI) pipe, \\" medium grade\\" including fitting of size 63 mm dia complete all specified and directed. |
| 26 | M&L for construction of valve chamber of size 900x900x1200mm internal size suitable for valves with PCC 1:4:8 type D 2 for foundation and brick masonry wall in cement mortar 1:6 PCC 1:3:6 type C 1 for coping rendering in CM 1:4,15mm thick including Provn of mild steel sheet cover 3.0mm thick on 40x40xx6mm angle iron frame work with two coats of synthetic enamel black paint over a coat of red oxide primer and locking arrangement including necessary excavation earth work all as specified and directed. |
| 27 | EXTERNAL ELECTRIC SUPPLY |
| 28 | Boring of holes under road ,Pavement ,hard standing trench less technolgy using ultra sound technique and necessary machine incl HDPE pipe of 150mm dia suitable for 0.4mpa working pressure complete all specified and directed. |
| 29 | S&F cable joining kit for 1.1 KV grade cable for indoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE, armoured Al conductor cable of size 400 sqmm complete all specified and directed. |
| 30 | Supply and Fixing LED Building security light fitting 25 watt including bracket, clamps and twin core wire for connection complete all as specified and directed. |
| 31 | Supply , install , test & commissioning of CPRI approved LT Panel of size 2000 mmx 1800mmx 900mm, indoor, Cubicle type, factory fabricated out of CRCA Sheet of 3.15 mm thick dust, vermin proof, weather proof, IP-54 Grade of protection, fabricated on 50x50x5 mm thick MS angle iron frame both side opening and locking arrangement including providing Aluminium bus bar of capacity 800 Amps rating for 415 V 50 Hz 3 Phase system including interconnection with multistranded conductor/Strips/Wires/Cables with hot shrink color coded sleeves with RYB colours and suitable adopter boxes with spreader links for connecting cables with switch terminals ,cable gland for each cable (Where necessary) complete all as specified and directed with following:-. ( Main LT Panel)INCOMING:-(a) MCCB 500 Amps 4 pole 50 K A(b) Voltmeter 0-500 volt(c) Amperemeter 0-600 Amp(d) Phase Indicating LED Lamp (03 Nos R Y B)(e) Bus Bar copper 800 A ratingOUT GOING:-(a) MCCB 200 Amps 4 pole 25 KA-01(b) MCCB 160 Amps 4 pole 25 KA-03 (c) MCCB 100 Amps 4 pole 25 KA-01 |
| 32 | INTERNAL ELECTRIC SUPPLY |
| 33 | Supply and fixing of Modular metal flush box 8 module complete all as specified and directed. |
| 34 | Supply and fixing of Modular metal flush box 12 module complete all as specified and directed. |
| 35 | Supply and fixing of modular cover plate white with frame complete for 12 module complete all as specified and directed. |
| 36 | Supply and fixing energy saving decorative box type batten light fitting 230 Volts surface mounted complete with high efficiency PMMA diffuser soft glare free light LED Tube light 10 watt ,blue coloured and caps with all accessories pre-wired,including providing flexible copper wire ,three core cable PVC insulated sheathed complete all as specified and directed by Engineer-in Charge |
| 37 | S & F telephone jack complete all as specified and directed. |
| 38 | S & F TV jack complete all as specified and directed. |
| 39 | M & L for VTPN 8 way sheet steel enclosure distribution boards, double door factory made 3 phase 415 volts, 100 A MCCB as incomer and 24 single phase outgoing copper bus bar of suitable size and PVC insulated to the out going circuits,complete all as specified and directed |
| 40 | Supply and fixing energy saving deep recessed down light fitting 230 Volts surface mounted complete with high efficiency soft glare free light LED round ceiling light having color temperature of 2700 to 3000 K (warm color) light 15 watt , with all accessories pre-wired,including providing flexible copper wire ,three core cable PVC insulated sheathed complete all as specified and directed by Engineer-in Charge |
| 41 | RAIN WATER HARVESTING |
| 42 | M&L for drilling 250 mm dia bore holes by DHT cum rotary method at any depth as in any type of soil maximum upto 200 mtr depth from natural ground level and including removal of surplus soil to a distance n exc 50M complete all as specified and directed. ( trial bore of 200mm dia upto 200mtr depth below ground level if any kind of soil strata incl hard stone /bolder incl elec loging ,ms cap ,ms plate iron clamp reducing socket etc.) |
| 43 | M & L for PVC pipe 200mm dia of pressure rating 6 Kgf/Sqcm laid in recharge pit all as specified and directed . |
| 44 | M & L for PVC perforated pipe 200mm dia of pressure rating 6 Kgf/Sqcm laid in recharge pit all as specified and directed . |
| 45 | GREASE TRAP |
| 46 | Removal & refixing of German Technology grease trap & restoring connections and other unforeseen items like shifting of cable, water supply line, sewage and other items complete all as specified and directed. |
| 47 | AIRCONDITIONING & REFRIGERATION |
| 48 | Supply and fix air cooled cassette type air conditioner, inverter based, electric driven, single phase units 220V - 240V, 50 Hz of capacity 3.5 TR, BEE 5 star rated complete all as specified and directed. |
| 49 | Supply and fix refrigerator, electric driven ( Single phase), capacity 310 Ltr, single phase units 220V - 240V, 50 Hz, BEE 5 star rated complete all as specified and directed. |
| 50 | CENTRAL AIR COOLING SYSTEM |
| 51 | Supply , install , testing & commissioning of CPRI approved LT Panel of size 1000 mmx 900mmx 900mm, outdoor, Cubicle type, factory fabricated out of CRCA Sheet of 3.15 mm thick dust, vermin proof, weather proof, IP-54 Grade of protection, fabricated on 50x50x5 mm thick MS angle iron frame both side opening and locking arrangement including providing Aluminium bus bar of capacity 250 Amps rating for 415 V 50 Hz 3 Phase system including interconnection with multistranded conductor/Strips/Wires/Cables with hot shrink color coded sleeves with RYB colours and suitable adopter boxes with spreader links for connecting cables with switch terminals ,cable gland for each cable (Where necessary) complete all as specified and directed with following:-. ( Air Cooler Panel)INCOMING(a) MCCB 160 Amps 4 pole 16 KA (b) Voltmeter 0-500 volt(c) Amperemeter 0-400 Amp(d) Phase Indicating LED Lamp (03 Nos R Y B)(e) Bus Bar Aluminium 250 A ratingOUT GOING(a ) MCCB 20 Amps 4 pole 16 KA ( Second floor)-02 Nos(b ) MCCB 63 Amps 4 pole 16 KA (G/F & F/F)- 02 Nos |
| 52 | Supply, Installation, testing and commissioning of Centralize evaporative Air Cooling system (Central Air Cooler) for G+2 comprising of following:-Coolator @ 43 Plus -43000CMH/25000 CFM of static pressure 80 mmwg -01 NosFor Ground and First FloorCoolator @ 34 plus - 34000 CMH / 20000 CFM of static pressure 80 mmwg -01 NosFor Ground and First FloorCoolator @ 17 plus - 17000 CMH / 10000 CFM of static pressure 80 mmwg -02 NosFor Second FloorEletric controller Elect Controller with 2 meter wire for connection with starter, MCCB, Contactor,Start/ Stop button,Overload relay, Single phase preventer and short circuit protection etc for Coolator -43 plus,Coolator -34 plus,Coolator -17 plus,Rectangular ductingDucting of size 22 gauge & 24 gauge GI sheet including duct support with nut, gasket joint, angle mounted threaded rod support with anchor fastnerSupply Air GrillAluminium powder coated supply air grill with damperCanvas ConnectionSupply and installation of canvas connectionThermal insulationNitrile thermal insulation with 13 mm thick Aluminium foilNote:- Provide the manual damper for ON/OFF the air flow duct for individual rooms and control/regulate individual room air flow primarily through manual air balancing dampers installed in ductwork. |
| 53 | DEMOLITION AND DISMANTLING |
| 54 | Taking down flushing cisterns and flushing pipes of any description/capacity complete all as specified and directed. |
| 55 | Taking down wash basins vitreous china any size and type including brackets complete all as specified and directed. |
| 56 | Taking down old u/s Bib taps 15mm bore any type complete all as specified and directed. |
| 57 | Taking down old u/s stop /angle valve 15mm bore complete all as specified and directed. |
| 58 | Dismantling existing old unserviceable LT panel including all accessories complete all as specified and directed. |
| 59 | Taking down the old MCBs/MCCBs any type by necessary cutting, chasses including disconnection of incoming and out going cable etc complete all as specified and directed. |
| 60 | Disconnecting and taking down unserviceable cable of size 50/95/120 Sqmm from pole/main switch board complete including necessary excavation complete all as specified and directed. |
| 61 | Taking out carefully earthing set complete of any type including earthing wire/strip complete all as specified and directed. |
| 62 | Taking down the TPN DBs any type by necessary cutting, chasses including disconnection of incoming and out going cable etc ccomplete all as specified and directed. |
| 63 | Taking down the SPN DBs by necessary cutting, chasses including disconnection of incoming and out going cable etc complete all as specified and directed. |
| 64 | Dismantling Tube Light fitting single / double rod/ Ceiling light fitting any type and wattage or CFL fitting of any type and bulk head fitting of any type or wattage, decorative light fitting complete all as specified and directed. |
| 65 | Disconnecting and taking down unserviceable cable of size 10 Sqmm/ 16 Sqmm/ 25 Sqmm from pole/main switch board complete all as specified and directed. |
| 66 | Taking down the Metal clad plug any type by necessary cutting, chasses including disconnection of incoming and out going cable etc complete all as specified and directed. |
| 67 | Taking down including disconnecting the electric connection of ceiling / exhaust/ ventilation fan dismantling blades, cleaning and depositing to store MES store yard complete all as specified and directed. |
| 68 | Taking down including disconnecting the electric connection of Geysers and depositing to store MES store yard complete all as specified and directed. |
| 69 | MISC ITEMS |
| 70 | Supply only stainless steel heavy duty foldable cloth drying stand (large) of size (LxBxH) 3'x2.58'x5.6', outdoor, rust proof, water proof fully assembled as approved. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysAug 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender