Defence Statutory Bodies & Commissions/Committees Closing in 9 days TDR #56531808

Tender For Repair And Replacement Of Old Unsv Defected Lt Panels, Ug Cables, Lt Switch Gear Items In Central Ac Plants Under Ge (I) Gos.

Issued by Statutory Bodies & Commissions/Committees · Ganjam, Odisha
Tender Value
Ref. Documents
Estimated cost
Bid Submission
10 Aug 2026
9 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ganjam → Odisha
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair And Replacement Of Old Unsv Defected Lt Panels, Ug Cables, Lt Switch Gear Items In Central Ac Plants Under Ge (I) Gos.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 30-Jul-2026 corrigendum1 Other 10-Aug-2026

BOQ

Name of Work:- REPAIR AND REPLACEMENT OF OLD UNSV DEFECTED LT PANELS, UG CABLES, LT SWITCH GEAR ITEMS IN CENTRAL AC PLANTS UNDER GE (I) GOS.
Sl. No. Item Description
1Taking down old unsv/burnt LT panels/Feede pillar of any capacity and supply, install, testing and commissinoning of LT panel board indoor type of size 2250 mm long X1800 mm width X 400 mm thickness(depth) (length and width and thickness of LT panel sizes if required for heigher & lower size as required and decided by Engr-in-charge) with single door type suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz, ,cubicle and shall have air ventilation arrangement,IP-54 Protection, floor mounted, free standing, dust and vermin proof, with see through glass as per requirement made out of 2 to 2.15mm thick at outer sheet and 1.60 mm thick at internal compartments CRCA sheet and necessary angle/flat irons duly powder coated, hinged doors with rubber gasket, handles.Panel shall have front and rear opening,locking arrangement,cable alleys,cable entry holes for incoming and out going cables,busbar chamber and switch gear compartment,see through glass for indicator lamps, control copper wiring & safety fuses,earthing terminals,affix danger notice plate,aluminium busbar fixed on DMC/SMC insulators and all incoming and outgoing internal connection should be connected suitable rating aluminium bus bars only with RYB color code sleeves/taps, and the panel will be mounted on 50mmX50mmX6 mm GI angle iron base frame of height 45 CM above GL as per site requirement and below GL 45 CM and including connecting up of existing incoming and out going cables by using new aluminium lugs and cable gland and connecting of earth strip and providing civil work/PCC foundation (1:2:4) type B1 with studs,bolts,nuts & washers as per site requirement. And complete all as specified and directed and including comprising of following:-
2Note:- (i) LT panel board manufactured by any manufacturer should be followed by CPRI norms/certified and also zonal approved maufacturers only. (ii)The contractor shall be arranged General (SLD), circuit lay out drawings & Switch gear items makes/brands submitted for prior approval by the Accepting Officer/Engineer -in-charge before procurement/ordering.(i) Incoming:- MCCB,4 pole,400 Amps,415 Volts, 35/36 KA,50Hzs Manual drawout type with THERMAL MAGNETIC based release system incl factory fabricated steel spreader links & steel nuts,bolts and washers of suitable amps rating in RYB &N.-01 Nos (ii) Outgoing :- ON-Load change over switch with front operated handle 315Amps,415Volts 4 Pole incl steel coated factory fabricated spreader links & steel nuts,bolts and washers of suitable amps rating in RYB &N-01 Nos.
3(iv) MCCB,4 pole,125 Amps,415 Volts, 25 KA,50Hzs Manual drawout type with thermal magnetic based release system incl factory fabricated steel spreader links & steel nuts,bolts and washers of suitable amps rating in RYB (v) MCCB,4 pole,100 Amps,415 Volts, 25 KA,50Hzs Manual drawout type with thermal magnetic based release system incl factory fabricated steel spreader links & steel nuts,bolts and washers of suitable amps rating in RYB (vi) MCCB,4 pole,63 Amps,415 Volts, 16/18 to 25 KA,50Hzs Manual drawout type with thermal magnetic based release system incl factory fabricated steel spreader links & steel nuts,bolts and washers of suitable amps rating in RYB (viii) R,Y,B Phase indicating lamp -01 Set Make:- Jigo/L&T/C&S(ix) Digital Ammeter (0 amps to 500 Amps) with ASS (Ammeter selector switches) -01 No.(x) 400/5A current transformer -03 No's (xi) Digital Voltmeter( 0Volts to 500Volts)-01 No with VSS,(xii) Protection fuses& controll wiring -03 Nos (xiii) Main bus bar & distribution out going distribution busbar size and amps rating x1.5 times rating of controlling MCCBs capacity TPN bus bar 400 amps rating -01 Set
4Taking out old unsv existing on load change over with wall mouted sheet steel enclosure any type/rating and incl providing supply and fix on load change over switch 415V in wall mounted sheet metal enclosure/open excution type/side handle type as per site requiremet 4 pole of capacity 400 amps and including providing incoming and outgoing cables features and necessary hole fasters, lugs,nuts,bolts and washers etc and including providing necessary alterations,welding works in existing panels/on wall mounting fitting complete all as specified and directed.
5Taking out old unsv existing on load change over with wall mouted sheet steel enclosure any type/rating and incl providing supply and fix on load change over switch 415V in wall mounted sheet metal enclosure/open excution type/side handle type as per site requiremet 4 pole of capacity 250 amps and including providing incoming and outgoing cables features and necessary hole fasters, lugs,nuts,bolts and washers etc and including providing necessary alterations,welding works in existing panels/on wall mounting fitting complete all as specified and directed.
6Taking down old unsv busbar from existing location and incl providing supply and fix supply and fix compact air insulated rising main busbar made in 2 mm sheet steel metal enclosure with ETP grade copper bus bar,4 pole, 315/320A,4 way amps,busbar breaking capacity of 35 KA and IP 54 protection suitable for wall mounted concealed in wall surface level and including providing incoming and outgoing features and necessary conneceted accessopries complete all as specified and directed .
7Taking down old rusted unsv cable tray from existing location and supply and fixing new pre galvanized pertorated cable tray 100mm x 100 mmx1.60mm suitable for fixing on wall/roof hanging/ floor mounted as per site requirement and including providing GI hanging rod,nuts,bolts and washers complete all as specified and directed.
8Taking down old rusted unsv cable tray from existing location and supply and fixing new pre galvanized pertorated cable tray 100mm x 50 mmx1.60 mm suitable for fixing on wall/roof hanging/ floor mounted as per site requirement and including providing GI hanging rod,nuts,bolts and washers complete all as specified and directed.
9Taking down old unsv busbar from existing location and incl providing supply and fix supply and fix compact air insulated rising main busbar made in 2 mm sheet steel metal enclosure with ETP grade copper bus bar,4 pole, 250A,4 way amps,busbar breaking capacity of 35 KA and IP 54 protection suitable for wall mounted concealed in wall surface level and including providing incoming and outgoing features and necessary conneceted accessopries complete all as specified and directed .
10Material and labour for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron strip of size 32 X 6 mm from earth electrode to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate no 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including char coal, salt packed all around the earth electrode plate in layers,PCC earth pit chamber 1:3:6 type C1,RCC cover 1:2:4 type B1, including excavation,earth work in any strata and returning filling, removal of surplus soil and testing for required value complete all as specified and directed.
11M&L for PVC insulated sheathed single core 70 sqmm unarmed LT copper conductor cable as earth continuity conductor with galvanized shaddle with screws for two number in each running metre complete all as specified and directed.
12M&L for PVC insulated sheathed single core 16 sqmm unarmed LT copper conductor cable FRLS type complete all as specified and directed.
13M&L for PVC insulated sheathed single core 25 sqmm unarmed LT copper conductor cable FRLS type complete all as specified and directed.
14M& L for in repair earthing continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn inconduit pipe or fixed to poles or any other indicated situation for loop earthing etc as required galvanised iron steel earth strip of size 25x4 mm size for earthing connectivity conductor incl providing suitable heavy duty insulators,nuts,bolts and screws etc with insulators for three number in each running metre complete all as specified and directed.
15Cutting of bituminous top road,PCC surface/floor by using mechanical method incl road boaring/cutting any type carefully without damagig to surrounding area complete all as spfd and directed.
16Material and labour for PCC 1:2:4 type B1 using 20 mm grade aggregate as in pre cast cover slabs including form work and set in cement motor 1:6 complete all as spfd and directed.
17Supply and fixing galvanised steel cable tray of size 250mm X100 mmx 5 mm tray fixing on wall with proper nuts,bolts ,GI clamps and washers etc fixing at ay height on wall surface and necessary anchoring arrangements,cuttings,jointings,weldigs,fabrication as per site reqt suitable for UG cable laying complete all as specified and directed.
18Material & labour for GI pipe 80 mm \\" light grade'' laid in trenches floors/on,pole/road for cable protection with all fittings complete all as specified and directed.
19Boaring holes horizontally under road without damaging the surface of road (minimum 1.0 Mtr bellow the road surface) with the help of GI tubing of any dia not exc 80mm dia for passing of UG cable all as specified and as directed.
20Supply and filling in and spreading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in SSR Part-I and as directed.
21Excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft loose soil complete all as specified and directed.
22Returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed
23Removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed
24M & L for brick sub class 'B' 250mm x 115mm x 0.75mm and laid in trenches as in protection of UG cable complete all as specified and directed.
25Material & labour for GI pipe 50 mm \\"light grade\\" laid in trenches floors/on , pole/road for cable protection with all fittings complete all as specified and directed.
26Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 16 sqmm,3.5 core complete all as specified and directed.
27Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 25 sqmm,3.5 core complete all as specified and directed.
28Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 35 sqmm,3.5 core complete all as specified and directed.
29Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 50 sqmm,3.5 core complete all as specified and directed.
30Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 70 sqmm,3.5 core complete all as specified and directed.
31Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 95 sqmm,3.5 core complete all as specified and directed.
32Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 120 sqmm,3.5 core complete all as specified and directed.
33Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 150 sqmm,3.5 core complete all as specified and directed.
34Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 185 sqmm,3.5 core complete all as specified and directed.
35Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 240 sqmm,3.5 core complete all as specified and directed.
36Supply, installation,testing and commissioning of 8.5 TR (Tons of Refrigeration) AC compressor heavy-duty commercial unit scroll compressor designed for ductable ACs, package units, and chillers, operate on 3-phase power (380–420V), cooling capacity 102,000 BTU/h (8.5 tons) motor power 10HP to 11HP, primerilly Refrigerant R410A, R407C, or R22 (depending on the system age) all as specified and directed by Eng-in-Charge.
37M&L for replacement of cast iron sluice valve with stainless steel spindles with flanged ends duly ISI marked confirming to IS 780 part1, PN 1 type complete suitable as per exiting AC plant for the 100 MM bore sizes complete all as specified and directed.
38All as per item No 37 above but 80 MM bore
39All as per item No 37 above but 65 MM bore
40Taking down old unsv butterfly valve from existing location and supply and fixing new butterfly valve of size 100 mm dia and including necessary pipe fittings nuts,bolts,washers and rubber washers etc complete all as specified and directed
41All as per item No.40 above but size 80 mm dia.
42All as per item No.40 above but size 65 mm dia.
43All as per item No.40 above but size 50 mm dia.
44Taking down old unsv Non return valve from existing location and supply and fixing new non return valve of size 100 mm dia and including necessary pipe fittings, nuts,bolts,washers and rubber washers etc complete all as specified and directed
45All as per item No.44 above but size 80 mm dia.
46All as per item No.44 above but size 65 mm dia.
47All as per item No.44 above but size 50 mm dia.
48Taking down old unsv Non return butterfly valve from existing location and supply and fixing new non return butterfly valve valve of size 100 mm dia and including necessary pipe fittings, nuts,bolts,washers and rubber washers etc complete all as specified and directed
49All as per item No.48 above but size 80 mm dia.
50All as per item No.48 above but size 65 mm dia.
51All as per item No.48 above but size 50 mm dia.
52Taking down old unsv pipe line from existing loaction and supply and fixing new MS ERW heavy duty pipe of size 100 mm dia with fittinmgs and including providing necessary fabrication,welding work and accessories nuts,bolts and washers complete all as specified and directed.
53All as per item No.52 above but size 80 mm dia.
54All as per item No.52 above but size 65 mm dia.
55All as per item No.52 above but size 50 mm dia.
56Taking down old unsv pipe line from existing loaction and supply and fixing new GI heavy duty pipe of size 100 mm dia with fittings and including providing necessary fabrication,welding work and accessories nuts,bolts and washers complete all as specified and directed.
57All as per item No.56 above but size 80 mm dia.
58All as per item No.56 above but size 65 mm dia.
59All as per item No.56 above but size 50 mm dia.
60All as per item No.56 above but size 40 mm dia.
61All as per item No.56 above but size 32 mm dia.
62All as per item No.56 above but size 25 mm dia.
63Taking down old unsv gate valves from existing loaction and supply and fixing new gate valve of size 100 mm dia with necessary accessories nuts,bolts and washers complete all as specified and directed.
64All as per item No.63 above but size 80 mm dia.
65All as per item No.63 above but size 65 mm dia.
66All as per item No.63 above but size 50 mm dia.
67All as per item No.63 above but size 25 mm dia.
68Taking down old unsv strainer for suction from existing loaction and supply and fixing new strainer of size 150 mm dia with necessary accessories nuts,bolts and washers complete all as specified and directed.
69All as per item No.68 above but size 100mm dia.
70Supply and install,testing and commissioning of monoblock pumpsets suitable for 415 volts 3 phase, 50Hzs,rpm 2880-3000 capacity of 10 HP including necessary suitable fittings such has flanges,reduced sokets, nipple, suitable water pressure guage 7 Kg or 10 kg X100 mm dia and replace old CI foot valve with GM working parts( IS-4037) 100/150mm dia, bend,Tee , nuts, bolts required at site and necessary threading,welding and drilling etc complete all as specified and directed by Engr-in -Charge.
71Supply,install, Commissioning and testing of capacity of cooling tower 100 TR, one no twin cell type corrosion resistant,fire retardant,FRP induced draft,rectangular/square type counter flow cooling tower of capacity 120% of plant running capacity with maximium allowable temperature 50 degree centigrade,drift loss 0.005% of water circulation,such as 80TR,water flow rate USGPM-1500,Inlet temp-97.5F,outlet temp-90F,wet bulb temp-83F,FRP materials,suitable mechanical eqpt-hot dip galvanized UV stabilized,PVC piping work,incl aluminium fan hub and blades-06 Nos,suitable size blades,fan motor 5 HP,960 rpm, dry weight 500 kgs,operating weight approx 1750 kgs, size suitable for as existing,incl sprinklers and functioning required connected items and including removing old unserviceable complete all as specified and directed.
72Supply and fix MCCB, 200 Amps,4 pole,415 Volts , 16/18KA thermal magnetic type with necessary lugs,thimbles, nuts bolts and washers and including removing old unserviceable item complete all as specified and as directed.
73Supply and fix MCCB, 250 Amps,4 pole,415 Volts , 16/18KA thermal magnetic type with necessary lugs,thimbles, nuts bolts and washers and including removing old unserviceable item complete all as specified and as directed.
74Supply and fix MCCB, 315 Amps,4 pole,415 Volts , 16/18KA thermal magnetic type with necessary lugs,thimbles, nuts bolts and washers and including removing old unserviceable item complete all as specified and as directed.
75Supply and fix MCCB, 400 Amps,4 pole,415 Volts , 16/18KA thermal magnetic type with necessary lugs,thimbles, nuts bolts and washers and including removing old unserviceable item complete all as specified and as directed.
76Supply and fix MCCB, 630 Amps,4 pole,415 Volts , 16/18KA thermal magnetic type with necessary lugs,thimbles, nuts bolts and washers and including removing old unserviceable item complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56531808
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 10-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair And Replacement Of Old Unsv Defected Lt Panels, Ug Cables, Lt Switch Gear Items In Central Ac Plants Under Ge (I) Gos.
Basic Detail
Tender No GE/GOS/TOK/94 OF 2026-27
Bidding Type Tender
Location
City Ganjam
State Odisha
Key Dates
Publish Date 30 Jul 2026
Submission Date 10 Aug 2026
Open Date 01 Jan 0001
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 80000
Exemption Not Available
Document List
a32d89a8-0b8c-4dda-86f7-b4a32ae1cb49.html
BOQ_872942.xls
Tendernotice_1.pdf
tender_docs.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 10, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 9 days
Aug 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

a32d89a8-0b8c-4dda-86f7-b4a32ae1cb49.html

xls

BOQ_872942.xls

pdf

Tendernotice_1.pdf

pdf

tender_docs.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders