Tender For Addition/Alteration To Bldg No.T-24 & T-25,Provn Of Fol Dump At Mt Park And Provn Of Approx 250 Mtrs Sewage Drainage System Behind Or Living Lines Bathroom Near Bldg No.T-51 At Outpocket Mil Stn Under Ge Dinjan No.2
Tender Overview
Project Description
Tender for Addition/Alteration To Bldg No.T-24 & T-25,Provn Of Fol Dump At Mt Park And Provn Of Approx 250 Mtrs Sewage Drainage System Behind Or Living Lines Bathroom Near Bldg No.T-51 At Outpocket Mil Stn Under Ge Dinjan No.2
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 2 | S&F coloured 0.50mm thick pre-painted galvalume aluminium zinc coating GI based trapezoid profile corrugated steel sheet having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws alongwith bitumen washer complete all as specified and directed. |
| 3 | S&F coloured 0.50mm thick pre-painted galvalume aluminium zinc coating GI based trapezoid profile steel sheet having tensile strength of 550 Mpa as in ridge, valley gutter or of similar type, fixed with self tapping screws alongwith bitumen washer complete all as specified and directed.Note- The measurement shall be carried out as in a plain sheet. |
| 4 | Taking down chowkhats or frames with shutters without taking off shutters from the frames not exceeding 1.5 Sqm each complete all as specified and directed. |
| 5 | Taking down chowkhats or frames with shutters without taking off shutters from the frames exceeding 1.5 Sqm but n.exceeding 4 sqm each complete all as specified and directed. |
| 6 | S & F for Rolled Mild Steel hollow section support for doors and window frame including cutting to shape, all necessary drilling, bolting, welding or riveting, etc. and similar work conforming to Fe 290 ( Gde E-165) complete all as specified and directed. |
| 7 | S&F exposed GI powder coated snap grid frame work for false ceiling in flat or in sloping, of grid size 600 x 600 mm comprising of wall/ cleat angle of size 25x25x0.35 mm and corss tee of size 24x38x0.70 mm with 4 mm dia GI wire as suspender and including 4 mm thick decorative pre-painted non asbestos board (E-Board) in false ceiling including fixing arrangement from steel/ wooden truss of any type including dismantling of existing false ceiling boards, complete in all respect as specified and directed. |
| 8 | Providing and laying skid/non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floor etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match tile colour over 15 mm thick screed bed in cement mortar (CM) 1:6, complete in all respect as specified and directed. |
| 9 | Providing and laying skid/non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in Skriting/dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match tile colour over 15 mm thick rendering in cement mortar (CM) 1:4, complete in all respect as specified and directed. |
| 10 | M & L For Roughening surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust including brushing neat cement slurry with 3.0 kg of cement per sqm etc., complete in all as specified and directed. |
| 11 | S & F for Factory made double extruded WPC (wood polymer composite) solid door/ window / ceosetory windows & other frames / chowkhat of size 65X125 mm comprising of virgin PVC polymer of K value 58-60 (suspension Grade), calcium carbonate and natural fibers (wood power / rice husk /wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having maximum frame density of 750 kg / cum, screw withdrawel strength of 2200 N (Face) & 1100 N (Edge), minimum comprssive strength of 58 N / mm², Modules of elasticity 900 N / mm² and resistance to spread of flame of class A category with property of beeing termite / borer proof, water / moisture proof and fire retardant and fixed in position with MS hold fast / lugs / SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast / lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door / window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 12 | S&F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panel covered with decorative face veneer with lipping/frame to match on both sides, complete in all respect as specified and directed. |
| 13 | Supply and fixing to existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and as per directions of Engineer- in-charge. |
| 14 | Supply and fixing for powder coated anodised aluminium three tier frame for doors, windows, ventilator with one or more rebeats including joining cleat for fixing etc., complete in all as specified and directed.(Note : minimum thickness of powder coating 50 micron) |
| 15 | Providing and fixing for powder coated anodised aluminium three tier shutter for windows, ventilator shutters comprising of glazed and gauzed panels fabricated from extruded aluminium sections confirming IS: 733 and IS: 1285, of of approved size of specifications and drawings. aluminium section shall be electrostatically powder coated with epoxy poiyester powder coating of minimum 50 micron thk in approved shade/ colour. The three tier window shutters shall consist of outer glazed and inner glazed/gauzed shutters and adjustable/ openable arrangement as specified, fabricated from tubular aluminium section with mechanically cleated / crimped joints. The glazed portion shall be fitted with glass panes of specified thk fixed with EPDM / neoprene gasket, galzing clips and snap beading. The gauzed shutter shall be fitted with stainless steel wire Gauze of approved quality fixed with aluminium beading complete. The shutter shall be provided with all necessary accesories and fitting including aluminium handles, locking arrangement, hinges, rollers/ friction stays, tower bolts, weather striping, wool pile, screws, cleats, fixing lugs, sealant and other fixtures complete all joints shall be smooth, rigid and watertight. The work shall be include cutting, fitting, fixing and making good to adjoining surfaces complete in all as specified and directed. |
| 16 | S&F 4 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq.m in each pane, complete in all respect as specified and directed. |
| 17 | S&F 4 mm thick figured glass, pin head type and glazing with oil putty in square n.exc 0.5 sqm in each pane, complete in all respect as specified and directed. |
| 18 | S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width aperture 1.40 mm and fixed with stainless steel wire staples fixing withbeads, complete in all respect as specified and directed. |
| 19 | S&F PVC coloured insulated over MS pipe 20 mm dia curtain rod with fixing bracket, stops, rollers etc. complete all as specified and directed. |
| 20 | Providing and laying plinth protection of 75mm thick cement concrete, using type C-1, (1:3:6) (using 20mm nominal size crushed and graded stone aggregate), laid in alternate penals/bays and finished the surafce even and smooth without using extra cement complete in all respect as specifified and directed. |
| 21 | M & L for Broken stone or boulders hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete in all respect as specified and directed |
| 22 | M & L 15mm thick plastering on brick/stone/concrete surafces of wall in cement mortar (1:6) finished even and smooth without using extra cement complete in all respect as specifified and directed. |
| 23 | M & L 15mm thick screed bed on brick/stone/concrete surafces of roof surfaces in cement mortar (1:3) finished even and smooth without using extra cement complete in all respect as specifified and directed. |
| 24 | M&L 10 mm thick plastering on brick/ stone/ concrete surfaces of ceiling in cement mortar (1:3) finished even and smooth without using extra cement, complete in all respect as specified and directed. |
| 25 | M & L 15mm thick plastering on brick/stone/concrete surafces of wall in cement mortar (1:4) finished even and smooth without using extra cement complete in all respect as specifified and directed. |
| 26 | Preparaing new un decorated plastered or unplastered surface of wall and apply apply two coat of weather coat over one coat of alkali resistant priming paint complete in all respect as specified and directed. |
| 27 | Preparaing old platered surface of wall and apply two coat of weather coat over one coat of alkalai resistant priming paint including washing, rubbing down and stopping of distembered and painted surface complete in all respect as specified and directed. |
| 28 | M&L for preparation of old decorated surface of wall and applying two coats of weather coat over a coat of alkali resistant primer including including washing, rubbing down and stopping of distembered and painted etc., complete in all respect as specified and directed. |
| 29 | M&L for preparation of old decorated plastered surface of wall and applying two coats of oil bound distemper (OBD) over one coat of alkali resistant priming paint including washing, rubbing down and stopping of distembered and painted surface complete in all respect as specified and directed. |
| 30 | M&L for preparation of new undecorated steel surfaces with pre mixed steel filler used as putty for steel work and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer before painting complete all as specified and directed. |
| 31 | M&L for preparation of old decorated steel surface of any description not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint, over one coat of red oxide zinc chrome etc, complete in all respect as specified and directed. |
| 32 | S&F 150mm length of bolt, Aluminium anodised, barrel tower bolt of extruded section complete all as specified and directed. |
| 33 | S&F 150 mm size, Aluminium handle cast type anodised complete all as specified and directed. |
| 34 | S&F aluminium anodised sliding door bolts with hasp and staple (boil type) 19mm dia bolt 300 mm long complete all as specified and directed. |
| 35 | S&F aluminium anodised sliding door bolts with hasp and staple (boilt type) 16 mm dia bolt, 250 mm long, with and including a minium of 6 bolts and nuts four on bolt plate and two on staple plate, complete in all respect as specified and directed |
| 36 | S&F 100mm size mild steel butt hinges complete all as specified and directed. |
| 37 | Surface excavation n.exc 30 cm deep and averaging 15 cm deep geeting out in soft/loose soil. |
| 38 | Excavating in trenches, n. exc 1.5 m wide and n. exc 1.5 m in depth; for foundation,and laying of pipe etc. and getting out in soft/loose soil complete in all respect as specified and directed |
| 39 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete in all respect as specified and directed. |
| 40 | Removing excavated material n. exc. 50m and depositing where directed at a level n. exc. 1.5 m above the starting point complete in all respect as specified and directed. |
| 41 | M&L for PCC (1:4:8) type D2 (using 40mm crushed and graded stone aggregate) as in foundation and mass filling complete in all respect as specified and directed. |
| 42 | M & L PCC (1:3:6) type C-1 using 20 mm nominal size crushed and graded stone aggregate in coping, hold fasts or of similar items including necessary cutting, form work etc.complete in all respect as specified and directed. |
| 43 | M&L for PCC 1:3:6 type C1 (using 20mm nominal size crushed and graded stone aggregate) as in surface channels & drains complete in all respect as specified and directed. |
| 44 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PC mould, laid in required colour & pattern over and including 50mm thk compacted bed of fine sand, compacting and propper embedding/ laying of interlock paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete in all as specified and directed. |
| 45 | Providing and laying for reinforced cement concrete type B-1, 1:2:4 (using 20mm nominal size crushed and graded stone aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; complete in all respect as specifified and directed. |
| 46 | Providing and laying for reinforced cement concrete type B-1, 1:2:4 (using 20mm nominal size crushed and graded stone aggregate) in columns, posts, struts etc. complete in all respect as specifified and directed. |
| 47 | Providing and laying for reinforced cement concrete type B-1, 1:2:4 (using 20mm nominal size crushed and graded stone aggregate) in beams, lintels, etc.; complete in all respect as specifified and directed. |
| 48 | Providing and laying for reinforced cement concrete type B-1, 1:2:4 (using 20mm nominal size crushed and graded stone aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like ; complete in all respect as specifified and directed. |
| 49 | M & L PCC (1:2:4) type B-0 using 12.5 mm nominal size crushed and graded stone aggregate in coping, hold fasts or of similar items including necessary cutting, form work etc. complete in all respect as specified and directed. |
| 50 | M&L for precast Perforated RCC ,type B-1,1:2:4 (using 20 mm crushed and graded stone aggregate) as in manhole cover /cover slab or of similar type slab works,etc ,including formwork and loading/unloading of the same and fixed in position ,complete in all respect as specified and directed. |
| 51 | M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges, foundation, base concrete, hard standing etc complete all as specified and directed by Engineer-in-Charge |
| 52 | M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter in rough finished flat surface of concrete complete in all respect as specifified and directed. |
| 53 | M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions in rough finished flat surface of concrete complete in all respect as specifified and directed. |
| 54 | M & L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. in rough finished flat surface of concrete complete in all respect as specifified and directed. |
| 55 | M & L for formwork to soffits of suspended slabs as roof slabs, floor slabs, landings amd similar work not exceeding 200mm thick in rough finished surfaces of concrete complete in all respect as specified and directed. |
| 56 | M & L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n. exc. 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work in rough finished flat surface of concrete complete in all respect as specifified and directed. |
| 57 | M & L for deformed TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete in all respect as specifified and directed. |
| 58 | M & L for deformed TMT steel bars 5mm dia and over upto and including 10mm dia in stirrups, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete in all respect as specifified and directed. |
| 59 | M & L full brick work with Old Size Cement boned Bricks of class designation 75, straight or curved on plan exc. 6m mean radius built in CM (1:6) complete in all respect as specified and directed. |
| 60 | M & L brick work sub class B, class designation 75 old size bricks, straight or curved on plan exceeding 6 m mean radius built in CM 1:4 complete in all respect as specified and directed. |
| 61 | Supply only water proofing compound complete in all respect as specifified and directed. |
| 62 | S & F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; and similar work conforming to Fe. 290, Gde-E-165 complete in all respect as specifified and directed. |
| 63 | S & F of 1.6mm thk MS plate as in wall clading of steel gates with necessary arrangement and similar work complete all as specified and diretced. |
| 64 | S&F steel windows and ventilator with glazing bars, side hung shutters with projecting type hinges, including steel handle, and steel peg stay dovetailed or welded complete all as specified and directed. |
| 65 | Providing and laying for Reinforced cement concrete in coping, hold fasts using type B-1, 1:2:4 (using 20 mm nominal size crushed and graded stone aggregate) or of similar type of work including necessary formwork complete in all respect as specified and directed. |
| 66 | S & F of roof treatment with the following specification:-(a)Applying cement slurry over concrete surfaces @3kg/sqm. (b)Rendring 15mm thick in cement mortar (1:4) mixed with water proffing compound as per manufactures instruction on cleaned concrete surfaces of roof and finishing the surfaces fair and even including curing the plastered surfaces for 7 days by ponding of water over the roof, (leveling course).(c) Applying evenly one coat of cold bituminous primer conforming to [email protected] liter per square metre on the cleaned plastered surfaces(d) Applying evernly one coat of blown hot bitumen of grade 85/25@ 1.20 Kg per square metre on primed surfaces.(e) Applying a layer of APP based polymeric membrane, 3mm thick (minimum) weighing 3.50 Kg per square metre reinforces) with polyster non woven fabric wighing not less than 160 gms per square metre by torch application. The overlap shall be not less than 100mm on transverese direction and 75mm on longitudinal direction and sealing overlsaps.(f) Applying evenly one coat of aluminium paint @ 0.10 litre per square metre over the APP based polymeric membrane. |
| 67 | S & F of polythene film black 150micron |
| 68 | M&L for Sand filling under floors or in foundations including watering and consolidation complete in all respect as specified and directed. |
| 69 | M & L for two coat water based premium acrylic smooth exterior emulsion of approved colour with silicon additive and color stay Techonology, Excellent Dirt Pick up resistance with low VOC less than 50 gram/litre as per the LEEDS specifieecations, Anti Algal properties in two coats @ 1.79 ltr (Undiluted)/10 Sqm with water as per manufacturer instructions applied over priming coat with fully automatic airless spray machine of paint application with a flow spreed of min 1 ltr per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface in both coats of paint complete all as specified and directed.Note : (a) The work pertaining to periodical services and water proofing shall be executed as per manufacturer instructions i.e. Paint, Distemper, Putty etc is proposed to be used by the contractor and approved by Engr-in-Charge.(b) Cost of Scafolding upto 10 mtr height of building is included in this item. |
| 70 | M & L for waterproof cement based putty @ 1 Kg (undiluted) per sq mtr of average thickness 1mm over the newly plastered surfaces of wall to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanicsm) having RPM not less than 1500, sanding pad of 240 grit or above to make the surface free from dust etc by skilled labour as per following steps : -Step 1 : Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5 Kg putty per minute.Step 2 : Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a max pressure 3300 PSIStep 3 : Allow 6-8 hrs time to dry the putty surfaceNote : (a) The work pertaining to periodical services and water proofing shall be executed as per manufacturer instructions i.e. Paint, Distemper, Putty etc is proposed to be used by the contractor and approved by Engr-in-Charge.(b) Cost of Scafolding upto 10 mtr height of building is included in this item.(c) Masking of waindow/doors during spray painting using polythine film will be included (d) Cleaning and clearing site of paint, mats etc included. |
| 71 | M & L for waterproof cement based putty @ 1 Kg (undiluted) per sq mtr of average thickness 1mm over the newly plastered surfaces of ceiling to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanicsm) having RPM not less than 1500, sanding pad of 240 grit or above to make the surface free from dust etc by skilled labour as per following steps : -Step 1 : Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5 Kg putty per minute.Step 2 : Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a max pressure 3300 PSIStep 3 : Allow 6-8 hrs time to dry the putty surfaceNote : (a) The work pertaining to periodical services and water proofing shall be executed as per manufacturer instructions i.e. Paint, Distemper, Putty etc is proposed to be used by the contractor and approved by Engr-in-Charge.(b) Cost of Scafolding upto 10 mtr height of building is included in this item.(c) Masking of waindow/doors during spray painting using polythine film will be included (d) Cleaning and clearing site of paint, mats etc included. |
| 72 | S&F rolled section as in framing for door/vent/CB/chowkhats/water staging , wind tie and the like using angle, tee, hollow tubes etc., cleat and connecting plates complete (Butt hinges shall be measured and paid for separately) using Fe 410-W (Gde-E-250) quality \\"A\\" complete all as specified and directed. |
| 73 | M & L for applying Bitumastic gola, with 80/25 bitumen and coarse sand mixture. 1:3 by weight, at the junction of Perimeter of the building and every 3 mtr in the lateral dimension all as specified and directed. |
| 74 | S & F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 75mm bore including necessary MS pipe clamp complete in all respect as specified and directed. |
| 75 | M & L for extra forming fair finished drain or channel any girth in cement concrete using extra cement including forms, moulds mitred/stopped ends etc for 300mm girth .complete in all respect as specified and directed. |
| 76 | Taking down carefully (copper/aluminum) unsv point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point ,socket point or power point including fixture and fitting such as switches, ceiling roses, pendants , regulators , sockets, light fitting etc. removing material to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making good the disturbed surfaces of wall/floor or ceiling to match with existing surface and finishing the surfaces with distemper/white washing/colour washing as per existing complete all as specified and directed. |
| 77 | Taking down carefully by unscrewing from main switch boards/cut out boxes/MCB DBs / complete sealing the cable end and making good disturbed surface by walls etc. |
| 78 | Taking down ceiling fan of any type and size dismantling blades and keep in safe custody or deposite to MES store yard for refixing after completion of B/R work complete all as specified and as directed by Engineer-in-charge. |
| 79 | M & L for Point Wiring for one light point controlled by one switch with 1.5 Sqmm (Nominal Area) PVC insulated unsheathed fire retardant low smoke and halogen (FR-LSH) ,1100 Volts Grade Copper conductor single core multi stranded copper cable must conform to IS 14927 (Part 1 & 2): 2001 using approved colour code for phase and neutral as per IS code (Red Colour Cable for Phase and Black Colour Cable for Neutral), laid in and including PVC Casing and Capping size of casing and caping as per actual site requirement in accordance with clause No 19.125 of SSR Part I (ISI marked) with Accessories including 1.50 Sqmm PVC ins-ulated Stranded Cpper Conductor Cable (Green Colour) as Earth Continuity Conductor and connected to Common Earth Dolly or as directed and PVC terminal box (For normal/modular switch socket) with 1.2 mm thick PVC cover fixed on Wall for one light point controlled by one switch complete all as specified and directed by Engineer-in-charge. |
| 80 | Description all as per item No. 79 above but for ceiling fan / Exhaust fan point controlled by one 5 amp switch |
| 81 | Description all as per ser item No 79 but for 05 amp socket outlets point controlled by one switch on Independent board complete all as specified and directed. |
| 82 | Description all as per ser item No 79 but for 05 amp socket outlets point controlled by one switch on same board with other switches complete all as specified and directed. |
| 83 | Description all as per ser item No 79 but for 15 amp socket outlets point controlled by one switch on Independent socket outlet using 2.5 Sqmm PVC insulated and unsheathed fire retardant low smoke and halogen (FR-LSH) copper conductor single core multi stranded copper cable must conform to IS 14927 (Part 1 & 2): 2001 using approved colour code for phase and neutral as per IS code (Red Colour Cable for Phase and Black Colour Cable for Neutral), laid in and including PVC Casing and Capping size of casing and caping as per actual site requirement in accordance with clause No 19.125 of SSR Part I (ISI marked) with Accessories including 2.50 Sqmm PVC insulated Stranded Cpper Conductor Cable (Green Colour) as Earth Continuity Conductor and connected to Common Earth Dolly or as directed and PVC terminal box (For normal/modular switch socket) with 1.2 mm thick PVC cover fixed on Wall complete all as specified and directed by Engineer-in-charge. Please Enable Macros to View BoQ information |
| 84 | Description all as per ser item No 79 but for 15 amp socket outlets point controlled by one switch on Independent socket outlet using 2.5 Sqmm PVC insulated and unsheathed fire retardant low smoke and halogen (FR-LSH) copper conductor single core multi stranded copper cable must conform to IS 14927 (Part 1 & 2): 2001 using approved colour code for phase and neutral as per IS code (Red Colour Cable for Phase and Black Colour Cable for Neutral), laid in and including PVC Casing and Capping size of casing and caping as per actual site requirement in accordance with clause No 19.125 of SSR Part I (ISI marked) with Accessories including 2.50 Sqmm PVC insulated Stranded Cpper Conductor Cable (Green Colour) as Earth Continuity Conductor and connected to Common Earth Dolly or as directed and PVC terminal box (For normal/modular switch socket) with 1.2 mm thick PVC cover fixed on Wall complete all as specified and directed by Engineer-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender