Tender For Repair Maintenance Of Internal Electrification, Dg Set, Summer Appliances, Street / Security Lights And Allied Works At Chauhtan Hill Top Under Ge (Af) Utarlai
Tender Value
14.50 Lakhs
Estimated cost
Bid Submission
08 Aug 2026
18 days left
EMD
29000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Barmer → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair Maintenance Of Internal Electrification, Dg Set, Summer Appliances, Street / Security Lights And Allied Works At Chauhtan Hill Top Under Ge (Af) Utarlai
BOQ
| Sl. No. | Item Description |
| 1 | Supplying, fixing and testing in replacement of Street lights LED type 45W pressure die cast aluminium housing luminaires complete including taking down old u/s street light any type as directed by Engr-in-Charge. |
| 2 | Supplying, fixing and testing in replacement of Street lights LED type 60W pressure die cast aluminium housing luminaires complete including taking down old u/s street light any type as directed by Engr-in-Charge. |
| 3 | Supplying, fixing and testing in replacement of Flood lights LED type 120W pressure die cast aluminium housing luminaires complete including taking down old u/s street light any type as directed by Engr-in-Charge. |
| 4 | Decarburizing /cleaning complete LT 415 Volts 3 phase panel/ bus bar chamber with electrical connections, complete bus bar from the bus bar chamber, cleaning and ensure proper decarburizing, refixing the same after applying Backtol Red solution to the bus bar insulator & checking all the connections, tightening the nuts, bolts & thimbles of in-coming/out-going system complete incl replacement of defective rusted bolts & nuts all as specified and directed. |
| 5 | M&L for painting on out door/ indoor LT panels/Bus bar chamber, with removing rust by wire bushes, applying painting of panel surface of any description using synthetic enamel paint of two coats by using spray gun after preparation of old painted surfaces complete all as directed |
| 6 | Supply and fixing in replacement of MCCB 4 pole, 415 V, 160 Amps, 16 KA with thermal and magnetic releases including necessary modification in the panel complete including taking down old u/s MCCB any type all as specified and as directed. Make: Legrand/L&T/Havells/Indoasian |
| 7 | Supply and fixing in replacement of MCCB 4 pole, 415 V, 100 Amps, 16 KA with thermal and magnetic releases including necessary modification in the panel complete including taking down old u/s MCCB any type all as specified and as directed. Make: Legrand/L&T/Havells/Indoasian |
| 8 | Supply & Laying in replacement in trenches or fixing on wall or passing through pipe or in cable ducts, 1100 volts grade 3.5 core XLPE armoured, electric power cables (heavy duty) with aluminium conductor of the following size . Note: The rate quoted will be inclusive of termination at ends with suitable aluminium lugs wherever required and taking down old u/s cable any size and type. |
| 9 | 16 sqmm 4 core |
| 10 | 35 Sqmm 3.5 Core |
| 11 | Excavation in trenches not exceding 1.5m wide and not exceding 10.0 sq m on plan and not exceding 1.5m depth and getting out soft soil. |
| 12 | Returing filling in including spreding leveling watering and well ramming in layer not exceding 25 cm as in soil all as specified and dirceted. |
| 13 | Removing excavated material not exceding 50 m and depostingwhere directed at a level not exceding 1.5 m above the starting point. |
| 14 | M & L for sand cushioning all around the cable for protection by natural tibba sand |
| 15 | Supplying and Laying stone patti 40-50 mm thick, 25- 30 cm wide abutting each other for cable protection |
| 16 | Supplying, fixing and testing in replacement of Fos lighting guiding of ornate bollard & downward lamp 40 W including PCC block 300mmx300mmx150mm and connected items.Complete including taking down old u/s street light any type as directed by Engr-in-Charge. |
| 17 | Supplying, fixing and testing in replacement of lighting guiding of bollard 40 W including PCC block 300mmx300mmx150mm and connected items.Complete including taking down old u/s street light any type as directed by Engr-in-Charge. |
| 18 | Supplying, fixing and testing in replacement of LED polycarbonate cylindrical tube 10 W trim nxt panel LED light . complete including taking down old u/s street light any type as directed by Engr-in-Charge. |
| 19 | S&F Square shaped recess/suspended mounted environment friendly new generation asthetically ultra modern with high brightness LEDs as light source LED Flat panel, 36 watt, 2'x2'size, complete with driver and all accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable complete all as specified and directed. |
| 20 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.0 sq mm 2 core. |
| 21 | Supply, laying, fixing or passing through pole from junction box to street light connection, 1100 volts grade heavy duty cable with PVC solid insulated aluminium conductor served with an inner sheathing PVC tape and over all PVC sheathed 4 Sqmm 2 core nominal cross section complete all as specified and directed. |
| 22 | S&F 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 10 sqmm and overall PVC sheathed in service connections complete all as specified and directed. |
| 23 | S&F Post top energy saving , environmental friendly, aesthetically designed with indirect symmetrical light distributio, die-cast aluminium IP-65 luminaire with high power COB LED as light source of capacity 15/20 Watt, 6500K complete all as specified and as directed by Engr-in-charge. |
| 24 | S&F GI tubing 50mm bore medium grade, cut to pieces 1.5 mtr long for mounting of post top lantern independently at places or at top of gate/pillar and including grouting in PCC as per site requirement complete all as specified and directed. |
| 25 | Material and labour for repair of fire alarm panel to include burnt transformer, Ics, multi chips etc complete all as specified and directed. |
| 26 | Supply, Installation, Testing, Commissioning and replacement of Optical Smoke Sensor with Base LEDs for 360° Visibility, Advanced Detection and Communication Protocol, Sleek Low-profile Housing design, Regular 100 mm. base, IP 42, Smoke Sensitivity (1.96±0.76)% per ft., Air Velocity 0-400 fpm. EN54 Certified, 8 to 30 V DC Operating, Operating Temperature -30° to +70°C, including 12 V relay version complete all as speicied and directed. Make:Honeywell,SIMPLEX and Autronica. |
| 27 | Supply, Installation, Testing, Commissioning and replacement of Conventional Sounder, wall & ceiling mount, with back box, 24 V DC operation, Peizo electric type, Fire engine siren tone complete all as specified and directed. |
| 28 | S&F earthing pit identifier / marker for lightening arrester made of MS plate 6 mm thick oval size having major axis 30 cm & minor axis 20 cm mounted on 25 mm dia GI pipe medium grade project 60 cm above the ground and embeded suitably in concrete PCC 1:2:4 type B2 of size 20 cm x 20 cm x30 cm. The oval shape identifier & earthing pit cover shall be painted with two coat of synthetic enamel paint over a coat of primer and writing letter e.g. LA 1/10 on the plate and earth pit cover all as specified and directed by Engr-in-Charge. |
| 29 | Ditto as per item No.26 above but having tringular plate of base 30 cm & vertical height of 20 cm for equipment earthing pit and writing letters e.g. EQ 1/10 etc all as specified and directed by Engr-in-Charge |
| 30 | Ditto all as per item No. 26 above but having rectangular plate of length 30 cm & width 20 cm for power supply earth and writing letters e.g. PS 1/10 etc all as specified and directed by Engr-in-Charge.(Note for item No. 18 to 21 : The cover plate of earth pit and MS plate is to be painted with colour code of the type of earthing pit for Chemical earthing pit RED colour and for conventional earthing pit YELLOW colur and writing letters on plate and cover of pit in BLACK colour. The detail guidelines has been incorporated in the particular specification. Contractor to quote their rate accordingly |
| 31 | S&F repairs Air Termination Single Pointed Aluminium Rod 12 mm dia and up to 300 mm long with Arrester Clamp 12mm made out of Brass/ Gun Metal including provision of Cement Concrete 1:2:4 (20mm graded stone aggregate) Block 300x300x300mm (and necessary Fixing Arrangement at Roof all Joints should be connected by Exothermic Welding or Brazing including taking down unserviceable Air Termination, complete all as specified and as directed. |
| 32 | S&F Test Point Terminal Block made of Gun Metal or Phosphorus Bronze size 75x75x 25mm, drilled and screwed including 3 No. 8mm dia, 25mm long hexagonal Head Screw including taking down/out unserviceable Test Point Terminal Block, complete all as per specified and as directed. |
| 33 | S&F in repair replacement Earthing funnel of 20 mm dia with wire -mesh all as specified as directed |
| 34 | S&F repairs Aluminium Strip 25 x3 mm with Saddles and fixing Screws for Roof/ Earth Conductors and Down Conductors above Ground all Joints should be connected by Exothermic Welding or Brazing including taking down unserviceable Strip, complete all as specified and as directed.NOTE : All Joints should be joined by Brazing / by using of nuts and bolts |
| 35 | S&F repairs Copper Strip 20x3.mm with Saddles and fixing Screws for Roof/ Earth Conductors and Down Conductors above Ground including taking down unserviceable Strip, complete all as specified and as directed.NOTE : All Joints should be joined by Brazing / by using of nuts and bolts |
| 36 | S&F repairs Galvanised Iron Strip 32x6mm with Saddles and fixing Screws for Roof/Earth Conductors and Down Conductors above Ground including taking down unserviceable Strip, complete all as specified and as directed.NOTE : All Joints should be joined by Brazing / by using of nuts and bolts |
| 37 | S&F Galvanised Iron Tubing/Pipe 40mm bore (dia), light grade for Strip Protection, fixed in Walls/Floors with suitable type of Clamps, etc. including taking down unserviceable GI Tubing/Pipe, complete all as specified and as directed. |
| 38 | M&L inrepair replacement for insulator(saddle) porcelain for carrying earthing strip |
| 39 | M & L Earthing complete with copper earth electrode 60×60cm ×3.15mm burried directly in ground vertically to depth not less than 2.25 m below normal ground level with top edge of the earth plate at a depth not less than 1.5 m below ground level connected to and including copper strip of size 20x3 mm by means of nut, bolt, check nut and washer etc made of copper alloy and connection to test point and earth dolly all as shown in electrical plate No. 3 SSR Part I 2009 and specified or indicated including excavation and earth work in any type of soil, (in any type of strata ) PCC type C1 chamber , cast iron chamber frame & cast iron pit cover , heavy duty funnel all as directed , GI Pipe 15 mm bore medium grade for watering and 40 mm bore GI Pipe middium grade for protection and test point complete Note:-(i) Copper strip 20 x 3 mm upto 7.5 mtr length shall be deemed to include in this items rate.(ii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost by the contractor. |
| 40 | Earthing complete with G I earth plate electrode 600 mm x 600 mm x 6 mm burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to G I earth strip 32 x 6 mm size by means of brass bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 15 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC type C1 chamber , cast iron chamber frame & cast iron pit cover , heavy duty funnel all as directed . Note: The unit rate includes earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point. |
| 41 | M&L for monthly 'A' Check Inspection of DG sets of capacities as described in Ser Item No. 2.00 to 25.00 including alternator, electric panel board connection to DG set etc for smooth functioning and carrying out maintanance as required at site and directed by Engr-in Charge. Note: Items/ Spares required shall be measured and paid separately under respective item of BoQ(i) Checking engine oil level and topping up as and when required. (ii) Checking and adjusting the belt for tension and replacement of belt if required.(iii) Checking of oil bath air cleaner level(iv)Checking of exhaust system for leakage(v) Draining of sediment from fuel filter and fuel tank(vi) Cleaning of air cleaner elements(vii) Checking engine alternator coupling, mounting bolts and alignment(viii) Tighting all nuts, bolts, in altenator terminal block(ix) Checking of alternator carbon brushes and connections in alternator(x) Checking and tightening of all connection in DC control wiring.(xi) Checking of all radiator rubber hoses for leakage and replacement if required.(xii) Checking and recording oil pressure, water and oil temperarute for smooth functioning.(xiii) Checking anti vibration mounting pads for any deformation.(xiv) Checking throttle linkage for smooth operation.(xv) Checking battery for cell test, electrolyte level, gravity and topping up to required level(xvi) Routine check / repair work of panel, switches, MCCBs, main switch, all contactors, engine control unit etc.(xvii) Checking of AMF panel, all electrical connections etc.(xviii) Checking of earthing resistance(xix) Cleaning of vegitation around the DG set up to 1.5 mtr area.(xx) 'A' Check Service shall be carried out as described in ser No. 2.00 to 25.00 |
| 42 | 320 KVA Capacity, Make : Cummins, Location : Chauhtan Hill Top |
| 43 | 100 KVA Capacity, Make : Ashok Layland, Location : Chautan Base |
| 44 | 15 KVA Capacity, Make : Cummins, Location : Chauhtan Base |
| 45 | M&L for 'B' Check once in Six month OR 250 Hrs running whichever is earlier DG sets of capacities as mentioned under respective item of BOQ, inspection, maintenance and serviceing including alternator, electric panel board connection to DG set etc for smooth functioning and carrying out maintenance as per OEM instructions and as directed by Engr-in-Charge. Note: (i) 'B' Check Service shall be carried out as described in respective item of BOQ (ii) Items/ Spares including 'B' Check kit, coolent, lubricating oil required shall be measured and paid separately under respective item of BoQ(i) Repeat the activities of 'Á' Check services(ii) Replacment of lubricant oil. (iii) Replacing lubricant oil filters element with O rings(iv) Replacing fuel filters element with O rings(v) Replacing air filter elements with O rings(vi) Replacing coolant. |
| 46 | 320 KVA Capacity, Location : Hill Top |
| 47 | 100 KVA Capacity, Location : Base |
| 48 | 15 KVA Capacity, Location : Base |
| 49 | Supply only 'B' check kit for DG set of following capacities as mentioned in respective item of BOQ.Note : It includes oil filters (1.00 Ltr/0.5 ltr), Diesel filters and air filters inner and outer as recommended by OEM |
| 50 | 320 KVA Capacity, Location : Hill Top |
| 51 | 100 KVA Capacity, Location : Base |
| 52 | 15 KVA Capacity, Location : Base |
| 53 | Supply only coolent, K cool super plus 50-50 Premix |
| 54 | Supply only Battery water with electrolyte mix |
| 55 | Supply only Engine oil 15 W 40 turbo synthetic superior quality engine oil |
| 56 | Supply only radiator hose pipe set with clamps suitable for DG set of capacity 15 KVA |
| 57 | Supply only radiator hose pipe set with clamps suitable for DG set of capacity 100 KVA |
| 58 | Supply only fan belt set suitable for 15 KVA |
| 59 | Supply only fan belt set suitable for 100 KVA |
| 60 | Supply only fan belt set suitable for 320 KVA Please Enable Macros to View BoQ information |
| 61 | Supply only fan belt set suitable for 320 KVA Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysAug 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender