Defence Statutory Bodies & Commissions/Committees Closing in 25 days TDR #56531737

Tender For Repair And Maintenance Of Internal Electrification And Rewiring , Led Fittings, Ceiling Fan, Exhaust Fan And Geyser At Sma And High Rise Bldg At Site A3 Naval Base Karwar.

Issued by Statutory Bodies & Commissions/Committees · Uttara Kannada, Karnataka
Tender Value
75 Lakhs
Estimated cost
Bid Submission
14 Aug 2026
25 days left
EMD
1.37 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Uttara Kannada → Karnataka
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of Internal Electrification And Rewiring , Led Fittings, Ceiling Fan, Exhaust Fan And Geyser At Sma And High Rise Bldg At Site A3 Naval Base Karwar.

BOQ

Name of Work:- REPAIR AND MAINTENANCE OF INTERNAL ELECTRIFICATION AND REWIRING , LED FITTINGS, CEILING FAN, EXHAUST FAN AND GEYSER AT SMA AND HIGH RISE BLDG AT SITE A3 NAVAL BASE KARWAR.
Sl. No. Item Description
1Rectifying the defects in domestic fluroscent tube/CFL light fittings any type and at any height, ceiling rose, electric bell by tightening loose connections and rectifying defects, testing complete all as specified and directed.
2Opening switch mounting plate at normal height upto 1.5 meter, rectifying the defects in fittings and fixtures such as switches, bell push, fan regulator, sockets etc by tightening loose connections, refixing switch plate and testing complete all as directed.
3Note for Item No 1 & 2 :- The unit rate quoted shall be deemed to be included the elements of labour only for rectifying and making the fitting and fixtures functional. If replacement of parts/items is required to make the fittings functional, the cost for labour and material for the same will be measured and paid for as \\"S&F in repairs\\" under relevant items of this schedule hereinafter and in such cases the above items will not be measured and paid for.
4Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
5M&L for surface point wiring 1100 Volts grade 1.5 Sqmm PVC insulated FRLS sheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking in and including PVC casing & caping medium grade with all accessories in wall/ceiling /floor/roof etc, sunk pressed steel or cast iron terminal boxes with 3mm thick plastic laminated sheet top cover including 1.5 Sqmm PVC insulated FRLS sheathed 1100 Volts multistranded copper conductor conforming to IS:694:1990 with ISI marking as continuous earth wire connected to common earth dolly all as specified and directed for the following:-
6(a) One light/fan point controlled by one switch
7(b) One 3 pin socket outlet 5 Amp on same board with other switches.
8(c) One 3 pin socket outlet 5 Amp on independent board.
9(d) One bell point controlled by one push button on the same board with other switches or independent with cables of 1.5 Sqmm size.
10M&L for point wiring with 2.5 Sqmm PVC (FRLS) insulated sheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 2.5 Sqmm PVC (FRLS) insulated sheathed multi stranded copper conductor cable draw in PVC casing caping including CI/MS/ PVC sunk boxes for mounting of 3 pin modular switch socket outlet 15/20 Amp on independent board with frame plate sheet cover of adequate size and making good disturbed surfaces with CM (1:4) to match with the existing surface complete all as specified and directed by Engr-in-Charge.
11M&L for point wiring with 4 Sqmm PVC (FRLS) insulated sheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 4 Sqmm PVC (FRLS) insulated sheathed multi stranded copper conductor cable draw in PVC casing caping including CI/MS/ PVC sunk boxes for mounting of 3 pin socket outlet 15 Amp on independent board with frame plate sheet cover of adequate size and making good disturbed surfaces with CM (1:4) to match with the existing surface complete all as specified and directed by Engr-in-Charge.
12M&L for point wiring with 1.5 Sqmm PVC (FRLS) insulated sheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 1.5 Sqmm PVC (FRLS) insulated sheathed multi stranded copper conductor cable draw in existing conduit complete all as specified and directed by Engr-in-Charge for the following
13(a) One light/fan point controlled by one switch
14(b) One 3 pin socket outlet 5 Amp on same board with other switches.
15(c) One 3 pin socket outlet 5 Amp on independent board..
16(d) One bell point controlled by one push button on the same board with other switches or independent with cables of 1.5 Sqmm size.
17M&L for point wiring with 2.5 Sqmm PVC (FRLS) insulated sheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 2.5 Sqmm PVC (FRLS) insulated sheathed multi stranded copper conductor cable draw in existing conduit complete all as specified and directed by Engr-in-Charge for one 3 pin socket outlet 15 Amps on Independent board
18M&L for point wiring with 4 Sqmm PVC (FRLS) insulated sheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 4 Sqmm PVC (FRLS) insulated sheathed multi stranded copper conductor cable draw in existing conduit complete all as specified and directed by Engr-in-Charge for one 3 pin socket outlet 15 Amps on Independent board
19Taking down submain wiring cable of any size/type alongwith earth wire with or without concealed/surface conduit/casing caping complete all as specified and directed.
20M&L sub main wiring with proper colour coding, FRLS PVC insulated copper conductor, sheated, multi-stranded, copper conductor, cable of two runs, 6 Sqmm for phase and neutral and one run of 6 Sqmm for earth wire, drawn through and including PVC casing and caping with all fittings like tee, bends, junction box/terminal box fixed on wall/ground/ceiling etc and connected complete all as specified and directed by Engr-in-Charge. (Note :- Phase should be of Red/Yellow/Blue, neutral should be of black and earthing wire should be of green colour. Two run of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length).
21M&L sub main wiring with proper colour coding, FRLS PVC insulated copper conductor, sheated, multi-stranded, copper conductor, cable of two runs, 4 Sqmm for phase and neutral and one run of 4 Sqmm for earth wire, drawn through and including PVC casing and caping with all fittings like tee, bends, junction box/terminal box fixed on wall/ground/ceiling etc and connected complete all as specified and directed by Engr-in-Charge. (Note :- Phase should be of Red/Yellow/Blue, neutral should be of black and earthing wire should be of green colour. Two run of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length).
22M&L sub main wiring with proper colour coding, FRLS PVC insulated copper conductor, unsheated, multi-stranded, copper conductor, cable of two runs, 6 Sqmm for phase and neutral and one run of 6 Sqmm for earth wire, drawn through existing conduit and junction box fixed in wall/ceiling etc and connected complete all as specified and directed by Engr-in-Charge. (Note:- Phase should be of Red/Yellow/Blue, neutral should be of black and earthing wire should be of green colour. Two run of cable for phase/neutral and one run of cable for earth will be measured and pais as one unit length).
23M&L sub main wiring with proper colour coding, FRLS PVC insulated copper conductor, unsheated, multi-stranded, copper conductor, cable of two runs, 4 Sqmm for phase and neutral and one run of 4 Sqmm for earth wire, drawn through existing conduit and junction box fixed in wall/ceiling etc and connected complete all as specified and directed by Engr-in-Charge. (Note:- Phase should be of Red/Yellow/Blue, neutral should be of black and earthing wire should be of green colour. Two run of cable for phase/neutral and one run of cable for earth will be measured and pais as one unit length).
24S&F in repairs MCB DB SPN, 12 way, 240 Volt, double door powder coated sheet steel enclosure for surface mounting fitted with 200 Amps bus bar and din channel complete all as specified and directed.
25S&F in repairs MCB DB SPN, 8 way, 240 Volt, double door powder coated sheet steel enclosure for surface mounting fitted with 200 Amps bus bar and din channel complete all as specified and directed.
26S&F in repairs MCB DB SPN, 18 way, 240 Volt, double door powder coated sheet steel enclosure for surface mounting fitted with 200 Amps bus bar and din channel complete all as specified and directed.
27S&F in repairs MCB TPN, 16 to 32 Amps, ''C'' series 415 Volts, 3 phase, 10 KA breaking capacity of complete all as specified and directed.
28S&F in repairs MCB TPN, 40 to 100 Amps, ''C'' series 415 Volts, 3 phase, 10 KA breaking capacity of complete all as specified and directed.
29S&F in repairs MCB SPN, 6 to 32 Amps, ''C'' series 230 Volts, single phase, 10 KA breaking capacity complete all as specified and directed.
30S&F in repairs MCB SP, 5 to 32 Amps, ''C'' series 230 Volts, single phase, 10 KA breaking capacity complete all as specified and directed.
31Supply and fixing in repair RCBO Double pole and Neutral 40 Amp ,30mA capacity C series 230 Volt Complete all as specified and directed
32S&F in repairs switch piano 5 Amps one way flush type complete all as specified and directed.
33S&F in repairs switch piano 5 Amps two way flush type, complete all as specified and directed.
34S&F in repairs socket outlet 2 in 1, 5 pin, 5 Amps flush type, complete all as specified and directed.
35S&F in repairs switch piano 15 Amps one way flush type complete all as specified and directed.
36S&F in repairs socket outlet 2 in 1, 3 pin, 5 and 15 Amps flush type complete all as specified and directed.
37S&F in repairs switch socket combination 3 pin, 16 Amp, flush type universal complete all as specified and directed.
38S&F in repairs ceiling fan regulator electronic five step type 230 Volts single phase complete all as specified and directed.
39S&F in repairs bell push 5 Amps 230 volts AC, single pole complete all as specified and directed
40S&F in repairs bell electric (ding dong bell) 230 volts AC, single phase complete all as specified and directed.
41S&F in repairs lamp holder, PVC/polycarbonate type with back plate complete all as specified and directed.
42Dismantling of ceiling fan and painting the same with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins, reinstalling the same as required complete all as specified and as directed
43Supply and fix in repair of PVC/Polycarbonate type Plate white colour any size as per requirement of with cutting for switch and socket and regulator as per requirement complete all as specified and directed.
44S&F in repair ceiling rose surface bakelite 65 x 50 mm three terminal on and including PVC junction box of suitable size complete all as specified and directed.
45S&F in repairs decorative modular switch 6 Amps single pole one way flush type complete all as specified and directed.
46S&F in repairs decorative modular switch 6 Amps single pole two way flush type complete all as specified and directed.
47S&F in repairs decorative modular socket 6 Amps, 3 pin, flush type, multipurpose complete all as specified and directed.
48S&F in repairs decorative modular switch 16 Amps single pole one way flush type complete all as specified and directed.
49S&F in repairs decorative modular twin socket 16 Amps, 3 pin, flush type, multipurpose type complete all as specified and directed.
50S&F in repair decorative modular ceiling fan regulator electronic five step type 230 Volts single phase(2 module ) complete all as specified and directed.
51S&F in repairs moduler bell push with indicator 10 Amps 1 module type complete all as specified and directed
52S&F in repairs decorative modular Power switch 32 Amp DP 1 way switch with indicator 2 module type flush type complete all as specified and directed.
53S & F switch socket combination 2 in 1, 3 pin, 5 Amps Box type all as specified and directed by Engr-in-Charge all as specified
54S & F switch socket combination 2 in 1, 3 pin, 5 and 15 Amps Box type all as specified and directed by Engr-in-Charge all as specified
55S&F in repairs of following sizes front plate with base frame for fixing decorative modular switches/ sockets/ regulators etc and matching with existing complete all as specified and directed :-
56(a) 2 module
57(b) 3 module
58(c) 4 module
59(d) 6 module
60(e) 8 module
61S&F in repairs 5 watt LED light fittings 1 feet including making necessary connection complete all as specified and directed. Note : Contractor shall submit original manufacturers certificte for replacement warranty of 2 years, stating defective light &fittings shall be replaced without any extra cost during the warranty period of 2 years from the date of completion of the work
62Supply and fixing in repair round shape 6 watt 220 volts AC recessed type with high efficiency (with min efficiency of 130 lm/W) PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer in charge.Note : Contractor shall submit original manufacturers certificte for replacement warranty of 2 years, stating defective light &fittings shall be replaced without any extra cost during the warranty period of 2 years from the date of completion of the work
63S & F in repair 20 Watt ultra bright glass LED Tube Rod of size 4 ft all with miniumum efficiency of 130 lm/ Was specified and directed .Note : Contractor shall submit original manufacturers certificte for replacement warranty of 2 years, stating defective light &fittings shall be replaced without any extra cost during the warranty period of 2 years from the date of completion of the work
64S & F in repairs surface and wall mounted Regal Batten with including LED Tubelight with integral LED driver available connection energy efficient 22 W LED (four feet) with minimum efficiency of 130 lm/W complete in all respect including taking down old conventional type tube light fitting Note : Contractor shall submit original manufacturers certificte for replacement warranty of 2 years, stating defective light &fittings shall be replaced without any extra cost during the warranty period of 2 years from the date of completion of the work
65S& F wall mounted extruded PVC housing high quality indoor batten LED tube 20 watt colour temperature 6500 K (4' long) lumen 2000 - 3000, PF> 0.9, THD less 10% diffused connecting with three core flexible copper wire from connecton to ceiling rose/angle holder as per existing site requirement including taking down old conventional type tube light fitting as directed by Engr-in-charge. Note : Contractor shall submit original manufacturers certificte for replacement warranty of 2 years, stating defective light &fittings shall be replaced without any extra cost during the warranty period of 2 years from the date of completion of the work
66S&F in repair 10 watt LED tubelight fittings 2 feet lumen 1000 - 1500, including making necessary connection complete all as specified and directed. Note : Contractor shall submit original manufacturers certificte for replacement warranty of 2 years, stating defective light &fittings shall be replaced without any extra cost during the warranty period of 2 years from the date of completion of the work
67S& F in repair LED Bulkhead 10 Watt Luminarie with opal diffuser ,equipped with 2 Kv in built surge Protection with IP65 Protecting and minimum efficiency of 130 lm/ W complete with all as specified and directed.Note : Contractor shall submit original manufacturers certificte for replacement warranty of 2 years, stating defective light &fittings shall be replaced without any extra cost during the warranty period of 2 years from the date of completion of the work
68S & F in repairs Single pole and neutral enclosure with a metal two pin and earth plug and metal clad socket complete with one single pole MCB 20 Amps
69Taking down ceiling fan/exhaust fan of any sweep, dismantling, replacing defective part, overhauling, cleaning, greasing, rewinding etc and hanging up/fixing back in the original position, connecting up and testing complete all as directed.Note : (a) The unit rate quoted shall deemed to be included for minor items viz nuts, bolts split pin and rubber wheel etc. (b) Capacitor & bearing shall be measured and sperately under ser item Nos 56 , 57 & 58 here-in-after.(c) Rewinding of fan will be measured and paid for separately under ser item Nos 59 & 60 here-in-after.
70S&F in repairs capacitor of 2.5 mfd for ceiling fan and exhaust fan complete all as specified and directed.
71S&F in repairs bearing suitable for exhaust fan complete all as specified and directed.
72S&F in repairs bearing suitable for ceiling fan complete all as specified and directed.
73M&L for removing of burnt out copper winding wire from ceiling fan of any make and size of 1200 mm to 1400 mm sweep including cleaning of slots etc and rewinding with super enameled copper winding wire as per existing size/gauge including insulating material, varnishing and drying complete all as specified and directed.
74M&L for removing of burnt out copper winding wire from exhaust fan of any make and size of 300 mm sweep including cleaning of slots etc and rewinding with super enameled copper winding wire as per existing size/gauge including insulating material, varnishing and drying complete all as specified and directed.
75Repair only energy meter 230/415 volt, 10-25 Amp including making incoming and outgoing electric connection and testing including taking down old defective energy meter and depositing the same to MES store yard complete all as specified and directed.
76S&F in repair ventilator fan AC single phase 230 V of size 200 mm (PVC body) with louvers shutter (white/Ivory) and connected with flexible cord of size 23/0/0076 stranded copper conductor PVC insulated of length not less than 0.7m complete all as specified and directed. Note : Old unserviceable exhaust fan will be deposited in MES store by the contractor.
77S&F in repair exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300 mm complete all as specified and directed.Note : Old unserviceable exhaust fan will be deposited in MES store by the contractor.
78S&F in repairs heating element 1.5 KW of storage type water heaters (geyser) embedded type nickel plated duly mineral filled, ISI Marked complete all as specified and directed.
79S&F in repairs heating element 2.0 KW of storage type water heaters (geyser) embedded type nickel plated duly mineral filled, ISI Marked complete all as specified and directed.
80S&F in repairs thermostat adjustable between 30 degree C to 85 degree C for geyser complete all as specified and directed.
81S & F in repairs of PVC pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 60 cm long for cold water connection all as specified and directed by Engineer-in-charge.
82S & F in repairs metal braided PVC/CP pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 60 CM long for hot water connection all as specified and directed by Engineer-in-charge.
83S & F in repairs, non return valve 15 mm dia of brass, ISI marked all as specified and directed by Engineer-in-charge.
84S & F for stop valve , cast copper alloy screw down high pressure crutch handle, screwed both end for iron pipe suitable for 15 mm borecomplete all as specified and as directed.
85M&L for earthing complete with galvanized cast iron earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level ) with top edge of earth plate not less than 1.5 Mtr below normal ground level connected to galvanized earth lead 4 mm dia by means of bolts, nuts washers and check nuts of steel/GI duly protected with 15mm bore light grade pipe upto main board, 20mm bore watering pipe light grade with CI/MS funnel and wire mesh including excavation, earth work in any type of soil and removing the surplus soil to a distance not exceeding 50 Mtr, char coal dust and common salt in adequate qty all as shown in electrical plate No 3 of SSR Part-I 2009 having pit and cover in PCC 1:2:4 type B-1 including angle iron frame made of angle iron of size 40x40x6mm grouted in PCC pit for PCC cover, funnel with wire mesh complete and all as specified.Note :- The unit rate quoted shall be deemed to include for necessary excavation and earth work, PCC 1:3:6 type CI chamber, funnel with GI medium grade watering pipe 15mm bore, RCC cover slabs 50mm thick with 8mm dia CTD bars @ 140mm c/c both ways etc complete.
86S&F in repairs decorative, wall mounting, brushed nickel finish fixture with Opal Glass diffuser suitable with 9 W LED lamp B22 base including 9W lamp complete all as specified and directed.Note : Contractor shall submit original manufacturers certificte for replacement warranty of 2 years, stating defective light &fittings shall be replaced without any extra cost during the warranty period of 2 years from the date of completion of the work
87Supply ,fix and complete installation in repair of CPRI approved wall mounted, powder coated, Indoor LT panel of 63 Amps capacity with provision of six single phase energy meter,IP 44 standard including aluminium bus bar ,01 No 63 Amps incomer TPN complete all as specified and directed.Outer shell shall be made of 2.00 mm CRCA sheet.Incoming1-63 Amps TPN,1 Nos.2 Red Indicating Lamp with integrated LED Voltage: 230V AC-1 Nos.3 Yellow Indicating Lamp with integrated LED Voltage: 230V AC-1 Nos.4 Blue Indicating Lamp with integrated LED Voltage: 230V AC-1 Nos.6-Multifunction Meter (LCD display), 3Ph, Parameters: V, A, F, meter7- 32A Neutral Link, Channel Mounting, Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56531737
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 75 Lakhs
LAST DATE 14-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair And Maintenance Of Internal Electrification And Rewiring , Led Fittings, Ceiling Fan, Exhaust Fan And Geyser At Sma And High Rise Bldg At Site A3 Naval Base Karwar.
Basic Detail
Tender No 86130/E8
Bidding Type Tender
Location
City Uttara Kannada
State Karnataka
Key Dates
Publish Date 17 Jul 2026
Submission Date 14 Aug 2026
Open Date 17 Aug 2026
Finance
Tender Value 75 Lakhs
Tender Fee 1000
EMD 1.37 Lakhs
Exemption Available
Document List
86130TENDER.pdf
BOQ_872918.xls
c06497e8-dc1c-4150-a4de-6d306020ebd9.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 25 days
Aug 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 28 days

Tender Documents

Download All (ZIP) ↓
pdf

86130TENDER.pdf

xls

BOQ_872918.xls

html

c06497e8-dc1c-4150-a4de-6d306020ebd9.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender