Tender For Repair / Maintenance Of Rmus, Vcbs, Ht Feeders And Joint Kits Cable And Other Allied Work Under Ge (Mcte) Mhow.
Tender Value
40 Lakhs
Estimated cost
Bid Submission
08 Aug 2026
19 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Indore → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair / Maintenance Of Rmus, Vcbs, Ht Feeders And Joint Kits Cable And Other Allied Work Under Ge (Mcte) Mhow.
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exc. 1.5 mtr wide and not exc 1.5 mtr deep in hard dense soil for cables, stay etc and getting out complete all as specified and directed. |
| 2 | Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed. |
| 3 | Removing surplus excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 4 | Material and labour for approved river sand cushioning for under ground cable in trenches 8 cm before laying and 15 cm after laying of cable and punned thickness of sand shall be measured and paid for 18 cm only after punned/consolidated thickness complete all as specified and directed. |
| 5 | Supplying and laying un-reinforced precast concrete cable cover, class HV, Type-1, flat, size 300mm x 180mm x 40mm, ISI marked, laid flat across the cable length complete all as specified and directed. |
| 6 | S&F GI tubing, light grade, ISI marked 100 mm bore pipe laid in trenches/duct or in road crossing or fixed to wall/poles for protection of cable incl taking out old pipe of any grade complete all as specified and directed. |
| 7 | Supply and fix cable jointing kit for 11 KV grade (E) cable for indoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm complete all as specified and directed.Make : 3 M/Densil/M seal |
| 8 | All as per Item No.07, above, but for cable 120 to 185 sqmm. |
| 9 | All as per Item No.07, above, but for cable 240 to 300 sqmm. |
| 10 | Supply and fix cable jointing kit for 11 KV grade (E) cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 50 to 95 sq mm complete all as specified and directed. |
| 11 | All as per Item No.10, above, but for cable 120 to 185 sqmm. |
| 12 | All as per Item No.07, above, but for cable 240 to 300 sqmm. |
| 13 | Supply and fixing cable jointing kit for 11 KV (E) grade cable for straight through heat shrinkable type joint complete with jointing material and accessories suitable for 3 core 50 to 95 sqmm XLPE armoured aluminium conductor complete all as specified and directed. |
| 14 | All as per Item No.13, above, but for cable 120 to 185 sqmm. |
| 15 | All as per Item No.13, above, but for cable 240 to 400 sqmm. |
| 16 | Supply & fix in replacement of over current and earth fault relay model No MC61A as per existing site complete all as specified and directed. |
| 17 | M&L for providing under ground boring using mechanical pneumatic drilling equipment / manually for passing electric cables through by providing HDPE pipe of 100mm dia heavy quality, pressure rating 6 kg/cm2 under the existing bituminous/WBM road/PCC hard standings, depth range not more than 1.5mtr deep and making good the distrubed surfaces is to match with its existing specifications complete all as specified and directed.Note : Any damage to be done in existing cables/water pipes/structures shall be made good by the contractor at his own expense. |
| 18 | Dehydration of HV/EHV grade transformer oil minimum three cycles to achieve di electric strength not less than 40 KV for 1 minute with 2.5mm Gap as per IS - 335 - 1983 for EHV grade including topping up with new transformer oil complete all as specified and directed.Note :- (i) Centrifuging Machine with all T&P & testing machine of oil, required for dehydration shall be arranged by contractor.(ii) Oil required for topping up the transformer will be measured & paid separately |
| 19 | Supply and filling (topping up) of transformer oil EHV as per IS 335 of 1983 Part II after dehydration & testing complete all as specified and directed. |
| 20 | Taking down carefully old rusted / damaged switch air break, gang operated any type and size complete all as specified and directed. |
| 21 | Supply,installing in repairs, connecting and commissioning switch air break gang operated triple pole for current rating 200 Amp at 11 KV, out door type , mechanically operated, mounted on insulators with 9 insulator and steel frame, with operating mechanism and operating rod of 25mm bore GI pipe medium grade from ground level, with locking arrangements, complete all as specified and directed. |
| 22 | Supply and install in repairs HT 33KV horizontal type isolator(disconnector switch) outdoor type complete with current carring capacity 630 Amp with suitable GI pipe pipe medium grade required for operation, complete all as specified and directed. Please Enable Macros to View BoQ information |
| 23 | Supply and install in repairs HT 33KV horizontal type isolator(disconnector switch) outdoor type complete with current carring capacity 630 Amp with suitable GI pipe pipe medium grade required for operation, complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysAug 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender