Tender For Repair/Maint Of Summer Appliances Like Split Window Acs, Water Cooler, Refrigerator, Voltage Stabilizer Under Ge (Nw), Vasco
Tender Value
95 Lakhs
Estimated cost
Bid Submission
14 Aug 2026
26 days left
EMD
1.67 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maint Of Summer Appliances Like Split Window Acs, Water Cooler, Refrigerator, Voltage Stabilizer Under Ge (Nw), Vasco
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully indoor/outdoor unit of Split type ACs and window type AC of capacity 1.5 Ton/ 2 Ton capacity, servicing (Wet and Dry service will be done) complete as per site requirement, reinstallation of the same at existing position/location all as directed. NOTE :- The Service inclusive the following :- (i) Wash the filter with clean water, cleaning all the sides gently, wash out accumulated dust and lint/fabric with water. (ii) Clean the front grill with a clean cloth gently, damp with mild liquid dish washing detergent.(iii) Clean the cabinet by using mild soap or detergent and warm water. (iv) Electric/electronic items found defective during servicing will be executed, measured and paid separately under relevant item of this schedule . |
| 2 | Taking down Split type ACs (Outdoor unit only) / window type ACs unit of any capacity complete removal of existing paint including scraping the old faded paint and applying one coat of synthetic enamel paint by using sprayer and refixing the ACs in position, giving necessary electric connection and testing including replacement of worn out bolts, nuts etc. complete all as directed. |
| 3 | Supply and charging of refrigerant gas M -22/R-410a any type of refrigerant gas as per existing type upto sufficient required pressure for 1.5 TR/ 2 TR window type AC/Split type ACs including connected works like cutting of copper tubing incl brazing and refixing in position complete all as directed.(Note : Each filling will be measured and paid seperately) |
| 4 | Supply and charging of refrigerant gas R-32 / R-407 any type of refrigerant gas as per existing type upto sufficient required pressure for 1.5 TR/ 2 TR window type AC/Split type ACs including connected works like cutting of copper tubing incl brazing and refixing in position complete all as directed.(Note : Each filling will be measured and paid seperately) |
| 5 | Supply and charging of refrigerant gas R-410a any type of refrigerant gas as per existing type upto sufficient required pressure for 4 TR tower AC / 8 TR ductable AC including connected works like cutting of copper tubing incl brazing and refixing in position complete all as directed.. |
| 6 | Supply and fix factory sealed brand new sealed reciprocating/Rotating compressor unit of 1.5 TR of existing make & model including Dismantling carefully and removing of old unserviceable sealed compressor‘s unit of 1.5 ton capacity for window type/ split type AC's complete all as directed. ( Note: Sealed unit shall be purcased/procured from authorised dealers / agents of the manufacturer) |
| 7 | Supply and fix factory sealed brand new sealed reciprocating/Rotating compressor unit of 2 TR of existing make & model including Dismantling carefully and removing of old unserviceable sealed compressor‘s unit of 2 ton capacity for window type/ split type AC's complete all as directed. ( Note: Sealed unit shall be purcased/procured from authorised dealers / agents of the manufacturer) |
| 8 | S & F in repairs front cover grill , suitable for any type / model / make of split/window type room AC's of capacity 1.5 Ton / 2 Ton complete all as specified and directed. |
| 9 | Dismantling and removing defective blower motor single phase, 220V, 50Hz, from 1.5 / 2 Ton capacity Split/Window type AC and Supply and fixed brand new motor as per existing model/pattern and testing complete all as specified and directed. |
| 10 | Dismantling and removing defective unserviceable Condenser fan motor suitable for 1.5/ 2 Ton capacity split type AC/ window AC and Supply and fixed brand new motor as per existing model/pattern and testing complete all as directed. |
| 11 | S & F in repairs brass service/shut off valve 3/8\\" size suitable for window type AC/Split type ACs of any capacity. |
| 12 | S & F in repairs brass service/hand shut off valve 5/8\\" size suitable for window type AC/Split type ACs of any capacity. |
| 13 | S & F in repairs brass service/shut off valve 1/2\\" size suitable for window type AC/Split type ACs of any capacity. |
| 14 | S & F in repairs brass service/hand shut off valve 1/4\\" size suitable for window type AC/Split type ACs of any capacity. |
| 15 | S & F in repairs Starting relay / single phase contactor suitable for 1.5 / 2 Ton capacity Split type AC unit including dismantling the old one all as directed. |
| 16 | S & F in repairs selector / Rotary switch suitable for 1.5 /2 Ton capacity window type AC unit including dismantling the old one all as directed. |
| 17 | S & F in repairs connector 3 way suitable for 1.5 TR/2 TR Capacity of split AC all as directed. |
| 18 | S & F in repairs air filter suitable for 1.5 / 2.0 Ton capacity window/split type AC unit, including dismantling the old one all as directed. |
| 19 | S & F in repairs over load relay suitable for 1.5/2 Ton capacity window/ Split type AC unit, incl dismantling the old unserviceable one all as directed. |
| 20 | S & F in repairs thermostat suitable for 1.5 / 2 Ton capacity window type AC/Split type AC unit, incl dismantling the old one all as directed. |
| 21 | Supply and fix in repairs Starting capacitor 80 - 100 Mfd, including dismantling the old unserviceable one all as directed. |
| 22 | S & F in repairs starting capacitor 100 - 120 Mfd window type AC / Split AC unit, incl dismantling the old one all as directed. |
| 23 | S & F in repairs running capacitor 45 Mfd 7pin/4pin suitable for 1.5/ 2 Ton Split AC unit/window type AC, including dismantling the old unserviceable one all as directed. |
| 24 | S & F in repairs capacitor 50 Mfd suitable for 1.5/ 2 Ton window / Split AC unit, including dismantling the old one all as directed. |
| 25 | S & F in repairs capacitor 4 / 6 Mfd suitable for 1.5/ 2 Ton window /Split AC unit, including dismantling the old one all as directed. |
| 26 | S & F in repairs capacitor 2.5 Mfd suitable for 1.5/ 2 Ton window / Split AC unit, including dismantling the old one all as directed. |
| 27 | S & F in repairs Air swing motor suitable for Window / Split type AC unit 1.5 / 2 Ton, including dismantling the old one all as directed. |
| 28 | S & F in repairs metal clad plug and socket complete 2 pin top and an earth plug 230 V 20 Amp complete. |
| 29 | S & F in repairs new PCB (Univeral type) unit of 1.5 / 2 TR capacity of Split type AC unit of existing make & model all as directed. |
| 30 | S & F in repairs new PCB (Inverter Type) unit of 1.5 / 2 TR capacity of Split type AC unit of existing make & model all as directed. |
| 31 | M&L for replacement & installation of cordless remote suitable for indoor type 1.5/2 TR capacity split type AC existing make and model complete all as specified and as directed |
| 32 | Supply and fixing mounting bracket made out of MS frame including necessary required PCC and masonary work complete also including reconnecting the copper pipe with new insulation to the indoor and outdoor unit and testing with disconnecting out door/indoor type split type AC unit of cap 1.5TR/2TR and refixing the same with completion as directed. |
| 33 | S & F in repairs Condensing unit suitable for out door unit of 1.5 / 2 TR Split type AC unit, incl dismantling the old one all as directed. |
| 34 | S & F in repairs Condensing unit suitable for out door unit of 8 TR ductable type AC unit, incl dismantling the old one all as directed. |
| 35 | S & F in repairs Compressor unit suitable for out door unit of 8 TR ductable type AC unit, incl dismantling the old one all as directed. |
| 36 | S & F in repairs copper pipe for suction and discharge 5/8'' & 3/8\\" dia incl provn of new insulation over the pipes complete complete for split AC all as directed. |
| 37 | S & F in repairs copper pipe for suction and discharge 1/2'' & 1/4\\" dia incl provn of new insulation over the pipes complete complete for split AC all as directed. |
| 38 | S & F in repairs fan blade for Window/ Split Type ACs AC 1.5/2 TR capacity including taking down the old complete all as directed. |
| 39 | Supply and fixing in repair indoor unit cooling copper coil set complete 1.5 ton capacity suitable for existing Split AC unit all as complete. |
| 40 | Supply and fixing in repair indoor unit canopy plastic body set complete 1.5 ton capacity suitable for existing Split AC unit all as complete. |
| 41 | Supply and fixing in repair split AC outdoor unit cabinet complete as per existing design of unserviceable AC of capacity 1.5 TR complete all as directed by Engr-In-Charge. |
| 42 | Dismantling of existing old UNSV sealed compressor unit of 4 TR capacity for Tower AC unit from the position, supply, install & testing of new compressor unit suitable for 4 TR capacity incl bracing , elctrical connection work complete alll as directed. |
| 43 | M&L for replacement of Blower motor suitable for 4 TR Tower AC , 420 Volt,50 HZ, all as complete. |
| 44 | S & F in repairs micro processor based PCB units for outdoor & indoor unit for 4 TR capacity Tower AC unit by removing old one incl provn necessary copper lugs of 2.5 / 4 Sqmm all as directed. |
| 45 | S & F in repairs Voltage Stablizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 130v to 300 V with output voltage stabilized at 220 V with accuracy of + 5% capacity 4 KVA all as complete. |
| 46 | S & F in repairs Voltage Stablizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 130v to 300 V with output voltage stabilized at 220 V with accuracy of + 5% capacity 5 KVA all as complete. |
| 47 | Replacement of corroded/damaged bottom plate/sheet including welding of legs, denting and removal of existing paint including scraping the old faded paint and applying 2 coats of synthetic enamel paint over a coat of anti corrosion primer using mechanical sprayer, of replaced part of water cooler complete all as directed. |
| 48 | Supply & fix in replacement of three pole contactor of capacity 63 Amps, 230 Volts, 50 Hz for split AC Indoor unit complete all as directed. |
| 49 | Supply & fix in replacement of Nitrail insulation pipe of dia 5/8\\" complete all as directed. |
| 50 | Supply & fix in replacement of Nitrail insulation pipe of dia 1/2\\" complete all as directed. |
| 51 | Supply & fix in replacement of Nitrail insulation pipe of dia 1/4\\" complete all as directed. |
| 52 | Supply & fix in replacement of Nitrail insulation pipe of dia 3/8\\" complete all as directed. |
| 53 | Supply & fix in replacement of rubber foundaiton pad for mounting of split AC outdoor unit |
| 54 | Supply & fix in replacement of temperature sensor of any split AC indoor unit complete all as directed. |
| 55 | S&F of in repair AC outdoor unit suction and discharge valve 1/4 & 1/2 inch type 1 set complete all as directed. |
| 56 | Supply & fix in replacement of display unit as per existing make of any split AC indoor unit complete all as directed. |
| 57 | Supply & fix in repai/replacement of Expansion valve of any split AC indoor unit complete all as directed. |
| 58 | Dismantling and removing defective compressor and replacing the same with new factory sealed compressor of approved make obtained from authroised dealers for 165 / 175 Ltrs capacity refrigerators all as specified and directed. |
| 59 | M&L for evacuation of complete system, charging refrigerant gas F-134 or F -600 for refrigerators 165/175/280/300/310 Ltr capacity incl cutting and brazing of copper tube all as directed. |
| 60 | M&L for replacement of Capillary tube of existing size including necessary brazing suitable for 165/175/280/300/310 Ltr capacity refrigerator, including dismantling the old unserviceable one all as directed. |
| 61 | S & F in repairs over load protector relay for 165/175/280/300/310 Ltr capacity refrigerator, all as directed. |
| 62 | S & F in repairs Thermostat suitable for 165/175/280/300/310 Ltr capacity refrigerator, all as directed. |
| 63 | Supply and fix in repairs strainer drier for 1.5 ton window type AC / split type AC/refrigerator/water cooler complete. |
| 64 | Dismantling and removing defective compressor and replacing the same with new factory sealed compressor of approved make obtained from authroised dealers for water cooler of 40 / 80 Ltrs capacity all as specified and directed. |
| 65 | Dismantling and removing defective compressor and replacing the same with new factory sealed compressor of approved make obtained from authroised dealers for water cooler of 120 / 150 Ltrs capacity all as specified and directed. |
| 66 | M&L for water servicing of water cooler of capacity 40/80 to 75/150 Ltr including cleaning of water cooler tank after disconnecting the incoming water supply connection and re fix the same on its original position after cleaning all as specified and as directed by Engineer in Charge |
| 67 | M&L for evacuation of complete system, charging refrigerant gas F-134 or F -22 for water coolers 40/80 Ltr capacity including cutting and brazing of copper tube complete all as directed. |
| 68 | S & F in repairs Over load protector relay suitable for 40/80/120/150Ltr capacity water cooler,all as directed. |
| 69 | S & F in repairs Thermostat suitable for 40/80/120/150Ltr capacity water cooler,all as directed. |
| 70 | S & F in repairs Condenser motor incl fan blade suitable for 40 / 80 Ltr capacity water cooler, incl dismantling the old one all as directed. |
| 71 | S & F in repairs Condenser motor incl fan blade suitable for 120 / 150Ltr capacity water cooler, incl dismantling the old one all as directed. |
| 72 | S & F in repairs PVC drain pipe 25 mm dia with suitable standard clip complete fix to water cooler of any capacity incl dismantling the old one all as directed.. |
| 73 | S & F in repairs Drain water tray complete suitable for 40/80/120/150Ltr capacity water cooler as per existing size or shape, incl dismantling the old one all as directed. |
| 74 | S & F in repairs CP brass push cock for any capacity of water cooler all as direcetd. |
| 75 | S & F in repairs overload protector for water cooler 40/80/120 ltr capacity incl dismantling the old damaged overload protector complete. |
| 76 | S & F in repairs PVC Float valve of size 15 mm dia complete suitable for 40/80/120/150Ltr capacity water cooler including required GI socket of same size, including dismantling the old unserviceable one all as directed. |
| 77 | Charges for atteneding the emergent complaint for cooling applainces such as Split/window/tower ACs, Refrigerator, and Water cooler of any capacity/size/make installed at INS hansa, by providing one AC mechanic and one helper alongwith required tools. The contractor shall maintain the service slip/job card and submitted the same duly signed by concerned executives and user to the department on post attended complete all as directed by engineer-in-charge. |
| 78 | M/L for taking down and shifting of ACs to new location including core cutting of wall and putty work for drain hole filling all as directed by Eng-in-charge.Note:- Copper pipe, gas filling, outdoor ms frame and electric/electronic items found defective during shifting will be executed, measured and paid separately under relevant item of this schedule . |
| 79 | M/L for PCC and masonary work complete also including reconnecting the copper pipe with new insulation to the indoor and outdoor unit and testing with disconnecting out door/indoor type tower AC of Capacity 4 TR or Water cooler and refixing the same complete all as directed by Eng-In-Charge. |
| 80 | Supply and fix MCB DB, Triple pole and neutral with suitable rated busbar double door, 4 way 415 volt 50 HZ AC Supply complete all as specified and directed. |
| 81 | Supply and fix MCB DB, Single pole and neutral with suitable rated busbar double door, 8 way 240 volt 50 HZ AC Supply complete all as specified and directed. |
| 82 | Supply and fix MCB SPN DB single door with suitable rated busbar double door, 4 way 240 volt 50 HZ AC Supply complete all as specified and directed. |
| 83 | S&F MCB TPN 40 to 100 Amp 415 volts,50Hz,Breaking Capacity 10 KA in existing DBs complete all as specified and directed |
| 84 | M & L for repairing of earthing complete with Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earth lead shall be provided with GI pipe light grade 20 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and directed by Engr-in-charge. |
| 85 | S&F MCB SP 06 to 32 Amp 230 volts,50Hz,Breaking Capacity 10 KA in existing DBs complete all as specified and directed |
| 86 | M/L for new sub main wiring with 2 run single core 4.0 sq mm PVC unsheathed copper multistranded, FRLS conductor drawing into and including PVC conduit medium grade of size not less than 20 mm dia with all fittings and fixtures like L- bow,saddles etc of white/lvory colour PVC conduit including multi stranded copper earth conductor 4.0 sq mm two run as earth continuty conductor including taking down the old sub main wiring and all as directed by Engineer in Charge. |
| 87 | Taking down the old sub main wiring and M/L for new sub main wiring with 4 run single core 10.0 sq mm PVC unsheathed copper multistranded, FRLS conductor drawing into and including PVC conduit medium grade of size not less than 25 mm dia with all fittings and fixtures like L- bow,saddles etc of white/lvory colour PVC conduit includinh multi stranded copper earth conductor 10.0 sq mm two run as earth continuty conductor all as directed by Engineer in Charge. |
| 88 | S&F MCB SP SPN 40 to 63 AMP 230 volts,50Hz,Breaking Capacity 10 KA in existing DBs complete all as specified and directed Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 26 daysAug 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 29 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender