Defence Statutory Bodies & Commissions/Committees Closing in 8 days TDR #56531648

Tender For Repair/ Maintenance To Sewage Line, Manhole, Soakage Pit, Septic Tank, Hard Standing / Platform, Plinth Protection, Apron, Rain Water Pipe, Sun Shades, Chajjs And Other Structural Elements In Residential And Tech Area At R&De(E) Dighi Pune

Issued by Statutory Bodies & Commissions/Committees · Pune, Maharashtra
Tender Value
30 Lakhs
Estimated cost
Bid Submission
07 Aug 2026
8 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair/ Maintenance To Sewage Line, Manhole, Soakage Pit, Septic Tank, Hard Standing / Platform, Plinth Protection, Apron, Rain Water Pipe, Sun Shades, Chajjs And Other Structural Elements In Residential And Tech Area At R&De(E) Dighi Pune-15

BOQ

Name of Work:- REPAIR/ MAINT TO SEWAGE LINE, MANHOLE, SOAKAGE PIT, SEPTIC TANK, HARD STANDING / PLATFORM, PLINTH PROTECTION, APRON, RAIN WATER PIPE, SUN SHADES, CHAJJS AND OTHER STRUCTURAL ELEMENTS IN RESIDENTIAL AND TECH AREA AT R&DE(E) DIGHI PUNE-15
Sl. No. Item Description
1M & L for Removal of Trees/Plants complete incl roots any dia, any masonary at any hight. including applying root killer chemical as per manufacturer’s instructions and making good disturbed portion with PCC 1:2:4 Type B0 (using 12.5 mm graded stone aggregate)in cm 1:3 and finishing the surface to match with existing surface and removing of rubbish out side MoD land/area complete all as specified and directed.
2Grass cutting/cleaning away grass vegetation sampling shurbs brushwood etc near sewage line by manually/ mechanically brooming the entire grass/ vegeted cutted area and make neat and clean. Removing the cutted grass/ vegetation to a distance not less than 50 mtr or as directed by EIC.
3Cleaning of Sewage line of dia 150 mm bore pipe lines of any description in between two consecutive manholes to the entire satisfaction of Engineer-in-Charge and testing by pouring water from manhole to manhole complete all as specified and directed.
4All as per Srl item No 03 above but 200 mm bore pipe complete all as specified and directed.
5All as per Srl item No 03 above but 300 mm bore pipe complete all as specified and directed.
6Pumping out Sewage water from the blocked sewage line of or overflow manholes of any description and depth in between two consecutive manholes by sewage suction /Jetting machine (with high pressure water supply mounted) / vacuum operated suction machine or sewer Jetting Machiche and is effective in collecting sludge and sewer from the cesspit or Jetting the Water Through high Pressure for opening the sewer Line. for removing any type of blockage (Cost of No labour deemed to be included in rates coated by Contractor) . complete all as specified and directed by Engineer-in-Charge and testing by pouring water from manhole to manhole. and remove sluge from outside Mod land.
7Cleaning of septic tanks of the following capacity by dewatering all the water, taking out the sludge/ night soil. Flushing the septic tank with clean water in order to remove all stacked mud/sludge etc cleaning the choked inlets. Outlets of septic tank removing all the sludge to outside MD land including surface dressing of the septic tank around the distance not less than 3 mtr all specified and directed. Septic tank capacity upto 600 users.Note:- The night soil / sludge including water obtained by cleaning of the septic tank shall be taken out in closed container and disposed off outside MD land by excavating a pit of adequate size and depth not exc.1.5m
8Cleaning of manhole of any description, any size and any depth including removing sludge and deposited outside MD land etc complete all as directed by Engineer-in- Charge.
9Cleaning of Gully Traps of any description, any size and depth including removing sludge and deposited outside MD land etc complete all as directed by Engineer-in- Charge.
10Removing of blockage from 'S' trap/'P' trap/ Nahani trap/floor trap by flushing or by sucking by suction pumps at GF/ Ist/ IInd/ IIIrd floor or any floor including cleaning the line upto 1st manhole complete all as specified and directed.Note: (i) The unit rate quoted shall be demed to be included the elements of labour only for rectifying and making the fittings and fixture functional. If replacment of part/items is required to make the fitting functional,the cost for labour and material for the same will be easured and paid for as S&F in repairs under relevent items of this schedule here in after and in such cases this item will not be measured and paid for (ii) The unit rate quoted by the contractor shall be inclusive of working & attending the complaints as diected by JE(civil) or Engr in Charge. (iii) The Safhaiwala who is on duty must be provided with common mobile cell to faciliate and render good services to the users. (iv) Complaints slip to be collected daily from complaints cell/AGE B/R Dighi. (v) Contractor shall provided all the necessary tools/Ladder and make necessary transportion arrangements etc required for attending complaints with proper tool bag complete all as specified and directed.
11Demolition of precast concrete block/brick masonry or stone masonary built in cement mortar complete all as specified and directed.
12M&L for PCC block masonry with soild blocks Type C1 1 :3:6 (20mm grade agg) exc 10 cm in width and setting in CM 1 :6 complete all as specified and directed.
13Excavation in trenches n.exc 1.5m deep and n.exc 1.5m wide in manholes,Drains & Post hole etc. getting out in soft soil complete all as specified and directed.
14Demolition of cement concrete bed in haunching and breaking up RCC drain pipe 150 mm dia set in cement mortar of the following dia complete all as specified and directed.
15Demolition of cement concrete bed in haunching and breaking up RCC drain pipe exc 150mm n exc 300 mm dia set in cement mortar of the following dia complete all as specified and directed.
16M&L for concrete bed in P.C.C. 1:4:8 type D2 (using 40mm graded aggregated) to 150 mm dia drain pipes including packing under and haunching against the sides of the pipes after laying & testing complete all as specified and directed.
17M&L for concrete bed in P.C.C. 1:4:8 type D2 (using 40mm graded aggregated) to exc 150mm n exc 300 mm dia drain pipes including packing under and haunching against the sides of the pipes after laying & testing complete all as specified and directed.
18M&L for reinforced concrete NP2 drain pipes 150 mm dia confirming to IS laid in trenches and jointed in CM 1:2 complete all as specified and directed.
19M&L for reinforced concrete NP2 drain pipes exc 150 mm n exc 300 dia confirming to IS laid in trenches and jointed in CM 1:2 complete all as specified and directed.
20Returning filling in soft/loose soil including spreading, levelling and well ramming in layers n.exc 25cm thick in layer etc complete all as specified and directed.
21Removing excavated material (soil) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
22M & L for cutting in to existing manhole for connectiing new drain 150 mm bore , making good to pipe & renderring cutting out existing benching for & forming branch channel in cement concrete ( 1:2:4) type B1 smooth finished & reforming benching as requierd complete all as specified and directed.
23M&L for PCC (1:2:4) type B1 (using 20mm graded stone aggregate) including necessary form work as in flooring , Hardstanding , roof kerbs or mud stops, surface channels, manholes etc and finishing the surface even and fair without using extra cement complete all as specified and directed.
24Taking down cement plaster on brick or stone wall etc incl racking out joints hacking for key & scrubbing down with water etc.complete all as specified and directed.
25M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete sufaces including finished even and smooth using extra cement complete all as specified and directed.
26Supply & laying integral water proofing compound complete all as specified and directed.
27M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement incl, forms mould, mi-tred/stopped ends etc complete all as specified and directed.
28S&F in repairs 50mm thick precast reinforced (steel fibres) cement concrete drain cover slabs square or rectangular in size supprted on walls complete all as specified and directed Note: Rate shell deemed to be including Reinforcement (Steel fibres) used in the drain covers complete all as specified and directed.
29M & L for forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade A complete all as specified and directed.
30Taking down for repairing and refixing in new or same position of chainlink fencing of any shape and size including fencing posts and horizontal supporting bars, fillets, bolt and nuts etc complete all as specified and directed.Note: replacement of any old materials by new one will be measured and paid in relevant items of this schedule.
31Removing old concrete debries, UNSV chequered tiles/ interlocking tiles etc outside the MD land complete all as specified and directed.
32Demolition of plain cement concrete (Un reinforced) in benching and surface channels, drains,coping, Plinth protection and Manholes above ground level complete all as specified and directed.
33M&L for 75mm thick cement concrete type C2 1:3:6 using 40mm graded aggregate as in flooring/ plinth protection and finished concrete surfaces even & smooth without using extra cement complete all as specified and directed.
34M&L PCC (1:4:8) type D-2using 40 mm graded stone aggregate 75mm thick as in sub bases, finished even & rough to receive finishing layer, etc complete all as specified and directed.
35M&L for 50mm thick sand cusion under layer of floor complete all as specified and directed.
36S&F in repairs for machine pressed, rubber moulded, precast concrete interlocking paver block any shape, colour , size and pattern as approved by GE conforming to IS 15658-2006 of 60 mm thick, M-35 Grade & glossy finish with white or coloured cement and pigment all in specified and directed.
37M&L for Cement concrete tile glossy finish 25 cm x 25 cm x 22mm thick machine pressed set and including 15mm thick screed bed CM(1:6), jointed and pointed in neat cement slurry in floor with white cement & pigments and cut and polished complete all as specified and directed.
38Demolition and breaking up drain pipes (PVC / SGW / AC or CI Pipes) set in any cement mortar of (75mm / 110mm / 100mm / 150mm / 200mm / 250mm) dia of pipe complete all as specified and directed.
39S&F in repairs 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
40S&F in repairs 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
41Dismantling of floors health or walls tiling and Stone floor including cement mortar bedded & removing serviceable tiles to store and rubbies of the premises complete all as specified and directed.
42Demolition of cement concrete in ground floors and pavings n exc 15 cm (below or above ground level) complete all as specified and directed.
43M&L in repair of 25mm thick PCC 1:2:4 type B-0( 12.5 mm graded stone aggre) as in sub base of floor etc complete all as specified and directed.
44M&L for 15mm thick Screed bed or bedding layer of mortar in CM 1:4 for laying floor finishes all as specified & directed.
45M&L for Rendering 10mm thick (as backing coat) on fair faces of brick work or concrete sufaces in CM 1:3 complete all as specified and directed.
46M&L for Coloured Non Skid ceramic tiles 8 to 9 mm thick (square/ rectangular) area of each tile exceeding 0.09 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
47M&L for coloured Glazed ceramic tiles in vertical surfaces 450/ 600x300 mm thickness as per manufacture ( With two borders and mothiff pattern ) / High lighter tiles on vertical surfaces such as skirting, dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to matchover a backing coat of 10 mm thick plaster in CM 1:4 including dubbing out coat to an average thickness of 10 mm thick in CM (1:6) , complete all as specified and directed.
48S&F in repairs vitreous china squatting pan , ‘Orissa’ pattern, size 580 mm x 440 mm, white with integral foot rests, embedded and set in PCC 1:5:10 type E-2 and making good to floor including removing rubbish complete all as specified and directed.
49S&F in repairs, vitreous China wash down water closet pan, (pedestal pattern), white, with and including plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, flush pipe for joining etc complete all as specified and directed.
50S&F in repairs 100mm dia CP grating for nahani traps with or without hole for waste pipe complete all as specified and directed.
51S&F PVC (SWR) bends any radius (bore 110mm) complete all as specified and directed.
52S&F PVC (SWR) bends any radius (bore 75mm) complete all as specified and directed.
53S&F PVC (SWR) junction (single/double T) equal or unequal any radius (bore 110mm) complete all as specified and directed.
54S&F PVC (SWR) junction (single/double T) equal or unequal any radius (bore 75mm) complete all as specified and directed.
55Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
56M&L precast RCC 1:2:4 type B1 ( using 20 mm graded stone aggregate) as in cover slab set in CM 1:4 incl necessary form work complete all as specified and directed.
57M&L 6mm to 8mm dia mild steel TMT bars , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
58S&F in repair PVC floor trap/nahani trap incl stainless steel gratings, 75/100 mm dia of outlet, including jointing to waste pipe fixed in cement concrete type B1(1:2:4) complete all as specified and directed.
59M&L for precast RCC septic tank in repair for unservicable/abandoned septic tank made of Reinforced cement concrete 100% leak proof Eco - Friendly Most ideal for marshy lands compatible size & shape Economical & long lasting Cylindrical in shape of size length 2.4m x 750mm to 900mm used for 20 to 30 user. Note : Rates including excavation of any type of soil , backfilling and make good the surface and connection to sewage line complete all as specified and directed.
60M&L for non structural steel framed work as in doors or gates of angle and truss or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to beprepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
61Supply and fix in repairs Vitreous China bowl urinal bowl type, with discharge pipe (including Angle cock ,urinal spreader ,PVC Connection and and waste pipe) (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; with brackets, flush pipe, and Union for discharge pipe complete all as specified and directed.
62Supply and fix in repairs Vitreous China bowl urinal full stall type, with discharge pipe (including Angle cock ,urinal spreader ,PVC Connection and and waste pipe) (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; with brackets, flush pipe, and Union for discharge pipe complete all as specified and directed.Note: (i) All necessary precautions and all safety measures per Municipiality rules/relevant regulatory guidelines shll be taken by the contractor in employing his mechanical means and workmen. No person shall be employed in direct contact working in septic tanks,manholes in foel conditions to prevent any helath hazards.(ii) The contractor shall be solely resposnible for any mishap to any of labour deployed and to equipment /machinery /plants/ materials etc brought at site for work any lapses whatsover during the execution. (iii) Drawn sluge, waste material ,scum , spoil water etc shall be removed from Mod land through sludge carrier. The rates quoted shell be deemed to be inclusive of above all aspect and no claim whatever shall be entertainable at later stages.
63Dismantling of plain or corrugated steel sheeting any gauge,thickness,including Nainital or similar pattern roof covering complete all as specified and directed.
64Supply and Fixing Pre - painted galvatume aluminium zine coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56531648
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 30 Lakhs
LAST DATE 07-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Maintenance To Sewage Line, Manhole, Soakage Pit, Septic Tank, Hard Standing / Platform, Plinth Protection, Apron, Rain Water Pipe, Sun Shades, Chajjs And Other Structural Elements In Residential And Tech Area At R&De(E) Dighi Pune-15
Basic Detail
Tender No GE I R AND D GNR TOKEN 30 OF 2026-27(8018)
Bidding Type Tender
Location
City Pune
State Maharashtra
Key Dates
Publish Date 17 Jul 2026
Submission Date 07 Aug 2026
Open Date 10 Aug 2026
Finance
Tender Value 30 Lakhs
Tender Fee 500
EMD 60000
Exemption Not Available
Document List
1c82b838-e7aa-40e2-a138-26df51865f19.html
BOQ_872715.xls
TENDERDOCUMENT.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Aug 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

1c82b838-e7aa-40e2-a138-26df51865f19.html

xls

BOQ_872715.xls

pdf

TENDERDOCUMENT.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail