Housing Urban and Rular Development Government Departments Closing in 0 days TDR #56529422

Tender For B.O.Q For Revival, Restoration, Preservation And Maintenance Of Astan Alya Syed Hussain Qumi (Ra) {Architecture & Heritage) At Saidpora Zaingeer Baramulla B.W.O Electric Work

Issued by Government Departments · Baramulla, Jammu and Kashmir
Tender Value
5 Lakhs
Estimated cost
Bid Submission
24 Jul 2026
0 days left
EMD
10000
Bank guarantee accepted
Document Fee
200
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Baramulla → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for B.O.Q For Revival, Restoration, Preservation And Maintenance Of Astan Alya Syed Hussain Qumi (Ra) {Architecture & Heritage) At Saidpora Zaingeer Baramulla B.W.O Electric Work

BOQ

Name of Work:- B.O.Q for Revival, Restoration, Preservation and Maintenance of Astan Alya Syed Hussain Qumi (RA) {Architecture & Heritage) at Saidpora Zaingeer Baramulla B.W.O Electric work
Sl. No. Item Description
1Wiring for Light point/Fan point/Exhaust fan/Bell point with (P+N+E) 3x1.5 sq.mm FRLS-H PVC insulated Multi strand Copper conductor single core cable, (Havells Lifeguard/Polycab Green/Anchor Fireguard/ Apar/ Eq Make) in surface/recessed Conduits laid in slabs (Including Cost of Conduit 25mm) with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified/Schneider Zencelo/ Havells Crabtree/ Legrand Arteor/Anchor roma plus/ABB Tvisha (anti bacterial)/Eq.Make & & items shall be approved before execution of work by SDO.
2Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required,ISO/IEC Certified of Schneider Zencelo/ Havells Crabtree/ Legrand Arteor/Anchor roma plus/ABB Tvisha (anti bacterial)/Eq.Make & shall be approved before execution of work by SDO.
3Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells Lifeguard/Polycab Green/Anchor Fireguard/Apar/ Eq Make) including Copper thimbles for terminating/originating
4Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified /Schneider Zencelo/ Havells Crabtree/ Legrand Arteor/Anchor roma plus/ABB Tvisha (anti bacterial)/Eq.Make& shall be approved before execution of work by SDO.
5Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells Lifeguard/ Polycab Green/Anchor Fireguard/Apar/ Eq. Make)
6Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Schneider Zencelo/ Havells Crabtree/ Legrand Arteor/Anchor roma plus/ABB Tvisha (anti bacterial)/Eq.Make & shall be approved before execution of work.
7Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor (Havell Lifeguard/Polycab Green/Anchor Fireguard/Apar/ Eq. make.), single core cable in surface/ recessed medium class PVC conduit as required.
82 X 1.5 sq. mm +1 X1.5 sq. mm earth wire for replacement of old damaged wire
92 X 2.5 sq. mm +1 X 2.5 sq. mm earth wire replacement of old damaged wire
10Supply/Installation/Testing and Commissioning of 18W + LED recess light (Commerical Type) light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Philips/Havell's/Wipro/Halonix Make.
11Supply, Installation, Testing & Commissioning (SITC) of 30 W rechargeable LED emergency lamp, complete with high-efficiency LED module, inbuilt rechargeable lithium-ion battery, automatic charging and emergency changeover, minimum 3–6 hours battery backup, cool white (6500 K), minimum 2400–3000 lumens, ABS/polycarbonate housing, suitable for wall mounting or portable use, operating on 230 V AC, 50 Hz, complete with charger, mounting accessories and all necessary hardware, conforming to relevant IS/IEC standards of Philips/Havells/Wipro/Halonix/Eq.make as directed by SDO
12Supply, Installation, Testing and Commissioning of 4/6-way decorative chandelier (Jhumar) suitable for prayer hall, fabricated from premium quality crystal/K9 crystal with MS/SS frame having antique brass, gold or chrome finish, complete with 10 Nos. LED lamps of 9 W each (warm white 3000 K), ceiling suspension arrangement, canopy, internal wiring with FRLS copper conductors, fixing accessories and all necessary hardware, complete as required at site. Havells Decorative/Jaquar Decorative/Philips Deorative
13Supply installation testing and commissioning of Flexible waterproofwith IP68 rating, Siliconmade, LEDRope light 6 watt permeter,400 lm/Mt,72 LEDsperMtr, (Color :Warm White/Yellow/Green/Blue as desired by SDO),completewith connectors, end caps, suspension kits, and all necessary accessories forproper installationandoperation. ,usinghigh brightnessSMDLEDasthelightsourcesuitablefordecorative lighting alongwith suitable LEDdriver for providing power supply to the LED strip. Prefered make : Philips/Havell/Crompton/ Equivalent standard mak
14Providing & Fixing of IK08 IP-66 protected high power LED 50 Watt flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 Im/wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR:-High Power LED Flood Light Minimum lumen output 6200 Im of Havells/Halonix/Philips /Eq.make Make as approved and to be installed on outside block including S/F of suitable size of Gyser bolt.The job further includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department.
15Supply, Installation, Testing and Commissioning of decorative 1200 mm sweep, ceiling fan with 3 No. Aluminium blades, 30 cm long down rod, 2nos. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, and including iron hook complete . USHA Striker/Havells Oyster matalic/CromptonAura/equivalent make as directed by engineer incharge.
16Providing, fixing, testing and commissioning of wall-mounted oscillating fan, sweep size 450 mm (18 inch), operating on 230 V ±10%, 50 Hz AC supply, complete with heavy-duty motor, aluminium blades, protective guard, and on/off speed control. The fan shall be suitable for continuous operation, noiseless performance, and high air delivery.The item includes wall bracket, clamps, nuts, bolts, necessary wiring connections up to ceiling rose/switch, and all accessories required for proper installation, as approved by the Engineer-in-Charge.Make: Havells / Crompton / Usha / Orient or equivalent approved make.
17Supply and fixing of wooden channel/ casing made from Kashmiri budloowood having 2.6\\"-3\\" width suitable for carrying out wiring for different circuits.
18Supply/Fixing/Testing and Commissioning of following rating, Double pole, (P+N) 240 V, C* Curve 10K,Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections. (L&T/Siemens /Legrand/ABB/Schneider Make)
1940Amp.
2063Amp.
2132 Amp
22100 Amp For Main Supply with Metal Enclosure Box
23Supply/Fixing/Testing and Commissioning of 6Amp to 16Amp Rating SP,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB . DB Complete with connections.(L&T/Siemens/Legrand/ABB /Schneider Make)
24Supplying and Fixing of MCB 6-Way (4+18) horizontal typed , sheet steel, Double Door Distribution Board, TPN 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ Schneider Make)
25Supply/Installation/Testing/Commissioning of Inverter 1100VA/12 V Pure Sinewave Inverter With ISOT Technology, Intelligent Load Sharing & BIS Certified (with 2-Year Warranty), 01 No. of 180Ah,12V Tubular battery (with 60 Months Warranty) & Suitable Trolley Support for Inverter resting & resting of Tubular Battery etc /Luminious/EXIDE /AMRON/Eq. Make Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56529422
AUTHORITY Government Departments
TENDER VALUE 5 Lakhs
LAST DATE 24-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for B.O.Q For Revival, Restoration, Preservation And Maintenance Of Astan Alya Syed Hussain Qumi (Ra) {Architecture & Heritage) At Saidpora Zaingeer Baramulla B.W.O Electric Work
Basic Detail
Tender No NIT No.82//2026-27 Dt/17/07/2026
Bidding Type Tender
Location
City Baramulla
State Jammu and Kashmir
Key Dates
Publish Date 17 Jul 2026
Submission Date 24 Jul 2026
Open Date 25 Jul 2026
Finance
Tender Value 5 Lakhs
Tender Fee 200
EMD 10000
Exemption Not Available
Document List
BOQ_1032531.xls
d79fee0f-37f5-42ef-8863-d9ddc26a62ae.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Jul 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1032531.xls

html

d79fee0f-37f5-42ef-8863-d9ddc26a62ae.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders