Bids Are invited for Design Supply Installation Testing And Commissioning Roof Top Type Solar Power Plant
Tender Overview
Project Description
Bids Are invited for Design Supply Installation Testing And Commissioning Roof Top Type Solar Power Plant Provision Of Solar Pv Modules For Roof Top Type Solar Power Plant Of Capacity 50 Kwp - Design Supply Installation Testing And Commissioning Of Grid Connected On Grid Roof Top Type Solar Power Plant Of Capacity 50 Kwp Solar Photovoltaic Power Plant Using String Inverter With Optimizers Having Bis And Cloud Or Cyber Security Certifications Complete With All Accessories Having Minimum 5 Years System Warranty And Inverter Warranty 12 Years And Product Warranty For Pv Module 12 Years And Product Linear Warranty 30 Years Inclusive Of Miscellaneous Charges Such As Loading Unloading Site Clearance If Any Transportation All Taxes And Duties Etc. The Roof Top Type Solar Power Plant Shall Comprising As Per Scope Of Work All As Per Oem Design And Drawings As Approved By The Engr In Charge. Qty 70 Nos Solar Pv Modules , Provision Of Solar Grid Tie String Inverter 50 Kw 3 Pha For Solar Power Plant - Design Supply Installation Testing And Commissioning Of Solar Grid Tie String Inverter As Per Scope Of Work All As Per Oem Design And Drawings As Approved By The Engr In Charge. Qty 01 Nos , Provision Of Super Structure For Module Mounting For Solar Power Plant - Design Supply Installation Testing And Commissioning Of Super Structure For Module Mounting As Per Scope Of Work All As Per Oem Design And Drawings As Approved By The Engr In Charge. Qty 01 Set As Per Site Requirement , Provision Of Ac And Dc Distribution Boards For Solar Power Plant - Design Supply Installation Testing And Commissioning Of Ac Distribution Board And Dc Distribution Board As Per Scope Of Work All As Per Oem Design And Drawings As Approved By The Engr In Charge. Qty 01 Nos For Ac Distribution Board And Qty 01 Nos For Dc Distribution Board. , Provision Of Remote Monitoring For Solar Power Plant - Design Supply Installation Testing And Commissioning Of Remote Monitoring As Per Scope Of Work All As Per Oem Design And Drawings As Approved By The Engr In Charge. Qty As Per Site Requirement , Provision Of Bi And Uni Directional Net Meter Low Tension Tod Meter For Solar Power Plant - Design Supply Installation Testing And Commissioning Of Bi Directional Net Meter Low Tension Time Of Day Meter And Uni Directional Net Meter Low Tension Time Of Day Meter As Per Scope Of Work All As Per Oem Design And Drawings As Approved By The Engr In Charge. Qty 01 Nos Set Of 04 For Bi Directional Net Meter Low Tension Tod Meter And Qty 01Nos Set Of 04 For Uni Directional Net Meter Low Tension Tod Meter , Provision Of Load Sharing Outdoor Lt Panel For Solar Power Plant - Design Supply Installation Testing And Commissioning Of Load Sharing Outdoor Lt Panel As Per Scope Of Work All As Per Oem Design And Drawings As Approved By The Engr In Charge. Qty 01 Nos For Load Sharing Outdoor Lt Panel With Accessories As Per Scope Of Work , Provision Of Cabling Lightning Arrester And Earthing For Solar Power Plant - Design Supply Installation Testing And Commissioning Of Armoured Aluminium Conductor Power Cable Of Size 50 Sqmm 3.5 Core And Earthing And Lightning Arrester As Per Scope Of Work All As Per Oem Design And Drawings As Approved By The Engr In Charge. Qty 20 Mtr For Cabling And Qty 02 Set For Lightning Arrester And Qty 06 Set For Earthing And Qty 20 Mtr For 10 Swg Copper Conductor With Accessories As Per Scope Of Work , Cleaning System For Solar Pv Module For Solar Power Plant - Design Supply Installation Testing And Commissioning Of Cleaning System For Solar Pv Modules Shall Be Provided With Pvc Water Tank Of Capacity Not Less Than 500 Ltrs Isi Marked With Suitable Size Or Rated Pump Not Less Than 0.5 Hp Duly Connected For Water Inlet And Pump Outlet Pressure Pipe Connection With Upvc Pipe Water Pipe Of Suitable Size And Length Including Necessary Hose Pipe With Control Stop Valve Necessary Ladder With Walk Ways Or Platform Fabricated From Structural Steel Section Adequate Size With Hand Railing Support System With Gi Pipe Medium Of Suitable Size Duly Grouted Or Fixed To Wall Or Rcc Or Tiled Roof Slab Etc For Safe Access And Safe Movement Of Men For Cleaning Duty At Roof All As Per Site Requirements Per Scope Of Work All As Per Oem Design And Drawings As Approved By The Engr In Charge. Total Quantity : 9
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Provision of Solar PV Modules for Roof top type Solar Power Plant of capacity 50 KWP | Design Supply Installation Testing and Commissioning of Grid Connected on grid Roof Top type solar power plant of capacity 50 Kwp Solar Photovoltaic power plant using string inverter with optimizers having BIS and cloud or cyber security certifications complete with all accessories having minimum 5 years system warranty and inverter warranty 12 years and product warranty for PV module 12 years and product linear warranty 30 years inclusive of miscellaneous charges such as loading unloading site clearance if any transportation all taxes and duties etc. The Roof top type solar power plant shall comprising as per Scope of Work all as per OEM design and drawings as approved by the Engr in Charge. Qty 70 Nos Solar PV Modules |
| 2 | Provision of Solar Grid Tie String Inverter 50 KW 3 PHA for Solar power Plant | Design Supply Installation Testing and Commissioning of Solar Grid Tie String inverter as per Scope of Work all as per OEM design and drawings as approved by the Engr in Charge. Qty 01 Nos |
| 3 | Provision of super structure for module mounting for Solar power Plant | Design Supply Installation Testing and Commissioning of Super structure for Module mounting as per Scope of Work all as per OEM design and drawings as approved by the Engr in Charge. Qty 01 Set as per site requirement |
| 4 | Provision of AC and DC Distribution Boards for Solar power Plant | Design Supply Installation Testing and Commissioning of AC Distribution board and DC Distribution board as per Scope of Work all as per OEM design and drawings as approved by the Engr in Charge. Qty 01 Nos for AC distribution board and qty 01 Nos for DC distribution board. |
| 5 | Provision of Remote Monitoring for Solar power Plant | Design Supply Installation Testing and Commissioning of Remote Monitoring as per Scope of Work all as per OEM design and drawings as approved by the Engr in Charge. Qty as per site requirement |
| 6 | Provision of Bi and Uni directional net meter Low Tension TOD Meter for Solar power Plant | Design Supply Installation Testing and Commissioning of Bi directional Net meter Low Tension Time of day Meter and Uni directional Net meter Low Tension Time of day Meter as per Scope of Work all as per OEM design and drawings as approved by the Engr in Charge. Qty 01 Nos set of 04 for Bi directional net meter Low Tension TOD Meter and qty 01Nos set of 04 for Uni directional net meter Low Tension TOD Meter |
| 7 | Provision of load sharing outdoor LT Panel for Solar power Plant | Design Supply Installation Testing and Commissioning of load sharing outdoor LT Panel as per Scope of Work all as per OEM design and drawings as approved by the Engr in Charge. Qty 01 Nos for load sharing outdoor LT Panel with accessories as per scope of work |
| 8 | Provision of cabling lightning arrester and earthing for Solar power Plant | Design Supply Installation Testing and Commissioning of armoured aluminium conductor power cable of size 50 Sqmm 3.5 Core and earthing and lightning arrester as per Scope of Work all as per OEM design and drawings as approved by the Engr in Charge. Qty 20 Mtr for cabling and Qty 02 set for lightning arrester and Qty 06 set for earthing and Qty 20 Mtr for 10 SWG copper conductor with accessories as per scope of work |
| 9 | Cleaning system for solar PV Module for Solar power plant | Design Supply Installation Testing and Commissioning of Cleaning system for Solar PV modules shall be provided with PVC water tank of capacity not less than 500 Ltrs ISI marked with suitable size or rated pump not less than 0.5 HP duly connected for water inlet and pump outlet pressure pipe connection with UPVC pipe water pipe of suitable size and length including necessary hose pipe with control stop valve necessary ladder with walk ways or platform fabricated from structural steel section adequate size with hand railing support system with GI pipe medium of suitable size duly grouted or fixed to wall or RCC or tiled roof slab etc for safe access and safe movement of men for cleaning duty at roof all as per site requirements per Scope of Work all as per OEM design and drawings as approved by the Engr in Charge. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents