Defence Statutory Bodies & Commissions/Committees Closing in 13 days TDR #56523284

Tender For Miscellaneous Repair To Electric Substation With Replacement Of Electric Flow Chart Diagrams, Distribution Networks , Replacement Of Insulation Matting, Renewal Of Earthings Of Switch Gears At Ayodhya Cantt Under Age(I) Ayodhya.

Issued by Statutory Bodies & Commissions/Committees · Ayodhya, Uttar Pradesh
Tender Value
10 Lakhs
Estimated cost
Bid Submission
07 Aug 2026
13 days left
EMD
20000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ayodhya → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Miscellaneous Repair To Electric Substation With Replacement Of Electric Flow Chart Diagrams, Distribution Networks , Replacement Of Insulation Matting, Renewal Of Earthings Of Switch Gears At Ayodhya Cantt Under Age(I) Ayodhya.

BOQ

Name of Work:- MISCELLANEOUS REPAIR TO ELECTRIC SUBSTATION WITH REPLACEMENT OF ELECTRIC FLOW CHART DIAGRAMS, DISTRIBUTION NETWORKS , REPLACEMENT OF INSULATION MATTING, RENEWAL OF EARTHINGS OF SWITCH GEARS AT AYODHYA CANTT UNDER AGE(I) AYODHYA.
Sl. No. Item Description
1M&L in repair/replacement for earthing complete with using galvanized steel earth plate (electrode) 600 mmX 600 mmX 6.0 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plate using 32X6 mm GI earth strip as earth lead moulded and riveted to earth plate at one end and connected to main equipment at switch/control board at another end, GI earth lead incased in and including 50 mm dia GI ‘light grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘light grade’ as water pipe from earth chamber to upper edge of the earth plate, GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mm thick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone agg) including necessary excavation and earth work in soft/loose soil all as shown in Electric plate No 3 of SSR Part-I and testing on completion complete all as specified and directed by Engr-in-Charge.
2M&L in repair/replacement for earthing complete with using copper earth plate (electrode) 600 mmX 600 mmX3.15 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plate using 20X3mm copper earth strip as earth lead moulded and riveted to earth plate at one end and connected to main equipment at switch/control board at another end, GI earth lead incased in and including 50 mm dia GI ‘light grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘light grade’ as water pipe from earth chamber to upper edge of the earth plate, GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mm thick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone agg) including necessary excavation and earth work in soft/loose soil all as shown in Electric plate No 3 of SSR Part-I and testing on completion complete all as specified and directed by Engr-in-Charge.
3S&F in repair/replacement of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required by galvanized iron strip 32x6mm all as specified and as directed
4S&F in repair/replacement of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required by copper strip 20X3mm all as specified and as directed Please Enable Macros to View BoQ information
5S&F in repair/replacement of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required by copper strip 20X3mm all as specified and as directed Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56523284
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 10 Lakhs
LAST DATE 07-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Miscellaneous Repair To Electric Substation With Replacement Of Electric Flow Chart Diagrams, Distribution Networks , Replacement Of Insulation Matting, Renewal Of Earthings Of Switch Gears At Ayodhya Cantt Under Age(I) Ayodhya.
Basic Detail
Tender No 8400/206/E8
Bidding Type Tender
Location
City Ayodhya
State Uttar Pradesh
Key Dates
Publish Date 17 Jul 2026
Submission Date 07 Aug 2026
Open Date 17 Aug 2026
Finance
Tender Value 10 Lakhs
Tender Fee 500
EMD 20000
Exemption Available
Document List
7ec16a9c-472a-4145-96ea-39124dee3188.html
BOQ_872840.xls
TENDERDOCS179.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Aug 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
html

7ec16a9c-472a-4145-96ea-39124dee3188.html

xls

BOQ_872840.xls

pdf

TENDERDOCS179.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders