Tender For Provision Of Electrical Connections For Smart Warehouse Project And Repair/Restoration Of Damaged Electrical Connections In Shed Nos. 1 & 2 At Fsd Darbhanga Under Do Darbhanga
Tender Overview
Project Description
Tender for Provision Of Electrical Connections For Smart Warehouse Project And Repair/Restoration Of Damaged Electrical Connections In Shed Nos. 1 & 2 At Fsd Darbhanga Under Do Darbhanga
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 20-Jul-2026 | Amendment and Modification | Other | 29-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. (a) 8 module horizontal |
| 2 | (b) 2 module |
| 3 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole |
| 4 | (b) Single Pole & Neutral |
| 5 | (c ) Triple pole |
| 6 | (d) Triple pole & Neutral |
| 7 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 A |
| 8 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(a) 3 pin 5/6 A socket outlet |
| 9 | (b) 6 pin 15/16 A socket outlet |
| 10 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 11 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper busbar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 8 way, Double door |
| 12 | (b) 6 way, Double door |
| 13 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). (a) 4 way (4 + 12), Double door |
| 14 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)(a) 4 way (4 + 12), Double door |
| 15 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required(a) 6 x 4 sq. mm |
| 16 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required(a) 6 X 2.5 sq. mm |
| 17 | (c) 3X2.5 sq. mm |
| 18 | (d) 6X1.5 sq. mm |
| 19 | (e) 3X1.5 sq. mm |
| 20 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (a) 25 mm |
| 21 | (b) 20mm |
| 22 | Supplying and fixing of 1000 mm x 1000 mm size metallic frame cover fabricated with 35 mm x 35 mm x 5 mm thick angle iron welded construction frame structured and 3 mm thick M. S. sheet cover plate panel with double hinges and knob type locking arrangement including painting, making recess in wall, masonry, plastering & finishing the good (As per directions of Engineer-In Charge) |
| 23 | Supplying and fixing of 600mm x 600mm size metallic frame cover fabricated with 35 mm x 35 mm x 5 mm thick angle iron welded construction frame structured and 3 mm thick M. S. sheet cover plate panel with double hinges and knob type locking arrangement including painting, making recess in wall, masonry, plastering & finishing the good (As per directions of Engineer-In Charge) |
| 24 | Supplying and fixing of 300mm x 300mm size metallic frame cover fabricated with 35 mm x 35 mm x 5 mm thick angle iron welded construction frame structured and 3 mm thick M. S. sheet cover plate panel with double hinges and knob type locking arrangement including painting, making recess in wall, masonry, plastering & finishing the good (As per directions of Engineer-In Charge) |
| 25 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.(a) 200 mm X 150 mm X 60 mm deep |
| 26 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.(a) 15/16 amps switch |
| 27 | Supplying of XLPE Armoured cable with aluminium conductor of 1.1 KV grade confirming to IS:7098 (Part- I) 1988 with up to date amendments of the following size as required.(a) 3 x 10 sq.mm |
| 28 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Up to 35 sq. mm (clamped with 1mm thick saddle) |
| 29 | Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 30 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 31 | Dismantle of 20/25 existing old conduit at any height, cleaning and refixing of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 32 | Supplying, installation, Testing and commissioning of 70 watt LED type Well Glass luminaires in pressure die-cast aluminium housing with IP 66, system efficacy of ≥105 lm/W,colour temp 5700 K,THD( %) ≤ 10, Polycarbonate diffuser in opal finish and fixing on truss with suitable clamps and nut bolts and also dismantling the existing fitting etc at the site of work as required. |
| 33 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt)Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)40 watt |
| 34 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC40 watt 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).72 watt Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 7 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender